WACH4 26/11/2002Julien Cogan CERN/EP/CMA-1- M0 COOLING IN H4 Cooling is a key issue : –APD gain : ~ -2.4 % /  C –XTAL response (scintillation) : ~ -1.9.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

Manchester 09/sept/2008A.Falou & P.Cornebise {LAL-Orsay}1 CALICE Meeting/ Manchester Sept 2008 SLAB Integration & Thermal Measurements.
Rosier Ph. – IPNO – Detector Dpt. – 27/05/2011APRIME HPS collaboration meeting 1/24 1- Vacuum chamber proposal 1.1- Stainless steel chamber design and.
RBX Cooling Dan Karmgard for the HCAL RBX Group. 1 Mar 01 2RBX Production Readiness Review - D. Karmgard, University of Notre Dame Outline Introduction.
PRR TRD COOLING A. Marín (GSI) 7/01/2004 ALICE PRR TRD COOLING P.Glässel, A.Marín, V.Petracek, J.Stachel, M.R.Stockmeier, J.P.Wessels ALICE PRR TRD COOLING.
US ITER TBM Meeting Idaho Fall, Idaho, Aug M Dagher P Fogarty 1.TBM/ITER General Arrangement 2.Equatorial Test port Configuration 3.Test Port.
Cooling Update (May 2011) Tim. Overview From last time – Estimate Power Loads Active components Extraneous heat sources – Develop methodology for exploring.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
1Snowmaker Transfer of Snowmaker Construction Plans WSL Institute for Snow and Avalanche Research SLF Martin Schneebeli, Matthias Jaggi Davos, 27th May.
FAZIA DAYS, Bologna 10-12/feb/2010, WG8, Emanuele Vanzanella (mechanics & cooling), Alfonso Boiano (electronics) ELECTRONICS HOLDER & COOLING SYSTEM Side.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski and M. D. Hageman Woodruff School of Mechanical Engineering Update on Thermal Performance of the Gas- Cooled.
21/01/02 - ECAL Cooling - Arnaud Hormiere ST/CV 1 Development of ECAL COOLING PLANT Application to a Super Module.
1 Denis Grondin / Julien Giraud – 01 December 2008 SLAB COOLING Denis Grondin Julien Giraud
Status of TRD Chamber and Readout Electronics Integration Ken Oyama and Christian Lippmann for the TRD Collaboration Sep. 26, 2005 TRD status meeting in.
B. IlleWACH /11/20021 WELCOME to WACH I am happy to introduce this ‘Workshop Analysis Calorimetry H4’ dedicated to M0’ data analysis and the.
Vacuum system.
4/12/2011Controller Cooling Test1 Array Controller Cooling Test Bill Hoffmann April 12, 2011 This is a report on a test of the chilled water-to-air heat.
Tariq J. Solaija, NCP Forward RPC EDR, Tariq Solaija Forward RPC EDR The Standard RPC for low  regions Tariq J. Solaija National Centre for.
NML High Energy Beam Absorbers and Dump 29-August-2011 Beams-doc-3928.
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
PSB dump: proposal of a new design EN – STI technical meeting on Booster dumps Friday 11 May 2012 BE Auditorium Prevessin Alba SARRIÓ MARTÍNEZ.
Mechatronics Task Force, 26-nov-02 Olivier Teller, CERN EP-CMA1 Cooling Mechatronics Schedule.
07-Jan-2010 Jornadas LIP 2010, Braga JC. Da SILVA Electronics systems for the ClearPEM-Sonic scanner José C. DA SILVA, LIP-Lisbon Tagus LIP Group * *J.C.Silva,
COOLING & VENTILATION FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 16/9/2009 CLIC TWO BEAM MODULES REVIEW
1 Thermal tests planning for mock-up TM0 Thermal tests planning for CLIC prototype module type 0 May 30th,
AEP Mechanical and Power System H. Heetderks. CDR July, 2001NCKU UCB Tohoku AEP Mechanical and Power System H. Heetderks 2 AEP Mechanical Design System.
