UNICAMP THE HEIGHT OF LIQUID METHOD FOR FREE SURFACE FLOWS Flow simulations of real processes often involve fluids that are separated by a sharp interface.

Slides:



Advertisements
Similar presentations
Fluid Mechanics Research Group Two phase modelling for industrial applications Prof A.E.Holdø & R.K.Calay.
Advertisements

MASS TRANSFER TO SPHERE AND HEMISPHERE ELCTRODES BY IMPINGING JET
Phoenics User Conference on CFD May 2004 Vipac Engineers & Scientists Ltd COMPUTATIONAL FLUID DYNAMICS Simulation of Turbulent Flows and Pollutant Dispersion.
SolidWorks Flow Simulation
Fluent Overview Ahmadi/Nazridoust ME 437/537/637.
MULTLAB FEM-UNICAMP UNICAMP SETTING SOURCES & BOUNDARY CONDITIONS USING VR Section 7 of TR326 describes Sources and B.C. 5n the form of object and its.
UNICAMP GENERAL PARTICLE TRACKING ALGORITHM Sources of Information : Phoenics Lecture: GENTRAGENTRA Workshop: GENTRAGENTRA GENTRA user guide: (html) or.
Integration Relation for Control Volume
MULTLAB FEM-UNICAMP UNICAMP EVALUATING RESIDUALS AND IMBALANCE FORCES BY INFORM Residuals These are imbalances (errors) in the finite-volume equations.
Chapter 4 Mass and Energy Analysis of Control Volumes (Open Systems)
MULTLAB FEM-UNICAMP UNICAMP LID DRIVEN CAVITY FLOW The lid-driven cavity problem has long been used a test or validation case for new codes or new solution.
University of Western Ontario
Design Constraints for Liquid-Protected Divertors S. Shin, S. I. Abdel-Khalik, M. Yoda and ARIES Team G. W. Woodruff School of Mechanical Engineering Atlanta,
HARP REU Program 2012 Susan T. Brown, Ph.D. ND Numbers in CFD and Setting up a Problem.
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
Computer Aided Thermal Fluid Analysis Lecture 7 Dr. Ming-Jyh Chern ME NTUST.
Homework 3: Use the Fixed Grid --Volume of Fluid Method with Structured Cartesian CVFEM mesh To track Filling Front h=1 h = 0 2 r = 1 3 Hand in 1. Code.
Fluid Kinematics Fluid Dynamics . Fluid Flow Concepts and Reynolds Transport Theorem ä Descriptions of: ä fluid motion ä fluid flows ä temporal and spatial.
Preliminary Assessment of Porous Gas-Cooled and Thin- Liquid-Protected Divertors S. I. Abdel-Khalik, S. Shin, and M. Yoda ARIES Meeting, UCSD (March 2004)
University of South Carolina FCR Laboratory Dept. of Chemical Engineering By W. K. Lee, S. Shimpalee, J. Glandt and J. W. Van Zee Fuel Cell Research Laboratory.
Single and multi-phase flows through rock fractures occur in various situations, such as transport of dissolved contaminants through geological strata,
Temperature Gradient Limits for Liquid-Protected Divertors S. I. Abdel-Khalik, S. Shin, and M. Yoda ARIES Meeting (June 2004) G. W. Woodruff School of.
Fluid mechanics 3.1 – key points
A TWO-FLUID NUMERICAL MODEL OF THE LIMPET OWC CG Mingham, L Qian, DM Causon and DM Ingram Centre for Mathematical Modelling and Flow Analysis Manchester.
Module 3 Fluid Flow. Lesson 20 CONTINUITY EQUATION DESCRIBE how the density of a fluid varies with temperature. DEFINE the term buoyancy. DESCRIBE the.
Gyeongsang National University Hanshik Chung. CONTENTS  Background of Study  Introduction & Objective  Results and discussion  Conclusions.
Chapter 14 PHYSICS 2048C Fluids. What Is a Fluid?  A fluid, in contrast to a solid, is a substance that can flow.  Fluids conform to the boundaries.
1 CREL meeting 2004 CFD Simulation of Fisher-Tropsch Synthesis in Slurry Bubble Column By Andrey Troshko Prepared by Peter Spicka Fluent Inc. 10 Cavendish.
Simulation of Droplet Drawback in Inkjet Printing
