System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.

Slides:



Advertisements
Similar presentations
BUILDING AIR CONDITIONING
Advertisements

CON 4003 Construction Estimating Prof R. V. Locurcio.
Fan Coil Unit Product Line-up. FCU Home Application Show.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Heating, Ventilating, and Air-Conditioning
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Just How Bad Could It Be….. Presented by: Phil Rawlings, CGD Director Of Geothermal Services TRC Energy Services - Geothermal.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Components of HVAC System
1 HVAC SHEET METAL SHEET METAL THEORY. 2 THE AIR DISTRIBUTION SYSTEM SHEET METAL IS USED FOR: – PLENUM’S (RETURN & SUPPLY) –TRUNK LINES –RETURN AIR GRILLS.
Zoning Application. Copyright 2011 Trane 2 Zoning Application Agenda Application Overview --Benefits & Challenges with Zoning HVAC System Designs Conventional.
Airflow Properties & Measurement
HEAT LOAD ESTIMATING USING THE SHORT COMPREHENSIVE METHOD © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Siemens TAVS Terminal Air Valve Selection Software Evan Himelstein, P.Eng. Application Engineering Price Industries Joe Sam Senior Solutions Developer.
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
HVACR416 - Design Air Distribution Air Properties and Behavior Important properties of interest include: o Weight of air. o Manner in which air.
STEAM HEATING.
Generation Geo. EXPECTED SAVINGS Savings vary by region and energy costs Savings happen large or small homes Natural gas prices today are artificially.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Hi-Velocity Tubing Runs. How to get it where you need it! System Installation copyright Mestek, Inc
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
General Troubleshooting Tips.
Ductless Heat Pumps Sizing Example
Copyright Mestek, Inc What’s High Velocity Air Conditioning?
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Plenum Runs Plenum Runs. Plenum Run Usually located in the attic or basement. Run in any location accessible for attachment of supply tubing. More economical.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Air Handler Terminology
Trade Skills Print Reading and Ductwork. 2 Drawings are a useful tool in manufacturing and construction because most people find it difficult to.
Air Handler Terminology
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Drafts and Duct System Sizing
HVACR416 - Design Air Distribution Part 2. Air Ducts Air carriers that deliver air to conditioned space. Originally hot air ducts were thin, tinned sheet.
System Components Let’s take a look at the Spacepak System Components.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Ductwork Systems and Supply Arch 432. What You Need To Know Become familiar with the materials sizing ductwork Understand sizing units.
Unico, Inc A Family-owned St. Louis Company Sold Worldwide.
AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.
SYSTEM SELECTION & SPACE REQUIREMENTS INTRODUCTION SYSTEM SELECTION SPACE REQUIREMENTS SAMPLE QUESTIONS.
What makes up a Unico System
Return Air Installation Return Air Installation. Installation Fundamentals Check the electrical service Room by room load calculation Select a matched.
EXAMINATION 3 REVIEW FORMAT & AREAS COVERED DISTRIBUTION SYSTEMS DELIVERY DEVICES UNITARY SYSTEMS HEAT PUMPS SPACE REQUIREMENTS & DESIGN CONSIDERATIONS.
Duct Design Basics Lesson 4 Manual D Primer. Duct Sizing 4.3.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Sound Attenuator (UPC-26C)
Mastering Autodesk Revit MEP 2016
Technology in Architecture
Doug Jefferson, Business Development Engineer
Ritchie Yellow Jacket Instrument Applications
Unico Installation Rules
Sound Attenuator (UPC-26C)
High Performance HVAC Installation
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Adding Zones to Existing Systems
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
FBE03: Building Construction & Science
Announcements Exam 1 Next Class (Thursday, March 14th):
Objective Revie the Cooling Cycle Learn about air distribution systems
Liebert DSE High efficiency thermal management
Presentation transcript:

System Sizing

Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks

The Next Step Kwik-Way Room By Room Load Calculation Contractor assistance

Load Calculation Essential for a properly performing job Shortcuts are not encouraged BTUs not CFM!!! Loads give you net values Equipment discussed in nominal values

Load Exceptions Sensible vs Latent Don’t add 1/3rd for latent Sunrooms Where does it face? Commercial applications Exceptional heat sources?

Load Calculation ACCA Manual J Industry Standard Currently revision 8 Not for commercial loads Cautions in rooms with large glass areas Use peak function for large glass areas

Kwik Way Runs from Internet and then contractor assistance ation.htm ation.htm Quick program Free Does not keep files, must print out Skip to Equipment Selection

NEXT

This was done off internet…. Room by room analysis. Totals load and suggests model and size. Nice presentation tool. Want a CD? Ask you salesmen….

ALTITUDE CORRECTION determine atmospheric pressure at given altitude Step One Altitude Pressure = x( E-06xA) Where: A = altitude in feet

Step Two Correct CFM for Altitude Corrected CFM = xaxb x(c ) Where: a=pressure at altitude, b=specific CFM, c=entering air temperature ALTITUDE CORRECTION

Equipment Selection Check systems capacity chart Match to the load calculation Data on internet Use mix match systems

ARI Listing (edited) Model # SpacePak #MfrSEERMatched capacityAEU AC024X1222AC024X ESP-2430V+TDRLUXAIRE, * * $171* AC024X ESP-2430D+TDRLUXAIRE, * * $171*AC024X1222

System Design Let’s do a house!

My Mother-In-Law’s house

80’s Ranch. On a slab Attic space available Windows are double pane, low “e” Walls are R13 Ceilings are 8’ R19 Heated with boiler and baseboard (cooling only) 70 by 38 ft.

This was done on internet…. Room by room analysis. Totals load and suggests model and size. Nice presentation tool. Want a CD? Ask your salesmen….

Where do I fit the Equipment in ? Look for a central return grill spot Horizontal or Vertical Unit Spacepak in the attic or basement Reaching the other floors w/ 2” “I want the condenser behind the garage” Commercial and multi-zone systems

Where to Place the Return? Central Location – Out of Direct Living Area

Air Handler Location 1. Return Air Duct Dictates Unit Location Best Location for Return Air Grill Split Return Air? 2. Unit Location Dictates Trunk Layout Best Option for Trunk Layout? 3. Outlet Location: Dictates Trunk Run – How Many Outlets, Where do they go?

Air Handler Location ESP-3642

Outlet Location ESP

Restrictors and Balancing: Each 2”run will provide between btu at a run length of 10’-20’ 3 restrictor sizes 15%, 30% and 50% Living room = 3 full runs Family room = 5 full runs How about the Dining room? Needs two outlets but gain is only 2800 btu. Use 2 30% restrictors on both runs. = 2800 btu Runs must total 19 full open for 3642D – 850 CFM to get ESP to 1” and 1.5” W.C.

Outlet Location ESP > <

High Static Plenum Short runs Short runs Long runs Will this pull on fitting?

Considerations: Want to keep runs as close as possible to 10 feet in length. Full 40 cfm and 2000 btu per outlet makes it much easier to balance….. Generally less $$$ to run supply plenum extra distance than run long 2” runs. Want to “premake” the 2” runs downstairs where it’s nice and cool!!!!

Suggested Layouts

Plenum Connection ESP > <

Estimating The Job Good measurements can make you money Old homes are gold but full of surprises Refer to Spacepak’s Typical equipment list Two sizes fit all Spacepak is a premium product Selling the extras

Airflow Considerations Spacepak min. required outlets 14, 19, 26 Split or extended return duct Filters New air handler, old system

We Never Undersize Conventional systems undersize for humidity removal Difficult to keep up on 100° days Space Pak’s 6 row coil Humidity control built in Size for the worst day