John Arthur November 14, 2005 Summary Discussion John Arthur SLAC LCLS Beam-Based Undulator K Measurement Workshop.

Slides:



Advertisements
Similar presentations
Soft X-ray Self-Seeding
Advertisements

Workshop Issues Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center Diagnostics.
Tomsk Polytechnic University1 A.S. Gogolev A. P. Potylitsyn A.M. Taratin.
Stanford Synchrotron Radiation Lightsource Sources and Optics for XAS Apurva Mehta.
The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.
05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
Richard M. Bionta XTOD July 19-21, 2005 UCRL-PRES-xxxxxx X Ray Diagnostics LCLS FAC Meeting Oct. 27, 2005.
Bragg Spectrographs for LCLS Diagnostics and Science D. Peter Siddons Zhong NSLS Brookhaven National Laboratory Upton, NY
James Welch October 30, FEL Commissioning Plans J. Welch, et. al. FEL Commissioning Plans J. Welch, et. al. Accelerator.
Richard M. Bionta XTOD October 12, 2004 UCRL-PRES-XXXXX X Ray Transport, Optics, and Diagnostics, Overview Facility Advisory Committee.
Bingxin Yang High resolution effective K September 22-23, 2004 High-Resolution Effective K Measurements Using Spontaneous.
Possible spectrometers
X-Ray Diagnostics for the LCLS Jan , 2004 UCLA.
Bingxin Yang Large aperture spectrum Beam-based undulator measurement workshop, Nov. 14, 2005 Undulator Effective-K Measurements.
1 A Grating Spectrograph for the LCLS Philip Heimann Advanced Light Source Observe the spontaneous radiation spectrum of the individual undulators Observe.
LCLS Undulator Magnet Irradiation Sensitivity Workshop Thursday June 19, 2008 Jeff Dooling 1 SLAC Redwood Room A/B, SLAC Thursday, June.
“Pinhole Measurement” Approach to K Measurements using Spontaneous Radiation November 14, 2005 J. Welch, R. Bionta, S. Reiche.
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Alignment.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
BBA Related Issues Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center Undulator.
John Arthur X-Ray Optics October 12, 2004 X-Ray Prototype Optics Specifications John Arthur.
Richard M. Bionta X-Ray Transport, Diagnostic, & Commissioning September 22, 2004 UCRL-PRES Two Problems... LCLS Diagnostics.
UCLA The X-ray Free-electron Laser: Exploring Matter at the angstrom- femtosecond Space and Time Scales C. Pellegrini UCLA/SLAC 2C. Pellegrini, August.
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
Richard M. Bionta XTOD Beam and Detector October 12-13, 2004 UCRL-PRES-XXXXX XTOD Beam and Detector Simulations Facility Advisory.
R. M. Bionta SLAC November 14, 2005 UCRL-PRES-XXXXXX LCLS Beam-Based Undulator K Measurements Workshop Use of FEL Off-Axis Zone Plate.
Introduction – November 14, 2005 Heinz-Dieter Nuhn, SLAC / LCLS Beam Based Undulator Measurements Workshop 1 Introduction Heinz-Dieter.
John Arthur LCLS Diagnostics and Commissioning September 22, 2004 Summary of Related Topics from the Miniworkshop on.
Bingxin Yang Undulator / FEL October 12, 2004 Undulator / FEL Diagnostics Bingxin Yang Argonne National Lab.
USING A MICRO FABRICATED UNDULATOR TO BRIDGE THE FOUR DECADE GAP BETWEEN REGULAR PURE PERMANENT MAGNET UNDULATORS AND INVERSE COMPTON SCATTERING SOURCES.
Latest Results on HXRSS at LCLS Franz-Josef Decker 4-Feb Seeding with 004, 220 and over-compression 2.Tuned beam with slotted foil cutting horns.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
James Welch August 27,2009 FEL 2009 Undulator K-Parameter Measurements at LCLS J. Welch, SLAC National Accelerator Laboratory Contributors:
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
07/27/2004XFEL 2004 Measurement of Incoherent Radiation Fluctuations and Bunch Profile Recovery Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
A. Doyuran, L. DiMauro, W. Graves, R. Heese, E. D. Johnson, S. Krinsky, H. Loos, J.B. Murphy, G. Rakowsky, J. Rose, T. Shaftan, B. Sheehy, Y. Shen, J.
SPPS, Beam stability and pulse-to-pulse jitter Patrick Krejcik For the SPPS collaboration Zeuthen Workshop on Start-to-End Simulations of X-ray FEL’s August.
Assessing Single Crystal Diamond Quality
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
Stability Requirements for Superconducting Wiggler Beamlines
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Jyly 8, 2009, 3rd open meeting of Belle II collaboration, KEK1 Charles University Prague Zdeněk Doležal for the DEPFET beam test group 3rd Open Meeting.
Basic Energy Sciences Advisory Committee MeetingLCLS February 26, 2001 J. Hastings Brookhaven National Laboratory LCLS Scientific Program X-Ray Laser Physics:
Kiyoshi Kubo Electron beam in undulators of e+ source - Emittance and orbit angle with quad misalignment and corrections - Effect of beam pipe.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Today’s Lecture Interference Diffraction Gratings Electron Diffraction
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
FEL Simulations: Undulator Modeling Sven Reiche Start-end Workshop DESY-Zeuthen 08/20/03.
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Lessons Learned From the First Operation of the LCLS for Users Presented by Josef Frisch For the LCLS March 14, 2010.
Proposal for the End Station Test Beam (ESTB) at SLAC John Jaros ALCPG09 Albuquerque September 30, 2009.
Harmonic lasing in the LCLSII SXR beamline G. Marcus, Y. Ding, Z. Huang 11/21/2013.
8 th February 2006 Freddy Poirier ILC-LET workshop 1 Freddy Poirier DESY ILC-LET Workshop Dispersion Free Steering in the ILC using MERLIN.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Soft X-Ray pulse length measurement
X-Ray Transport, Optics, and Diagnostics WBS Alan J
Gain Computation Sven Reiche, UCLA April 24, 2002
Optics John Arthur, SLAC & William W. Craig, LLNL April 24, 2002
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
LCLS Lehman Review February 7-9, 2005
Presentation transcript:

John Arthur November 14, 2005 Summary Discussion John Arthur SLAC LCLS Beam-Based Undulator K Measurement Workshop

John Arthur November 14, 2005 Define a strategy for using spontaneous undulator radiation to measure the K value of every individual LCLS Undulator Segment after installation in the Undulator Hall. To reach the objective, the physics and technologies necessary need to be identified. Workshop discussions will include Usable spectral features of spontaneous radiation Strategies for beam-based K measurements Specifications for suitable instruments Scheduling issues Three Work Packages have been defined and assigned to three different groups. Work described by these Work Packages has been carried out in preparation of the workshop and will be presented and discussed at the workshop. Define a strategy for using spontaneous undulator radiation to measure the K value of every individual LCLS Undulator Segment after installation in the Undulator Hall. To reach the objective, the physics and technologies necessary need to be identified. Workshop discussions will include Usable spectral features of spontaneous radiation Strategies for beam-based K measurements Specifications for suitable instruments Scheduling issues Three Work Packages have been defined and assigned to three different groups. Work described by these Work Packages has been carried out in preparation of the workshop and will be presented and discussed at the workshop. Workshop Objective

John Arthur November 14, 2005 Group: B. Yang, R. Dejus Task: Examine robustness of angle-integrated measurements of undulator spectrum. Consider effects of errors in beam alignment, undulator magnet structure, straightness of vacuum pipe, alignment of spectrometer, etc. Consider effects of location of undulator segment being tested. Determine what are realistic values for the precision with which the value of K can be determined for an undulator segment at the beginning, middle, and end of the undulator. This task explores the use of the high-energy edge of the fundamental spectral peak (the third harmonic may also be considered) of a single undulator to measure its K parameter. The measuring spectrometer will be located in the LCLS FEE, roughly 100 m downstream from the final undulator segment. Realistic values for the angular acceptance of the measurement (limited by beam-pipe apertures, or apertures at the measuring point) should be considered. Group: B. Yang, R. Dejus Task: Examine robustness of angle-integrated measurements of undulator spectrum. Consider effects of errors in beam alignment, undulator magnet structure, straightness of vacuum pipe, alignment of spectrometer, etc. Consider effects of location of undulator segment being tested. Determine what are realistic values for the precision with which the value of K can be determined for an undulator segment at the beginning, middle, and end of the undulator. This task explores the use of the high-energy edge of the fundamental spectral peak (the third harmonic may also be considered) of a single undulator to measure its K parameter. The measuring spectrometer will be located in the LCLS FEE, roughly 100 m downstream from the final undulator segment. Realistic values for the angular acceptance of the measurement (limited by beam-pipe apertures, or apertures at the measuring point) should be considered. Work Package 1: Angle Integrated Measurement

