Photo Acoustic Effect And its usage for spectroscopy.

Slides:



Advertisements
Similar presentations
waves are carriers of energy
Advertisements

Cloud Radar in Space: CloudSat While TRMM has been a successful precipitation radar, its dBZ minimum detectable signal does not allow views of light.
waves are carriers of energy
Foundations of Medical Ultrasonic Imaging
Opto-Acoustic Imaging Peter E. Andersen Optics and Fluid Dynamics Department Risø National Laboratory Roskilde, Denmark
Lecture 12 Content LIDAR 4/15/2017 GEM 3366.
Waves and Light. A wave is a pattern that moves. A wave is a pattern that moves. As the pattern moves, the medium may “jiggle”, but on average it stays.
Laser Anemometry P M V Subbarao Professor Mechanical Engineering Department Creation of A Picture of Complex Turbulent Flows…..
EE 5340/7340, SMU Electrical Engineering Department, © Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be.
ECE 501 Introduction to BME
Ultrasound Medical Imaging Imaging Science Fundamentals.
Atomic Absorption Spectroscopy (AAS)
Physics 102 Waves Moza M. Al-Rabban Professor of Physics Lecture 5 Traveling Waves March 6, 2006 Lecture 5 Traveling Waves March 6, 2006.
Absorption and emission processes
Phy 202: General Physics II Ch 16: Waves & Sound Lecture Notes.
Fiber-Optic Communications James N. Downing. Chapter 2 Principles of Optics.
Electro-Optical Systems The almost last lecture of Weapons Class.
Ultrasound Imaging Atam Dhawan.
Phy 212: General Physics II
Reports of optical fiber communication systems
ESAT 3640 Therapeutic Modalities
Solar Energy & the Atmosphere
Ultrasound Physics Sound is a mechanical, longitudinal wave that travels in a straight line Sound requires a medium through which to travel Ultrasound.
Basic RADAR Principles Prof. Sandra Cruz-Pol, Ph.D. Electrical and Computer Engineering UPRM.
IR – Infrared Spectroscopy. What is IR Spectroscopy? Infrared spectroscopy is the analysis of infrared light interacting with a molecule. IR spectroscopy.
 Describe the image  ◦ What is it? ◦ What does it measure? ◦ How does it work?
Parameters, pulse parameters, attenuation, and resolution.
P6 – The Wave Model of Radiation
Chapter 3 Light and Matter
Waves S8P4: Students will explore the wave nature of sound and electromagnetic radiation.
Photo acoustic spectroscopy of beta amyloids - research overview Group Meeting February 08.
Objectives Explain how radiant energy reaches Earth.
Solar Radiation and Insolation Incoming solar radiation:
PHYSICS DEPARTMENT.
Display of Motion & Doppler Ultrasound
Hyperbolic Heat Equation 1-D BTE assume Integrate over velocity space assuming that  is an averaged relaxation time (4.63a) (4.64) or.
Lecture 2 INTRODUCTION TO SPECTROMETRIC METHODS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Radiation Fundamental Concepts EGR 4345 Heat Transfer.
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Light Wave Behaviors and Properties Chart (pg. 76)
ACOUSTIC THEORY  WAVE VELOCITY  ACOUSTIC IMPEDANCE  REFLECTION AND TRANSMISSION  REFRACTION  RADIATION  ATTENUATION.
EQ: How do different mediums affect the speed of sound?
Introduction to Thermal Physics
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Spectrophotometer.
Lecture 21-22: Sound Waves in Fluids Sound in ideal fluid Sound in real fluid. Attenuation of the sound waves 1.
-Plasma can be produced when a laser ionizes gas molecules in a medium -Normally, ordinary gases are transparent to electromagnetic radiation. Why then.
LASER LASER stands for LIGHT APLIFICATION by STIMULATED EMISSION of RADITIONS First laser was constructed by Maiman Laser action has been obtained with.
University of Kurdistan Food Quality Evaluation Methods (FQEM) Lecturer: Kaveh Mollazade, Ph.D. Department of Biosystems Engineering, Faculty of Agriculture,
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
1.1 What’s electromagnetic radiation
Introduction Instruments designed and fabricated at the Desert Research Institute, Reno Emphasis on the Integrating Nephelometer for scattering measurements.
Chapter 4- Sound, Light, and Heat _____________ is how high or low a sound is. Pitch.
Energy in Earth Processes Unit 4. What is Energy? Energy is _____________________________ Everything that is done in the universe involves the _______________________________.
Speed of Waves. Review Wavelength CREST TROUGH REST amplitude Wavelength.
Thermal Energy 11/1/2011. What is thermal energy? Thermal energy is also known as heat and is the kinetic energy of all the molecules in a material. If.
Mechanical Waves Wave Characteristics Say What?! Wave Examples Vocabulary $ $ $ $ $ $ $ $ $ $
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Properties of Light Waves, particles and EM spectrum Interaction with matter Absorption Reflection, refraction and scattering Diffraction and polarization.
Quantum Mechanical Model of the Atom
Spectrophotometer Dr . S. Jayakumar.
Behavior of Waves.
Photo acoustic tomography
Sound COS: #18 Use Models to determine how light and sound waves differ in how they are absorbed, reflected, and transmitted through different media.
Fourier Transformation Infra-red
Behavior of Waves Notes
Photon Physics ‘08/’09 Thijs Besseling
Lab Equipment.
Presentation transcript:

Photo Acoustic Effect And its usage for spectroscopy

Photo-Acoustic effect principle Modulated Light Local Heating Absorption: I a = αI 0 Thermal Expansion Pressure Wave = Sound wave Absorption

Discovery: A.G.Bell (1880) Sun Light Rotating disc Modulated light Thin Disk Sound

Example applications of PA effect Characterization of solid materials Separation between different gases and measuring gas concentration Glucose level monitoring in blood Imaging of blood vessels Concentration of textile dyes Concentration of soot particles in diesel engines

PA effect – wave equation Acoustic velocity => temporal delay Volumetric Thermal Expansion = Change in volume with Temperature: Specific heat = Heat energy required to increase temperature by  T Absorption coefficient [cm -1 ]: Amount of light energy absorbed in the sample. Also affects the light beam itself

Light beam considerations for PA experiment PA amplitude depends on light intensity derivative -> light should be modulated\pulsed Pulsed light is preferred:  Low average intensity (can use very short pulses)  High derivative of CW beam requires high frequency – attenuated by most liquids Pulse requirement:  Short rise time -> higher derivative  Short pulses – lower average energy (eye-safety)  Narrow spatial beam

Light Beam properties Temporal Spatial – high absorption Semi-spherical wave Spatial – low absorption Semi-cylindrical wave

Pressure wave propagation FDM simulation results High absorption: α=11.6 [cm -1 ] No reflections, no dispersion or medium attenuation

Pressure wave propagation FDM simulation results Low absorption: α=0.9 [cm -1 ] No reflections, no dispersion or medium attenuation

Effect of absorption coefficient Pressure wave at fixed location (FDM simulation)

Effect of spatial beam diameter

Additional considerations For FDM simulation Reflections from cuevette and pressure wave generation in cuevette Dispersion of acoustic wave Medium MTF PZT’s spatial response Scattering effects

Pros & Cons for PA usage for spectroscopy in the eye Pros:  Doesn’t depend on transmission or reflection of the light beam – can work with opaque materials, higher immunity to scattering effects  May work in various wavelengths  Signal depends on various characteristics of medium in addition to absorption (heat capacity, acoustic velocity) that may be used to improve detection  Depends on light intensity derivative – may be used with short pulses that have low average intensity  Option to work in wavelength where good optical broad- band detectors are hard to find

Pros & Cons for PA usage for spectroscopy in the eye Cons:  Requires to find specific wavelength in which there’s a good separation between signal of target proteins and other proteins\solvent  Requires a high-quality light source: pulses with very short rise time