In this contribution we present a new automatic procedure for background correction that, for the first time, can be successfully applied in both isocratic.

Slides:



Advertisements
Similar presentations
Instrumental Analysis
Advertisements

Infrared Spectroscopy A.Why are we doing this experiment? 1)Infrared spectra tell us only a limited amount about a transition metal complex 2)In very simple.
Analysis of the Visible Absorption Spectrum of I 2 in Inert Solvents Using a Physical Model Joel Tellinghuisen Department of Chemistry Vanderbilt University.
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
Yu. I. BARANOV and W. J. LAFFERTY Optical Technology Division Optical Technology Division National Institute of Standards and Technology, Gaithersburg,
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Calibration Methods Introduction
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
Results Initial chromatographic conditions [Figure 2a caption] for the separation of the degradation products of aspirin were problematic due to the long.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
17.1 Mass Spectrometry Learning Objectives:
Lecture 6. FT-IR and Raman Spectroscopy. FT-IR Analytical infrared studies are based on the absorption or reflection of the electromagnetic radiation.
Lecture 8. GC/MS.
Chromatography.
In carbon-13 NMR, what do the number of peaks represent?
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Chromatographic detectors for Liquid Chromatography.
Mobile Phase pH Analyte pK a Shift Lecture 4 Yuri Kazakevich Seton Hall University.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Lecture 3 INFRARED SPECTROMETRY
CALIBRATION METHODS.
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
MultiSimplex and experimental design as chemometric tools to optimize a SPE-HPLC-UV method for the determination of eprosartan in human plasma samples.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Qualitative Data Analysis. 2 In This Section, We Will Discuss:  How to load data files.  How to use Signal Options for data display.  How to apply.
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Synchronous map Asynchronous map Order of spectral changes: 1)1654 cm-1 (  -helix) 2) 1641, 1594 cm -1 (disordered structures, COO - ) 3) 1675, 1616 cm-1.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
HPLC – High Performance Liquid Chromatography
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
IL Sustainable Technology Center (ISTC) Tour (20 points)
Lecture 11 IR Theory Next Class: Lecture Problem 4 due Thin-Layer Chromatography This Week In Lab: Ch 6: Procedures 2 & 3 Procedure 4 (outside of lab)
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chapter 28 High Performance Liquid Chromatography.
HPLC.
FTS Studies Of The Isotopologues Of CO 2 Toward Creating A Complete And Highly Accurate Reference Standard Ben Elliott, Keeyoon Sung, Charles Miller JPL,
An Experimental Approach to the Prediction of Complete Millimeter and Submillimeter Spectra at Astrophysical Temperatures Ivan Medvedev and Frank C. De.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Lecture 8 Peak Parameters and Quantitative chromatography
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
EQUIPMENT and METHOD VALIDATION
Maggi Tebrake– Early Pharmaceutics & Technology, 3M Health Care Ltd, Loughborough Lindsey Gunby– Industrial Placement Student (EP&T ), 3M Health.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
UV/VIS SPECTROSCOPY.
LIQUID CHROMATOGRAPHY
Chromatography- TLC & HPLC
Chem. 133 – 5/11 Lecture.
High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography HPLC
Chem. 31 – 11/1 Lecture.
HPLC detectors Pharmawiki 11/18/2018.
Lecture 10 IR Theory This Week In Lab: Ch 6 PreLab Due
Chromatography Daheeya Alenazi.
Transferring LC-UV to LC-MS.