Presentation at BBC, Linac 4 Commissioning Dump at 50 and 100MeV 1 Øyvind Dahle Lauten, EN-STI.
Jan. 28, 2014W. Bertl, PSI BPIX Cooling Status W. Bertl, PSI.
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Shield.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Coordinate Detector: prototype design General idea about the Coordinate Detector (CDET) so far: Three independent vertical planes with 15 cm plastic shield.
27/11/02Paul Baillon wach Paris1 Heat transfer study in M0’ using the thermistors on the APD’s and on the boards.
H. Katajisto RE EDR 10/10/02 Enclosures for the RPC Link Boards Outline Introduction Periphery General Services Components, materials Manufacture, Assembly.
The integration of 420 m detectors into the LHC
ATF2 Magnets ATF2 Magnets 14 Sep 2007Cherrill Spencer, SLAC. Cooling Solid Wire Sextupoles 1 Report of the effort to cool an old FFTB solid wire sextupole.
WACH4 26/11/2002Julien Cogan CERN/EP/CMA-1- THERMAL STEPS ANALYSIS Goals & Means : –apply a “step function” on the cooling water –look at : APD response.
Aachen Status Report: CO 2 Cooling for the CMS Tracker at SLHC Lutz Feld, Waclaw Karpinski, Jennifer Merz and Michael Wlochal RWTH Aachen University, 1.
Henryk Piekarz SC Magnets at Fermilab HTS Cable Test for a Fast-Cycling Accelerator Dipole Magnet E4R Test Goals and Arrangement Review September 10, 2009.
Thermal screen of the cryostat Presented by Evgeny Koshurnikov, GSI, Darmstadt September 8, 2015 Joint Institute for Nuclear Research (Dubna)
RFQ coupler S. Kazakov 07/28/2015. Requirements: Coupler requirements Expected problems: Heating (loop, ceramic window, etc.) Multipactor Solutions: Appropriate.
Engineering of the power prototype of the ESRF HOM damped cavity* V. Serrière, J. Jacob, A. Triantafyllou, A.K. Bandyopadhyay, L. Goirand, B. Ogier * This.
13 Januar 2011 Immanuel Gfall (HEPHY Vienna) Annekathrin Frankenberger (HEPHY Vienna) SVD Cooling Cooling Meeting Karlsuhe.
24 September 2012 Immanuel Gfall (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
SPS High Energy LSS5 Thermal contact & cooling aspects
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Air-cooled Modular Chiller Installation
CMS GEM services: Cooling
"Drawer Mechanics - MiniDrawer"
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Status of GASPARD mechanics
Service channels between Tracker and PP1
The EMC cooling F. Raffaelli INFN - Pisa 06/09/2017.
Calorimeter Mu2e Development electronics Front-end Review
SCADA for Remote Industrial Plant
Nikhef/Bonn LepCol meeting
Manufacturing of the first FCC-hh beam screen prototype for ANKA
VELO Thermal Control System
cooling and supports of the forward endcap EMC
Performance of an Automated Water Based Cooling System for CBM MuCh
Pixel cooling specifications
Mechanics for front-end Electronics Of T2K-II TPCs – A Few Conceptual Ideas D. Calvet, Irfu, CEA Saclay, Gif sur Yvette Cedex, FRANCE.
CALICE Collaboration Meeting at UT Arlington
Recirculating CO2 System
Dr John Fletcher Thermal Management Dr John Fletcher
Tests on a dummy facet of PIX upgrade using CO2 cooling
SNS PPU Cryomodule Instrumentation
PANDA Collaboration Meeting
SNS PPU Cryomodule Instrumentation
Presentation transcript:

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-1- M0 COOLING IN H4 Cooling is a key issue : –APD gain : ~ -2.4 % /  C –XTAL response (scintillation) : ~ -1.9 % /  C (“nominal values” from “old” measurements) Strict requirement : –contribution to  (E)/E : < 0.5 % –avoid to apply correction –  constant temperature of XTAL & APD :  0.05  C Goals in H4 this year : –provide stable conditions for the data taking –validate some cooling principles for the future (cooling units, VFE cooling) –better understanding of the system heat transfer (electronics  ADPs & XTALs) dynamic of the system (characteristic time constant of ADPs & XTALs)

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-2- OUTLINE M0 cooling : –mechanic –cooling units & circuits –next year strategy Thermal stability during the data taking : –water circuits –environment –APDs (capsules) –failures Thermal studies (covered in next talks) –heat transfer, temperature rise when electronics is turned on (P. Baillon) –temperature steps (Roberto Salerno, J. Cogan)

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-3- COOLING MECHANIC (1) Bare module = fully equipped module with 400 crystals –final grid (cooled through 9 holes drilled along z) –thermal shield ( attached to the APD connector mechanical assembly 10 lines) –special thermal screen (2 layers of pipes around the 5 faces of the crystal basket) –module isolated from its support by 4 cooled blocks of aluminum –module isolated from the environment by 4 cm of rock wool

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-4- COOLING MECHANIC (2) Electronics = 20 VFE cards  10 blocks  100 channels – FPPA + ADC + GLINK (+DRIVER) (  ~2.5W/Ch) –copper housing manufactured to compensate for the different height of the components (minimal thickness = 0.7 mm) –0.5 mm thick gap pad between the copper housing and the components + contact at the bottom of the cards (1 mm thick  4 mm wide gap pad) –10 lines of cooling pipes (  3/4 mm) brazed on the copper housing

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-5- COOLING UNITS & CIRCUITS (1)

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-6- COOLING UNITS & CIRCUITS (2) Regulating circuit : flows through the grid and then on the thermal shield –q = 0.22 l/s (80 % of nominal flow) –  T(OUT-IN) typically few 1/100  C –water regulation and circulation done by a LAUDA Ambient circuit : flows in the thermal screen and on the insulating al. blocks –q  0.1 l/s –  T(OUT-IN) typically few 1/10  C –water regulation and circulation done by a LAUDA Power circuit : cools the VFE boards –q  0.14 l/s (M0) (+ ~0.14 l/s by pass) –  T(OUT-IN) typically few 1/10  C ;  P  1.5 bar –water under pressure (P~2.5 bar) –water regulation and circulation : heat removal : chilled water + heat exchanger water regulation : heater (max = 2kW) controlled by a regulator (PID)

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-7- NEXT YEAR STRATEGY Cooling circuit : only one circuit –cooling unit similar to this year power circuit –work is in progress (dimensioning of the circuit, buying of the elements, control loop) Cooling of the electronics (is being decided) –from cooling point of view : same principle as this year (?) –mechanically : cooling bars instead of brazed tubes (?) –introduction of a mother board and additional kapton cables between the VFE and the APD connector PID Simplified schematic of the foreseen cooling unit Mixed water 14.5  C 17.8  C 18.8  C 17.8  C

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-8- SHORT-TERM STABILITY : WATER (1) Regulation circuitPower circuit INLET OUTLET 0.05  C 1 week

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-9- LONG-TERM STABILITY : WATER 0.05  C Regulation circuit Power circuit INLET OUTLET 3 months (aug/sept/oct) 2 o’clock jumps Lauda remote control off Power cut ?

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-10- STABILITY : ENVIRONMENT Room (measured on a copper plate near the module) MEM (output water temperature) 2  C 3 months (aug/sept/oct) 1  C Ambient circuit (inlet & outlet) 2  C 0.5  C Primary circuit (inlet) out of water

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-11- STABILITY : CAPSULES 3 months (aug/sept/oct) 0.1  C LV block A LV block B 0.1  C

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-12- STABILITY : FAILURES Laudas remote control : –setting of the Lauda controlled by a computer (to be able to change the temperature form the control room) –induce instabilities and mysterious jumps (  ~0.02  C) at 2 AM (related to computer activity ?) –remote control disabled after 2nd temperature step (16/08/02) : small change in the setting (  ~0.02  C ) Chilled water failures : –Pb with chilled water in the area happened twice (last for less than 1 day) : 12/08/02 23/09/02 –induced a rise of temperature of the power circuit (~1  C ) –induced a small rise of temperature on the APD

WACH4 26/11/2002Julien Cogan CERN/EP/CMA-13- CONCLUSION STABILITY : –Generally good thermal stability during all the data taking : constant temperature of the cooling water well within 0.05  C constant temperature of the capsule well within 0.1  C –  Probably no need to correct for temperature effect –Very few failures M0’ cooling system: –validation of some principles for : cooling units VFE cooling –give confidence for the future