Continuous Glucose Monitoring. Diabetes Management Evolution Insulin Delivery Glucose Monitoring 2000 First CGM system 2006 Paradigm REAL- Time, combining.

Slides:



Advertisements
Similar presentations
Hypoglycemia Prevention & Treatment
Advertisements

Managing Sick Days and Hospital Stays Mike Heile MD Orlando, CWD July, 2011.
Making The Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE
Making The Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE
Do you require any assistance? Do you experience any symptoms? Calit2 Summer Research Program Minimize Hypoglycemic Episodes Utilizing Remote Assistance.
Advanced Pumping. Objectives: Identify situations to utilize temporary basal rate in pump therapy patients. Identify examples of when to use combination.
1-800-DIABETES DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to Know DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to.
Diabetes Care Tasks at School: What Key Personnel Need to Know Diabetes Care Tasks at School: What Key Personnel Need to Know INSULIN ADMINISTRATION.
Monitoring Diabetes.
INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS
1-800-DIABETES DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to Know DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to.
Quick Pump Facts o Constantly provides insulin o Pager-sized “mini-computer” worn outside the body o Pump itself is attached to your body by a small cannula.
WHAT’S NEW IN DIABETES Lisa Still, RN,CDE Diabetes Specialty Nurse Arkansas Children’s Hospital November 2011.
Insulin Pump What to tell your patient!! Prakash Abraham Isla Fairley.
Continuous Glucose Monitoring
Putting Pump Policies Into Practice- Case Study Conference Call Elizabeth Blair, ANP-BC,CDE Joyce Lekarcyk, RN, CDE.
Top-10 Techniques for Attaining Glucose Goals Gary Scheiner MS, CDE Owner/Director Integrated Diabetes Services Wynnewood, PA
1 INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS H. Peter Chase, MD Vicky Gage, RN, CDE Laurel Messer, RN, CDE Susie Owen, RN, CDE Sally Sullivan, RN, CDE.
Helping Belton ISD Students Succeed What Every BISD Staff Needs to Know About: Helping Belton ISD Students Succeed What Every BISD Staff Needs to Know.
Clinical Protocol Using Insulin Pump Easy Guideline for Initiating Insulin Pumps on Type 2 Diabetes Patients.
1 Progress Towards an Artificial Pancreas for T1D WILLIAM TAMBORLANE, MD Chief of Pediatric Endocrinology, Yale University, Deputy Director, Yale Center.
Accuracy of the FreeStyle Navigator ™ Continuous Glucose Monitor Diabetes Research in Children Network Larry Fox, 1 Roy Beck, 2 Stuart Weinzimer, 3 Katrina.
Management Tools and CGM Kathryn Moe, RN CDE Medtronic Diabetes.
Pumps and Sensors In the School Setting. 2 Agenda Comparison of available insulin pumps Continuous glucose monitors Pump therapy & CGM in the school setting.
INSULIN THERAPY IN TYPE 1 DIABETES
Are You A Candidate For An Insulin Pump?
Practical Aspects of Continuous Glucose Monitoring 2008 Rosanna Fiallo-Scharer, MD Laurel Messer, RN, BSN, CDE Barbara Davis Center for Childhood Diabetes.
Diabetes Technology Update
Mealtime Glycemic Excursions in Pediatric Subjects with Type 1 Diabetes: Results of the Diabetes Research in Children (DirecNet) Accuracy Study Study Group.
Closed-Loop Insulin Delivery in Children
