INVASIVE HEMODYNAMIC MONITORING

Slides:



Advertisements
Similar presentations
ITU Post Operative Monitoring – Up to 4 hours
Advertisements

Sharon /Penny. 1.Review indications for the use of PA catheter with heart failure patients. 2.The difference of the four major types of PA catheters.
Use of Central Line Insertion Checklist
Hemodynamic Monitoring
SWAN GANZ CATHETERS The flow-directed balloon-tipped pulmonary artery catheter (PAC) right heart catheter.
Advanced Nursing Concepts Part 1: Hemodynamic Monitoring
Blood Transfusion Nursing Procedure. *Whole blood transfusion replenishes the circulatories:  Volume  Oxygen-carrying capacity *Packed Red Blood Cells.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
CO - RELATION WITH ECG INTRA CARDIAC PRESSURES ASHOK MADRAS MEDICAL MISSION CHENNAI
Central Line Removal Competency Assessment for Registered Professional Nurses in the Critical Care Areas References: AACN Procedure Manual for Critical.
Pulmonary Artery Catheter
5/24/ HEMODYNAMIC MONITORING. OBJECTIVE 5/24/ Describe the three attributes of circulating blood and their relationships. 2. Identify types.
HEMODYNAMIC MONITORING NUR 351/352 PROFESSOR DIANE E. WHITE RN MS CCRN PhD (c)
Swan Numbers: yes or no ? Bradley J. Phillips, M.D. Critical Care Medicine Boston Medical Center Boston University School of Medicine TRAUMA-ICU NURSING.
Pulmonary artery Balloon (swan Ganz)
CENTRAL VENOUS PRESSURE LEARNING OUTCOMES By the end of this session the student should be able to : Explain the indications for a patient requiring.
Chapter 15 Assessment of Cardiac Output
Pressure, Flow, and Resistance Understanding the relationship among pressure, flow and resistance can help you understand how cardiac output and vascular.
Hemodynamic Monitoring and Transthoracic Lines
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
MODULE F – HEMODYNAMIC MONITORING. Topics to be Covered Cardiac Output Determinants of Stroke Volume Hemodynamic Measurements Pulmonary Artery Catheterization.
Bio-Med 350 Normal Heart Function and Congestive Heart Failure.
Hemodynamic Monitoring Part I (ABP, CVP, Ao)
CENTRAL LINES AND ARTERIAL LINES
Hemodynamics Is defined as the study of the forces involved in blood circulation. Hemodynamic monitoring is used to assess cardiovascular function in the.
Cardiovascular System Assessments
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
CONCEPTS OF NORMAL HEMODYNAMICS AND SHOCK
Members of the Cardiovascular System
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Focus on Hemodynamic Monitoring and Circulatory Assist Devices
1 Arterial Lines Set Up & Monitoring Union Hospital Emergency Department.
Chapter 16 Assessment of Hemodynamic Pressures
Frank-Starling Mechanism
CHAPTER 6 DR. CARLOS ORTIZ BIO-208
 By the end of this lecture the students are expected to:  Define cardiac output, stroke volume, end- diastolic and end-systolic volumes.  Define.
The Cardiovascular System and Its Control. The Cardiovascular System: Major Functions Delivers O 2, nutrients Removes CO 2, other waste Transports hormones,
Copyright © 2008 Lippincott Williams & Wilkins. 1 Assessment of Cardiovascular Function Hemodynamic Monitoring.
Cardiac Output. Cardiac output The volume of blood pumped by either ventricle in one minute The output of the two ventricles are equal over a period of.
Cardiovascular Physiology
Copyright © 2008 Thomson Delmar Learning CHAPTER 15 Hemodynamic Measurements.
Blood and Blood Pressure. Components of Blood Plasma – Liquid portion of blood – Contains ions, proteins, hormones Cells – ___________________________________.
CENTRAL LINES AND ARTERIAL LINES
HEMODYNAMIC MONITORING: The Fundamentals
Intra-Aortic Balloon Pump What it is and what it does
Heart  Pericardium  Cardiac muscle  Chambers  Valves  Cardiac vessels  Conduction system.
CVS Monitoring in Shock
Determinants of Cardiac Output and Principles of Oxygen Delivery
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
World federation of neuroscience nurses
Arterial Blood Pressure(ABP) Arterial Blood Pressure(ABP) Central Venous Pressure(CVP) Central Venous Pressure(CVP) Pulmonary Artery Pressure(PAP) Pulmonary.
Functional Hemodynamic Monitoring NEANA Spring Meeting April 2016 Donna Adkisson, R.N., M.S.N. Clinical Educator LiDCO, Limited.
Hemodynamic Monitoring
Cardiac Cycle- 1 Mechanical events, Volume & Pressure changes in cardiac chambers & the great vessels during the cardiac cycle.
The New Educational Guidelines for Cath Lab Personnel
HEMODYNAMIC MONITORING
HEMODYNAMIC MONITORING
Pulmonary Artery Pressure Monitoring
Cardiac Output And Hemodynamic Measurements
Physiology of Circulation
Author(s): Louis D’Alecy, 2009
Objectives Describe the cardiovascular monitoring techniques used in the care of critically ill patients and how to interpret the results of hemodynamic.
Cardiac Cath NUR 422.
Cardiac Output O2 Saturation Capillary Refill
The Pulmonary Artery Catheter
Hemodynamic Monitoring
The Pulmonary Artery Catheter
INVASIVE PRESSURE MONITORING
Presentation transcript:

INVASIVE HEMODYNAMIC MONITORING Presentation by Donna Cohen, BSN, RN Heart and Vascular Center Medical University of South Carolina February 2006

INVASIVE HEMODYNAMIC MONITORING

Objectives Verbalizes purposes of Hemodynamic Monitoring Verbalize indications for Hemodynamic Monitoring Identify components of a Pulmonary Artery Catheter[Swan-Gantz] Verbalize necessary equipment needed

Objectives [con’t] Identify the correct pressure waveforms Identify the components of invasive hemodynamic monitoring[RA,PA,PAM and PCWP] Identify “normal” parameters for each component of monitoring Verbalize how to troubleshoot abnormal waveforms

Objectives [con’t] Verbalize definition of preload and afterload Verbalize what and where to document data collected Verbalize understanding of the Critical Care Hemodynamic Monitoring Policy [C1]

Introduction Swan-Ganz catheter has been in use for almost 30 years Initially developed for the management of acute myocardial infarction Now, widespread use in the management of a variety of critical illnesses and surgical procedures

Purposes of Invasive Hemodynamic Monitoring Early detection, identification, and treatment of life-threatening conditions such as heart failure and cardiac tampanade Evaluate the patient’s immediate response to treatment such as drugs and mechanical support Evaluate the effectiveness of cardiovascular function such as cardiac output and index

Indications for Hemodynamic Monitoring Any deficit or loss of cardiac function: such as AMI,CHF,Cardiomyopathy All types of shock;cardiogenic,neurogenic,or anaphylactic Decreased urine output from dehydration, hemorrhage,G.I. bleed,burns,or surgery

Components of a Pulmonary Artery Catheter

Components of Swan-Ganz [con’t] Normally has four[4] ports Proximal port – [Blue] used to measure central venous pressure/RAP and injectate port for measurement of cardiac output Distal port – [Yellow] used to measure pulmonary artery pressure Balloon port – [Red] used to determine pulmonary wedge pressure;1.5 special syringe is connected Infusion port – [White] used for fluid infusion

Components of the Monitoring System Bedside monitor – amplifier is located inside. The amplifier increases the size of signal Transducer – changes the mechanical energy or pressures of pulse into electrical energy; should be level with the phlebostatic axis[ you can estimate this by intersecting lines from the 4th ICS,mid axillary line Recorder – please record information

Phlebostatic Axis

Commonly used Terminology Preload Afterload Cardiac Output Cardiac Index Systemic Vascular Resistance [SVR] Pulmonary Vascular Resistance [PVR]

Preload Is the degree of muscle fiber stretching present in the ventricles right before systole Is the amount of blood in a ventricle before it contracts; also known as “filling pressures” Left ventricular preload is reflected by the PCWP Right ventricular preload is reflected by the CVP [RA]

Afterload Any resistance against which the ventricles must pump in order to eject its volume How hard the heart [either side left or right] has to push to get the blood out Also thought of as the “ resistance to flow” or how “clamped” the blood vessels are

Cardiac Output/Index Is the amount of blood ejected from the ventricle in one minute Two components multiply to make the cardiac output: heart rate and stroke volume [amount of blood ejected with each contraction] Cardiac index is the cardiac output adjusted for body surface area (BSI)

Computation Constant Computation constant is based on the 1) type of catheter 2) temperature (iced or room temp) of the injectate 3) the number of mL’s (5mL vs 10mL) ---we use 10 mL of room temperature injectate for our regular swanns, which requires a computation constant of 0.592

SVR / PVR Systemic Vascular Resistance – reflects left ventricular afterload Pulmonary Vascular Resistance – reflection of right ventricular afterload Many of the drugs we administer will affect Preload, Afterload, SVR/PVR, Cardiac Output

