Pneumatics technology 4. lesson

Slides:



Advertisements
Similar presentations
Pneumatic Cylinders Chapter 3.
Advertisements

Pneumatic Valves Lesson 4.
Unit Seven: Pumps and Compressors
Module 3 Practical Tasks
Unit Eight Check Valves, Cylinders, and Motors
For power, motion and control
Fluid Power Hydraulic Cylinders
Cylinders and Actuators
HYDRAULICS & PNEUMATICS
For system diagrams and component identification
Basic Pneumatic Circuitry
Pneumatics Pneumatik By Clifford Mayhew St Helens College
HYDRAULICS & PNEUMATICS
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
Module 6 : Flow control valves
Ms 4.20 pneumatic cylinders/Tieh SF1 Pneumatic Cylinders.
Simple Pressure Control Valves
Development of single actuator circuits
Exercise 1 Feeding Workpieces from a Gravity Feed Magazine New Components: 3/2-Way Valve Single Acting Cylinder Service Unit.
For precision and control
Pneumatics technology 5. lesson
HYDRAULICS & PNEUMATICS
Pneumatics.
Control System Components Topic: Actuators and Valve Positioner
Actuators.
Pneumatic Logic Sensors and Actuators
HYDRAULICS & PNEUMATICS
Lesson 5 Fluid Systems.
Basic Principles of Hydraulics
Pneumatics.
Standard Grade Technological Studies
Actuators. Pneumatic Power Cylinders As compressed air moves into the cylinder, it pushes the piston along the length of the cylinder. Compressed air.
Pneumatic and hydraulic actuation system (cont.)
HL Sample Question Applied Control Systems Underlying Principles.
HYDRAULICS & PNEUMATICS
Air Cylinders Convert the energy contained in the compressed air
Fluid Power Control.
Fluid Power Control.
Automatic Transmission Components and Operation
H & P Formulas Engineering II – August The parts and values of concern…. D 1 = diameter of cylinder (in) D 2 = diameter of piston rod (in) P 1 =
Basic Pneumatic Circuitry For control and automation.
Linear actuator Cylinders Single acting Double acting
Automatic Transmissions and Transaxles
Unit III Class II Pneumatic actuators.
Double Acting Cylinder
Engineering II – August 2016
Chapter 6: Hydraulic Cylinders and Cylinder Cushioning
PNEUMATIC CIRCUITS.
HYDRAULIC & PNEUMATIC CIRCUITS
HYDRAULICS & PNEUMATICS
Directional control valves
HYDRAULICS & PNEUMATICS
Cylinder Cushioning mechanism
Pneumatics Module 9 Time delay valve.
Logic Functions Pneumatics Module 7.
Actuators and output devices
Basic principles of hydraulic symbols
Actuators and directional control valves
SHAPER MACHINE SHAPER MACHINE SHAPER MACHINE.
Actuators & Directional Control Valves
Industrial Electronics
Applied Control Systems Underlying Principles
The CASCADE Method similar to that for electromechanical devices.
Module – 4: Single Acting Cylinder
Actuators & Directional Control Valves
Hydraulic Component: Actuator
Miscellaneous pneumatic topics
Introduction to Electro-pneumatic
Fluid Power System Electrical Control
Hydraulic Cylinders • Hydraulic Motors
Presentation transcript:

Pneumatics technology 4. lesson Institute of Engeneering Sciences Pneumatics technology 4. lesson

About the forth course Aaaaaa Aaaaaaa

2/2 Valve actuator control - A pair of the most basic of all valve types the 2/2 can be used to control a single acting cylinder The normally closed position of the valve is produced by the spring The operated position is produced by the push button - One valve admits air the other valve exhausts it 2 10 12 1 OUT IN 2/2 Valve actuator control - A pair of the most basic of all valve types the 2/2 can be used to control a single acting cylinder - The normally closed position of the valve is produced by the spring - The operated position is produced by the push button - One valve admits air the other valve exhausts it

2/2 Valve actuator control - The button marked OUT is pushed to operate the valve Air is connected to the cylinder and it outstrokes Air cannot escape to atmosphere through the valve marked IN as this is closed The air at atmospheric pressure in the front of the cylinder vents through the breather port 2 10 1 12 OUT IN 2/2 Valve actuator control - The button marked OUT is pushed to operate the valve Air is connected to the cylinder and it outstrokes Air cannot escape to atmosphere through the valve marked IN as this is closed The air at atmospheric pressure in the front of the cylinder vents through the breather port

2/2 Valve actuator control The push button of the valve marked OUT is released and it returns to a normal closed position Air is now trapped in the system and provided there are no leaks the piston rod will stay in the outstroked position If the load increases beyond the force exerted by the air the piston rod will start to move in 2 10 1 12 OUT IN 2/2 Valve actuator control The push button of the valve marked OUT is released and it returns to a normal closed position Air is now trapped in the system and provided there are no leaks the piston rod will stay in the outstroked position If the load increases beyond the force exerted by the air the piston rod will start to move in

