Alamance Regional Cancer Center 2012

Slides:



Advertisements
Similar presentations
Surface contour scanning system
Advertisements

How is radiotherapy given Radiotherapy can be given in two ways: from outside or inside the body. External radiotherapy is the most common method of treatment.
The Power And Speed Of Digital Imaging. The Power and Speed of Digital Imaging Digital or Conventional? Vs.
Beam Therapy Equipment 2 Linear Accelerator Head.
RapidArc plan verification using ArcCHECK™
Awareness - Information - Understanding. What is PEARL? Simply – A Virtual Linac on your desk  communicate Linac machine size and sounds to patients.
In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
The Tomotherapy Experience at Advocate Good Samaritan Hospital
10th Annual Lung Cancer Conference Radiation Oncology
Experience, Expertise and a Commitment to Excellence™
Copyright ©2008 Accuray, Incorporated. All rights reserved E CyberKnife ® Robotic Radiosurgery System Radiosurgery System Comparisons.
Department of Radiation Oncology. Facilities Available 3 Linear Accelerators Namely 1. Novalis Tx with 2 photon and 6 Electron beems. OBI and RPM – Gating.
CONTENTS ARE CONFIDENTIAL ORBITAL THERAPY, LLC Dedicated, self-shielded device for breast.
Department of Radiation Physics, Royal Derby Hospital
Varian _ Dynamic Targeting TM Image-Guided Radiation Therapy Scott Johnson, PhD Varian Medical Systems Palo Alto, California Varian _.
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
Computed Tomography RAD309
University of Idaho Research Colloquium Microwave Electron Linear Accelerators for Cancer Therapy and Non-Destructive Testing: History, Application & Theory.
tomos = slice, graphein = to write
Part 1 Introduction to Radiotherapy and External Beam Radiation Deepak Khuntia, MD Vice President, Medical Affairs Varian Medical Systems.
Stereotactic RadiologyStereotactic Radiology By: Jeremy Lishner.
WELCOME!!! FDA & MITA RT Meeting
Volumetric Modulated Arc Therapy (VMAT)
Conventional and Computed Tomography
Basic principles Geometry and historical development
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
Department of Radiation Oncology Henry Ford Health System
Challenges for TPS Chunhua Men Elekta Software, Treatment Planning System BIRS Workshop Banff, Canada 3/12/2011.
Autonomous Robotics in Medicine Michael Saracen February 11, 2009.
Safety Consideration Software limits on robot controller Limit switches on the robot “wrist” to prevent excess rotations Limit switches on the vertical.
External Beam Radiation Therapy Special Procedures
The external beam radiotherapy and Image-guided radiotherapy (2)
The days before Treatment
AUTHORS (ALL): Huang, Xiaoyan 1, 2 ; Kuan, K M 2 ; Xiao, G L 2 ; Tsao, S Y 3, 2 ; Qiu, X B 2 ; Ng, K 2. INSTITUTIONS (ALL): 1. Radiation Oncology, Sun.
Radiation Protection in Radiotherapy
1 4D: Adaptive Radiotherapy & Tomotherapy Bhudatt Paliwal, PhD Professor Departments of Human Oncology & Medical Physics University of Wisconsin Madison.
Institute for Advanced Radiation Oncology
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Integrating the Health Care Enterprise- Radiation Oncology Use Case: In Vivo Patient Dosimetry Editor: Juan Carlos Celi - IBA Reviewer: Zheng Chang – Duke.
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
F. Foppiano, M.G. Pia, M. Piergentili
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Part No...., Module No....Lesson No
Introduction to Radiation Therapy
Tomotherapy Tomo는 tomotherapy사가 개발하였고 현재는 accuray사가 인수하여 운영하고있다. 이세림
© 2013 MITSUBISHI HEAVY INDUSTRIES, LTD. All Rights Reserved. An example of Technical Innovation Cascade Dynamic Tracking Radiation Therapy System US-Japan.
Applications of electron linear accelerators for radiotherapy
Carmel McDerby Clatterbridge Centre for Oncology, Merseyside,UK
Title of the presentation X-ray Therapy Systems Calibration Systems X-Ray Irradiators Image Guided Micro Irradiators Xstrahl Medical Systems Xstrahl Research.
Treatment Machines for External Beam Radiotherapy
Pei Hailong X-RAD 225CX/SMART COMMISSIONING, QA AND FACILITIES MANAGEMENT.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Treatment Chart Record of patients radiation therapy history. Must contain: History and diagnosis Rationale for treatment Treatment plan Consent Documentation.
Martin J Murphy PhD Department of Radiation Oncology
Kasey Etreni BSc., MRT(T), RTT, CTIC
Extending intracranial treatment options with Leksell Gamma Knife® Icon™ Key Statements from Customer Perspective by University Medical Centre Mannheim.
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Linac Commissioning Overview
Insert tables Insert figure
Radiation Oncology New Techniques + Technologies
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Image–Guided Radiation Therapy for Non–small Cell Lung Cancer
Basic principles Geometry and historical development
Novalis Frameless Radiosurgery
Chapter 17 Intensity-Modulated Radiation Therapy
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

Alamance Regional Cancer Center 2012 Varian TrueBeam Alamance Regional Cancer Center 2012

Varian TrueBeam

Why Varian TrueBeam? New platform technology Improved imaging Efficiency Fast and precise Upgradability Most reliable equipment Unlocks treatments Enhanced patient comfort

Varian TrueBeam

New Beam Generation System All new accelerator guide Variable energy switch Simplified and integrated bend magnet New energy/foil carousel and target system Real-time electron gun gating Maximum flexibility in dosimetry <5 MU/min up to 2400 MU/min

New Beam Generation System The TrueBeam system has been designed from the ground up to optimize radiotherapy and radiosurgery Delivers powerful cancer treatments with pinpoint accuracy and precision Seamless integration of treatment, imaging and motion management

Radically Different Future Designed to optimize radiotherapy and radiosurgery Integrates and choreographs powerful imaging and treatment systems Unparalleled accuracy Unlocks new treatment options Allows patients to receive radiation with less treatments Treats new cancers that were previously untreatable

More Treatment Options Provide more options for treating complex cancer cases including lung, breast, liver, abdomen, head and neck IMRT, IGRT, RapidArc, Gated RapidArc, SBRT, SRS

Gated RapidArc Next evolutionary step Compensates for tumor motion Expands application of RapidArc treatments to moving tumors Enables fast treatments of tumors that move with respiration Minimizes exposure to healthy tissues

Gated RapidArc

Multiple Energy Support 6 X-ray energies 8 electron energies Tailor treatments to individual patients Select optimal energy for specific clinical need The TrueBeam system has been completely redesigned and is fully customizable with seven flat-field X-ray energies and two flattening filter free energies(High-Intensity Mode), and gives you the ability to choose the number of electron energies from zero to eight. Additionally, you can do energy upgrades in the field without a guide change, giving you unmatched versatility. You can buy what you need now and add more later or exchange energies if appropriate. You can now tailor your radiation treatment program almost without limitation. This type of flexibility can only be found in the TrueBeam system.

Improved CBCT Quality Overall, better image uniformity Cupping artifact has been minimized - apparent when performing window and level Improvement in the skin line definition Better HU accuracy under all conditions

Imaging on Demand Higher capacity X-ray tube Acquire a radiograph, CBCT image, or perform fluoroscopy, anytime Automated filter management Variable collimation

New Standards in Accuracy Mechanical and Imaging Isocenter Accuracy < 0.75 mm Gantry rotational: < 0.3 degrees Collimator rotational: < 0.5 degrees

Submillimeter Couch Accuracy Compensates for mechanical deflection Rotational accuracy for patient positioning 0 to + 6 degrees: < 0.4 degrees Spatial translational accuracy for patient positioning + 5 cm shift: < .5 mm

Unrivaled Treatment Precision All within 10 milliseconds Accuracy in increments of less than a millimeter Submillimeter alignment for imaging and treatment isocenter

50 One button image acquisition and full automation of beam delivery make treatments 50% faster* Changing imaging procedures and protocols is simple and fast Position and treat in less time than RapidArc benchmark % Faster

TrueBeam™ Treatment Console Single source 4 computers and monitors down to single computer and 2 monitors Future New technology easily integrated with TB

= Fast and Precise Synchronized Fast & Precise Treatments Imaging & Delivery Fast & Precise Treatments

Enhanced Image Guidance Simplified, Automated Imaging Modes Image Acquisition during Treatment—kV and MV Respiration synchronized kV and MV Imaging

TrueBeam

TrueBeam

Enhanced Patient Comfort

Built with Patient Comfort in Mind Quiet operation provides for more comfortable environment Shorter treatment times, less interruption to patient’s daily lives Music can be played during treatments to increase patient comfort

Enhanced Patient Interaction Constant interaction between the patient and therapist New communication system enables the therapist to monitor the patient from outside the treatment room

Allow More Time with Patient Guided workflow Streamlined tasks Prompted and predicted next steps Common user interface for Console, Pendant and Couch controls

Why Varian TrueBeam?

Varian 2100C Elekta Infinity TrueBeam Shaping Cerrobend Blocks MLCs Imaging Radiographic films taken and processed. Time. Poor image quality. OBI-CBCT/kV images. IGRT-Image Guided Radiation Therapy. OBI- CBCT/kV images. Precision Only 3-D and simple treatments available due to manual blocking requirement Offers MLCs, but No FFF energies MLCs , image quality and FFF energies allows SBRT, SRS and Rapid Arc treatments Speed of Treatment Slow due to manual blocking. 600MU/min Std speed for IMRT and Arc Therapy, but No FFF capability State-of-the-art platform, SBRT and SRS speed using 2400 MU/min Energies Up to 7 Energies from 4 to 25 Mv 8 Electron Energies 5 Flattened Photon Energies Fast High Intensity Mode–6X FFF: max ~1400 MU/min–10X FFF: max ~2400 MU/min Taking films allows more time for patient movement. Elekta has developed its Gamma Knife for Stereotactic Radiosurgery. Varian’s new platform allows for energies to be switched or added with software upgrades only. Allows for future technology to be added w/software vs hardware additions. Other companies are usually trying to catch up w/Varian’s technology. Varian systems are typically working for 15-20 years. The useful life of systems is usually 8-12 years.

Main Differences Varian 2100C Elekta Infinity TrueBeam Retired platform Platform comparable to Varian’s C series. New platform allowing software enhancements to extend product life to the upper limit of typical. Imaging poor quality due to mV imaging No High Intensity energies for SBRT/SRS. High Intensity energies Full 1st digital linear accelerator intro 1985 Elekta no fully integrated system. TPS is 3rd party First linear accelerator developed with Stanford in 1959. Dedicated to oncology. Largest oncology specific software provider of fully integrated radiotherapy systems. Taking films allows more time for patient movement. Elekta has developed its Gamma Knife for Stereotactic Radiosurgery. Varian’s new platform allows for energies to be switched or added with software upgrades only. Allows for future technology to be added w/software vs hardware additions. Other companies are usually trying to catch up w/Varian’s technology. Varian systems are typically working for 15-20 years. The useful life of systems is usually 8-12 years.

Thank you for your support. Questions?