17-May-15Actual problems of microworld physics. Gomel 2007. Investigation of radiation hard sensors for the ILC forward calorimeter K. Afanaciev, Ch. Grah,

Slides:



Advertisements
Similar presentations
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
Advertisements

17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensor materials K. Afanaciev on behalf of FCAL collaboration.
17-May-15FCAL collaboration meeting. Krakow.. Radiation hardness of GaAs Sensors K. Afanaciev, Ch. Grah, A. Ignatenko, W. Lange, W. Lohmann, M. Ohlerich.
17-May-15FCAL collaboration workshop, Status of sensor R&D in Minsk K. Afanaciev, M. Baturitsky, I. Emeliantchik, A. Ignatenko, A. Litomin, V. Shevtsov.
GaAs:Cr detector testing for FCAL calorimeter at planned linear accelerator ILC V. Elkin, U.Kruchonak XVI научная конференция молодых учёных и специалистов.
Radiation Hard Sensors for the BeamCal of the ILC C. Grah FCAL Collaboration 10 th ICATPP Conference, Villa Olmo.
GaAs radiation imaging detectors with an active layer thickness up to 1 mm. D.L.Budnitsky, O.B.Koretskaya, V.A. Novikov, L.S.Okaevich A.I.Potapov, O.P.Tolbanov,
DIAMOND ACTIVITIES DESY Zeuthen Wolfgang Lange. MOTIVATION and PEOPLE: Calorimetry in an environment with high radiation doses (TESLA beam cal) Beam diagnostics.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Investigation of the properties of diamond radiation detectors
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
Measurements on Single and Poly Crystal CVD Diamond Sensors
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
August 2005Snowmass Workshop Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Radiation Hard Sensors for the Beam Calorimeter of the ILC C. Grah 1, R. Heller 1, H. Henschel 1, W. Lange 1, W. Lohmann 1, M. Ohlerich 1,3, R. Schmidt.
FCAL R&D in Minsk Group: Sensors and Electronics FCAL Collaboration MPI Munich October 17, 2006, Munich, Germany Presented by Igor Emeliantchik.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
3rd NoRDHia 1 TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange,
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
SILICON DETECTORS PART I Characteristics on semiconductors.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
Calorimeter technologies for forward region instrumentation K. Afanaciev 2, R. Dollan 1 V. Drugakov 2, C. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
March 2004LCWS Stanford Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
I n s t i t u t e of H i g h E n e r g y P h y s i c s И н с т и т у т Ф и з и к и В ы с о к и х Э н е р г и й Influence of cooling on the working parameters.
Instrumentation of the very forward region of the TESLA detector – summary of the Workshop on Forward Calorimetry and Luminosity Measurement, Zeuthen,
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
2. December 2005Valencia Workshop Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: - Hermeticity to small polar angles - Fast.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
July 2006ALCWS Vancouver Very Forward Instrumentation of the Linear Collider Detector On behalf of the Wolfgang Lohmann, DESY.
September, 19 FCAL Worlshop in Tel Aviv W. Lohmann, DESY Physics Requirements Input From Theory Lessons from LEP LumiCal Simulations BeamCal.
Karsten Büßer Instrumentation of the Forward Region of the TESLA Detector International Europhysics Conference on High Energy Physics Aachen, July 19th.
December 4, 2015KILC2012 Daegu Labs involved: Argonne, Vinca Inst, Belgrade, Bukharest IFIN-HH & ISS, CERN, Univ. of Colorado, Cracow AGH-UST, Cracow IFJ-PAN,
First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen.
Novembre 2008LCWS Chicago1 FCAL Report W. Lohmann, DESY Challenges and Design Sensors and Sensor Studies FE ASICS development Data Transfer, Infrastructure.
Octobre MPI Munich VFCAL Report W. Lohmann, DESY Laser alignment system Infrastructure for sensor diagnostics Sensor test facilities FE design Labs.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
Development of Particle Detectors on the Base of Minsk Synthetic Monocrystalline Diamond K.Afanaciev, M.Batouritski, V.Gilewsky, G.Gusakov, I.Emeliantchik,
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
December 7, 2005DESY EUDET in FCAL VINCA, Belgrade Univ. of Colorado, Boulder, BNL, Brookhaven, AGH Univ., INP & Jagiell. Univ. Cracow, JINR, Dubna, NCPHEP,
Electrical features of diamond sensors D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
October DESY PRC Instrumentation of the Very Forward Region of a Linear Collider Detector Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell.
Novembre 2008LCWS Chicago FCAL Report W. Lohmann, DESY Design FE Electronics Sensors and Sensor Tests Plans Labs involved: Argonne, BNL, Vinca Inst, Belgrade,
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
Octobre 2007LAL Orsay Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY.
CNS CVD Diamond S. Michimasa. Properties of diamond Extreme mechanical hardness and extreme high thermal conductivity Broad optical transparency in region.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
Diamond Sensor Tests for the CMS BCM Alexandr Ignatenko FCAL collaboration meeting May 7, 2008.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Very Forward Instrumentation: BeamCal Ch. Grah FCAL Collaboration ILD Workshop, Zeuthen Tuesday 15/01/2008.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Doses and bunch by bunch fluctuations in BeamCal at the ILC Eliza Teodorescu FCAL Collaboration Meeting June 29-30, 2009, DESY-Zeuthen, Germany.
Radiation hardness tests of GaAs and Si sensors at JINR S. M
Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell. Univ. Cracow,
Investigation of diamond sensors for calorimetry
FCPPL, Clermont-Ferrand , 8-10 April, 2014
Wolfgang Lohmann DESY (Zeuthen)
Testbeam Results for GaAs and Radiation-hard Si Sensors
Radiation hard sensors for ILC forward calorimeter
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
Presentation transcript:

17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensors for the ILC forward calorimeter K. Afanaciev, Ch. Grah, A. Ignatenko, W. Lange, W. Lohmann, M. Ohlerich International school-seminar Actual problems of microworld Physics Gomel 2007

17-May-15Actual problems of microworld physics. Gomel 2007 Very Forward Region of the ILC Detector Interaction point The purpose of the instrumentation of the very forward region is: –Hermeticity: increase the coverage to polar angles > 5mrad –Fast beam diagnostics EM calorimeter with sandwich structure: 30 layers of 1 X 0 3.5mm W and 0.3mm sensor Angular coverage from 5 mrad to 28 mrad Moliére radius R M ≈ 1cm Segmentation between 0.5 and 0.8 x R M BeamCal

17-May-15Actual problems of microworld physics. Gomel 2007 The Challenges for BeamCal e+e - pairs from beamstrahlung are deflected into the BeamCal e + e - per BX => E dep  10 – 20 TeV ~ 5 MGy per year strongly dependent on the beam and magnetic field configuration => radiation hard sensors Detect the signature of single high energetic particles on top of the background. => high dynamic range/linearity e-e- e+e+ Creation of beamstrahlung at the ILC ≈ 1 MGy/y ≈ 5 MGy/y For 1 layer, per cell Bethe-Heitler process

17-May-15Actual problems of microworld physics. Gomel 2007 Irradiation facility Energy spectrum of shower particles in BeamCal V.Drugakov 2X 0 Superconducting DArmstadt LINear ACcelerator Technical University of Darmstadt Irradiation up to several MGy using the injector line of the S-DALINAC: 10 ± MeV and beam currents from 2 to 100 nA corresponding to doses about 10 to 600 kGy/h

17-May-15Actual problems of microworld physics. Gomel 2007 Irradiation facility

17-May-15Actual problems of microworld physics. Gomel Investigated materials  Gallium arsenide (GaAs),  Polycristalline CVD Diamond (pCVD)  Silicon (radiaton-hard and common detector-grade for comparison) GaAs SiDiamond Density5.32 g/cm  Pair creation E4.3 eV/pair  Band gap1.42 eV  Electron mobility8500 cm 2 /Vs Hole mobility400 cm 2 /Vs  Dielectric const  Radiation length2.3 cm Ave. E dep /100  m (by 10 MeV e - ) 69.7 keV Ave. pairs/100  m Structurep-n or insul. p-n insul.

17-May-15Actual problems of microworld physics. Gomel 2007 Methodology. Irradiation exit window of beam line collimator (I Coll ) sensor box (I Dia, T Dia, HV) Faraday cup (I FC, T FC ) Irradiation under bias voltage Monitoring of beam and sample currents, sample temperature

17-May-15Actual problems of microworld physics. Gomel 2007 Methodology. CCD Setup typical spectrum of an E6 sensor Sr90 source Preamplifier Sensor box Trigger box & Gate PA discr delay ADC Sr 90 sample Scint. PM1 PM2

17-May-15Actual problems of microworld physics. Gomel 2007 pCVD Diamond Detector pCVD diamonds are an interesting material: –radiation hardness –advantageous properties like: high mobility, low ε R = 5.7, thermal conductivity –availability on wafer scale –Solid-state ionisation chamber (no p- n junction) Samples from two manufacturers were investigated: –Element Six TM (ex-DeBeers) –Fraunhofer Institute for Applied Solid-State Physics – IAF 1 x 1 cm μm thick (typical thickness 300μm) Ti(/Pt)/Au metallization ( courtesy of IAF)

17-May-15Actual problems of microworld physics. Gomel 2007 >5470E6_4p (E6) >5470FAP 5 (IAF) >1300DESY 8 (IAF) >1500E6_B2 (E6) Dose, MGy Thickness, µm Sample 100 nA (E6_4p) 100 nA (FAP5) After absorbing 7MGy: CVD diamonds still operational. CVD Diamond. Irradiation E6_4p

17-May-15Actual problems of microworld physics. Gomel 2007 ~ -80% Signal decreased by  80 % after absorbed dose of about 7 Gy But signal is still visible. Slight increase in current, but still in pA range CVD Diamond. Irradiation results

17-May-15Actual problems of microworld physics. Gomel 2007 CVD Diamond. Irradiation results Signal from sample decreases with time after irradiation further decrease after ‘purging’ trapping levels with UV light Signal increases back after irradiation with small dose - ‘pumping’

17-May-15Actual problems of microworld physics. Gomel 2007 GaAs Detector Supplied by FCAL group at JINR Produced by Siberian Institute of Technology, Tomsk Sample is semi-insulating GaAs doped by Sn (shallow donor) and compensated by Cr (deep acceptor). This is done to compensate electron trapping centers EL2+ and provide i-type conductivity. Sample works as a solid state ionisation chamber Structure provided by metallisation (similar to diamond) 500  m thick detector is divided into 87 5x5 mm pads and mounted on a 0.5mm PCB with fanout Metallisation is V (30 nm) + Au (1  m)

17-May-15Actual problems of microworld physics. Gomel 2007 R pad  500 MOhm I-V and C-V Constant pad capacity no dependence on V => no structure Pad capacity about 12 pF Almost linear IV characteristics => resistor Currents in the order of 0.2  100V

17-May-15Actual problems of microworld physics. Gomel 2007 GaAs. Signal Clear separation of peaks from Sr 90 source S8 pad4 ring 4 S8 pad4 ring 6 Quite homogeneous response over different pads Saturation of about 200V bias Collection efficiency  60%

17-May-15Actual problems of microworld physics. Gomel 2007 GaAs. Irradiation Samples 7&8, pad4, 200V Preliminary Sample 7 Sample 8

17-May-15Actual problems of microworld physics. Gomel 2007 GaAs. Irradiation results Sample 8 pad4 ring6 Results: CCE dropped to about 6% from 60% (by ~ 90%) but signal is visible for absorbed dose of about 1 MGy Dark current increased  2 times (from 0.4 to 1  200V)

17-May-15Actual problems of microworld physics. Gomel 2007 Silicon. Comparison For comparison purposes two silicon detectors were irradiated (detector grade by Micron) Degradation of signal starts at doses  40 kGy At higher doses dark current and noise level increases dramatically (from  10 nA to  A). No clear signal visible Tested this year Radiation hard silicon - no final results yet but general behavior similar => high currents after about 70 kGy

17-May-15Actual problems of microworld physics. Gomel 2007 Conclusion New results - two more diamond samples from E6 irradiated this year Single crystal CVD diamond sample irradiated Radiation-hard silicon sample irradiated  Analysis in progress Further work is planned for CVD diamond and GaAs Possible new material - SiC At the moment CVD diamond and GaAs prove to be sufficiently radiation hard for application in BeamCal Inconsistent results from different diamond samples could be a problem Pumping behavior could be a problem for calorimetry