INFRA RED SPECTROSCOPY
Presentation transcript:

In this contribution we present a new automatic procedure for background correction that, for the first time, can be successfully applied in both isocratic and gradient on-line reversed phase LC-FTIR. The proposed approach uses an eluent spectral reference data set and it is based on the assumption that using characteristic absorptions of the eluent. An eluent spectrum can be calculated from the reference matrix. This eluent (background) spectra is then subtracted from the spectra containing the eluting analyte. Based on this approach highly accurate subtraction of the eluent absorption is achieved at minimal computational cost. The method solves two problems simultaneously: the background correction in gradient HPLC and also correct possible changes in the intensity of the absorption spectra of the eluent during analyte elution. A tool for automated background correction in on-line gradient LC-FTIR Guillermo Quintás, Bernhard Lendl* Inst. of Chemical Technologies and Analytics, Vienna University of Technology, Vienna, Austria. Getreidemarkt 9-164, A-1060 Vienna, Austria. *: Phone: Fax: BACKGROUND SPECTRAL CHANGES DURING A GRADIENT ELUTION The developed background spectral subtraction approach it is based on the use of a Reference Spectra Matrix (RSM) of different mobile phase solutions covering a range of compositions. Then, according to the composition of the eluent in every sample spectra, the spectra of the eluent is calculated as a linear combination of two spectra included in the RSM and subtracted from the sample spectrum. 1.The absorption bands from water and acetonitrile change their relative intensity and shape with their relative concentrations, and so, the mobile phase spectra can not be directly calculated from the spectra of the pure compounds. 2.Acetonitrile presents three intense absorption bands at 1442, 1416 and 1377 cm -1 with relative intensities depending on the water relative concentration. On the other hand, it can also be seen two sharp bands at 2252 and 2291 cm The CN stretching band at 2252 cm -1 can be deconvoluted into two Lorentzians separated by 5 cm -1 (2254 and 2251 cm -1 ). The 2254 cm -1 band can be assigned to free acetonitrile molecules, and 2251 cm -1 band to hydrogen-bonded acetonitrile molecules. During the LC gradient the absolute and relative intensities of the two Lorentzian bands change, but their wavenumbers do not change significantly. This change in the CN stretching band shape is used here to calculate the contribution of the eluent to the final absorption spectra throughout the chromatographic runs. CN stretching (ν 2 ) combination band of both CH 3 bending (ν 3 ) and C-C stretching (ν 4 ) Water band shifting at different acetonitrile relative concentratrions. 1. REFERENCE SPECTRAL MATRIX (RSM) MEASUREMENT ABSTRACT The RSM measurement is carried out in practice by using a linear LC gradient. The interval of concentrations of the mobile phase components in the RSM will define the interval of application of the background subtraction procedure in further sample injections. On the other hand, the slope of the linear gradient defines the size of the RSM and thus the accuracy of the whole procedure. 2. CALCULATION OF A REGRESSION MODEL Effect of the number of PLS variables used in the calibration model on the noise obtained after background correction in a LC-FTIR gradient elution. CALIBRATION METHOD: Partial Least Squares SPECTRAL REGION: 2345 – 2145 cm -1 NUMBER OF SPECTRA INCLUDED IN THE CALIBRATION: 5500 (RSM) REFERENCE VALUE: Absorbance at 1639 cm -1 CONCENTRATION RANGE: Water:Acetonitrile (40:60) up to (1:99) NUMBER OF LVs: 6 RMSECV: PLS calibration spectral region PLS reference value 3. LC-FTIR MATRIX ANALYSIS USING THE PLS MODEL The PLS analysis of the LC-FTIR matrix from a sample injection provides, for every spectra included in the sample matrix, a reference value, C SAMPLE,i, the calculated absorbance at 1639 cm -1, directly related to the water concentration and so, to the mobile phase composition. 4. BACKGROUND SPECTRA CALCULATION Using the reference value previously calculated, for every spectra included in the sample matrix the position of the minimum of the absolute value of the difference between C SAMPLE,i and the absorbance at 1639 cm -1 (C REFERENCE ) of every spectra from the RSM is calculated. 