Titrating Insulin to Glycemic Target Judy Bowen, MD CIM Rotation September, 2006.
OnsetPeakDuration Rapid Acting Lispro (Humalog) min3-5 hours Aspart (Novolog)15-30 min1-3 hours3-5 hours Intermediate Acting NPH1-4 hours5-10.
Background: DirecNet Diabetes Research in Children Network NIH funded collaborative study group 5 clinical centers, central laboratory, coordinating center,
Making the Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE Owner & Clinical Director Integrated Diabetes Services LLC Wynnewood, PA AADE 2014.
Diabetes Research in Children Network Pilot Study of the Navigator TM Continuous Glucose Monitoring System in Children with Type 1 Diabetes: Safety, Tolerability,
Use of The FreeStyle Navigator TM Continuous Glucose Monitoring System in Children on Glargine- based Multiple Daily Injection Therapy Stuart Weinzimer.
Continuous Glucose Monitors
Accuracy Study of the Medtronic Minimed Continuous Glucose Monitoring System (CGMS) and GlucoWatch® G2TM Biographer (GW2B) in Children with Type 1 Diabetes.
Type I Diabetes Mellitus
INSULIN PUMPS Shelby Polk DNP, FNP-BC, CDE. 2 MANAGEMENT OF DIABETES IN SCHOOLS Exercise Legal Rights Health & Learning Nutrition Insulin Administration.
Hypoglycemia Hypoglycemia Prevention & Treatment By RichardNabhan Richard Nabhan Consultant Physician Cardiologist & Diabetologist Dar Al-Shifaa Hospital.
Clarification of Pump Orders from Barbara Davis Center Diabetes Resource Nurse Winter/Spring 2013.
DirecNet Study of the Accuracy of the Navigator Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes Darrell Wilson 1,
The Super Bolus And The Projected BG Alert New Insulin Pump Ideas To Improve Glucose Levels, Avoid Hypoglycemia And Speed Correction Of Hyperglycemia John.
Insulin Pump Therapy Bruce W. Bode, MD and Sandra Weber, MD.
January 2013 Standards of Care for Diabetes Management in the School Setting – Colorado January 2013.
Special Situations In The Management Of In-Patient Hyperglycemia
Monitoring and Management Jennifer Danielson, PharmD, MBA, CDE Clinical Assistant Professor University of Washington School of Pharmacy.
Dr Zaranyika MBChB(Hons) UZ, MPH, FCP SA Department of Medicine UZ-CHS
 History of advancement in diabetes treatment  New technology  Features  Pros and Cons  Safety in school  Questions.
Monitoring and Management
The Dexcom G4 PLATINUM Continuous Glucose Monitoring System is designed with convenience, performance, and simplicity in mind. You are already using the.
Copyright © 2006 American Medical Association. All rights reserved.
Making the Most of Continuous Glucose Monitoring
Diabetes Devices Workshop
1-800-DIABETES DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to Know DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to.
Consultant/ Clinical Senior Lecturer
Living with Diabetes Presentation Overview: Diagnosis
Today we are going to cover….
Battery life of transmitter is a minimum of 6 months.
Diabetes Education.
Diabetes Care Tasks at School: What Key Personnel Need To Know
Components of a CGM record over a 3
LBL Rev 01.
Today we are going to cover….
Continuous Subcutaneous Insulin Infusion (CSII) [Insulin Pump]
Pharmacist Involvement in Continuous Glucose Monitoring
Introduction to Continuous Glucose Monitoring
Insulin in Type 2 Diabetes
Practical Implementation and Optimization of A Closed Loop System
Presentation transcript:

Continuous Glucose Monitoring

Diabetes Management Evolution Insulin Delivery Glucose Monitoring 2000 First CGM system 2006 Paradigm REAL- Time, combining Insulin Pump and CGM 1983 First Minimed Pump First Insulin Pump 1920s Insulin Injections Real-time CGM Urine Testing 1977 Blood Glucose Meter 1999 First Animas Pump-R Dexcom G4 Navigator NOTE: Only the Medtronic Real-time CGM is approved for use in children and adolescents in the U.S.

Why Continuous Glucose Monitor? Prevention of hypoglycemia Prevention of hyperglycemia Pattern assessment Basal Testing Assess the impact of food on blood glucose Assess the impact of exercise on blood glucose Behavior modification tool Alerts/Alarms: Safety, peace of mind…

Hypoglycemia in Children and Adolescents 657 children followed for 3 years 8.5% had severe (seizure/coma) hypoglycemia 27% had moderate (required assistance) hypoglycemia 75% of seizures occurred at night Recent CGM data shows seizure may require prolonged severe hypoglycemia prior to event Davis EA, et al. “Hypoglycemia: Incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM” Diabetes Care 1997;20:22-25.

17 y.o. Female, A1C 6.2%, in Study 3 Months

17 y.o. Female, A1C 6.2% Seizure

14 y.o. male A1C 6.6%, Crews (rowing team) in PM 5/16/06 5/27/06

Camp Study: Duration of hypoglycemia with and without remote monitoring in 13 y.o. male on MDI “Insulin Rx” is glucagon No Remote Monitoring <70 mg/dl = 350 minutes <50 mg/dl = 305 minutes Remote Monitoring <70 mg/dl = 110 minutes < 50 mg/dl = 10 minutes

Fingerstick Measurement Glucose (mg/dl) Breakfast 8:30 am Lunch 12:00 noon Dinner 6:00 p.m. Bedtime 10:30 p.m. Insulin Bolus Target Range Daily Patient Log

Target Range Daily Patient Log and Sensor Data Glucose (mg/dl) Breakfast 8:30 a.m. Lunch 12:00 noon Dinner 6:00 p.m. Bedtime 10:30 p.m. Sensor Measurement Insulin Bolus Fingerstick Measurement

What’s the Difference?? mg/dL OR mg/dL dropping at rate of >2 mg/dL/min CGM adds an additional dimension, the rate of change and direction of change.

Practical Application: Real Life Experience “Paula’s Pearls”

Pearl # 1: Match Device to Patient Needs Size…real estate issues Transmitter Range

Transmitter Range: I can’t find you!!

Pearl # 2 : Match Insertion Approach…Ouch! ◊ Use numbing cream: lidocaine topical Ela-Max cream EMLA cream ◊ Use soap and water to wipe off cream then clean with alcohol

Tape Issues: How do we get this thing to stay on?? IV 3000, Tegaderm, Hy-Tape Coban IV prep- avoid at sensor insertion area “Sandwich”/layer tape Tape Allergies…Ugh!

Pearl # 3: Teach, Teach and Teach Again! Sensor Lag Time Calibration Trend Arrows Glucose Trends/Patterns

Sensor Lag Time: Why doesn’t the sensor match my fingerstick reading? There is a minute lag time between interstitial fluid (ISF) glucose and BG Lag occurs with ALL subcutaneous sensors CGM is a trending device, NOT a treatment device

Sensor Lag Fingerstick Capillary Glucose (SMBG) Interstitial Fluid Glucose (CGM)

QUESTION: When will the ISF glucose and the BG value be the most similar/closest? When BG is stable/not fluctuating rapidly

QUESTION: When using a CGM, when should the patient test their BG with a fingerstick? 1.Before all treatment decisions and insulin 2.To verify symptoms of hypoglycemia 3.Before driving

Calibration: When to calibrate? The accuracy of all the CGM’s are dependent on the calibration phase Devices calibrate in 1-2 hours Must do a fingerstick BG to calibrate Do NOT calibrate when the BG is changing rapidly

Calibration: When is the best time to calibrate? When BG is not changing rapidly

Trend Arrows: Show the direction of change Provides information on the rate-of-change

Activity Table teams review the CGM downloads What do you see? What don’t you see? Recommendations/Suggestions?

Glucose Trends – CGM Report Post-breakfast excursion

Post-breakfast excursion Nocturnal lows Glucose Trends – CGM Report

Pearl # 4: Respond to Data 1.Change behavior! Pre-bolus Less carbs at breakfast Assess food impact 2.Check basal rates 3.Use alarms

Pearl # 5: Who should wear a CGM? MOTIVATED patients/parents! Those willing and able to be educated on the device Those who are willing to look at and respond to the data! Those with realistic expectations and who can handle a potentially “rocky” start

CGM REPORTS

Report #1: Patience is important!

Report # 2: Missed Meal Bolus

Report # 3: Near perfection! A1C 6.1%

Report # 4: Failure to acknowledge alarms and using pump suspend

Report # 5: Pump site failure Pump site failureInsulin via syringe

“NAKED DIABETES!”