Type Code Labels and FlashScan® Type

Slides:



Advertisements
Similar presentations
EST3 Life Safety Platform
Advertisements

Yokogawa Network Solutions Presents:
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
1 Input/Output and Debugging  How to use IO Streams  How to debug programs  Help on coursework.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Special Functions and Trouble Zones.
Foundations of Real Estate Management
Signature & V Series Detectors and Modules.
ELCT 201 Build and Troubleshoot. Idea Proposed Students will build a “big” system circuit from “small” subsystems circuits Students will develop a instrument.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
DriveAP 1.2 & 2.1 DriveWare®.
Computer Programming and Basic Software Engineering 4. Basic Software Engineering 1 Writing a Good Program 4. Basic Software Engineering 3 October 2007.
Advanced Tool Management Information Module Advanced Tool Management Information Module.
About the Presentations The presentations cover the objectives found in the opening of each chapter. All chapter objectives are listed in the beginning.
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
VeriFire Tools Network Diagnostic Utility
SmartLine Startup.
BY BILLY NIGZUS TERM FIRE ALARMS. WHAT ARE FIRE ALARMS ? Fire alarms are a device or a system that alert people when there is a fire. A device.
ONYX Product Overview.
Chapter 14: Inspection and Maintenance
Addressable Fire Alarms
V-Cert Music Technology
RP-2000 Series Deluge & Agent Releasing Panels
ZONES SOFTWARE What needs to happen? Intelligent devices with intelligent control panels, allow almost unlimited flexibility through the use of Software.
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
Fire Alarm System Initiating Devices
Burglar & Fire Alarm Basics
BY VENUS BRIGHT Input Output. What is a input An input is something simple that connects into the computer. Such as the most common input is a keyboard.
Basic Computer Technology Online Education Solutions© (773)
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Electrical Distribution Training
ACS Annunciators. EIA-485 specification Overview RPT May extend the length 4,000 feet.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
ADT490 TroubleShooting Device Failures. 2 Introduction ‣ Many problems are external to FAS ‣ Many are device problems.
Microcontroller based system design Asst. Prof. Dr. Alper ŞİŞMAN.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Intelligent Control Panel SLC
Vex Robotics Programming Options. To start you off and give you a safe "home base" to return to while you explore, a few key programs are already included.
Intro to Software System Modeling
FIRST Electrical Design FIRST Robotics Championship Conference Steven Shade Team 1111 April 16, 2003.
2 December, 2015 New Conventional Fire Control Panel.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
12/16/  List the elements of 8255A Programmable Peripheral Interface (PPI)  Explain its various operating modes  Develop a simple program to.
ADT490 TroubleShooting Locating Opens A. 2 Introduction Breakdown in Circuit Integrity -> Trouble Metallic continuity interrupted an “ open ” occurs System.
Intelligent Control Panel SLC
FIREPOWER BY SABURKE. Distributed Power Modules Model 5495Model Amps9 Amps.
VULCAN Handshake June Purpose Control system tracks – Proton charge on target – # of neutrons received by detector – # of neutrons..
In computing, an input device is a piece of computer hardware equipment used to provide data and control signals to an information processing system such.
Fire Detection Equipment and Systems in Dubai
Medical Education Center
Lesson Objectives Aims You should be able to:
Development Environment
Health Professional Education Building
Medical Education Center
RL78 POC and LVD © 2010 Renesas Electronics Corporation. All rights reserved.
Group Number 42: Monitoring System for Rotating Turbines
Roller Coaster Design Project
Getting PB4 Hulu Error On Windows 10 And 8.1 OS. (Check out here)
PLC / SCADA / HMI Controllers: Name : Muhammad Zunair Comsats University Date: 28-October-2018.
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Sensors and actuators Sensors Resistive sensors
ACOE347 – Data Acquisition and Automation Systems
The Programmable Peripheral Interface (8255A)
FIRE ALARM DRILL 26 © Ted Smith 2017.
Presentation transcript:

Type Code Labels and FlashScan® Type For All Onyx Panels including the NFS-320, NFS2-640 and NFS2-3030

What is the Difference Between Type Code Label, and FlashScan® Type?

What is the Difference Between Type Code Label, and FlashScan® Type? Type Code Label defines what you wish to do with a device FlashScan® Type is determined by what type of device is being used.

What is the Difference Between Type Code Label, and FlashScan® Type? Example: FSP-851 photo-electric smoke detector It can be an alarm input, or a supervisory. If supervisory, it can be tracking or latching. This is all determined by the Type Code Label. Regardless of selection, the FlashScan® Type will be PHOTO.