John Arthur November 14, 2005 Marking the location of a spectral edge We will watch how the following property changes: HALF PEAK PHOTON ENERGY

John Arthur November 14, 2005 Effects of Aperture Change (Size and Center) Plot the half-peak photon energy vs. aperture size Edge position stable for 25 – 140  rad  100  rad best operation point Independent of aperture size  Independent of aperture center position

John Arthur November 14, 2005 Effects of Undulator Field Errors Electron beam parameters E = GeV  x = 37  m  x’ = 1.2  rad    = 0.03% Detector Aperture 80  rad (H) 48  rad (V) Monte Carlo integration for 10 K particle histories.

John Arthur November 14, 2005 Comparison of Perfect and Real Undulator Spectra Filename: LCL02272.ver; scaled by to make K eff = First harmonic spectrum changes little at the edge.

John Arthur November 14, 2005 Measure fluctuating variables Charge monitor: bunch charge OTR screen / BPM at dispersive point: energy centroid Hard x-ray imaging detector: electron trajectory angle (new proposal)

John Arthur November 14, 2005 Summary of 1-undulator simulations (charge normalized and energy-corrected) Applying correction with electron charge, energy and trajectory angle data shot-by-shot greatly improves the quality of data analysis at the spectral edge. Full spectrum measurement for one undulator segment (reference) The minimum integration time to resolve effective-K changes is 10 – 100 shots with other undulator segment (data processing required) As a bonus, the dispersion at the flag / BPM can be measured fairly accurately. Not fully satisfied: Rely heavily on correction calibration of the instrument No buffer for “unknown-unknowns” Non-Gaussian beam energy distribution ???

John Arthur November 14, 2005 Differential Measurements of Two Undulators Insert only two segments in for the entire undulator. Steer the e-beam to separate the x-rays Use one mono to pick the same x-ray energy Use two detectors to detect the x-ray flux separately Use differential electronics to get the difference in flux

John Arthur November 14, 2005 Differential Measurement Recap Use one reference undulator to test another undulator simulataneously Set monochromator energy at the spectral edge Measure the difference of the two undulator intensity Simulation gives approximately: To get RMS error  K/K < 0.7  10 -4, we need only a single shot (0.2 nC)! We can use it to periodically to log minor magnetic field changes, for radiation damage. Any other uses?

John Arthur November 14, 2005 Yang Summary (The Main Idea) We propose to use angle-integrated spectra (through a large aperture, but radius < 1/  ) for high-resolution measurements of undulator field. Expected to be robust against undulator field errors and electron beam jitters. Simulation shows that we have sufficient resolution to obtain  K/K <  using charge normalization. Correlation of undulator spectra and electron beam energy data further improves measurement quality. A Differential technique with very high resolution was proposed: It is based on comparison of flux intensities from a test undulator with that from a reference undulator. Within a perfect undulator approximation, the resolution is extremely high,  K/K =  3  or better. It is sufficient for XFEL applications. It can also be used for routinely logging magnet degradation.

John Arthur November 14, 2005 Yang Summary (Continued) Either beamline option can be used for searching for the effective neutral magnetic plane and for positioning undulator vertically. The simulation results are encouraging (resolution ~1  m in theory for now, hope to get ~ 10  m in reality). What’s next Sources of error need to be further studied. Experimental tests need to be done. More calculation and understanding of realistic field Longitudinal wake field effect, Experimental test in the APS 35ID More?