2/2 Valve actuator control The button marked IN is pushed to operate the valve Air escapes and the piston rod moves to the instroked position The push button must be held operated until the piston rod is fully in Atmospheric air will be drawn in to the front of the cylinder through the vent port 2/2 Valve actuator control The button marked IN is pushed to operate the valve Air escapes and the piston rod moves to the instroked position The push button must be held operated until the piston rod is fully in Atmospheric air will be drawn in to the front of the cylinder through the vent port 2 1 12 10 12 10 1 2 OUT IN

2/2 Valve actuator control - If the button marked IN is released the piston rod will remain in the instroked position - Any leaks in the installation can cause the piston rod to creep 2 10 12 1 OUT IN 2/2 Valve actuator control - If the button marked IN is released the piston rod will remain in the instroked position - Any leaks in the installation can cause the piston rod to creep

Direct Control of a Single-acting cylinder A 3 port valve provides the inlet and exhaust path and is the normal choice for the control of a single acting cylinder In the normal position produced by the spring, the valve is closed In the operated position produced by the push button the valve is open The push button must be held down for as long as the cylinder is outstroked 1 2 3 12 10 Direct Control of a Single-acting cylinder A 3 port valve provides the inlet and exhaust path and is the normal choice for the control of a single acting cylinder In the normal position produced by the spring, the valve is closed In the operated position produced by the push button the valve is open The push button must be held down for as long as the cylinder is outstroked The piston of a single-acting cylinder is to move out when a pushbutton is operated, on relasing pushbutton, the cylinder is to travel back to the end position. When the 3/2-way valve is operated, air flows from P to A and exhaust port R is blocked. When the bushbutton is released, the valve is reset by the spring. The cylinder chamber and the compressed air line exhaust from A to R, and the compressed air port P is closed.

Direct Control of a Single-acting cylinder A 3 port valve provides the inlet and exhaust path and is the normal choice for the control of a single acting cylinder In the normal position produced by the spring, the valve is closed In the operated position produced by the push button the valve is open The push button must be held down for as long as the cylinder is outstroked 3/2 valve actuator control A 3 port valve provides the inlet and exhaust path and is the normal choice for the control of a single acting cylinder In the normal position produced by the spring, the valve is closed In the operated position produced by the push button the valve is open The push button must be held down for as long as the cylinder is outstroked 2 12 10 3 1

Indirect Control of a Single-acting cylinder The piston of a large-volume single-acting cylinder (large diameter, large stroke lenght, large distance from valve to cylinder) is to move out after operating a valve and return to its end position after this valve has been released. Operation of valve 1.2 opens the passage for the compressed air from P to A, and hence signal at Z on valve 1.1. Owing to switchover of vave 1.1, air flows from P to A and thus the forward stroke is effected on the single-acting cylinder. 1 2 3 12 10 1 2 3 12 10 Indirect Control of a Single-acting cylinder The piston of a large-volume single-acting cylinder (large diameter, large stroke lenght, large distance from valve to cylinder) is to move out after operating a valve and return to its end position after this valve has been released. Operation of valve 1.2 opens the passage for the compressed air from P to A, and hence signal at Z on valve 1.1. Owing to switchover of vave 1.1, air flows from P to A and thus the forward stroke is effected on the single-acting cylinder. 1.1 1.1 1.2 1.2 Push

Double acting cylinder They are available in different constructions such as: Conventional Double ended piston rod type Rod less type Tandem type Multi-position type Rotary type Double acting cylinder They are available in different constructions such as: Conventional Double ended piston rod type Rod less type Tandem type Multi-position type Rotary type

Conventional cylinders Duble acting cylinders are equipped with two working ports – one on the piston side and the other on the rod side. To achieve forward motion of the cylinder, compressed air is admitted on the piston side and the rod side is connected to exhaust. During return motion supply air admitted at the rod side while the piston side volume is connected to the exthaust. Force is exerted by the piston both during forward and return motion of cylinder. Duble acting cylinders are available in diameters from few mm to around 300 mm and stroke lengths of few mm up to 2 meters. Conventional cylinders Duble acting cylinders are equipped with two working ports – one on the piston side and the other on the rod side. To achieve forward motion of the cylinder, compressed air is admitted on the piston side and the rod side is connected to exhaust. During return motion supply air admitted at the rod side while the piston side volume is connected to the exthaust. Force is exerted by the piston both during forward and return motion of cylinder. Duble acting cylinders are available in diameters from few mm to around 300 mm and stroke lengths of few mm up to 2 meters.

