Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.

Slides:



Advertisements
Similar presentations
Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance at Extreme Hadron Fluence G. Lindström (a), E. Fretwurst (a), F. Hönniger.
Advertisements

IAP-PAI 25/05/20051 CMS Si Rad. Hardness Introduction Damage in Si Neutron tests => Beam => Irrad. Setup.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
3D simulations of device performance for 3D-Trench electrode detector Jianwei Chen a,b, Hao Ding a,b, Zheng Li a,b,c, *, Shaoan Yan a,b a Xiangtan University,
New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
Diamond Manufacturers for ATLAS Upgrades March 26, 20121R. Kass Brief Overview: Next Upgrade (IBL): Diamond Beam Monitor (DBM) News from two diamond manufacturers.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
Plot Approval Yat Long Chan (CUHK) Igor Mandic (Ljubljana) Charlie Young (SLAC)
SOLAR CELL TESTING. SOLAR CELL TESTING Basic Structure of a Solar Cell.
Slide 1 Irradiation Study of Single Crystal Diamond Sensors for the PLT Irradiation of sensors at the PS 1.5 years ago Comparison to RD42 irradiated poly.
EE580 – Solar Cells Todd J. Kaiser
Investigation of the properties of diamond radiation detectors
Test of Pixel Sensors for the CMS experiment Amitava Roy Purdue University.
Beam Condition Monitor for the CMS BCM Group Luis Fernández Hernando (EST/LEA), Christoph Ilgner (EST/LEA), Alick Macpherson (CMS/CMM), Alexander Oh (CMS/CMD),
Patrick Spradlin, SCIPP trip to LLU, May 2, 2001 Detector Characteristics.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
On MCz SCSI after 24 GeV/c proton irradiation 12th RD50 Workshop Ljubljana, 2-4 June 2008 D. Creanza On behalf of the Bari and Pisa RD50 groups.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Measurements on Single and Poly Crystal CVD Diamond Sensors
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
X-ray radiation damage of silicon strip detectors AGH University of Science and Technology Faculty of Physics and Applied Computer Science, Kraków, Poland.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Radiation Hard Sensors for the Beam Calorimeter of the ILC C. Grah 1, R. Heller 1, H. Henschel 1, W. Lange 1, W. Lohmann 1, M. Ohlerich 1,3, R. Schmidt.
FCAL R&D in Minsk Group: Sensors and Electronics FCAL Collaboration MPI Munich October 17, 2006, Munich, Germany Presented by Igor Emeliantchik.
Study of leakage current and effective dopant concentration in irradiated epi-Si detectors I. Dolenc, V. Cindro, G. Kramberger, I. Mandić, M. Mikuž Jožef.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
Edge-TCT and Alibava measurements with pion and neutron irradiated micro-strip detectors V. Cindro 1, G. Kramberger 1, I. Mandić 1, M. Mikuž 1,2, M. Milovanović.
CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
SILICON DETECTORS PART I Characteristics on semiconductors.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
1 Investigation into properties of neutron and electron irradiated CCD By Nick Sinev University of Oregon Jim Brau, Jan Strube, Olya Igonkina, Nick Sinev.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Si-detector macroscopic damage parameters during irradiation from measurements of dark current evolution of with fluence Craig Buttar, University of Sheffield.
Background Simulations for the LHCb Beam Condition Monitor Overview: ● The LHCb Beam Condition Monitor (BCM) – Purpose, Design and Function – Implementation.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
Inversion Study on MCz-n and MCz-p silicon PAD detectors irradiated with 24 GeV/c protons Nicola Pacifico Excerpt from the MSc thesis Tutors: Prof. Mauro.
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Simulations of Hadron Irradiation Effects for Si Sensors Using Effective Bulk Damage Model A. Bhardwaj 1, H. Neugebauer 2, R. Dalal 1, M. Moll 2, Geetika.
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
Technical Meeting Diamond Detector Characterization in Frascati F. Burkart F. Burkart, O. Stein.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Simulation of new P-Type strip detectors 17th RD50 Workshop, CERN, Geneva 1/15 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona.
Double Electric field Peak Simulation of Irradiated Detectors Using Silvaco Ashutosh Bhardwaj, Kirti Ranjan, Ranjeet Singh*, Ram K. Shivpuri Center for.
Diamond Sensor Tests for the CMS BCM Alexandr Ignatenko FCAL collaboration meeting May 7, 2008.
RD05 Florence CVD Diamond Radiation Sensors For Application In Very High Radiation Environments 7 th International Conference on Large Scale Applications.
3D SEMICONDUCTOR RADIATION DETECTOR R&D AT HIP EUDET-JRA2 MEETING NIKHEF Juha Kalliopuska.
Influence of humidity on the IV characteristics A.Chilingarov Lancaster University ATLAS SCT Week CERN,
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Progress report on the internal target
Charge collection studies with irradiated CMOS detectors
Sep th Hiroshima Xi’an Test-beam evaluation of newly developed n+-in-p planar pixel sensors aiming for use in high radiation environment.
Investigation of diamond sensors for calorimetry
Results from the first diode irradiation and status of bonding tests
大強度
Radiation Damage in Silicon
Testbeam Results for GaAs and Radiation-hard Si Sensors
Beam Test Results for the CMS Forward Pixel Detector
Radiation damage in Diamond
Presentation transcript:

Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard Eleni Berdermann Peter Weilhammer

Diamond Characterization Measurements performed on diamonds: I-V curve. First quality check of the samples, metallisations. Collection distance vs time. Study of the pumping. Charge collection distance at 1 V/ µm. Collection distance vs bias voltage. Measurement of the charge collection distance at different electric fields. Study of the radiation damage. Study of the polarization. I-T curve. Find the thermo-stimulated current peak. Number of traps. Depumping of diamonds.

Diamond Characterization The software gets the top value of the peak and deducts the average value of the base Those values are averaged over a certain time (usually 5 min) for calculating the collection distance

I-V curves CDS μm thick polycrystalline diamond CDS μm thick polycrystalline diamond Polycrystalline diamond I-V curves:

I-V curves Mono-crystalline diamond I-V curves: E6-sc μm thick monocrystalline diamond CDS μm thick monocrystalline diamond

Pumping Pumping for an 360 μm thick polycrystalline CVD diamond at 1V/ μm. Pumping for a 500 thick polycrystalline CVD diamond at 1V/ μm. Pumping performed with a collimated 90Sr β-source.

Pumping Monocrystal diamond e6-sc-01 does not present pumping. The collection distance was bigger than the thickness. After a heating process that collection distance went to a more reasonable value.

Collection distance vs Bias Signal from CDS113 (500 µm). to a MIP vs time at different voltage steps. A polarization is present in each step.

Collection distance vs Bias Collection distance vs the electric field for CDS113 (500 µm). Each point represents the signal after a stabilization period of 4 hours.

Collection distance vs Bias Collection distance vs Electric field for e6-sc-01 (440 µm). Collection distance vs Bias CDS134 (490 µm).

Collection distance vs Bias CDS134, monocrystal diamond, presented polarization periods like any polycrystal. E6-sc-01 did not show polarization.

CDS116 (500 µm). First irradiation of protons/cm 2. Second irradiation of 2.8x10 15 protons/cm 2. Equivalent to 10 years of LHC at normal operation near the IP5. Radiation damage on polycrystalline samples CDS126 (300 µm). First irradiation of 5x10 14 protons/cm 2. Second irradiation of 2.3x10 15 protons/cm 2.

Radiation damage The radiation affected the signal of the diamond and the evolution of the polarization and depolarization. The plot is of CDS126.

Radiation damage CDS 116 signal at 1 V/µm and leakage current after the first irradiation. CDS 126 signal at 1 V/µm and leakage current after the first irradiation.

Radiation damage CDS 116 signal at 1 V/µm and leakage current after the first irradiation and after a heating process that fully depumped the diamond. The dose necessary for pumping it has increased. CDS 126 signal at 1 V/µm and leakage current after the first irradiation and after a heating process that fully depumped the diamond.

Radiation damage CDS 116 signal at 1 V/µm and leakage current after the second irradiation. CDS 126 signal at 1 V/µm and leakage current after the second irradiation.

Diamond showed a signal degradation due to radiation damage of a 42% after a proton fluence equivalent to 10 years of normal operation of the LHC near the IP5. The leakage current from the diamonds decreased down to a 60% from its original value prior to irradiations. The most important effect of radiation damage on diamond is the creation of charge traps in its bulk. Due to this effect pumping periods increase considerably. The number of generated traps can be so important that in case the diamond is depumped those traps will suck the electron hole pairs generated by a passing particle masking the signal completely. After performing a TSC diamonds showed, after a pumping period, to have recovered the original collection distance values. New traps have been created, but those once filled do not interfere with the signal. Damage that made a decrease on the signal seemed to have disappeared. Some conclusions

TSC measurements Temperature vs time for the measurements. The rate is quite constant and reproducible. Current vs temperature for CDS126 after the first irradiation with the proton beam.

TSC measurements Current vs temperature for e6- sc-01 after 2 hours of irradiation with the strontium source. Current vs temperature for CDS115 after 2 hours of irradiation with the strontium source.

The similar temperatures at where the TSC peaks were produced, indicate that the charge traps in those diamonds are in similar energy levels. That could indicate that the kind of impurities is the same for all of them. The two polycrystalline diamonds measured were made from the same wafer, therefore this is expected. The monocrystal e6-sc-01, instead, did not show any hint about charge traps during the collection distance measurements, it did not pump neither polarized, yet a TSC peak is observed, also in a similar temperature range. That confirms the presence of traps, from impurities, in the crystal lattice. Impurities that may be similar to the polycrystalline ones. Nevertheless, the level of current achieved by the monocrystal is much less important than the ones achieved from the polycrystalline ones. Some conclusions