Practical Aspects See: 1)http://micro.magnet.fsu.edu/primer/ anatomy/anatomy.htmlhttp://micro.magnet.fsu.edu/primer/ anatomy/anatomy.html 2)http://micro.magnet.fsu.edu/primer/

Slides:



Advertisements
Similar presentations
Chapter 4 Companion site for Light and Video Microscopy Author: Wayne.
Advertisements

© 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
The Microscope.
Microscope Objective Parameters. What do the Numbers on the Objective Mean ?
Basic Illuminating Light Paths and Proper Microscope Alignment E. D. Salmon University of North Carolina at Chapel Hill.
Hand sectioning a mushroom 1)cut a wedge from cap that includes the gills2) Hold the section tightly in your fingers and try to shave off thin longitudinal.
Tutorial on Microscopy September 15, Why the need to study microscopy Why the need to study microscopy? It is a tool complementary to molecular.
Blizard Advanced Light Microscopy club Making friends with your microscope.
THE OPTICAL (LIGHT) MICROSCOPE  It is the most important tool to study of microstructure, despite the fact that more sophisticated electron metallographic.
Stem Cell Instrumentation Foundry (SCIF) Orientation: Microscopy Venu Polineni Research Associate, SCIF University of California, Merced Phone: (559)
Slide 1 t:/PowerPoint/confoc/lect1nu.ppt Purdue University Cytometry Laboratories BMS “Introduction to Confocal Microscopy and Image Analysis” Purdue.
Brightfield and Phase Contrast Microscopy. Microscope: Micro = Gk. “small” + skopien = Gk. “to look at”
Optical Microscopy Lecture 1.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Optics. Thomas Young ( ) Wave Optics Diffraction & Interference Christiaan Huygens ( )
II From “Beam Paths” to the “Microscope” October 2008 Rudi Rottenfusser – Carl Zeiss MicroImaging.
3. Geometrical Optics. Geometric optics—process of light ray through lenses and mirrors to determine the location and size of the image from a given object.
Geometrical Optics and Basic Imaging Light Paths of the Bright Field Microscope E. D. Salmon University of North Carolina at Chapel Hill.
Introduction to Fluorescence Microscopy. Introduction to fluorescence microscopy Fluorescence Widefield Fluorescence microscopes Filters and Dichroics.
Copyright © 2008 Pearson Education Inc., publishing as Pearson Addison-Wesley PowerPoint ® Lectures for University Physics, Twelfth Edition – Hugh D. Young.
Fiber Optics Defining Characteristics: Numerical Aperture Spectral Transmission Diameter.
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt BMS “Introduction to Confocal Microscopy.
Physics 52 - Heat and Optics Dr. Joseph F. Becker Physics Department San Jose State University © 2005 J. F. Becker San Jose State University Physics 52.
MICROSCOPES Light (visible) Fluorescent U-V Electron Monocular
7. Optical instruments 1) Cameras
7. Optical instruments 1) Cameras
Light Microscopy Uses Uses Before you go to the EM Before you go to the EM Quick check Quick check Maybe all you need Maybe all you need Hydrated and living.
Slide 1 t:/classes/BMS524/2002 lectures/524lect2.ppt © J. Paul Robinson - Purdue University Cytometry Laboratories BMS “Introduction to.
Introduction to Microscopy. Objectives Learn to use a compound microscope correctly. Diagram the path of light through a compound microscope. Name major.
Microscope.
Copyright © 2009 Pearson Education, Inc. Chapter 33 Lenses and Optical Instruments.
 J.Paul Robinson - Purdue University Cytometry Laboratories Slide 1 t:/classes/BMS524/524lect1.ppt 8:44 PM BMS “Introduction to Confocal.
Chapter 25 Optical Instruments.
Physics 213 General Physics Lecture Last Meeting: Diffraction Today: Optical Instruments.
Fundamental of Optical Engineering Lecture 3.  Aberration happens when the rays do not converge to a point where it should be. We may distinguish the.
Basic light microscopy
IV Practical Aspects of Lens Design October 2008
Compound Light Microscope
FNI 2B OM 1 Optical Microscopes. FNI 2B OM2 Outline Justification History Components of the Optical Microscope Theory of operation  Basic Microscope.
PHYS 1442 – Section 004 Lecture #22-23 MW April 14-16, 2014 Dr. Andrew Brandt 1 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying.
Background Research. material selection for launching of telescope; must be soft, able to absorb vibration, fit within the appropriate temperature range.
Geometrical Optics Chapter 24 + Other Tidbits 1. On and on and on …  This is a short week.  Schedule follows  So far, no room available for problem.
Slide 1 t:/classes/BMS524/524lect2.ppt © J.Paul Robinson - Purdue University Cytometry Laboratories Lecture 2 The Principles of Microscopy BMS.
Basic Microscopy – An Overview – October 2005 Protistology Course MBL, Woods Hole, MA.
The Microscope.  Spectroscopic Microscope  Light – Compound (Bright field)  Fluorescent  Confocal  Electron- Transmission and scanning.
Break Period – move to lab
Optical microscopy We want to see more details Magnification Resolution Contrast Simple microscope MENA3100, 26/1-10.
Principles and Practices of Light Microscopy II: Brightfield optics, resolution, and aberrations.
(Image: T. Wittman, Scripps) Principles & Practice of Light Microscopy: 2.
Introduction to Light Microscopy
(Image: T. Wittman, Scripps) Introduction to Light Microscopy.
Principles & Practice of
Microscopes Moisey (2009), Optical Microscope [photograph]. Retrieved from
Brightfield Contrasting Techniques Kurt Thorn NIC.
Microscopy.
Veterinary Practice Laboratory Unit 1
Microscope.
25 Optical Instruments Digital Camera with Zoom Lens.
7. Optical instruments 1) Cameras
Microscopy History Compound Light Microscopes Types of Microscopy
Invest. Ophthalmol. Vis. Sci ;45(11): doi: /iovs Figure Legend:
Metamaterials for Curved Lenses Geometric optic analysis of lenses composed of continuous negative index media. UCSD.
Microscope Tutorial.
BMS “Introduction to Confocal Microscopy and Image Analysis”
Safety & Microscopy.
Announcements Lab tonight: planetarium
Microbiology Lab Practices.
LIGHT MICROSCOPY basic
Microscopy.
7. Optical instruments 1) Cameras
Presentation transcript:

Practical Aspects See: 1) anatomy/anatomy.htmlhttp://micro.magnet.fsu.edu/primer/ anatomy/anatomy.html 2) anatomy/specifications.html 3) Murphy: Pgs E. D. Salmon University of North Carolina at Chapel Hill

Homework Problem 5 The light source is a 3-mm square tungsten filament. The design of the illumination system requires that (1) the filament be 300 mm away from the condenser diaphragm, (2) the image of the filament must be in focus at the condenser diaphragm and (3) the filament must be 15-mm square to fill the condenser aperture with light. Assuming the lamp collector lens is an ideal thin lens, determine the focal length, and the position of the collector lens between the lamp filament and the condenser diaphragm. Ans: Eqn 1: M = i/o = 15/3 = 5; i = 5o Eqn 2: i+ o = 300; 5o +o = 300; o = 300/6 = 50; i = 250 Eqn 3: 1/i +1/o = 1/f; 1/250 +1/50 = 1/f; f = mm

Homework Problem 6 A field diaphragm or iris is placed in front of the collector lens as shown for the Koehler illumination system. The field iris is used to control the illuminated area of the specimen. The condenser lens is translated back and forth along the central axis until an image of the field diaphragm is in sharp focus on the specimen. When the opening of the field diaphragm is 20 mm, the image on the specimen must be 2 mm in diameter. In addition, the field diaphragm is placed 160 mm away from the condenser lens. What is the focal length of the condenser needed to meet these requirements? Answer: Eqn. 1): 1/o +1/i = 1/f, or 1/160 +1/i = 1/f and Eqn. 2): M = i/o =.1, so i =.1 *160 = 16 mm Solving Eqn 1 1/160 +1/16 = 1/f; f = 14.5 mm