Double ended piston rod type Pneumatic cylinders operates at much higher speeds than hydraulic cylinder. Due to this, there is a tendency of the piston to ram against the end covers as the piston approaches the ends at high velocity especially in cylinder with large mass. This impact force can damage the cylinder as well as the piston due to repetitive action. All duble acting cylinders excepting for small sizes, are provided with end position cushioning arrangement. This arrangement decelerates the piston motion as it approaches the end of the stroke Double ended piston rod type Pneumatic cylinders operates at much higher speeds than hydraulic cylinder. Due to this, there is a tendency of the piston to ram against the end covers as the piston approaches the ends at high velocity especially in cylinder with large mass. This impact force can damage the cylinder as well as the piston due to repetitive action. All duble acting cylinders excepting for small sizes, are provided with end position cushioning arrangement. This arrangement decelerates the piston motion as it approaches the end of the stroke

Rod less type Different operational principals are used for the construction of rod less cylinders: Cable cylinder Sealing band cylinder with slotted cylinder barrel Cylinder with magnetically coupled slide Rod less cylinder have the following advantages: Available in long lengths – up to 4 m or even higher (as there is no buckling) Most ideally suited for stopping and fixing (robotic application) Occupies less space as the extension rod is not present Rod less type Different operational principals are used for the construction of rod less cylinders: Cable cylinder Sealing band cylinder with slotted cylinder barrel Cylinder with magnetically coupled slide Rod less cylinder have the following advantages: Available in long lengths – up to 4 m or even higher (as there is no buckling) Most ideally suited for stopping and fixing (robotic application) Occupies less space as the extension rod is not present

Rod less cylinder with magnetic coupling This cylinder has a hermetically sealed arrangement where piston is housed inside a sealed cylinder barrel. The piston is provided with number of annular ring magnets, radially polarised. An external sleeve which slides over the cylinder, is also provided with similar arrangment of ring magnets. Thus a magnetic coupling is establised between the piston and slider. As the piston reciprocates due to supply of compressed air, the slider also reciprocates oven the clinder. Rod less cylinder with magnetic coupling This cylinder has a hermetically sealed arrangement where piston is housed inside a sealed cylinder barrel. The piston is provided with number of annular ring magnets, radially polarised. An external sleeve which slides over the cylinder, is also provided with similar arrangment of ring magnets. Thus a magnetic coupling is establised between the piston and slider. As the piston reciprocates due to supply of compressed air, the slider also reciprocates oven the clinder.

Rod less cylinder mechanically coupled The cylinder barrel is provided with a slot across the entire length. The force is transmitter through a slide permanently connected to the piston. The connection from piston to slide is directed outwards through the slotted cylinder barrel. The slot is sealed by means of a sealing band, which seals the inside of the slot. The sealing band is guided between the piston seals and passed under the slide. A second metallic cover srtip, covers the slot from the outside to prevent the ingress of dirt. Rod less cylinder – mechanically coupled The cylinder barrel is provided with a slot across the entire length. The force is transmitter through a slide permanently connected to the piston. The connection from piston to slide is directed outwards through the slotted cylinder barrel. The slot is sealed by means of a sealing band, which seals the inside of the slot. The sealing band is guided between the piston seals and passed under the slide. A second metallic cover srtip, covers the slot from the outside to prevent the ingress of dirt.

Vane type rotary actuators A rotating vane connected to a shaft divides cylindrical chamber in to two compartments. Compressed air is alternately admitted and exhausted from the chambers. The compressed air pressure acting on the vane surface results in a torque. Hence rotary motion is obtained. The magitude of the torque produced, depends on the surface area of the vane, air pressure and mean radius of the vane. Rotary actuators A rotating vane connected to a shaft divides cylindrical chamber in to two compartments. Compressed air is alternately admitted and exhausted from the chambers. The compressed air pressure acting on the vane surface results in a torque. Hence rotary motion is obtained. The magitude of the torque produced, depends on the surface area of the vane, air pressure and mean radius of the vane.

Direct Control of a double acting cylinder The only difference between a single acting cylinder and a double acting cylinder is that a double acting cylinder often uses a 5/2 directional control valve instead of a 3/2 directional control valve. The double acting cylinder can be reversed either by a 4/2 directional or 5/2 directional control valve. Direct Control of a double acting cylinder The only difference between a single acting cylinder and a double acting cylinder is that a double acting cylinder uses a 5/2 directional control valve instead of a 3/2 directional control valve. The double acting cylinder can be reversed either by a 4/2 directional or 5/2 directional control valve. In the normal position of the 5/2 directional valve, P is connected with B and A with R. By operating the pushbutton the valve reverses. P is connected with A and B with S. The piston of the cylinder travels from the rear to the front end position. Push In the normal position of the 5/2 directional valve, „1” is connected with „2” and „4” with „5”. By operating the pushbutton the valve reverses. „1” is connected with „4” and „2” with „3”. The piston of the cylinder travels from the rear to the front end position.

