Fresh water system. Matter to be decided: Potable water Wash water Pressure in the system: usually 10 to 40 psi 69 to 275 kPa 0.69 to 2.75 bar.

Slides:



Advertisements
Similar presentations
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
Advertisements

International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Unit 206: Domestic hot water systems
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
CAFS On-Line Orientation
GNI0003H PP1 Loop Trainer. GNI0003H PP2 Reason for Study Because the Loop Trainer gives instructors the capability to control water flow, pressure and.
Salt water system. Function Hot Domestic service Cold Domestic service Fire main Sprinkler system Deck Wash Ballast system Engine and Equipment cooling.
DEWATERING PUMP.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
Unit 206: Domestic hot water systems
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
Unit 205: Cold water systems
Outcome 2 Materials used to install domestic central heating pipework Unit 208: Central heating systems.
Unit 205: Cold water systems
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Unit 206: Domestic hot water systems
Pump Installation Vigyan Ashram, Pabal.
STEAM CONDENSERS.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
Mechanical for Oil Heat
Hydraulics For The Long Term
Preventative Maintenance & Troubleshooting
HVAC523 Basic Subsystems.
Air Conditioning in tropical climates Presented by Ranjeet Kumar Nayak.
Residential Construction Unit 5 Energy Efficiencies and Mechanicals Mr. Todzia.
BUILDING MATERIAL BUILDING MATERIAL PALESTINE UNIVERSITY chapter No.#7 Mechanical Works Dr. Ali Ibrahim Tayeh.
EMISSION PROBE PARTS TUBE: 3/8” OD x wall Stainless Steel Length determined by pipe diameter and placement of connecting end to allow easy connection.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
LESSON THIRTEEN LUBRICATING OIL SYSTEM. 1.PRIMARY PURPOSE OF LUBRICATION To keep a clean layer of lubricating oil film / luboil film between the contacting.
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.
Dental radiology د. باسم الاعسم.
At the Ballarat City Gate Construction and Commissioning of a Shell and Tube Heat Exchanger Speaker: Godwin Wong.
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Unit 209: Drainage systems
The C.I. Engines Fuel System  The C.I. engine demands that the fuel supplied is –  Timed to inject when the piston is near the end of the compression.
Unit 209: Drainage systems
Boiler Safety Valve Regulations
REFRIGERATION SYSTEMS Er. Gagandeep kaur Associate Prof., Electrical Engg. PTU Giani Zail Singh Campus, Bathinda. Id:
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Air source heat pump Understand the fundamental principles and
UNIT III ENGINE SYSTEMS
Plumbing system fundamental and design course
Unit 37: Fluid containment Dr
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
14 Refrigerant Recovery, Recycling, and Recharging.
Heating Ventilation and Air Conditioning
RESIDENTIAL PLUMBING SYSTEMS (WATER SUPPLY)
Unit 37: Fluid containment Dr
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
Fuel Supply System Service
Hot water Systems Heaters.
Auto Upkeep Basic Car Care, Maintenance, and Repair (2nd Edition)
MINI 1A iAquaMax™ Kidney / water removal system
Hot Water Systems Cylinders and Systems.
Introduction of fuel feed system
1A iAquaMax™ Kidney / water removal system
Boiler Safety Valve Regulations
Presentation transcript:

Fresh water system

Matter to be decided: Potable water Wash water Pressure in the system: usually 10 to 40 psi 69 to 275 kPa 0.69 to 2.75 bar

Pressure set is a unit consists of: Pump (usually displacement type) Accumulator tank Pressure switches: high and low pressure

Accumulator tank

Accumulator tank benefits: Absorbs the pulsations in supply from the pump (works as air vessel) Extends pump life Reduces battery drain

Choice of the pressure set Decide how many outlets you require What flow is required from each outlet (from manufacturer specification) Estimate how many outlets will be opened simultaneously Decide your maximum normal flow requirement Choose the pump according to that flow and the chosen pressure

Carbon based water filter Filters, freshens and cleanses stored water to give a fresh, clear, natural taste Activated carbon removes unpleasant tastes, smells and colours, including chlorine Removes suspended dirt, sediments and fibres Silver impregnating inhibits bacterial growth when not in use

