0 Physical Assessment System Overview. 1 PASS Overview The Physical Assessment Subsystem (PASS) measures the physical condition of HUD properties through.

Slides:



Advertisements
Similar presentations
1 Compliance & Credits: The Tools, The Rules and How They Affect Your HUD Multifamily Housing Project (Real Estate Assessment Center Inspections) Presented.
Advertisements

2/1/ TOP TEN REASONS FOR FAILING A MANAGEMENT AND OCCUPANCY REVIEW Presented by Robert Kriensky GH CAPITAL, LLC.
ONE STOP Real Estate Services G ill G roup
(Individuals with Disabilities Education Improvement Act) and
Emergency Preparedness and Response
Safety Training Safety First. EXITS All exit doors shall be maintained in operable condition. Exit doors shall not be locked, chained, bolted, barred,
Housing Quality Standards & Request for Tenancy Approval
INSPECTIONS WORKSHOP July 18, 2014 CMHA HOUSING CHOICE VOUCHER PROGRAM.
Farmworker Housing Inspections Unit 3: Conducting the Inspection.
“TI” Ohhhh….. (TIO) (No TIO is not a person!) What is it all about?
REAC UPDATE & STATUS OF HCV QA/QC INSPECTIONS. FIRST: REAC - UPCS INSPECTION SOFTWARE CHANGE.
LIHTC Compliance Real Estate Development and Tax Credit Finance 101 Conference July 29, 2014.
 Violations of the following regulations WILL result in a loss of lab points.
Ron DeJuliis, Commissioner of Labor and Industry Rob McGeeney, Program Manager Larry Kreseski, Chief inspector Department of Labor, Licensing, and Regulation.
National Bridge Inspection Standards (NBIS)
0 PHAS Made Simple… In 0 to 2.6 Seconds. 1 Agenda ● Overview of the Public Housing Assessment System (PHAS) and the Integrated Assessment Subsystem (NASS)
Cranes, Hoists and Truck Hoists
NPDES Primer for Executive Officers of Wastewater Facilities Indiana Department of Environmental Management Office of Water Quality Compliance Branch.
Tenant Package Coldwell Banker Pioneer Real Estate Property Management Division Sunnymead Blvd. Moreno Valley, Ca off (951) fax (951)
5/24/20151 Single Family Rental Inspection Program and Ordinance.
Spectrum Enterprises & CHFA Welcome to the Compliance Meeting April 26, 2005.
Tenant Paid Utility Allowances Cindy Ross Contract Management Services
Fire Electrical Back Security
Massachusetts Department of Public Health Bureau of Environmental Health Heating Systems and Enforcement of the Housing Code (In conjunction with the Department.
Real Estate Principles and Practices Chapter 15 Property Management © 2014 OnCourse Learning.
DST H.O.M.E. Home Ownership Maintenance and Education Property Maintenance: Protect Your Property Value.
HFA Institute REAC Uniform Physical Condition Standards January 12, 2015.
0 Resident Assessment Subsystem Overview. 1 Resident Assessment Subsystem (RASS) What is RASS? The RASS survey is a PHA management tool that: Assesses.
October Module 2: Regulations U.S. Environmental Protection Agency (EPA): Established accredited training and certification programs for workers,
CONTROL OF HAZARDOUS ENERGY LOCKOUT/ TAGOUT PROGRAM.
Process Safety Management
CODE ENFORCEMENT. Code Enforcement Code Enforcement Officers work in twelve geographically defined code enforcement areas. In each area the inspectors.
A Basic Overview of the US FDA’s Regulations for Regulatory Compliance
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Building Codes and Interior Design
Spectrum Enterprises & CHFA Welcome to the Compliance Conference November 4, 2005.
MATTHEW MATKOVICH MINE EQUIPMENT COMPLIANCE SPECIALIST QUALITY ASSURANCE & MATERIALS TESTING DIVISION MSHA – APPROVAL & CERTIFICATION CENTER 30CFR, PART.
Software Inspection A basic tool for defect removal A basic tool for defect removal Urgent need for QA and removal can be supported by inspection Urgent.
U.S. Department of Housing and Urban Development 1-3 Objectives Describe the purpose of the Physical Inspection Program and its contribution to achieving.
State Program Review Process Presented by GSFC Compliance Team.
1 DPCP Internal Auditor Basic Training Internal Audit Procedures.
MARCH 9, 2006 Boating Safety and Enforcement Grant Program Regulations Stakeholder Workshop Proposed Conceptual Regulations Department of Boating and Waterways.
PROCEDURES FOR PHYSICAL INSPECTIONS Compliance Audit Investigator (Inspector) will:  Provide random sample list of units to property upon arrival  Explain.
An Introduction to Lodging Establishment Inspections.
Office of Housing Choice Voucher Program Voucher Management System – VMS Version Released October 2011.
Smoke Testing Information
1 AAHRA/HUD 2007 Spring Workshop (Preparing for a REAC Physical Inspection) May 8 - 9, 2007.
Real Estate Principles and Practices Chapter 15 Property Management © 2010 by South-Western, Cengage Learning.
Inspection Review How to respond to Postings Training Document.
Public Libraries Survey Data File Overview. What We’ll Talk About PLS: Public Libraries Survey State level data Public library data (Administrative Entities)
All Outreach Training Cards Requests will be submitted via the NEW ONLINE OUTREACH TRAINER PORTAL
1 Southwestern Affordable Housing Management Association (Special Training: REAC Inspections) February 21, 2008.
Targeted Food Safety Assessments Barb Masters OFW Law September 2015.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
1 Oregon AHMA Bootcamp Friday “How to prepare your property for a REAC inspection!” February 29, 2008.
Ontario Building and Fire Code Overview Presentation for the Downtown Revitalization Committee May 4, 2016 Jack Tosta, Chief Building Official Andrew McPherson,
Preparing For A REAC Inspection Presented by: Patrick Ortiz Lead Housing Programs Analyst New Mexico Mortgage Finance Authority (505)
Online Application Instructional Guide February 28, 2014
DINE & LEARN.
Field Inventory Services-Sanofi Inventory and Audit Training
Emergency Evacuations: Multi-Level Apartments
Project Development and Managing your Build Agenda
U. S. Department of Housing and Urban Development Database Adjustment (DBA) and Technical Reviews (TR) Birmingham Field Office April 18, 2018.
Handgun Licensing for Instructors: Renewal Certification 2017
Building Emergency Evacuation Plan (BEEP) Training for Building Emergency Coordinators and Alternates.
Understanding Common Code Issues
Physical Assessment System Overview
Improving Real Estate Assessment Center (REAC) Inspections:
Building Emergency Evacuation Plan (BEEP) Training for Building Emergency Coordinators and Alternates.
Case Management Safety PROTOCOLS
Presentation transcript:

0 Physical Assessment System Overview

1 PASS Overview The Physical Assessment Subsystem (PASS) measures the physical condition of HUD properties through an inspection process. Objective : To determine whether a PHA’s housing stock is meeting the standard of decent, safe, sanitary, and is in good repair. What regulation established requirements for Physical Inspections? Federal Register 24 CFR, Parts 5 and 200 – Uniform Physical Condition Standards and Physical Inspection Requirements for Certain HUD Housing; Administrative Process for Assessment of Insured and Assisted Properties; Final Rule

2 What is the purpose of a REAC inspection? PHAs perform annual physical inspections in accordance with the Uniform Physical Condition Standards (UPCS). The inspection must include 100% of the property, not just a sampling of the units, and the deficiencies identified must be corrected. The REAC inspection is actually just a quality assurance review of the PHA’s 100% inspection. REAC inspects only a random sampling of the property to determine if the property is being properly maintained. HUD Quality Assurance Reviewers/Inspectors then monitor the certified inspectors’ performance, by reviewing a sample of those inspections.

3 Why follow UPCS? If the PHA is diligently inspecting and maintaining the property, applying the same standards as REAC, the PHA will know what deficiencies the REAC inspector is likely to identify and can correct them prior to the REAC inspection. If the PHA understands and follows the UPCS, the physical condition inspection score determined by REAC for PHAS Indicator 1 should be high. PHAs can contact REAC at to schedule UPCS

4 What are Uniform Physical Condition Standards (UPCS) ? The standards are the foundation of the physical inspection program. They Identify the five (5) inspectable areas and exigent health and safety hazards Standardized definitions for inspectable items Provide uniform, objective protocol for training inspectors to perform inspections of all property types and sizes, at any location

5 Inspection Contractors - UPIC contractors are private inspection firms that have entered into contract with HUD to complete inspections of public and multifamily housing properties. HUD - HUD may assign Quality Assurance inspectors to perform initial inspections or to conduct follow-up inspections. Who orders physical inspections?

6 REAC Inspections are performed by HUD-certified inspectors. Inspectors must successfully complete REAC’s UPCS Inspector training and certification course and maintain their certifications according to strict requirements. A representative of the housing authority must always accompany the inspector throughout the inspection Who performs the inspections?

7 UPCS Inspection software is loaded on a hand-held data collection device (DCD) carried by the inspector during the inspection. On site, the inspector uses the DCD to read the definitions and record deficiencies. A clear definition of each deficiency is contained in the software. All HUD-certified inspectors perform inspections using this method to ensure consistent, objective, factual and comprehensive collection and reporting of inspection data. How is inspection data collected and reported?