5. SPECTRAL SUBTRACTION The last step of the procedure involves the direct subtraction of the calculated spectra from the original sample spectra. Minimum = p Number of the reference spectra included in the RSM |(C reference -C sample )| p p + 1 p - 1 p - 2 p + 2 Finally, the spectra to be subtracted is calculated as a linear combination of two spectra form the RSM: the corresponding to the minimum (spectra number p) and the second closest spectra which can be the spectra number p+1 or p-1. αβ C p-1 C sample CpCp αβ C p+1 C sample CpCp p-1 for C sample < C p p+1 for C sample > C p EXPERIMENTAL RESULTS FROM LC-FTIR INJECTIONS The proposed approach performs the background subtraction dynamically, according to defined spectral features of every spectrum from the sample data set so, increasing the robustness of the technique as long as possible changes in the composition of the mobile phase are automatically corrected. To estimate whether the proposed subtraction procedure provide accurate results the noise at three different solvent characteristic wavenumbers in the extracted chromatograms from a blank injection were calculated. Spectra extracted using the proposed method of eluent subtraction during the elution of a 2 mg ml -1 Caffeine standard. LC conditions: 60% acetonitrile: 40% water (1% HAc). FTIR measurement conditions: Bruker IFS 55 spectrometer equipped with a MCT detector, a Globar source and a KBr beamsplitter was employed for spectral measurements, also using a flow cell with CaF 2 windows, an optical pathlength of 25  m, 3 mm broad and a length of 32 mm. The spectra were recorded by co addition of 25 scans with a spectral resolution of 8 cm -1 at a mirror velocity of 180 kHz HeNe frequency also using an aperture of 8 mm for the IR beam. Prior to data acquisition a background spectrum of the sample compartment after removing the flow cell was acquired. LC measurement conditions: The LC system consisted in a Waters (Waters, Milford, USA) 7100 quaternary pump with a six-port injection valve (Rehodyne, Bensheim, Germany) equipped with a 12.5  l injection loop. Chromatographic separation was achieved by a C18 reversed-phase column (Nucleosil 100 RP C-18 column, 150 mm × 2.1 mm, 3  m, VDS Optilab, Berlin, Germany) using of acetonitrile and H 2 O (1% v/v acetic acid) as mobile phase components at 25ºC also using a 150  L min -1 flow-rate. The accuracy of the subtraction process was evaluated by comparing the extracted spectra of both pesticides at the peak apex to pesticide reference spectra previously measured, obtaining correlation factors of 0.94 and 0.93 for Atrazine and Diuron, respectively. On the other hand, in the following figure it is shown the extracted chromatogram at 1547 cm -1. MATLAB GUI FILE Snapshot of the Matlab GUI file developed to facilitate the use of the proposed procedure. It includes three additional univariated procedures to perform background correction in on- line LC-FTIR, also based on the use of a RSM. Results from this study show the potential use of the proposed approach to perform background correction in continuous liquid flow systems. Results obtained from the correction of the raw data from isocratic and gradient LC injections were used to verify of its capability to correct background signals in the presence of changing eluent compositions, as well as during the analyte elution. Furthermore, it is not needed complex data pre-treatment, prior knowledge, standards or reference spectra of the analytes and there is no user interaction thus increasing the repeatability of the results. Moreover, the accuracy of the whole subtraction procedure can be easily improved without any additional modifications of the method by using larger reference spectral data matrix. The use of PLS extends the applicability of the procedure to more complex systems in which the calculation of the composition can not be carried out using univariated approaches. CONCLUSIONS On-line isocratic LC-FTIR On-line gradient LC-FTIR Correlation coefficient = 0.99 Top: Extracted FTIR spectra of both pesticides at the peak apex obtained after removing the eluent contribution. Bottom: Extracted chromatogram at 1547 cm -1. Correlation coefficient = 0.93Correlation coefficient = 0.94 Wavenumber (cm -1 ) NOISE Noise values * 10 4 The measured noise levels are statistically comparable to those obtained using a constant reference background. Results obtained from the background correction of a blank gradient elution in the same range of concentrations. Raw spectral matrixSpectral matrix after background correction time (min)% Water% CH 3 CN Two pesticides, Diuron and Atrazine, were injected using the gradient indicated in the figure. BACKGROUND CORRECTION METHOD Spectra extracted using the proposed method of eluent subtraction during the elution of a 2 mg ml -1 Vanillic acid standard. LC conditions: 70% acetonitrile: 30% water (1% HAc). Previously measured vanillic acid spectra