Molecular Fluorescence Spectroscopy

Slides:



Advertisements
Similar presentations
Chapter 3 Photophysics. Emission and loss processes: Several of pathways for loss of electronic excitation shown in Fig. as a emission of light as luminescence.
Advertisements

Fluorescence Fluorescent corals.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
Atomic Absorption Spectroscopy (AAS) The Visible Spectra.
1 Molecular Luminescence Spectroscopy Lecture 31.
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Molecular Luminescence Spectrometry
announcements and reminders
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Instrumental Chemistry
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
INTRO TO SPECTROSCOPIC METHODS (Chapter 6 continued ) Quantum-Mechanical Properties Of Light Photoelectric Effect Photoelectric Effect Energy States of.
Chapter 24 Introduction to Spectrochemical Methods
Atomic Absorption Spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
Non-Instrumental Methods
Biochemical instrumental analysis-2
What Are Some Types of Spectroscopy ?
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Spectrochemical Analysis. Electromagnetic Radiation Energy propagated by an electromagnetic field, having both particle and wave nature.
Atomic Absorption Spectroscopy
CHAPTER 15 APPLYING MOLECULAR AND ATOMIC SPECTROSCOPIC METHODS: SHEDDING MORE LIGHT ON THE SUBJECT Introduction to Analytical Chemistry.
Fluorometric determination of riboflavin
CHAPTER 15: MOLECULAR LUMINESCENCE. Chapter LUMINESCENCE TECHNIQUES Emission of light is used to determine certain properties,e e.g.structure and.
Fluorometric determination of riboflavin. Introduction.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Fluorometric Analysis
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/18/2008Chapter 5Raman Spectrometry Chapter 5 Raman Spectrometry.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Lecture 2 INTRODUCTION TO SPECTROMETRIC METHODS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fluorescence Spectroscopy
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Molecular Luminescence Spectroscopy
Introduction to Spectrochemical Methods
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
MOLECULAR FLUORESCENCE SPECTROSCOPY. Fluorescence is a form of photoluminescence; and this later is a type of luminescence that occurs when certain molecules.
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Elemental Analysis using Atomic Absorption and Emission Spectroscopy Bodhisatwa Das.
Molecular Luminescence Spectroscopy
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Fluorometric determination of riboflavin
1 Molecular Luminescence Spectroscopy Lecture 29.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
PHCM561t WS Lecture 4 LUMINESCENCE Quinine Dr. Rasha Hanafi
Introduction to Spectrochemical Methods
The antibonding orbital is designated by an asterisk. Thus, the promotion of an electron from a π-bonding orbital to an antibonding (π *) orbital is indicated.
Chapter 28 Atomic Spectroscopy.
Molecular Fluorescence Spectroscopy
Flame Emission Spectrometry
Ultrafast Spectroscopy
Spectroscopy Chapter 7.
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Molecular Luminescence Spectrometry
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Molecular Fluorescence Spectroscopy Chapter 27 Molecular Fluorescence Spectroscopy Fluorescence is a photoluminescence process in which atoms or molecules are excited by absorption of electromagnetic radiation. The excited species then relax to the ground state, giving up their excess energy as photons. One of the most attractive features of molecular fluorescence is its inherent sensitivity, which is often one to three orders of magnitude better than absorption spectroscopy.

…continued… Another advantage is the large linear concentration range of fluorescence methods, which is significantly greater than those encountered in absorption spectroscopy. Fluorescence methods are, however, much less widely applicable than absorption methods because of the relatively limited number of chemical systems that show appreciable fluorescence.

Principles of Molecular Fluorescence Molecular fluorescence is measured by exciting the sample at the absorption wavelength, also called excitation wavelength, and measuring the emission at a longer wavelength called the emission or fluorescence wavelength. Usually, fluorescence emission is measured at right angles to the incident beam so as to avoid measuring the incident radiation. The short-lived emission that occurs is called fluorescence, whereas luminescence that is much longer lasting is called phosphorescence.

Excitation Spectra and Fluorescence Spectra Because the energy differences between vibrational states is about the same for both ground and excited states, the absorption, or excitation spectrum, and the fluorescence spectrum for a compound often appear as approximate mirror images of one another with overlap occurring near the origin transition (0 vibrational level of E1 to 0 vibrational level of E0). There are many exceptions to this mirror-image rule, particularly when the excited and ground states have different molecular geometries or when different fluorescence bands originate from different parts of the molecule.