Water heaters (Calorifiers ) Heat Transfer – cooper coils with engine cooling water, heat accumulator Electric Elements -The rating should not exceed watts, thermostat is required Calorifier Valves – non-return valve pressure relief valve drain tap Insulation - polyurethane foam, some companies quote a 0.5°C loss per hour Installation - The calorifier should be mounted on the same level as the engine cooling water source or below

Diesel Hot Water Heaters

Instantaneous water heater Electrical – 6kW for shower – 3 Litres/min LPG If the choice is LPG read installation requirements on boats. Web info:

Fresh water tanks Integral in mild steel, aluminium, GRP or wood vessels then the tank internal surfaces need to be coated with an epoxy based paint approved for drinking water use. Separate tanks. The tanks may be constructed from any material if internally coated. Usual practise is to use stainless steel (A1S1 316L) which, like purpose built GRP separate tanks (with GELCOT on the inside) do not require coating internally.

Water consumption Add 15% to 25% margin for emergencies, excessive consumption, etc.

All tanks should be supplied with the following: (a) Filling pipe work of adequate size, (b) Air ventilation pipe led as high above the main deck as possible, incorporating a swan neck and mesh filter, (c) Manual sounding tube for dip stick use to check capacity of tank, (d) Tank outlet to be of sufficient size and led from point of tank via internal pipe if necessary, (e) Suitable fitting for remote sensing of tank levels (electric, mechanical or pneumatic), (f) Inspection man-hole of suitable size to allow visibility and access (g) To be appropriately baffled.

Fresh water tanks location double bottom or bilge area obviously to maintain a lower VCG and maybe divided fore and aft to supply the accommodation in the ends of the vessel

Some rules and considerations 1. Install the pump as close as possible to the water supply tank, consistent with a dry, ventilated & accessible location. correct incorrect

Some rules and considerations 2. Keep suction pipework as short and straight as possible with minimum suction lift. Use rigid pipe or reinforced hose that will not deform or collapse under suction conditions. Ensure that all connections are airtight. correct incorrect

Some rules and considerations 3. The internal diameter of the suction pipe should be at least as large as the nominal bore of the pump ports. correct incorrect

Some rules and considerations 4. Fit a suction line strainer between supply tank and pump. Make sure that it is accessible, and remember to inspect it periodically. correct incorrect

Some rules and considerations 5. Avoid transparent / translucent pipework, which is susceptible to algal growth./ correct incorrect

Some rules and considerations 6. Use discharge pipework of adequate size — 13mm (1/2”) internal diameter in small systems. In larger vessels, use 13mm (1/2” branches to taps etc. from a 19mm (3/4”) or 25mm (1”) main pipe running the length of the vessel. correct incorrect

Some rules and considerations 7. Check that pump cut-out pressure is suited to all other system components, e.g. calorifier. correct incorrect

Some rules and considerations 8. Always fit an accumulator tank — the larger the better. correct incorrect

Some rules and considerations 9. After refilling an empty supply tank, open one outlet before switching on the pump. This allows the pump to re prime itself rapidly.. correct incorrect

Design details to be considered when developing a freshwater system are as follows: Bolted connections should not be made through the shell of potable water tanks, Pumps, manifolds (filling, transfer, and suction), and gauges should be grouped, Potable water services should be grouped to keep the number of branches from the main to a minimum, Service branch sizes should be based on the number of fixtures installed. All risers exposed to the weather should have means for draining to prevent freezing,

Potable water piping should not be run through bilges. All branch connection to the main freshwater system should be provided - with stop valve, A non-return valve should be installed in the supply to water heater, to prevent hot water from backing up in the cold water piping, Gauge glasses should have guards, or be otherwise protected against accidental breakage

In addition Additional requirements regarding freshwater systems are contained in the regulations of the Public Health authority involved. A thorough understanding of these regulations should be obtained before undertaking the design of a freshwater system for commercial and passenger vessels. In these cases fresh water supplied for drinking and culinary purposes must meet purity standard specified by the Department of Transport. Water produced from most evaporator/distillers will not meet these standards and must be treated to ensure it is biologically pure and neutral or slightly alkaline.