The First Law of Thermodynamics
Warm-up Pick up the free response at the door and begin working on it.
A Hybrid Particle-Mesh Method for Viscous, Incompressible, Multiphase Flows Jie LIU, Seiichi KOSHIZUKA Yoshiaki OKA The University of Tokyo,
Sharp Interface Tracking in Rotating Microflows of Solvent Extraction Hyunkyung Lim, Valmor de Almeida, and James Glimm OAK RIDGE NATIONAL LABORATORY &
PTT 204/3 APPLIED FLUID MECHANICS SEM 2 (2012/2013)
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
Bernoulli’s Principle. Usually, liquids are considered “incompressible”, meaning that the density of the liquid remains nearly constant. Gases are easily.
MULTLAB FEM-UNICAMP UNICAMP SETTING SOURCES & BOUNDARY CONDITIONS USING VR Section 7 of TR326 describes Sources and B.C. 5n the form of object and its.
A particle-gridless hybrid methods for incompressible flows
© 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
Monday, November 9, 1998 Chapter 9: Archimedes’ principle compressibility bulk modulus fluids & Bernoulli’s equation.
Chapter 14 Fluids What is a Fluid? A fluid, in contrast to a solid, is a substance that can flow. Fluids conform to the boundaries of any container.
Reynolds Transport Theorem We need to relate time derivative of a property of a system to rate of change of that property within a certain region (C.V.)
J.-Ph. Braeunig CEA DAM Ile-de-FrancePage 1 Jean-Philippe Braeunig CEA DAM Île-de-France, Bruyères-le-Châtel, LRC CEA-ENS Cachan
Fluid Dynamics AP Physics B.
CFX-10 Introduction Lecture 1.
WS7-1 ANSYS, Inc. Proprietary © 2009 ANSYS, Inc. All rights reserved. April 28, 2009 Inventory # Introductory FLUENT Training Workshop 7 Tank Flushing.
Chapter 14 Fluids.
Governing Equations Conservation of Mass Conservation of Momentum Velocity Stress tensor Force Pressure Surface normal Computation Flowsheet Grid values.
Lecture Objectives -Finish Particle dynamics modeling -See some examples of particle tracking -Eulerian Modeling -Define deposition velocity -Fluid Dynamics.
Some slides on UCLA LM-MHD capabilities and Preliminary Incompressible LM Jet Simulations in Muon Collider Fields Neil Morley and Manmeet Narula Fusion.
Differential Analysis of Fluid Flow. Navier-Stokes equations Example: incompressible Navier-Stokes equations.
MULTLAB FEM-UNICAMP UNICAMP Workshop on Thermal Boundary Conditions Several thermal boundary conditions will be explored in this workshop modifying the.
OEAS 604: Introduction to Physical Oceanography Conservation of Mass Chapter 4 – Knauss Chapter 5 – Talley et al. 1.
Lecture Objectives: - Numerics. Finite Volume Method - Conservation of  for the finite volume w e w e l h n s P E W xx xx xx - Finite volume.
CSE 872 Dr. Charles B. Owen Advanced Computer Graphics1 Water Computational Fluid Dynamics Volumes Lagrangian vs. Eulerian modelling Navier-Stokes equations.
CFD Exercise 1 Laminar & turbulent flows with COMSOL.
TransAT Tutorial Backward Step May 2015 ASCOMP
1 Chapter 5 Mass and Energy Analysis of Control Volumes.
Workshop 7 Tank Flushing
Workshop 7 Tank Flushing
CE 3305 Engineering FLUID MECHANICS
Simulation of Pipe Flow Using FlowLab 1.1 (PreLab 1)
A TWO-FLUID NUMERICAL MODEL OF THE LIMPET OWC
Workshop 5 Cavitating Centrifugal Pump
Workshop 5 Centrifugal Pump
Fluent Overview Ahmadi/Nazridoust ME 437/537/637.
3.2 Pressure and the Buoyant Force
Lecture no 13 &14 Kinetics & kinematics of fluid flow
Fluid Kinematics Fluid Dynamics.
II. Theory for numerical analysis of multi-phase flow (Practice)
Presentation transcript:

UNICAMP THE HEIGHT OF LIQUID METHOD FOR FREE SURFACE FLOWS Flow simulations of real processes often involve fluids that are separated by a sharp interface. Mould filling, film coating, wave formation, liquid sloshing in tanks are some examples. The method, called Height-Of-Liquid (HOL), calculates the height of the interface at each point by focusing on one of the fluids (say the lower one) and computing the height of the liquid column through a mass balance over the sides of the column. Details of how to activate HOL are provided in the HOL-method lecture which appears in the multi-phase section of the general lectures on PHOENICS – see link HOL.HOL

UNICAMP APPLICABILITY AND RESTRICTIONS The HOL method is applicable to: –Incompressible flows; –Steady and unsteady flows; –Two- or three-dimensional flows; –Cartesian, polar or curvilinear coordinates. The only restriction is that the flow considered should exhibit no "overturning" of the interface. This means that there must exist one direction, designated the "up" direction, along which only ONE intersection of the interface exists.

UNICAMP INTERFACE & OTHER DEFINITIONS Interface – defines the boundary between two immiscible fluids (gas- liquid) or (liquid-liquid) Representation of the numerical grid superposed to the interface. The domain is composed by vertical slices, aligned with g, each one displaying a column of heavier liquid.

UNICAMP INTERFACE DISPLACEMENT ON A SLICE OF CELLS The interface position is determined by a volumetric balance applied to vertical cell columns (incompressible & no overturning). The volume imbalance at the cell where the interface lays will displace it upward or downward.

UNICAMP FRACTION OF LIQUID ‘VOF’ VOF is the volumetric fraction of the cell occupied by the heavier fluid. VOF =1 heavier fluid; VOF = 0 lighter fluid and 0<VOF<1 interface. In a column of cells just one cell will have 0<VOF<1.

UNICAMP TIME STEP AND CELL DIMENSIONS Tracking the interface requires a transient simulation. The time step and the cell size must be balanced such that the interface stays at least one (usually five or more) time steps to leave one cell. If the time step and the cells sizes are not balanced it may happen that in a single time step the interface may travel more than one cell while in the neighboring slices it doesn’t happen. The balance of time step and cell size is defined case by case. It is done by estimating the maximum velocity, choosing on cell size accordingly to the spatial resolution required and fixing a time step at least five times less than the ratio between the cell size and the maximum velocity.

UNICAMP WORKSHOP HOL #1 GEOMETRY –DOMAIN SIZE (X,Y,Z) = (0.1, 0.5, 1) –GRID SIZE: AUTO –TRANSIENT: TIME = 25S & TIME STEPS = 50 MODELS –VELOCITY: LAMINAR – FREE SURFACE MODEL: HOL; HEIGHT DIRECTION: +Z

UNICAMP WORKSHOP HOL #1 PROPERTIES LIGHT FLUID: AIR (0) HEAVY FLUID: WATER (67) DOMAIN INITIALLY FULLY: LIGHT FLUID OBJECTS INLET: SIZE (0.1, 0.1, 0) PLACE (0,0,0) W = +0.1M/S INLET DENSITY: HEAVY OUTLET: SIZE (0.1, 0.5, 0) PLACE (0,0,1) INITIALIZATION –V1 = 0; W1 = 0.1; VOF = 0

UNICAMP WORKSHOP HOL #1 SOURCES NUMERICS –NUMBER OF ITERACTIONS: 10 –RELAX: AUTO OFF –RELAX: FALSDT 1E-03 FOR V1, W1 OUTPUTS FIELD DUMPING

UNICAMP WORKSHOP HOL #1 Get the VOF instantaneous contour maps. Where is the interface 

UNICAMP INTERFACE LOCATION The interface position is not known precisely, what is known is the fraction of volume in each cell. Notice that the interface is where 0 < VOF < 1, see not-averaged contour plot. One possibility is to admit that the free interface coincides with the points where VOF = 0.5.

UNICAMP SOLUTION REFINEMENT Is the VOF, velocities and pressure fields fully converged  Set time steps to 150; change the dumping fields frequency to 12 and compare the solution with the previous run. Answer if the liquid sloshing observed on the previous run still exists  Also observe the velocity vector fields.

UNICAMP SLUMPING OF A LIQUID COLUMN BY HOL Load library case P102 Set the view to –X and up direction to +Z Change the number of iterations to 100. Inspect the blockages, and all other objects. Run the case

UNICAMP END

UNICAMP INTERFACE & OTHER DEFINITIONS Interface – defines the boundary between two immiscible fluids (gas- liquid) or (liquid-liquid) Representation of the numerical grid superposed to the interface. The domain is composed by vertical slices, aligned with g, each one displaying a column of heavier liquid. HEAVIER FLUID LIGHTER FLUID

UNICAMP INTERFACE DISPLACEMENT ON A SLICE OF CELLS The interface position is determined by a volumetric balance applied to vertical cell columns (incompressible & no overturning). The volume imbalance at the cell where the interface lays will displace it upward or downward. To conserve the volume the interface has to displaced upward

UNICAMP FRACTION OF LIQUID ‘VOF’ VOF is the volumetric fraction of the cell occupied by the heavier fluid. VOF =1 heavier fluid; VOF = 0 lighter fluid and 0<VOF<1 interface. In a column of cells just one cell will have 0<VOF<1. VOF = 0 VOF = 1 VOF = 0.6 VOF = 0 VOF = 0.5 VOF = 1

UNICAMP WORKSHOP HOL #1 2s 4s 6s 8s 10s Get the VOF instantaneous contour maps. Where is the interface 

UNICAMP INTERFACE LOCATION The interface position is not known precisely, what is known is the fraction of volume in each cell. Notice that the interface is where 0 < VOF < 1, see not-averaged contour plot. One possibility is to admit that the free interface coincides with the points where VOF = 0.5.