Type Code Labels Type Code Labels are software selections for: Initiating devices Detectors Monitor Modules Output devices Control Modules Relay Modules NACs

Type Code Labels for Detectors There are many types of Detectors Photo Ion Laser Heat (Fixed and Rate of Rise) Acclimate ® Plus™ HARSH™ (Hostile ARea Smoke Head) IntelliQuad™ (Smoke, Heat, IR and CO)

Type Code Labels for Detectors Possible uses for a PHOTO (FSP-851) detector Type Code Point Type Latching (Y/N) Activates CBE Device Function SMOKE (PHOTO) Fire Y Photoelectric smoke detector SUP L(PHOTO) Supervisory SUP T(PHOTO) N SMOKE (DUCTP) SUP L(DUCTP) SUP T(DUCTP) Other types of detectors would have similar options

Type Code Labels for Input Modules After auto-programming…. …. Default Type Code Label is MONITOR …. FlashScan ® Type is MONITOR or MINI/DUAL The panel doesn’t know what is connected to it It is up to YOU to tell it!

Type Code Labels for Input Modules Here are some examples of Monitor Module Type Code Labels. *Note that this type code label is only available for the NFS2-3030 ** Some type code labels allow for system functions, such as Acknowledge, Silence, Reset and Drill. Type Code Point Type Latching (Y/N) Activates CBE Device Function MONITOR Fire alarm Y Alarm-monitoring device PULL STATION Manual fire-alarm-activating device WATERFLOW S Supervisory Indicates supervisory condition for activated waterflow switch. FMM 4-20* User-programmable Monitors 4-20 mA industrial sensors RESET SWITCH** Non-alarm N Performs reset function *Note that this Type Code Label only applies to the NFS2-3030. **Type Code Labels also allow for some system functions, such as Acknowledge, Silence, Reset, and Drill

Type Code Labels for Output Modules After auto-programming…. …. the panel will often set default values to CONTROL or RELAY with the appropriate FlashScan ® Type. Again, the panel doesn’t know what is connected to it. It is up to YOU to tell it!

Type Code Labels for Output Modules Examples of Output Types taken from the NFS2-3030 Programming Manual *Note that this type code label is only available for the NFS2-3030 ** Some type code labels allow for system functions, such as Acknowledge, Silence, Reset and Drill. Type Code Silenceable Switch Inhibit Walk Test SLC Output Point Local Mode Group Point Types Device Function CONTROL Y N NAC n/a Supervised NAC RELAY Relay Relay output STROBE CKT Fire SPEAKER Supervised NAC for speaker circuits REL AUDIBLE Activates audio or visual devices steady when releasing starts.

Programming Examples

NFS2-3030 Point Programming This is the Type Code Label This is the FlashScan® Type

NFS2-640/NFS-320 Point Programming This is the Type Code Label Note that the FlashScan ® Type cannot be changed at the panel with the NFS2-640 or NFS-320.

VeriFire™ Tools Selection This is the Type Code Label This is the FlashScan® Type Note that this is the Point Programming screen for the NFS2-3030. The NFS2-640 and NFS-320 screens look different, but the selection process is the same.

FlashScan® Type When the panel is auto-programmed, the appropriate selection will be made. Most of the time, this is sufficient. However, there are a few instances to watch out for.

FlashScan® Type Issue #1 FlashScan® Type for the FDM-1, FMM-101, and XP-10M monitor modules is MINI/DUAL. If Type Code Label is changed using VeriFire Tools (i.e. WATERFLOW), it reverts to the generic FlashScan® Type of MONITOR. This will result in an Invalid Reply trouble for the device. It must be set to Mini/Dual prior to downloading.

FlashScan® Type Issue #1 Screen as it would appear after initial auto-program. Note that default values are set.

FlashScan® Type Issue #1 Change type Code Label to something else, like H20 flow.

FlashScan® Type Issue #1 Note what happens to the FlashScan® Type selection. This would have to set back to the MINI/DUAL selection to function properly.

FlashScan® Type Issue #2 For certain releasing Type Code Labels, the FlashScan® Type is automatically set to RELEASE. Recall that the FlashScan® Type is set by the hardware, not the application. Results in an Invalid Reply trouble RELEASE FlashScan® Type is only for the FCM-1 REL module Only applies to VeriFire™ Tools programming

FlashScan® Type Issue #2 This Type Code Label is used for a relay used to perform a releasing function Since it is an FRM-1 Relay Module, this is the incorrect FlashScan® Type.

FlashScan® Type Issue #2 This Type Code Label is used for a relay used to perform a releasing function The correct FlashScan® Type is RELAY

? Blah,Blah,Blah, Blah,Blah,Blah. What was he talking about ? Z z z z z z z z z z Questions, Comments, Ideas ? Basic Fire Alarm Technology