1 MASSACHUSETTS UNDERGROUND STORAGE TANK (UST) PROGRAM Baseline Compliance Assessment 1 MassDEP 8/2/2011.

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

Spill and Overfill Prevention
Waste Ban Compliance Training Program Administrative Compliance Requirements April and May 2006 Administrative Compliance Requirements April and May 2006.
Southwest District Storage Tanks Program presented by Leslie Pedigo Southwest District Storage Tanks Program presented by Leslie Pedigo.
Pesticide Container-Containment Regulations: FIFRA 19(f)(2) Determinations of Adequacy.
Managing Environmental Issues with Hospital Expansion Projects Tank, Generator, and Boiler Installations from an Environmental Permitting Perspective Chris.
ACCA Legislative Conference Underground Storage Tank Compliance
Highlights of Colorado’s New Oil and Gas Hydrocarbon Emission Reduction Rules - Adopted February 2014 Presentation to WESTAR May 2014 Will Allison Colorado.
Plans and Preparations for the PST Energy Act Investigations Texas Commission on Environmental Quality Environmental Trade Fair May 5-6, 2015.
DEVELOPING A FACILITY INSPECTION PROGRAM Or How To Make Sure The Facility You Inspect is Operating Successfully Morson Environmental Consulting, Inc.
OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L
Storm Water Pollution Prevention Training
MassDEP Underground Storage Tank Program Program Requirements for Third Party Inspectors Winter 2015 Workshops.
Reducing the Threat of Fuel Release from the Red Hill Fuel Storage Facility A Unique Engineering Challenge.
Release Detection for Piping Spring Types of Piping Safe Suction “Unsafe” Suction Pressurized.
Georgia Environmental Protection Division Stage II Gasoline Vapor Recovery Decommissioning Workshop June 11, 2014 EPD Tradeport Training Room.
Spill and Overfill Prevention Alaska Spring 2004.
Idaho’s UST Program UST Program Summary  Fairly New Program  Energy Act of 2005  Statute Feb  Rules April 2008  State Program Approval.
Underground Storage Tank Compliance Act of 2005 Bill Torrey UST/LUST Regional Program Manager US EPA – New England EBCNE April 19, 2006.
Adem.alabama.gov ADEM Land Division Update Chip Crockett Chief, Industrial Hazardous Waste Branch Air & Waste Management Association Southern Section Pine.
Inspection Directions: An EMS Approach to Inspecting for Section 608 and 609 Compliance.
Environmental Regulations. Learning Objectives TLW understand the history of environmental regulations TLW be able to describe key content of environmental.
March Why is MassDEP proposing new UST regulations? DFS’s regulation: standards for tanks construction, installation, O&M, decommissioning and.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
ISO MONITORING AND MEASUREMENT. ISO Environmental Management Systems2 Lesson Learning Goals At the end of this lesson you should be.
PRODUCT LINE LEAK DETECTION (including a summary of the 2015 UST regulations) Katie Seaborn AMERICAN CONTAINMENT SERVICES, INC. ® Annual GTEC Underground.
Workshop on Permanent Closure of Single-Walled USTs and Funding Opportunities For Closure and Cleanup.
Staying in Compliance Inventory Control Bill Greer GTEC.
BY: Winston G. Smith Environmental Engineer UST/PCB & OPA Enforcement & Compliance Section EPA Region 4.
Joe Stapinski Senior UST Inspector (317)
Overview of 3 rd Party Inspection Program for USTs.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by Travis Benton United Pump and Controls, Inc.
1 1 Staying in Compliance: Spill and Overfill Presented by: Brent Roth OPW Retail Fueling IPECA UST Seminar 2015.
 To discuss MassDEP’s draft revisions to the following regulations:  Stage II – 310 CMR 7.24(6)  Stage I – 310 CMR 7.24(3)  Definitions – 310 CMR.
Release Reporting. How Do I Know If I Have a Leak in My UST System? 1. Unusual operating conditions; such as, erratic behavior of the dispensing pump.
EXCALIBUR GROUP, LLC Evolving Regulations for USTs in New York For New York State August 1, 2013.
1 Final Rulemaking - Chapter 245, Administration of the Storage Tank and Spill Prevention Program (Subchapters A-H) Environmental Quality Board Meeting.
Veeder-Root Company Presents: EPA Compliance Basics Presenters: Bill Tobias, Director of Sales, Veeder-Root Carlton Knowles, Territory Sales Manager, Veeder-Root.
Automatic Gauging Tank System: A Next Generation Tool for UST PROF. HÉCTOR CRUZADO ENGINEERING MANAGEMENT PROJECT MEM 6200-SP-15 JOSÉ J. ROSA ROSARIO STUDENT.
Briefing on Proposed Amendments to Rules for Underground Storage Tank Management, Chapter August 1, 2017.
Edward S. Kubinsky Jr. CROMPCO, LLC
Sump Water Management and Disposal ASTSWMO UST Workshop
UST Inspection Program
2007 EPA Region 4 – Department of Defense – States Environmental Conference June 21, 2007 Atlanta, Georgia.
Underground Storage Tanks New Federal 2015 Requirements
for Compliance, Safety, Prevention
Petroleum Storage Tanks – Program Updates
Underground Storage Tank (UST) Operator Certification Overview
Staying in Compliance: Spill and Overfill
July 13, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
New Install Proposed rule changes
September 8, 2016 Department of Environmental Quality Proposed Amendments to UST Rules 15A NCAC 02N and 02O Ruth Strauss.
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
Operator Training.
COMPLIANCE CHALLENGES FACING OWNERS OF UNDERGROUND STORAGE TANKS
Alabama Tools Seminars
Timothy Veatch, Section Chief
2015 Federal UST Regulation Changes
Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective – 1/11/2017.
Georgia Update Jeff Cown Land Protection Branch
Solano County Department of Environmental Management Environmental Health Services Division Hazardous Materials.
Spill Prevention, Control and Countermeasures (SPCC)
EPA Corrosion Study
NEW COMPLIANCE REGULATIONS
COMPLIANCE VIOLATIONS FOUND DURING INSPECTIONS
Air and Water Management Association Regulatory Conference Symposium
Cupa violation Review BAESG Meeting May 20, 2019 Matthew Burge
Petroleum Storage Tank Rule Updates Complying with the new PST rules and changes to the PST Compliance Notebook Trade Fair 2018 Rebekah Stanush Compliance.
Petroleum Storage Tanks – Program Updates
Compliance Assistance Specialist
Presentation transcript:

1 MASSACHUSETTS UNDERGROUND STORAGE TANK (UST) PROGRAM Baseline Compliance Assessment 1 MassDEP 8/2/2011

2 UST Program UST program was transferred from DFS to MassDEP in July 2009 Between July 2009 and November 2010 MassDEP inspected ≈ 350 randomly selected facilities in order to: –understand “baseline” compliance status of the sector as a whole and –aid in the development and implementation of the regulatory program 2 MassDEP 8/2/2011

3 Main Discussion Topic Compliance with EPA “Significant Operational Compliance” Performance Measures (SOCs) related to: –Release Prevention –Release Detection NOTE: EPA uses different measures to quantify and evaluate the number of spills or leaks that have occurred. 3 MassDEP 8/2/2011

4 UST Program Purpose The UST Program ensures that underground storage tanks do not release regulated substances into the environment The regulated substances include: 4 Gasoline Diesel Fuel oil Waste oil Acids Bases Hazardous substances Solvents MassDEP 8/2/2011

5 UST Program Universe There are: ≈ 3800 active facilities ≈ 9100 registered active tanks These facilities include:  fuel dispensers  industrial operations  hospitals  schools  military bases 5  airports  authorities  Federal, state and local government agencies  small businesses MassDEP 8/2/2011

6 Key Program Requirements Per the Energy Policy Act of 2005: Tank and pipe construction and installation must meet standards that prevent spills and leaks Approved leak detection systems must be in place and operated to identify leaks so that they can be addressed before they become a serious problem Leak detection and prevention systems must be maintained and tested to ensure their proper operation Recordkeeping must be performed to document regulatory compliance Facilities are inspected routinely to insure that the regulatory standards are met (In MA, Third Party and MassDEP inspections are used.) 6 MassDEP 8/2/2011

7 Complexities New program for MassDEP Regulations currently in force were written by another agency (DFS) Regulatory requirements may differ from facility to facility due to the variety of compliance options and UST systems 7 MassDEP 8/2/2011

8 Release Prevention SOCs Spill prevention equipment is present and operating properly Overfill prevention equipment is present and operating properly Tanks and pipes are tightness tested within six months of UST system repairs Corrosion protection systems are tested for functionality within 30 days of UST system repairs Corrosion protection systems are operating and maintained properly Impressed current cathodic protection system is inspected every 60 days Corrosion Protection is in place for all tanks and pipes Note: The SOC “Lined tanks are inspected periodically and lining is in compliance” was not included in the analysis because there were no facilities in the sample to which it applied. MassDEP 8/2/2011

9 Release Detection SOCs Leak detection systems are in place Leak detection systems are operating properly Leak detection systems meet the applicable performance standards Proper response to suspected releases All tanks and pipes are monitored at the required frequency and records are kept Note: The SOC “Hazardous substance USTs meet leak detection requirements” was not included in the analysis because there were no facilities in the sample to which it applied. The SOC “Out of service tanks containing product meet leak detection requirements” was excluded because it is not applicable in MA. 9 MassDEP 8/2/2011