Homework Problem 7 Indicate “In-focus” or “out-of-focus”for: Field Diaphragm Light Source at: Field Diaphragm____In_____________Out___ Condenser Diaphragm____Out____________In____ Specimen____In____________Out___ Objective BFP ____Out____________In____ Ocular FFP____In_____________Out___ Ocular BFP (Ramdens Disk)____Out____________In____ Retina (or camera detector)____In_____________Out___

Homework 8 Work through the Microscope Illumination Section under Microscope Anatomy at:

Objective Specifications

Why can a high resolution objective cost $4000?: Correction of Geometrical Aberrations Monochromatic: Spherical, Coma, Astigmatism, Distortion, Curvature of Field Chromatic: Longitudinal, Lateral

Spherical Aberration

Coma

Astigmatism

Distortion

Curvature of Field

Chromatic Aberration

Chromatic (and Spherical) Aberrations Corrected by the Achromatic Doublet Chester More Hall Makes the Discovery in 1730, diddles, and John Dolland Learns the Secret, and Patents it in about 1759.

The 3 Classes of Objectives Chromatic and Mono-Chromatic Corrections

Chromatic Correction

Plan Objectives

Apochromat Objectives

Mechanical Lengths

Objective Specifications

Parfocal Distance and Turret Mount

Tube lens and Chromatic Correction: Leica-200mm, in tube lens; Zeiss-160 mm, in tube lens; Olympus-180 mm, in tube lens Nikon-200 mm, in objective

Working Distance of Some Objectives (mm) Zeiss PlanApo100X/1.4 oil……..0.1 Olympus “ “ “ “ …….0.2 Nikon PlanApo 60X/1.4 oil……..1.1 Zeiss PlanApo 40X/1.2 water… Olympus “ 60X “ “ … Zeiss Plan Acro 100X/1 water… Nikon Fl 40X/.75 air…………….0.51 Nikon Fl 40X/.7 LWD air……….2.? Nikon Fl 10X/.30 air…………….10

Importance of Objective NA Light Collection: I ~ NA obj 2 /M tot 2 Lateral Resolution: -Fluorescence: r = 0.61 /NA obj -Trans-Illumination: r = /(NA obj + NA cond )

Objective Immersion Type Dry (no marking) Water (direct)W.WI Water (coverglass)W Korr GlycerolG, Gly OilOil, Oel Multi-immersionImm (Water, glycerol, oil)

Objective Special Use Phase ContrastPh1, Ph2, Ph3 Polarized LightPol, DIC UV fluorescenceU-, U340/380 DarkfieldIris in BFP

Dry Objectives must correct for refractions at air/coverslip interface; Oil immersion Increases NA

Cover Slip (see below) and Slide Thickness: Slide is 1 mm thick; both have n= 1.52 crown glass # 0: mm # 1: mm # 1.5: mm; 0.17 mm for Dry Obj. # 2: mm # 3: mm

Correction Collars for Spherical Aberration

Muli-Immersion and Variable Coverslip Thickness Objectives

Front Element Design in Oil Immersion Objectives

Why Use A Water Immersion Objective

Anti-Reflection Coatings Reduce Scattered Light

nm Uncoated glass n= 1.52 Single layer coating Multilayer coating

Relative Transmission of Objectives (%) Name nm Fluor 40X/ “““ X/0.9 water5688 Planapo 40X/1.2 water

Abbe Condenser

Achromatic Condenser

Aplanatic Condenser

Swing-Out Top Lens Condenser

Ocular or Eyepiece

Ocular Designs

Stage and Eyepiece Micrometers for Microscope Distance Measurements

Projection Oculars

Elements of a Simple Stage

Higher Quality Specimen Stage

Circular stage

FRAP Scope with Cooled CCD Camera

Inverted Microscope Stage

Inverted Microscopes and Micromanipulation

Modern Upright Research Light Microscope (1995) *Bright, High Contrast Optics *Epi-Fluorescence *Phase-Contrast *Polarization *DIC *Diffraction Limited Resolution *Multiple Ports *Auto. Photography *Electronic Imaging- (Video---CCD)