John Arthur November 14, 2005 Group: J. Welch, R. Bionta, S. Reiche Task: Examine robustness of pinhole measurements of undulator spectrum. Consider effects of errors in beam alignment, undulator magnet structure, straightness of vacuum pipe, alignment of pinhole and spectrometer, etc. Consider effects of location of undulator segment being tested. Determine what are realistic values for the precision with which the value of K can be determined for an undulator segment at the beginning, middle, and end of the undulator. This task explores the use of the fundamental spectral peak (the third harmonic may also be considered) of a single undulator, as seen through a small angular aperture, to measure its K parameter. The measuring spectrometer will be located in the LCLS FEE, roughly 100 m downstream from the final undulator segment. Realistic values for the angular acceptance of the measurement should be determined, and the effects of misalignment of the aperture or undulator axis should be carefully considered. Group: J. Welch, R. Bionta, S. Reiche Task: Examine robustness of pinhole measurements of undulator spectrum. Consider effects of errors in beam alignment, undulator magnet structure, straightness of vacuum pipe, alignment of pinhole and spectrometer, etc. Consider effects of location of undulator segment being tested. Determine what are realistic values for the precision with which the value of K can be determined for an undulator segment at the beginning, middle, and end of the undulator. This task explores the use of the fundamental spectral peak (the third harmonic may also be considered) of a single undulator, as seen through a small angular aperture, to measure its K parameter. The measuring spectrometer will be located in the LCLS FEE, roughly 100 m downstream from the final undulator segment. Realistic values for the angular acceptance of the measurement should be determined, and the effects of misalignment of the aperture or undulator axis should be carefully considered. Work Package 2: Pinhole Measurement

John Arthur November 14, 2005 Basic Layout Basic Scheme Slit width must be small to get clean signal. 2 mm shown. Useg #1 is worst case

John Arthur November 14, 2005 Aligning the Pinhole Simple 2D scan, one shot per data point, 0.1 mm steps, no multi-shot averaging Error is added to geometry term. Actual beam Axis 0.5, 0.5 Scan range + / - 1 mm X and Y “Measured” Beam axis 0.33, 0.34

John Arthur November 14, 2005 Simulated K Measurement

John Arthur November 14, keV Transmission Grating P = 200 nm N = 500 D = 100  m Sputter-sliced SiC / B 4 C multilayer 33  m thick Beam 100  m Interference Function Single Slit Diffraction Pattern Observed Intensity angle

John Arthur November 14, nm period x 33 microns works diffraction peaks in far-field 200 nm period 33  m Waveguide coupling limits us to periods > 200 nm

John Arthur November 14, st Order Diffraction Peaks 4 mm FEL Transmission Grating Spectrometer Thick Slit 5 cm Ta capped with 1 cm B 4 C YAG Scintillator 50 microns thick Thin Adjustable Slit 1 mm Ta Very high energy photons go through everything micron 1 mm 6 m Transmission Grating 200 nm Period 100 micron Aperture 5 m

John Arthur November 14, 2005 Monte Carlo Generation of Photons from Near-Field Calculations Photons are aimed at Sven’s near field distributions… … but allowed to reflect off of the vacuum pipe or get absorbed in the breaks Slits, gratings and scintillator placed in beam

John Arthur November 14, 2005 Bionta Summary Investigated 100 micron aperture FEL Transmission Grating for use in measuring K Sensitivities are roughly at the limit of what is needed Signal level is too low by at least a factor of 200. More aperture, say 1.4 x 1.4 mm would help. Larger focal distance would allow larger periods Signal:Backgrounds with thin scintillator are at least 1:1 Beam stability and pointing (relative to the 100 micron aperture) will be an issue that is not investigated here

John Arthur November 14, 2005 Group: J. Hastings, S.Hulbert, P.Heimann Task: Assume that a single shot spectral measurement is needed for an LCLS spontaneous undulator pulse. What are the best options for doing the measurement? What spectral resolution can be obtained using these methods? What are the effects of beam jitter, spectrometer misalignment, etc? This task explores the design and performance of x-ray spectrometers capable of providing centroid or edge position with high resolution, on a single-shot of radiation from a single LCLS undulator. The spectrometer will most likely be located in the LCLS FEE, about 100 m downstream from the final undulator segment. Group: J. Hastings, S.Hulbert, P.Heimann Task: Assume that a single shot spectral measurement is needed for an LCLS spontaneous undulator pulse. What are the best options for doing the measurement? What spectral resolution can be obtained using these methods? What are the effects of beam jitter, spectrometer misalignment, etc? This task explores the design and performance of x-ray spectrometers capable of providing centroid or edge position with high resolution, on a single-shot of radiation from a single LCLS undulator. The spectrometer will most likely be located in the LCLS FEE, about 100 m downstream from the final undulator segment. Work Package 3: Single-Shot Spectral Measurement

