IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results1 Our status, progress and.

Slides:



Advertisements
Similar presentations
Technical Board, 12 July 2005Børge Svane Nielsen, NBI1 Status of the FMD Børge Svane Nielsen Niels Bohr Institute.
Advertisements

Spectrometer Sam Valerio. Shows spectral distribution of a light source in the form of a graph. This specific one in the Imaging Science Center is called.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
Striplet option of Super Belle Silicon Vertex Detector Talk at Joint Super B factory workshop, Honolulu 20 April 2005 T.Tsuboyama.
IFIC, Valencia Charles University, Prague Peter Kodyš, September 14-16, 2004, RD50 – Workshop Florencia1 Laser.
Module Production for The ATLAS Silicon Tracker (SCT) The SCT requirements: Hermetic lightweight tracker. 4 space-points detection up to pseudo rapidity.
ECAL TIMING. 20/04/092 Ratios’ Method Basics Position of pulse maximum parameterized using the ratio of two consecutive samples, i.e., R = A(t)/A(t+1)
CFT Calibration Calibration Workshop Calibration Requirements Calibration Scheme Online Calibration databases.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of double sided silicon micro-strip sensors with a pulsed infra- red laser system for the CBM experiment Pradeep Ghosh 1,2 & Jürgen Eschke.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
NINO RO chip qualification with the laser test system Sakari and Fadmar.
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
1 ALICE T0 detector W.H.Trzaska (on behalf of T0 Group) LHCC Comprehensive Review, March 2003.
Detectors for Light Sources Contribution to the eXtreme Data Workshop of Nicola Tartoni Diamond Light Source.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
First results from the Biocams J. Brunner. Cameras on floor 1 and floor 5 together with an OM and an ADCP Floor 1 –80m above sea floor Floor 5 –270m above.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
AHCAL Electronics. Status Commissioning Mathias Reinecke for the AHCAL developers HCAL main meeting Hamburg, Dec. 10th, 2009.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Peter Kodyš, SCT Week Valencia, Juni 13, Charles University.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept and status of the PSD temperature control - Concept of the PSD analog part.
By: David Gelbendorf, Hila Ben-Moshe Supervisor : Alon Zvirin
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
Jyly 8, 2009, 3rd open meeting of Belle II collaboration, KEK1 Charles University Prague Zdeněk Doležal for the DEPFET beam test group 3rd Open Meeting.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
1 Oct 2009Paul Dauncey1 Status of 2D efficiency study Paul Dauncey.
PMT measurements in Antares Oleg Kalekin on behalf of Antares collaboration VLVnT 2011 Erlangen
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept of the PSD temperature stabilization and control - Upgrade of HV control system.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Development of a pad interpolation algorithm using charge-sharing.
Peter Kodyš, October 10, 2005, DEPFET workshop, Munich, Laser testy – status in Prague1 Peter Kodyš, Zdeněk Doležal, Pavel Řezníček, Zbyněk Drásal, Jan.
C.Lacasta, C.García, S.Martí, U. Soldevila, P.Bernabeu, C.Solaz, D.Rodríguez, JV. Civera, D. Santoyo, A. Platero, F. Gonzalez Valencia ATOPE Meeting: Xmas.
A novel two-dimensional microstrip sensor for charge division readout D. Bassignana, M. Lozano, G. Pellegrini CNM-IMB (CSIC) M. Fernández, R. Jaramillo,
A novel two-dimensional microstrip sensor with charge division readout M. Fernández, R. Jaramillo, F.J. Muñoz, I. Vila IFCA (CSIC-UC) D. Bassignana, M.
ADC values Number of hits Silicon detectors1196  6.2 × 6.2 cm  4.2 × 6.2 cm  2.2 × 6.2 cm 2 52 sectors/modules896 ladders~100 r/o channels1.835.
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
Noise results from SR1 combined SCT barrel tests Summary of some initial results Alan Barr, UCL Pepe Bernabeu, Valencia.
February 10, 2009, G-APD Workshop, GSI Darmstadt1 APD Laser Test Setup Charles University, Faculty of Mathematics and Physics, Institute of Particle and.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
QA Tests Tests for each sensor Tests for each strip Tests for structures Process stability tests Irradiation tests Bonding & Module assembly Si detectors1272.
1 June 29, 2004, SCT Week SCT Simulation for CTB2004 Zdenka Broklova, Peter Kodys, Carlos Escobar Special thanks to Thijs Cornelissen, Grant Gorfine, Pavel.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Development of Multi-Pixel Photon Counters (1)
Analysis of LumiCal data from the 2010 testbeam
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Monitoring system commissioning
The Silicon Drift Detector of the ALICE Experiment
BESIII EMC electronics
Peter Kodyš, Zdeněk Doležal, Jan Brož,
Setup for testing LHCb Inner Tracker Modules
The MPPC Study for the GLD Calorimeter Readout
Gain measurements of Chromium GEM foils
DAQ and visualization software
Presentation transcript:

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results1 Our status, progress and results are summarized on IFIC – Valencia July 16, 2004 Peter Kodys With help from: Carlos Escobar and next: Vaso, Salva, Sergio, Pavel, Zdenek, Carlos L., Peter W.P., Carmen, Pepe, Pablo, Luis, Paco (cooperation of IFIC Valencia and CU Prague)

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results2 STATUS Laser Spot on Threshold Scan (No focused spot, two channel signal, first historical detection of laser on SCT module in IFIC)  Stable mechanical arrangement.  Laser detection in only one side (metal back side of detectors – no transparent for light).  Strip position detection working up to 1 minute.  Few method of focusing was tuned.  Automatic focusing done up to 20 minutes with precision 40um in z and 4 um in x.  The bond mixing test done up to 30 minutes per detector – test for production modules.  The channels from mask file tested independently using two methods.  The channels from external file tested.  No effect of interference between chip channels is observed.  Pulse shape reconstruction done.  Punch through (pin hole) channels test for response done.  Testing at low temperatures was tuned and is done up to –20 deg in chillers (4 deg in T-hybrid) in dry air or nitrogen  Automatic logbook generate and saved with all important information

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results3 Scheme of arrangement: Laser parameters and light interaction with silicon:  Laser energy of photon: eV  Wavelenght of light: 1060 nm  Real part of dielectric const.:  Imag part of dielectric const.:  Index of refraction:  Imag part of index of refr.: 0  Absorption coeficient: cm·¹  0.6mm Si: 35.2%  0.6mm Si: 24%  0.6mm Si: 40.8%  0.27mm Si:60.35% back side of Si reflected - metalized  0.27mm Si:0 % back side of Si reflected - metalized  0.27mm Si:39.65% back side of Si reflected - metalized

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results4 LASER SPOT TUNNING 1 Main conclusion: there is possibility to tune laser focusing to smallest spot using reflectivity from strip metal material to measure decreasing of signal from main testing strip, sensitivity of focusing of our type of laser output is very high, focus range is less 50 µm (from factory is declared good focus range about 1 mm). Auto focus algorithm: ~ 6 minutes - Based on TriggerBurst Scans in range of variable Z (dynamic focus) - Dynamic Threshold selection based on strip output - In each Z and X distance, we acquire Trigger Burst and Median Charge data. Then, we found the minimum in a 3D plot

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results5 LASER SPOT TUNNING 2 Main conclusion: method independent of starting point in range 3mm from focus give result up to 20 minutes, method use quick scan to find mid of strip in two position (1 minute per position) and find minimum between them with precision 200um. Minimum exist because reflect from strip metal material. Then start fine 2D scan in range 400 x 16 um to find focus point. Auto focus algorithm: ~ 20 minutes Find mid of channel and current strip pitch Scan in z to find a minimum (3mm range)Scan in x and z to find a minimum (400 x 16 um range)

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results6 Pulse shape reconstruction vs. interstrip position of laser spot was done. Also quality of laser spot was measured used fit of edges on metal conductive strip and was sigma um, strip width is um. Laser spot profile reconstruction with sigma ~ 3.3um Scan of medians in x uncorrected for start point shift Scan of medians in x – corrected, in middle part is response decreasing based on reflection of light from strip PULSE SHAPE RECONSTRUCTION

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results7 PULSE SHAPE RECONSTRUCTION Laser spot reconstruction Delay vs. x from pulse shape fitPeaking time vs. x from pulse shape fit 2D graph of medians in time shift vs. x, strip metal part is on point 0 where practically whole light beam is reflected out Pulse shape fit for all x positions Strip position

