Refining Corneal Trephination and Donor Preparation for Artificial Cornea Surgery World Cornea Congress VII April 15 - 17 2015, San Diego 2015 Behrooz.

Slides:



Advertisements
Similar presentations
Sérgio Kwitko, Tiago Lansini, Andressa P Stolz, Diane R Marinho Authors have no financial interest in the subject matter of this poster.
Advertisements

Clinical Associate Professor Department of Ophthalmology Loyola University at Chicago, U.S.A. Visiting Professor Department of Defense, Military Medical.
Writing Committee for the Cornea Donor Study Research Group
Comparison of surgically induced astigmatism after phacoemulsification trough 3.2, 2.2 and 1.8 clear corneal incision. Luis Izquierdo Jr MD. PhD. Maria.
Relationship Between Donor Graft Cell Count and Visual Outcome in DSAEK Patients Authors Silvin Bakalian MD PhD, Johanna Choremis MD FRCSC, Michele Mabon.
Non-Invasive Keratograph Tear Break-Up Time versus Invasive Fluorescein-Associated Tear Stability Test: Experimental Validation Study Nizar S Abdelfattah,
World Cornea Congress VII – Electronic Poster Season Tse Wing Yeung, MBBS, FRANZCO Ronan Conlon, MD; Joshua Teichman, MD, FRCSC; Setareh Ziai, MD, FRCSC;
Evaluation of a new technique for the preparation of endothelial grafts for Descemet’s membrane endothelial keratoplasty (DMEK) World Cornea Congress VII.
Visual and Refractive Outcomes of Small-Incision Lenticule Extraction Performed by Cornea Fellows Victor Boullosa, MD, Erick Hernandez-Bogantes, MD, Arturo.
Bilateral Corneal Trophic Ulcers and Subsequent Infectious Keratitis in a Patient with Graft-versus-host Disease Yonca Aydın Akova, MD Bayındır Hospital,
Partnerships for Success: Corneal Transplant in the 21st Century Breakout Session A Presenters: Christopher Blanton, MD Medical Director, Ocular Services,
Topography-Guided Photorefractive Keratectomy for Irregular Astigmatism following Penetrating Keratoplasty Johnson Tan, MBBS MRCSEd (Ophth) FRCSEd (Ophth)
Copyright restrictions may apply JAMA Ophthalmology Journal Club Slides: Retinal Nerve Fiber Layer Loss and Quality of Life in Glaucoma Gracitelli CPB,
April 15-17, 2015 World Cornea Congress VII San Diego, California
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Deep Stromal Dissection for Endothelial Keratoplasty Obtained with a Femtosecond Laser and a Microkeratome with Different Head Advancement Speeds. A Scanning.
Retinal Detachment after Keratoprosthesis Placement: Incidence, Predisposing Factors, and Visual and Anatomic Outcomes M. Stephanie R. Jardeleza, M.D.
Prof. A. John Kanellopoulos, MD 1 Long-term Safety and Efficacy of High-Fluence Collagen Crosslinking of the Vehicle Cornea in.
Lori Lombardi MD, Mark A. Terry MD, Neda Shamie MD, Anand K. Shah MD, Daniel J. Friend MS *Dr. Terry has a financial interest in Bausch & Lomb instruments.
Short Term Visual Outcomes Boston Keratoprosthesis Type I
Tissue Complications During Endothelial Keratoplasty David B. Glasser, M.D. Columbia, MD The author has no financial interest in the subject matter of.
Natalie Stanciu, MD Richard M. Awdeh, MD Takeshi Ide, MD Sonia Yoo, MD Bascom Palmer Eye Institute ASCRS 2009: San Francisco.
INSTITUTO DE OJOS Dr. HUGO DANIEL NANO Buenos Aires, Argentina No financial disclosures to discuss.
Jorge L. Alio MD PhD Ma. Cecilia C. Agdeppa MD VISSUM-Instituto Oftalmologico de Alicante ASCRS Convention 2010 Boston Efficiency of MicroIncision Cataract.
Financial Disclosure: None
WEILL.CORNELL.EDU Outcomes of Acute Interventions for SJS/TEN Using a Novel Grading Scale and Treatment Algorithm World Cornea Congress VII Jessica B.
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
E-Poster Price Vision Group & Cornea Research Foundation of America Descemet - Stripping Endothelial Keratoplasty :Survival Outcomes in Eyes with Pre-
Miguel A. López M.D., María A. González Reiley M.D. The authors have no financial interest in the subject matter of this poster.
A New Technique for Precise, Predictable SBK Surgery Using the B&L Zyoptix XP Microkeratome David R. Shapiro, MD Shapiro Laser Eye Center Ventura, California.
J. Brian Foster, MD No Financial Disclosures
FEMTOSECOND LASER-ASSISTED KERATOPLASTY: WOUND INTEGRITY IN EYE BANK EYES João Baptista Malta, MD, H. Kaz Soong, MD, Roni Shtein, MD, Michael Banitt, MHA,
Wound Architecture and Wound Healing after Torsional and Longitudinal Phaco in a Rabbit Model Carolina Eyecare Physicians, LLC Research Assistant Professor.
Deep Anterior Lamellar Keratoplasty (DALK) Vs Penetrating Keratoplasty (PK) in patients with Keratoconus (KC). Dr. K.S.SIDDHARTHAN Aravind Eye Hospital.
Effect of an irregular anterior surface on a lamellar femtosecond laser cut Robert E. Fintelmann, MD Michele M. Bloomer, MD Bennie H. Jeng, MD Authors.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
World Cornea Congress VII - April 15-17, 2015 Electronic Poster
Comparison of Endothelial Keratoplasty (EK) Visual Outcomes with OCT Derived Corneal Thickness Measurements Authors Abraham K. Sleem, MD Robert L. Schultze,
Hongseok Yang, MD Department of Ophthalmology, Ajou University School of medicine, Suwon, Korea The author has no financial interest.
Cost-Effectiveness of the Type II Boston Keratoprosthesis Jared D. Ament, MD, MPH, Tomasz P. Stryjewski, BS, Siddharth Pujari, PhD, George Papaliodus,
0 Case Study Learning Curve. ACADEMY OF OPHTHALMOLOGY Financial Disclosure The speaker has no financial interest in the subject matter.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Effect of Donor Processing and Storage Time and Preoperative Endothelial Cell Counts on DSAEK Detachment Rates Daniel Demsey BScE Stephanie Baxter MD,
Banking Strategy toward customized Precut Corneal Tissues Autors: 1 Urbanova,Y. 1,2 Netukova, M., 1,2 Kuchynka, P. The authors have no financial interest.
Financial Interest Disclosure (over the past 24 months) Commercial Interest Relationship Company A advisory board, consultant, investigator Company B speaker.
FIGURE 1. The nGoggle device
Corneal collagen crosslinking combined with a new lamellar artificial cornea in a patient with advanced keratoconus  Ronan Conlon, MD, Joshua Teichman,
World Cornea Congress VI April 7-9, 2010
Laboratory evaluation of LASIK flap parameters created with 2 femtosecond lasers ASCRS, San Diego 2011 Chatzilaou, Georgios, MD¹ A. John Kanellopoulos,
DSAEK using corneas with previous LASIK
Prospective Study Comparing Outcomes of Torsional versus Traditional Phacoemulsification Systems on Dense Cataracts Bonnie An Henderson MD, Kelly J Grimes.
Relevant Financial Disclosure(s)
Comparison of corneal powers obtained from four different devices
Anil Vedula MD Financial Disclosures: None Richard M. Awdeh MD
New Concept of DSAEK Injecting System
No Financial Interest in Study Material
Associate Professor of Ophthalmology
Conflict of Interest Disclosure (over the past 24 months)
Activity Title Mary Smith, MD Associate Professor
versus 2.75mm Incision Phacoemulsification
Disclosures Relevant financial relationships in the past twelve months by presenter or spouse/partner.    Employment: Company Name(s) Speakers Bureau:
Financial Interest/ Affiliation Name of Company(s)
Financial Interest/ Affiliation Name of Company(s)
2017 WORLD GLAUCOMA CONGRESS
Financial Interest/ Affiliation Name of Company(s)
Financial Disclosure I have/had an affiliation (financial or otherwise) with a commercial organization that may have a direct or indirect connection to.
Financial Disclosure Financial Interest / Affiliation
The S. Fyodorov EYE MICROSURGERY STATE INSTITUTION, Moscow, Russia,
Presentation transcript:

Refining Corneal Trephination and Donor Preparation for Artificial Cornea Surgery World Cornea Congress VII April , San Diego 2015 Behrooz Azizi, MD; Ronan Conlon, MD; Salina Teja. MD; Joshua C Teichman, MD, MPH; Season Yeung, MBBS, FRANZCO; Setareh Ziai, MD, FRCSC; Kashif Baig, MD, MBA, FRCSC University of Ottawa Eye Institute, Ottawa, Ontario, Canada

Financial Disclosures Drs. Azizi, Conlon, Teja, Yeung, Teichman, & Ziai have no financial relationships to disclose Dr. Baig has the following relationships: Financial Interest/ AffiliationName of Company(s) Grant/Research Support Allergan, Bausch & Lomb, Merck, Moria Employment/Honoraria/Consulting Fees/Travel Expenses Alcon, Allergan, Bausch & Lomb, Labtician Major Stock Shareholder None Member: Advisory Panel, Standing Committee, Board of Directors Allergan, Bausch & Lomb Other Financial or Material Interest None

Introduction  Corneal transplantation is a standard surgical treatment for many corneal diseases  However, there are situations in which replacement of the diseased cornea is best managed with an “artificial cornea”  The Boston keratoprosthesis (Kpro) is the most commonly utilized artificial cornea

Difficulty in achieving concentric punches Khalifa YM, Moshirfar M. Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue. Clin Ophthalmol Aug 19;4:931-3

Difficulty in achieving concentric punches Khalifa YM, Moshirfar M. Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue. Clin Ophthalmol Aug 19;4:931-3

Difficulty in achieving concentric punches John T. Use of trypan blue corneal staining and centration ring in Boston keratoprosthesis surgery. Techniques in Ophthalmology Dec. 7(4):

Purpose  To devise a simple and cost-effective device for the preparation of the donor corneal tissue for Kpro surgery.  This device will perform the outer 8mm and inner 3mm cuts with increased accuracy and precision to improve centration.

Methods  30 donor corneas that were not suitable for transplantation  3 arms (1:1:1 design)  3mm followed by 8mm punch  8mm followed by 3mm punch  Paired 3mm & 8mm punches utilizing the prototype  Computer software (Adobe Photoshop, San Jose, CA) was used to measure the centration of the punches by a masked examiner  Descriptive & inferential statistics were performed

Methods

Results – Decentration Error bars = ± SEM * P<0.0001

Results – Decentration

Conclusions  Our study demonstrates that pairing the two trephinations on the donor cornea with the use of a single device leads to increased predictability & ease of trephination