John Arthur November 14, 2005 Possible spectrometers Bent Bragg (after P. Siddons-NSLS) Mosaic crystal Bent Laue Zhong Zhong-NSLS X-ray Grating P. Heimann-ALS, S. Hulbert-NSLS

John Arthur November 14, mm Si (422) surface normal R=3.9 m 76 mm Strip detector (200 strips) Bent Bragg Spectrometer Cu foil

John Arthur November 14, 2005 On axis +0.5 mm +1.0 mm Photon energy (keV) Und-pinhole distance 200 m Pinhole 2.0 x 0.02 mm 2

John Arthur November 14, 2005 Bent Bragg to do list Simulation considering position dependent spectrum Role of jitter Test K sensitivity with simulated data (including noise)

John Arthur November 14, x Mosaic spread 2   Mosaic crystal spectrometer

John Arthur November 14, 2005 Andreas Freund, Anneli Munkholm, Sean Brennan, SPIE, 2856,68 (1996) 10 keV 24 keV

John Arthur November 14, 2005 Mosaic crystal to do list Crystal uniformity ? Ultimate resolution ? Experimental geometry (20 m crystal to detector distance)

John Arthur November 14, 2005 Design criteria Goals Photon energy range: 800 – 8000 eV. Spectral resolution:  < 1 x set by the FEL radiation bandwidth Spectral window  > 1 x set by the single undulator harmonic energy width Single shot sensitivity for single undulator spectra. Consider damage for FEL radiation

John Arthur November 14, 2005 LCLS grating spectrometer layout One VLS grating in -1 order Length of spectrometer 1.3 m

John Arthur November 14, 2005 Raytracing of the grating spectrometer: 8000 eV Source 90  m diameter (fwhm) 7992, 8000, 8008 eV or 7600, 8000, 8400 eV At the detector 1.1 mm (h) x 2  m (v) (fwhm)  E = 14 eV (6x10 2 RP, limited by detector pixel size 13  m, in FEL case could use inclined detector) 7992 eV 8000 eV 8008 eV 7600 eV 8000 eV 8400 eV 800  m

John Arthur November 14, 2005 Is there single shot sensitivity for spontaneous radiation? Undulator (1) Flux F = 1.4 x N Q n I = 3 x /(pulse 0.1% bw) Bandwidth  E/E = 1/N = 8.8 x10 -3 Divergence  r ‘ = /2L = 15  rad (800 eV) and 4.8  rad (8 keV) Spectrometer Vertical angular acceptance 60  rad (800 eV) and 20  rad (8 keV) Efficiency  = R M1.  G = 0.13 (800 eV) and 0.08 (8000 eV) Flux at detector x 10 5, N noise ~ 0.2 % Yes

John Arthur November 14, 2005 Summary: the Grating Spectrograph for the LCLS Photon energy range: 800 – 8000 eV. Resolving power: E  E = 2000 at 800 eV and 300 at 8 keV. For FEL radiation the resolution could be improved with an inclined detector. Spectral window:  E  E = 10%. Single shot sensitivity for single undulator spectra.

John Arthur November 14, 2005 Characterize the spectral features of spontaneous synchrotron radiation that are usable for beam-based K-measurements. Identify the most appropriate strategy for beam-based K- measurements. Specify suitable instruments for the identified beam-based K- measurement strategy. List expected performance parameters such as resolution of K measurement as function of beam charge, and segment location as well as expected tolerances to trajectory and energy jitter. List any open questions regarding the feasibility of the most appropriate strategy. List the R&D activities, if any, needed before the design of a measurement system can be completed and manufacturing/procurement can start. Characterize the spectral features of spontaneous synchrotron radiation that are usable for beam-based K-measurements. Identify the most appropriate strategy for beam-based K- measurements. Specify suitable instruments for the identified beam-based K- measurement strategy. List expected performance parameters such as resolution of K measurement as function of beam charge, and segment location as well as expected tolerances to trajectory and energy jitter. List any open questions regarding the feasibility of the most appropriate strategy. List the R&D activities, if any, needed before the design of a measurement system can be completed and manufacturing/procurement can start. Workshop Charge

John Arthur November 14, 2005 Response to Charge Are the spectral features robust? Yes. Angle-integrated or pinhole? What’s the difference? For LCLS they are very similar. Need detailed design. Scanning spectrometer or single-shot? Single-shot and scanning. What kind of spectrometer? Crystal or grating? What R&D is needed? Create a PRD giving required specs