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results8 RE-BONDING SOME CHANNELS In the results, you can see the differencies... We re-bond some bonds to different positions to look dependence of chip channel stability base of neighbored high powered channel. The channels are detected in unexpected positions. We can calculate the bond mixing with presition. This is a good test to check the bonds. Channels re-bonded

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results9 CHANNEL POSITION SCAN 1 (PRODUCTION TEST) We use the re-bond module to do all test, so we found in this quick test the incorrect bounded channels. This test is preliminary and we are working on it. Now, we have good results in ~30 min per side (full channels test). Dead Chip Channel signal from Laser

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results10 CHANNEL POSITION SCAN 2 (PRODUCTION TEST) Response from trigger burst at some threshold over noise threshold, we expect response in range counts This test is for checking of response from all channels using laser spot, neighbours should have not additional response Results in ~30 min per detector (full channels test), 2 hours per module with 4 detectors. Using threshold at each channel decreasing of median from noise (threshold without laser spot invoking) 6 bad channels (4 dead and 2 noised) Special test of only bad channels response from mask file is tuned and is done.

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results11 BAD CHANNEL TEST (FOR PRODUCTION MODULES TEST) This test is for checking of response from bad channels based on mask file and compare it with neighbours channels Testing channels normalized to 1 used their neighbours: average of them was reference value, two channels shows some response but in very high level – un-trimm channels Testing channels (red) with their neighbours (blue), up: response – noise, bottom: response from channels and noise (yellow/green) Map of testing bad channels on module

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results12 PUNCH THROUGH (PIN HOLE) CHANNEL TEST This test is for checking of response from special channels and compare it with neighbours channels Testing channels normalized to 1 used their neighbours: average of them was reference value Testing channels (red) with their neighbours (blue), up: response – noise, bottom: response from channels and noise (yellow/green) Testing channels – histogram of normalized channels

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results13 STABILITY AND TEMPERATURE DEPENDENCES For many tests we need measurement with untrimmed channels (for measurement of un-trimable channels) and unmasked channels (for bad channel tests). For measurement of stability of measurements we use outer unirradiated module with Hamamatsu detectors in dry air atmosphere. Stability: 1.Measurement of channels response used median point from threshold scan with precision ±5mV 2.Differences between channels (no trimming) are ±17 mV (± 10% of signal from laser) 3.Differences between measurements are ±3 mV (± 2% of signal from laser) Temperature dependences: Noise is not depended from temperature in range 6 to 29 °C on Thybrid Response from channels depend from Thybrid: (2.4 ±0.3)mV/°C

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results14 HOW TO TEST MODULES USING SCTDAQ AND SPECIAL FUNCTIONS After to set position about 2mm or less from focused point you can find in trigger burst scan laser spot Typical window after an start laser tests: set right side and initialise L1A Laser Test mode (without calibration pulse)

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results15 HOW TO TEST MODULES USING SCTDAQ AND SPECIAL FUNCTIONS Computer: Silab05, starting commands:.x ST.cpp(); MoveZ(CloseToFocusPoin); Push Button: ´Top/Back side module 0 testing´ Push Button: ´Initialization L1A´ Push Button: 1 – 8 to start test you want To lost laser signal try: Push Button: ´Move TimeBin …´ 1a, 7, 8 – working OK in un-focusing.2 – 2.0mm 4. Auto Focus – is best and quick 6. Median charge scan need setting of delays using delay wires and before scan you must find good focus point and start from it All test produce log book text file in dir ´data´and program:.x ShowChTestGraphs(FileName,RunNo,SaveGraphs,TypeAnalysis); help you with interpretation of results of main type of tests. After test, my recommendation, always to restart ROOT session

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results16 PHOTOS 1 First arrangement of workspace Module in test box with window for laser spot, optical fibre for laser light (yellow cover), insulated plastic support for module Laser end with focusing lens above module sensor Black box with 2D stages inside and chiller below them

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results17 PHOTOS 2 Final arrangement of workspace Black box with module box connecting to cooling and DAQ electronics General view to laser tests workplace with black box (left) with 2D stages inside and chiller below them, readout electronics (right) and DAQ computer Block of connectors for in/out puts of cooling, air or nitrogen, optical fibre of laser light and command wires of position stages