10 “Groups” of UST Facilities Assessed Gas Stations where owner owns >5 facilities ( 27% of universe, sample size = 55) Gas Stations where owner owns < 5 facilities (36% of universe, sample size = 48) Manufacturing / Utilities (10% of universe, sample size = 43) Misc. Small Business & Municipalities (18% of universe, Sample Size = 53) Institutional/State & Federal Government (9% of universe, sample size = 42) MassDEP assessed the performance of a random sample of facilities from 6 individual groups: each of the above categories and early submitters (by 7/1/09) of the required Third Party Inspection reports USTs facilities were grouped into one of five categories : 10 MassDEP 8/2/2011

11 Overall Performance Based on a weighted average of the five facility categories* 85% were in compliance with all EPA Release Prevention SOCs 44% were in compliance with the all EPA Release Detection SOCs 42% of the facilities were in compliance with all EPA SOCs (both Release Prevention and Release Detection) * NOTE: The Third Party Inspection Group was not included in this calculation 11 MassDEP 8/2/2011

12 Massachusetts Assessment Results vs Other States’ EPA SOC Performance Release Prevention Measures –New England: 69% - 86% –National: 45% - 98% Average: 84% –Massachusetts: 85% Release Detection Measures –New England: 68% - 82% –National: 55% - 98% Average: 79% –Massachusetts: 44% All SOCs –New England: 54% - 84% –National: 36% - 90% Average: 71% –Massachusetts: 42% SOURCE: EPA Semiannual Report of UST Performance Measures Mid Fiscal Year 2011 as of March 31, 2011 (5/2011) 12 MassDEP 8/2/2011

13 Overall Facility Performance on EPA Release Prevention SOCS (Weighted average of the performance of each of the five facility categories) MassDEP 8/2/2011

14 Overall Facility Performance on EPA Release Detection SOCS (Weighted average of the performance of each of the five facility categories) MassDEP 8/2/2011

15 Each Group’s Performance on EPA Release Prevention SOCs MassDEP 8/2/

16 Each Group’s Performance on EPA Release Detection SOCs MassDEP 8/2/2011

17

18 MassDEP 8/2/ Requirements Generally Achieved Required Leak Detection Systems are installed and turned on UST systems have adequate corrosion protection Cathodic corrosion protection systems are operating Properly sized spill buckets are installed Overfill protection is installed

19 How Many Individual Requirements Did Facilities Violate? The average facility violated 21% of the requirements that applied to the facility 88% of facilities violated at least one of all of the requirements included in the assessment 58 % of facilities violated at least one SOC Based on a weighted average of the performance of each group MassDEP 8/2/2011

20 Average Facility Violation Score for Each Group % of applicable requirements the facility violated) Gas Station: Owner owns >5 facilities 13 % Gas Station: Owner owns <5 facilities 22% Manufacturing / Utilities 19% Institutional / State & Federal Government 22% Misc. Small Business & Municipalities 28% Facility submitted TPI before July % MassDEP 8/2/2011

21 Facility can document that excess water in tanks was removed and managed as required 43% The past 12 months of release detection records are available for review* 37% Tank inventory records are reconciled monthly35% Automatic line leak detection systems (catastrophic leak detection) have passed the annual functionality test and been certified within the past year* 33% Spill buckets are clean and free of debris31% Facility can document that overfill devices are operable31% The sumps at facilities with interstitial monitoring systems are clean and free of debris and water 29% Facility can document that interstitial monitoring and tank release detection systems have been properly operated, calibrated and maintained* 28% Facility monitors for spills/overfills during fuel deliveries27% Spill bucket waste is properly managed16% Frequently Violated Requirements % of Facilities in Violation MassDEP 8/2/2011

22 Violation Rates for Frequently Violated Requirements by Group MA Wtd Average Gas Station: Owner owns >5 facilities Gas Station: Owner owns <5 facilities Manufac- turing / Utilities Instituti onal / State & Federal Govern ment Misc. Small Business & Municipali- ties Facility submitte d TPI before July 2009 % of facilities violating the requirement Facility can document that excess water in tanks was removed and managed as required 43% 33%41%63%30%59%63% Release detection records for the past 12 months are available* 37% 21%42%43%30%53%38% Tank inventory records are reconciled monthly 35% 10%43%25%53%54%41% Automatic Line Leak Detection systems (catastrophic leak detection) have passed the annual functional test and been certified within the past year* 32% 23%25%60%50%35%14% Spill buckets are clean and free of debris and water 31% 30%27%34%37%16% Facility can document that overfill devices are operable 31% 22%33%22%38%46%27% The sumps at facilities with interstitial monitoring systems are clean and free of debris and water* 29% 22%31%11%21%48%22% Facility can document that interstitial monitoring and tank release detection system have been properly operated, calibrated and maintained* 28% 15%30%23%30%41%21% Facility monitors for spills / overfills during product delivery 27% 19%38%44%10%18%46% Spill bucket waste is managed properly 16% 9%26%9%14%13% 9% *Contributes to an SOC MassDEP 8/2/2011