Direct Control of a double acting cylinder In the normal position of the 4/2 directional valve, „1” connected with „2” and „4” is connected with „3”. By operating the pushbotton, the valve reverses. „1” is connected with „4” and „2” with „3”. The cylinder piston travels from the rear to the front end position. Direct Control of a double acting cylinder In the normal position of the 4/2 directional valve, „1” connected with „2” and „4” is connected with „3”. By operating the pushbotton, the valve reverses. „1” is connected with „4” and „2” with „3”. The cylinder piston travels from the rear to the front end position. Push

Memory function Memory is a common basic function. It can keep a component at a certain state permanently until there is a change of signals. The drawn shows a memory function circuit. When control valve (1) is operated momentarily (that is, pressed for a short time), the output signal of the 5/2 directional control valve (3) will be set to ON. The signal will stay that way until control valve (2) is operated momentarily and generates another signal to replace it, causing it to stay permanently at OFF. Memory function Memory is a common basic function. It can keep a component at a certain state permanently until there is a change of signals. The drawn shows a memory function circuit. When control valve 1.1 is operated momentarily (that is, pressed for a short time), the output signal of the 5/2 directional control valve 1.3 will be set to ON. The signal will stay that way until control valve 1.2 is operated momentarily and generates another signal to replace it, causing it to stay permanently at OFF.

Indirect control of a double acting cylinder A double acting cylinder is to be controlled by two valves (1.2 and 1.3) such that the piston travels out when valve 1.2 is operated, and also remain stationary in the forward end position when valve 1.2 is released until the reverse signal is input through valve 1.3 for the return movement. I. step II. step III. step Indirect control of a double acting cylinder A double acting cylinder is to be controlled by two valves (1.2 and 1.3) such that the piston travels out when valve 1.2 is operated, and also remain stationary in the forward end position when valve 1.2 is released until the reverse signal is input through valve 1.3 for the return movement. PUSH PUSH

Indirect control of a double acting cylinder A double acting cylinder is to be controlled by 5/2 directional control valve. The 5/2 double pilot valve is bi-stable therefore the push button valves only need to be pulsed. I. step II. step III. step Indirect control of a double acting cylinder A double acting cylinder is to be controlled by 5/2 directional control valve. The 5/2 double pilot valve is bi-stable therefore the push button valves only need to be pulsed. PUSH PUSH

Automatic return of a double acting cylinder The following methods are commonly used to interrogate the end positions of piston in the cylinder: Mechanically operated limit switches (roller lever or idle return roller type) Reed sensor, either with electrical or pneumatic out put (the piston is incorporated with ring magnet) Electrical proximity switches Pneumatic signal switches Automatic return of a double acting cylinder The following methods are commonly used to interrogate the end positions of piston in the cylinder: Mechanically operated limit switches (roller lever or idle return roller type) Reed sensor, either with electrical or pneumatic out put (the piston is incorporated with ring magnet) Electrical proximity switches Pneumatic signal switches

3/2 way roller lever valve As a signaling element the directional control valve is operated for example, by a roller lever to detect the piston rod position of a cylinder. Reduced actuation force through pilot control Conversion from normally closed position to normally open position by exchanging ports 1 and 3 and repositioning the upper part of the housing by 180 ̊. 3/2 way roller lever valve As a signaling element the directional control valve is operated for example, by a roller lever to detect the piston rod position of a cylinder. Reduced actuation force through pilot control Conversion from normally closed position to normally open position by exchanging ports 1 and 3 and repositioning the upper part of the housing by 180 ̊.

Semi-automatic control Manual remote start of a double acting cylinder with automatic return Cylinder identified as “C1” Trip valve operated at the completion of the plus stroke identified as “S11” C1 I. step II. step C1 C1 III. step Semi-automatic control Manual remote start of a double acting cylinder with automatic return Cylinder identified as “C1” Trip valve operated at the completion of the plus stroke identified as “S11” After reaching the forward end position, the piston of a double acting cylinder is to return by itself, provided the valve (pushbutton) which initiates the advance movement is no longer actuated. Manual push Mechanic push

Fully-automatic control Continuous automatic cycling from roller operated trip valves. Manual run and end of the automatic cycling. Cylinder will come to rest in the instroked position regardless of when the valve is put to end. Tags for the roller feedback valves S10 and S11 show their relative positions. I. step II. step III. step Fully-automatic control Continuous automatic cycling from roller operated trip valves. Manual run and end of the automatic cycling. Cylinder will come to rest in the instroked position regardless of when the valve is put to end. Tags for the roller feedback valves S10 and S11 show their relative positions. Mechanic push Mechanic push Manual push

Thank you for your attention! Köszönöm a figyelmet! Thank you for your attention!