Printed by www.postersession.com Approaching a Universal Pneumatic Nebulizer – the next step Jerry Dulude and Ron Stux (USA), Vesna Dolic and Peter Liddell.

Slides:



Advertisements
Similar presentations
A Modern Approach to Controlling ICP Spray Chamber Temperature Jerry Dulude, Glass Expansion,
Advertisements

Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
A Summary of Studies Comparing Nozzle Types, Application Volumes, and Spray Pressures on Postemergence Weed Control Robert E. Wolf and Dallas E. Peterson,
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
AAS and FES (Ch 10, 7th e, WMDS)
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Printed by Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansion.
Temperature-Related Stability in Plasma Spectrometry Jerry Dulude, Ron Stux, and Vesna Dolic, Glass Expansion,
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Method IntroductionResults Discussion Effects of Plans and Workloads on Academic Performance Mark C. Schroeder University of Nebraska – Lincoln College.
Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.
Air Stripping of Volatiles Sometimes volatile compounds (generally VOC’s ) can be removed from the aqueous phase by stripping the VOC’s with an air flow.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
ATOMIC EMISSION SPECTROMETRY Chap 10 Sections: Sections: 10A 10A 10A-1 10A-1 10A-3 (skim) 10A-3 (skim) 10A-4 10A-4.
Acid Precipitation By Zephyr Dworsky and Lucille Schiffman Fall 2007 By Zephyr Dworsky and Lucille Schiffman Fall 2007.
An Alternative Method for Aerosolized Prostacyclin Administration during Mechanical Ventilation Harborview Medical Center Seattle,Washington Travis J Leistiko.
Classification of Instruments :
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Air Pollution Control – Design Considerations: General Objectives: Background for equipment design To be conversant with equipment manufacturers Understand.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Dust Generator To compare DG (Fig 6) estimates to wind tunnel measured dust emissions, the GRIMM spectrometer output from the tunnel was analyzed against.
in tin pest and pest free Monika Leodolter-Dvorak and Ilse Steffan
Zn x Cd 1-x S thin films were characterized to obtain high quality films deposited by RF magnetron sputtering system. This is the first time report of.
Arsine Detection using Chemcassette ® Technology.
Osmosis Lab By Jake Monroe, Kristen Gray, and Krista Johnson.
Choking Pressure Ratio Guidelines for Small Critical Flow Venturis
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Atomic Emission Spectrometry By: Alexa Kunch
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
A Universal Free-Standing Accessory to Improve ICP Productivity Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559,
Comparison of Competitors’ Evaporative Light Scattering Detectors
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
Effect of Sample Introduction on ICP-MS Detection of Nonmetal Analytes in a Simulated HPLC Matrix Adam E. Dill and Jon W. Carnahan Department of Chemistry.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
A UNIVERSAL PROGRAMMABLE TEMPERATURE SPRAY CHAMBER Jerry Dulude, Glass Expansion,
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Accuracy Based Generation of Thermodynamic Properties for Light Water in RELAP5-3D 2010 IRUG Meeting Cliff Davis.
Quality Assurance How do you know your results are correct? How confident are you?
Printed by Techniques for Increasing Productivity in ICP Spectrometry Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd.,
ATOMIC SPECTROMETRY 1. Flames 2. Electrothermal Atomizers 3. Plasmas.
SPRAY CHAMBER TEMPERATURE: A CRITICAL (YET OFTEN MISSING) PARAMETER IN ICP EXPERIMENTS Jerry Dulude, Ron Stux, and Vesna Dolic, Glass Expansion,
J. A. Mock a, A. I. Bolozdynya a, C. E. Dahl b, T. Shutt a a Department of Physics, Case Western Reserve University, Cleveland, OH USA b Department.
Innovations in ICP Sample Introduction
Chapter 4 Class 4.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Printed by A New Versatile Programmable Temperature Spray Chamber for ICP Jerry Dulude and Ron Stux (USA), Vesna Dolic (Australia),
Brandon Magliocco & Dr. David Schaffer  Economics  Univ. of Wisconsin-Eau Claire Changing Wage Rates Among Men and Women in the U.S. by Age Cohort and.
Scrubbers Colloquium N. Maximova and the class. Puu
A STAND-ALONE DEVICE TO SPEED ICP ANALYSES Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559,
The biogenic role in cloud formation and aerosol chemistry The biogenic role in cloud formation and aerosol chemistry Sanna Ekström Stockholm University,
Atomic Absorption Spectroscopy
1 Chapter 6 Time Delays Time delays occur due to: 1.Fluid flow in a pipe 2.Transport of solid material (e.g., conveyor belt) 3.Chemical analysis -Sampling.
COMPARATIVE STUDY BETWEEN NEAR- INFRARED(NIR) SPECTROMETERS IN THE MEASUREMENT OF SUCROSE CONCENTRATION.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
ENTRAINED FLOW GASIFICATION OF WOOD PYROLYSIS OIL
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
COMPARISON OF EXCITATION CONDITIONS IN
Image quality and Performance Characteristics
Introduction to Atomic Spectroscopy
Time Delays Chapter 6 Time delays occur due to: Fluid flow in a pipe
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Presentation transcript:

printed by Approaching a Universal Pneumatic Nebulizer – the next step Jerry Dulude and Ron Stux (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansion ( Glass Expansion currently designs nebulizers to accommodate spectrometer manufacturers’ recommended gas pressures, gas flows, and sample uptake rates. However, it is desirable to design a single nebulizer that when run under high pressure conditions, generates a finer mist and more of it. In earlier studies (Winter Conference 2006), we compared 60 psi and 30 psi nebulizers for a variety of performance parameters on two different ICP-OES systems. In this study we continue work on the high pressure nebulizer to identify the important characteristics for overall performance improvement. What we want to find out What we are using Figure 1: Sample Intro System We used a Tracey™ Cyclonic spray chamber and SeaSpray™ concentric glass nebulizers (Glass Expansion, Inc., Pocasset, MA, shown in Figure 1), a PerkinElmer Optima 2100 with axial view, and standard conditions except for nebulizer pressure and sample uptake, the parameters under test. TraceyCyclonicSprayChamber With Helix SeaSprayConcentricGlassNebulizer With EzyFit And EzyLok In this study, we show that a nebulizer designed to operate at standard (30 psi) pressure consistently produced lower intensity at lower uptake. While this might be expected, it does stand in stark contrast to the results obtained at 60 psi (Figure 2). We also noted these interesting characteristics: transport efficiency did not appear to depend on nebulizer pressure at a constant (0.7 L/min) argon flow (Table 1). the background improved much more at lower uptake when using 60 psi than when using 30 psi (Figure 3). the lowest absolute background was achieved at 60 psi and 0.4 mL/min (Figure 4). overall, the highest absolute intensity was actually achieved at 60 psi and 0.4 mL/min uptake rate (Figure 2). 8 of 16 tested elements gave best detection limits at 60 psi and 0.4 mL/min. Of the remaining 8 elements, 7 were less than a factor of 2 worse than the best result (Figure 5). What we found in this study What we have already learned In previous work we studied inter-nebulizer variation to demonstrate the degree with which we can discern differences between designs. We also showed that a 60 psi nebulizer designed to be operated at 2 mL/min produces comparable signal (60 to 140%) when operated at 0.4 mL/min (Figure 2). In general, RSDs were better at 60 psi but detection limit results were somewhat mixed. Figure 2: Overall, 60 psi and 0.4 mL/min yielded the highest element intensity DISCUSSION and CONCLUSIONS We were somewhat surprised to find that at constant argon flow, the transport efficiency as measured by weighing the amount of liquid aspirated and the amount collected in the drain did not depend on the argon pressure. This suggests that a nebulizer designed to operate at higher pressure delivers a finer aerosol to the plasma than a nebulizer that is designed to operate at lower pressure. The higher pressure appears to result in a smaller mean droplet size regardless of the uptake rate. As a result, the amount of sample that can be excited in the plasma at 60 psi and 0.4 mL/min is comparable to the amount at 30 psi and 2 mL/min. However, solvent removal efficiency is improved due to the smaller mean droplet size. This also explains why results at 60 psi and 2 mL/min are overall worse than at all other conditions tested. The higher total solvent loading experienced by the plasma as a result of the reduced droplet size leads to greatly elevated backgrounds and higher noise but essentially with no improvement in signal intensity. We believe that this study shows that there are significant benefits to operating at higher nebulizer pressure and lower sample flow. The next step in this series of tests will be to investigate how these performance characteristics affect ICP-MS performance. Figure 3: At 60 psi, lower uptake rate reduced the background more than at 30 psi Figure 4: Overall, 60 psi and 0.4 mL/min yielded the lowest blank intensity Figure 5: Overall, 60 psi and 0.4 mL/min yielded best detection limits Table 1: The transport efficiency appears related only to the sample uptake rate at constant Ar flow