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results18 PHOTOS 3 Final arrangement of workspace Position stages arrangement Laser end with focusing lens above module sensor and module test box with two windows for testing of both sensors (one is closed for save cool dry atmosphere inside) Production of dry cool air for module

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results19 General summary 1 STATUS OF LASER TEST WORKPLACE IN IFIC VALENCIA Laser Spot on Threshold Scan (No focused spot, two channel signal, first historical detection of laser on SCT module in IFIC)  Stable mechanical arrangement.  Laser detection in only one side (metal back side of detectors – no transparent for light).  Strip position detection working up to 1 minute.  Few method of focusing was tuned.  Automatic focusing done up to 20 minutes with precision 40um in z and 4 um in x.  The bond mixing test done up to 30 minutes per detector – test for production modules.  The channels from mask file tested independently using two methods.  The channels from external file tested.  No effect of interference between chip channels is observed.  Pulse shape reconstruction done.  Punch through (pin hole) channels test for response done.  Testing at low temperatures was tuned and is done up to –20 deg in chillers (4 deg in T-hybrid) in dry air or nitrogen  Automatic logbook generate and saved with all important information

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results20 CHANNEL POSITION SCAN (FOR PRODUCTION MODULES TEST) Response from trigger burst at some threshold over noise threshold, we expect response in range counts This test is for checking of response from all channels using laser spot, neighbours should have not additional response Results in ~30 min per detector (full channels test), 2 hours per module with 4 detectors. Using threshold at each channel decreasing of median from noise (threshold without laser spot invoking) 6 bad channels (4 dead and 2 noised) Special test of only bad channels response from mask file is tuned and is done. General summary 2

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results21 BAD CHANNEL TEST (FOR PRODUCTION MODULES TEST) General summary 3 This test is for checking of response from bad channels based on mask file and compare it with neighbours channels Testing channels normalized to 1 used their neighbours: average of them was reference value, two channels shows some response but in very high level – un-trimm channels Testing channels (red) with their neighbours (blue), up: response – noise, bottom: response from channels and noise (yellow/green) Map of testing bad channels on module

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results22 General summary 4 PUNCH THROUGH (PIN HOLE) CHANNEL TEST This test is for checking of response from special channels and compare it with neighbours channels Testing channels normalized to 1 used their neighbours: average of them was reference value Testing channels (red) with their neighbours (blue), up: response – noise, bottom: response from channels and noise (yellow/green) Testing channels – histogram of normalized channels

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results23 General summary 5 Pulse shape reconstruction vs. interstrip position of laser spot was done. Also quality of laser spot was measured used fit of edges on metal conductive strip and was sigma um, strip width is um. Scan of medians in x – corrected, in middle part is response decreasing based on reflection of light from strip 2D graph of medians in time shift vs. x, strip metal part is on point 0 where practically whole light beam is reflected out Pulse shape fit for all x positions Strip position Peaking time (up) and delay (down) vs. x from pulse shape fit PULSE SHAPE RECONSTRUCTION

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results24 General summary 6 LASER SPOT TUNNING Main conclusion: method independent of starting point in range 3mm from focus give result up to 20 minutes, method use quick scan to find mid of strip in two position (1 minute per position) and find minimum between them with precision 200um. Minimum exist because reflect from strip metal material. Then start fine 2D scan in range 400 x 16 um to find focus point. Autofocus algorithm: ~ 20 minutes Find mid of channel and current strip pitch Scan in z to find a minimum (3mm range) Scan in x and z to find a minimum (400 x 16 um range) Detail how sharp is focus point of laser spot

IFIC - Valencia Peter Kodys, July 16, 2004, internal workshop, status and results25 STABILITY AND TEMPERATURE DEPENDENCES For many tests we need measurement with untrimmed channels (for measurement of un-trimable channels) and unmasked channels (for bad channel tests). For measurement of stability of measurements we use outer unirradiated module with Hamamatsu detectors in dry air atmosphere. Stability: 1.Measurement of channels response used median point from threshold scan with precision ±5mV 2.Differences between channels (no trimming) are ±17 mV (± 10% of signal from laser) 3.Differences between measurements are ±3 mV (± 2% of signal from laser) Temperature dependences: Noise is not depended from temperature in range 6 to 29 °C on Thybrid Response from channels depend from Thybrid: (2.4 ±0.3)mV/°C General summary 7