Possible Complications Increased risk of infections – same as with any central venous lines—use occlusive dressing and Biopatch to prevent Thrombosis and emboli-- air embolism may occur when the balloon ruptures, clot on end of catheter can result in pulmonary embolism Catheter wedges permanently—considered an emergency, notify MD immediately, can occur when balloon is left inflated or catheter migrates too far into pulmonary artery (flat PA waveform)…can cause pulmonary infarct after only a few minutes! Ventricular irritation – occurs when catheter migrates back into RV or is looped through the ventricle, notify MD immediately…can cause VT

Troubleshooting Dampened waveform –can occur with physical defects of the heart or catheter; can be caused by kinks, air bubbles in the system, or clots Solution: Check your line for kinks & air bubbles, aspirate (not flush) for clots, straighten out tubing or patient as much as possible No waveform – can occur with non-perfusing arrhythmias or line disconnection Solution: Check your line for disconnection, check your patient for pulse, could also be wet transducer or broken cable or box

SET-UP FOR HEMODYNAMIC Equipment Needed SET-UP FOR HEMODYNAMIC PRESSURE MONITORING 1. Obtain Barrier Kit, sterile gloves, Cordis Kit and correct swan catheter. Also need extra IV pole, transducer holder, boxes and cables. 2. Check to make sure signed consent is in chart, and that patient and/or family understand procedure. 3. Everyone in the room should be wearing a mask! 4. Position patient supine and flat if tolerated. 5. On the monitor, press “Change Screen” button, then select “Swan Ganz” to allow physician to view catheter waveforms while inserting. 6. Assist physician (s) in sterile draping and sterile setup for cordis and swan insertion.

Equipment Needed 7. Set up pressure lines and transducers [see Critical Care Skills: Clinical Handbook, Second Edition pages 293 -298] Please level pressure flush monitoring system and transducers to the phlebostastic axis. Zero the transducers. Also check to make sure all connections are secure. 8. Connect tubings to patient [PA port and CVP port] when physician is ready to flush the swann. Flush all ports of swann before inserting. 9. While floating the swann, observe for ventricular ectopy on the monitor, and make physician aware of frequent PVC’s or runs of VT ! 10. After swann is in place, assist with cleanup and let patient know procedure is complete.

Equipment Needed 11. Obtain your RA [CVP], PAS/D, PAM, and wedge. For Cardiac Outputs, inject 10 mLs of D5W after pushing the start button, repeat X 3. Delete outputs not within 1 point of the mean value. Can use .9NS instead, but affects the accuracy of the output reading. 12. Before obtaining the cardiac output, please check the computation constant [should read 0.692 for regular yellow swans; 0.692 for SVO2 or blue swanns] 13. Perform hemocalculations (enter today’s height and weight). 14. Document findings on the ICU flowsheet.

PA Insertion Waves

Central Venous Pressure (CVP) Zero transducer to the patient’s phlebostatic axis Always read CVP at end expiration CVP is a direct measurement of right ventricular end diastolic pressure

Right Ventricular Waveform If the swan falls or gets pulled back into the RV it is considered a swan emergency. If you see an RV waveform (looks like VT) pull the swan immediately. If the swan remains in the RV it may cause the patient to go into VT.

Pulmonary Capillary Wedge Pressure (PCWP) Zero the transducer to the patient’s phlebostatic axis. Measure the PCWP at end expiration PCWP should not be higher than PA diastolic PCWP is an indirect measurement of left ventricular end diastolic pressure.

Cardiac Output It is the amount of blood pumped by the heart in one minute. Calculated by multiplying heart rate times stroke volume. Cardiac Index is the cardiac output adjusted for body surface area.

How to read a PA waveform Measured at end expiration! Dicrotic notch (closure of PulmonicValve) should always be on Right side of wave (if notch on Left side find out if the tip in the RV) Measure PAS at the top of the wave upslope (at end of QRS); PAD is measured at the trough preceding the systolic peak (be careful not to measure whip in the wave) How to read a PCWP (aka wedge) After balloon is inflated, compare waveform to respiratory waveform to determine measurement at the end of expiration (last clear wave before patient inspires) Tip: if waveform is difficult to read, try resting hand on pt’s chest as you wedge; determine where the end of expiration occurs on the wedge waveform, then measure across several waves for consistency

Documentation Document PAS, PAD, and PCWP on nursing flowsheet under Hemodynamic Parameters PCWP will rarely be > PAD (if so, means blood is flowing backwards) If PCWP = PAD, look for tamponade Under circumstances where the catheter will not wedge (or should not be), do not document any values in the PCWP column on the flowsheet If you use the PAD measurement for calculations, it is acceptable to write ONLY “PAD value used for calculations” at the top of your numbers