8 Uploads inspection results to REAC via the What is the UPCS Inspector’s role in the inspection process? Observes deficiencies Verifies the property profile Classifies deficiencies based on Records each deficiency and the level of Notifies PHA of Exigent Health and the severity of the problem (Level1, Level 2 and Level 3) Safety Hazards before leaving the property severity in the (DCD) while on site Internet

9 PASS Sub Indicators and Weighting Property Site (15%) Building (85%) Building Exterior (15%) Building Systems (20%) Common Areas (15%) Dwelling Units (35%) Health and Safety (across all areas)

10 How Do I Improve My PASS Score? Conduct routine maintenance on all properties and all units Compare previous years’ (1 or more) PASS deficiencies and improve upon them for the current year by using PIH-REAC reports in Secure Systems Pay close attention to Exigent Health and Safety (EHS) (life threatening) deficiencies such as: Inoperable or missing smoke detectors Missing or damaged fire extinguishers Exposed wiring or open panels Anticipate repairing common deficiencies

11 How Does Making Improvements Apply to My PHA? Real World Example: PHA XY123 AreaItemDefect UnitBathroomLavatory sink- damaged/missing UnitKitchenRange/stove- Inoperable UnitDoors Doors damaged- cannot lock properly UnitLightingMissing fixture UnitOutlet/SwitchesBroken cover plates UnitWallsHoles in tile UnitWallsPeeling and needs paint Building ExteriorBlocked entranceMissing accessibility route Building ExteriorRoofsDamaged shingles Systemic Deficiencies for FYE 2002: PHA Code : XY123 Designation : Substandard Physical PHAS IndicatorScore Physical13 Financial28 Management30 Resident9 PHAS Total Score 80 FYE 6/30/02

12 How Does Making Improvements Apply to My PHA? Real World Example: PHA XY123 AreaItemDefect UnitBathroomLavatory sink- damaged/missing UnitKitchenRange/stove- Inoperable UnitDoors Fixed: damaged doors- cannot lock properly UnitLightingMissing fixture UnitOutlet/SwitchesFixed: broken cover plates UnitWallsFixed: holes in tile UnitWallsPeeling and needs paint Building ExteriorBlocked entranceFixed: missing accessibility route Building ExteriorRoofsFixed: damaged shingles Maintenance Corrections from FYE 2002-FYE 2003 are highlighted in yellow below:

13 AreaItemDefect UnitBathroomLavatory sink- damaged/missing UnitKitchenRange/stove- Inoperable UnitLightingMissing fixture UnitWallsPeeling and needs paint How Does Making Improvements Apply to My PHA? Real World Example: PHA XY123 Systemic Deficiencies for FYE 2003 PHAS Total Score92 PHA Code: XY123Designation:High Performer PHAS IndicatorScore Physical25 Financial28 Management30 Resident9 FYE 6/30/03

14 Does Fixing Deficiencies Really Impact My Score? Real World Example on PHA XY123 YES !!! Results: Increased PASS score by 92%, changing PHA’s PASS score from 13 to 25 Overall PHAS score increased by 15% from 80 to 92 Changed designation status from Substandard Physical to High Performer

15 Common Deficiencies Site Alleviate tripping hazards on sidewalks or parking lots Repair damaged fences and gates, including holes or gaps Repair erosion or ruts in ground Tripping Hazard on Sidewalk Over grown shrubs block sidewalk. Damaged Fence Sections of fence missing. Erosion to Sidewalk Dirt surrounding sidewalk washed away.

16 Common Deficiencies Building Exterior: Check doors that are damaged and cannot latch or lock properly Check for damaged sills Make sure all access/ emergency egress exits are not blocked Door Cannot Be Locked Locked door knob. Blocked Access Window boarded up. Damaged Window Broken window pain.

17 Common Deficiencies Building Systems: Repair misaligned ventilation systems Repair leaking water Replace missing interior electrical panel covers Misaligned Ventilation System/Chimney Hot water heater with vent unsecured. Leaking Central Water Pipes leaking fluid on ground. Missing Electrical Panel Cover Electrical box missing cover exposing electrical wires.

18 Common Deficiencies Common Areas: Repair holes or missing tiles Create adequate size trash dispensers and dispose of trash regularly Missing Ceiling Tiles Missing Ceiling Tiles. Roof with exposed Pipes and electrical wires Inadequate Trash Dispenser Inadequate Trash Dispenser. Trash cans that isn’t large enough to hold refuge.

19 Common Deficiencies Units: Ensure that there is adequate hot and cold running water Ensure that there is adequate supply of potable water Alleviate unsanitary facilities that are not in working condition, unusable in privacy, and have inadequate disposal of waste Fix inoperable smoke detectors Each unit must have at least one smoke detector on each level (for example, in a 2 floor unit, there must be 2) If 2 or more smoke detectors are on the same level in visible proximity, at least one of the smoke detectors must function as it should. Remember : Change batteries in smoke detectors often!