Concentration and Fluorescence Intensity The radiant power of fluorescence F is proportional to the radiant power of the excitation beam absorbed: F = K(P0 – P) where, P0 is the radiant power of the beam incident on the sample and P is the radiant power after it traverses a pathlength b of the medium. Constant K depends on the Quantum efficiency. The efficiency of fluoresced to the number absorbed.

At low concentrations where fluorescence is most often employed F = K’P0c where, c is the concentration of the fluorescent species and K’ is a new proportionality constant. F is directly proportional to analyte concentration. Thus, a plot of the fluorescent radiant power versus the concentration of the emitting species should be, and ordinarily is, linear at low concentrations. When c becomes great enough that the absorbance is larger than about 0.05, linearity is lost and F begins to reach a plateau with concentration. This effect is known as a primary absorption inner filter effect. In fact, at high concentrations, fluorescence radiant power can even begin to decrease with increasing concentration.

Molecular Phosphorescence Spectroscopy Phosphorescence is a photoluminescence phenomenon that is quite similar to fluorescence. Understanding the difference between these two phenomena requires and understanding of electron spins and the difference between a singlet state and a triplet state. Ordinary molecules exist in the ground state with their electron spins paired. A molecular electronic state in which all electron spins are paired is said to be a singlet state.

…continued… When one of a pair of electrons in a molecule is excited to a higher-energy level, a singlet or a triplet state can be produced. In the excited singlet state the spin of the promoted electron is still opposite that of the remaining electron. In the triplet state, however, the spins of the two electrons become unpaired and are thus parallel. The excited triplet state is less energetic than the corresponding excited singlet state.

Chemiluminescence Methods Chemiluminescence is produced when a chemical reaction yields an electronically excited molecule, which emits light as it returns to the ground state. Chemiluminescence reactions are encountered in a number of biological systems, where the process is often called bioluminescence. One attractive feature of chemiluminescence for analytical uses, is the very simple instrumentation. Since no external source of radiation is needed for excitation, the instrument may consist of only a reaction vessel and a photomultiplier tube. Generally, no wavelength selection device is needed because the only source of radiant is the chemical reaction.

MOLECULAR SCATTERING METHODS Several additional processes, however, can occur when radiation interacts with matter. One of the most important of these is scattering of electromagnetic radiation. Scattering can be divided into two classes: elastic scattering, in which the scattered radiation is of the same energy as the incident radiation, and inelastic scattering, in which the scattered radiation has higher or lower energy than the incident radiation. Both of these types of phenomena have useful analytical applications.

…continued… Inelastic light-scattering methods have become very important in recent years, particularly those methods based on the Raman effect. Raman spectroscopy involves inelastic scattering of radiation caused by vibrational and rotational transition. The Raman method is complementary to IR spectroscopy and can be used to obtain qualitative, structural and quantitative information about molecular species.

Chapter 28 ATOMIC SPECTROSCOPY Atomic spectroscopy is used for the qualitative and quantitative determination of 70 to 80 elements. Detection limits for many of these lie in the sub-parts-per-million range. The methods can be based on absorption, emission, or fluorescence. Atomic absorption (AA) spectroscopy currently is the most widely used of these techniques.

Atomic Absorption Spectroscopy In AA spectroscopy, as in all atomic spectroscopic methods, the sample must be converted into an atomic vapor by a process known as atomization. In this process, the sample is volatilized and decomposed to produce atoms and perhaps some ions in the gas phase. Several methods are used to atomize samples. The two most important of these for AA spectroscopy are flame and furnace atomization.

Flame Atomic Absorption Spectroscopy The radiation of a line source of the element of interest, typically a hollow cathode lamp, is directed through the flame containing the atomic vapor. Solution samples are usually brought into the flame by means of a sprayer or nebulizer, which produces small sample droplets. The solvent from the droplets quickly vaporizes, and the resulting salt particles vaporize and decompose into atoms, ion and electrons.

…continued… Atoms in the sample will absorb radiation emitted by the same atom in the hollow cathode lamp and thus attenuate the power of the source. Usually a monochromator is used to separate a spectral line of the element of interest from any background radiation from the source or the flame. A photomultiplier tube is typically used to convert the radiant power from the source into a related electrical current.

Furnace Atomic Absorption Spectroscopy Furnace, or electrothermal, AA uses the same instrumental setup as flame atomizer except that a furnace atomizer is substituted for the burner. With furnace AA, discrete amounts of sample, usually microliter volumes, are deposited in the furnace. A multistep heating program is usually applied to desolvate the sample, ash, or char the organic material present and then produce the atomic vapor. Furnace AA gives a transient signal that reaches a peak in a few seconds. Furnace AA is usually one to two orders of magnitude more sensitive than flame AA.