20 Common Deficiencies Health and Safety: Repair exposed wires Alleviate blocked exits and entrances Fumigate properties often to eliminate infestation of insects Exposed Wires Wires exposed and not secured to the wall.

21 ~3 months prior to FYE PHA should update PIC data 4-5 months prior to FYE PASS Inspection Inspector leaves EHS notice with property immediately after inspection PHA has 24 hours to alleviate EHS defects PASS Inspection Inspector leaves EHS notice with property immediately after inspection PHA has 24 hours to alleviate EHS defects PASS Inspection time and date sent to PHA via mail 10 days months prior to inspection Inspector confirms time and date via a phone call 2 nd confirmation letter sent to PHA ~4 months prior to FYE PASS Timeline

22 Inspections 4 months prior to inspection and fiscal year end double-check unit count and addresses in PIC Inspection occurs approximately 3 months prior to PHAs FYE PHA representative should accompany the inspector for the inspection Inspector will leave EHS Notice with the property PHA needs to correct EHS life-threatening violations within 24 hours and must report corrections to HUD Field Office within 3 business days Inspection results will be posted on the HUD web through Secure Systems for the PHA to review Deficiencies are recorded at the time of inspection; any deficiencies corrected after the inspection do not effect the score

23 Did You Remember To…. Check for missing, damaged, or expired fire extinguishers? Replace open fuse ports? Ensure there is an interior electrical cover for the A/C unit boxes? Make sure the HVAC hot water heater pressure relief valve discharge tube is no more than 18 inches to the floor? Check roof for non-operable exhaust vents or damaged shingles? Check walls for damage, mold/mildew, holes, or the need for a new coat of paint? Check doors to ensure the seals are not damaged, that there is not dual side key locks, and that interior doors can close properly? Replace damaged stoves or ovens that do not work? Repair leaking pipes and damaged sinks/showers? Ensure that there is proper ventilation to exterior from the laundry rooms? Check date card on fire extinguisher.

24 24 or above – PHA is instructed to make required repairs as part of ongoing maintenance program, not inspected next year unless otherwise troubled (PASS Incentive) 18 to 24 – property is inspected next year but is not troubled based on physical score. 17 or below – PHA is considered troubled based on physical score. What does the score mean to the PHA?

25 No, the system creates the score based on data input However, if an objectively verifiable and material error(s) occurred in the inspection that, if corrected, will result in an improvement in the property's overall score, the PHA can request a Technical Review, or Database Adjustment. Can a PHA challenge its physical inspection score?

26 Building Data - inspection includes the wrong building or a building that is not owned by the property Unit Count - total number of units considered in scoring is incorrect as reported at the time of the inspection Non-Existent Deficiency - deficiency that did not exist at the time of the inspection What material errors justify a Technical Review?

27 PIH-REAC will not consider disagreements over severity of defect, such as deficiencies rated Level 3 that the PHA thinks should be rated Level 1; deficiencies repaired or corrected during or after inspection; or items addressed by the Database Adjustment process What Does NOT Qualify for a Technical Review?

28 inconsistencies between local code and REAC protocol PHA issues - items the PHA does not own, is not responsible for maintaining, and the PHA has notified the proper authorities regarding the deficient structure; adverse conditions beyond the owner's control, such as damage from a natural disaster or third party; and modernization work in progress What material errors justify a Database Adjustment?

29 All property identification – property name, property identification number, Inspection Summary Report number, and specific information relevant to the request All location information for each deficiency presented in the request for review – inspectable area, building number, unit number, etc. What must be included in a request for TR or DBA?

30 Written material to support the request Photographs Videos Address general comments regarding the technical review request and requests for database adjustment in separate correspondence What else?

31 Is there a suggested TR/DBA request format? ppeals_form.pdf

32 Requests must be submitted to REAC within 15 days following REAC's submission of the inspection report to the PHA. What is the timeframe for a PHA to submit such a request?

33 If REAC determines that an objectively verifiable and material error has been documented, REAC may take one or more of the following actions: Conduct a new inspection Correct the physical inspection report Issue a corrected physical condition score Issue a corrected PHAS score What will be the result of a review?

34 PASS Contacts For questions concerning PASS or REAC, please call (toll-free) our Technical Assistance Center (TAC) at: 1 (888) (7:00 a.m. to 8:30 p.m., Eastern Standard Time) For questions concerning UPCS Inspection Training, feel free to the Inspection Training Team at:

35 Other PASS Resources Physical Inspection: Physical inspection Summary Report (Version 2.3): Technical Reviews/Database Adjustment: Overview of the Scoring Process: