Garry Boorman Principal Advisor, Public Health & Standards

Slides:



Advertisements
Similar presentations
Final Competence Assessment Assessment Documents Assessment strategy (SummitSkills) Assessment methodology (SQA) Assessment guidelines (SQA)
Advertisements

Barhale Procedure for Site Establishment
DENVER ZOO Lion’s Quarters Recycle Cross-connection
Unit 206: Domestic hot water systems
PB - Dialysis Review1 DIALYSIS MACHINES REVIEW OF PLUMBING INSTALLATION REQUIREMENTS.
Unit 205: Cold water systems
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
The New Low Lead Regulations 2014 AWWA Meeting February 26, 2014 LAURA A. TAYLOR (334)
BS9990 : 2015 Updates and/or Changes
October In May 2000, Walkerton’s drinking water system became contaminated with deadly bacteria, primarily Escherichia coli O157:H7.1 Seven people.
Unit 206: Domestic hot water systems
Unit 205: Cold water systems
Supervision of the quality of water intended for human consumption by State Sanitary Inspection bodies Małgorzata Kedzierska Environmental Hygiene Dept.
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
HACCP School Development Project Chapter 11 Quality and Food Safety By Andrea Boyes and Julia Wood Srednja šola Zagorje.
AN INTRODUCTION TO THE FIRE SAFETY ORDER PHIL THOMPSON MIFireE FIRE SAFETY ADVISOR UNIVERSITY OF BRIGHTON.
Health and safety at work
Fire Safety Jonathan Harrison Fire Protection Inspector West Yorkshire Fire & Rescue Authority.
Water Regulations for Allotment Users 1999 onwards.
Whatever the nature of your business, often simple changes in behaviour or processes can save water and reduce your water bill. These water savings can.
Adoption and Enforcement of NSF 372 What Devices Need to Comply Presented by: Julius Ballanco, P.E.
The Health (Drinking Water ) Amendment Act 2007 Grading and Backflow Answers for Water Suppliers Diana Staveley AWT.
1-1. Key Sanitation condition No. 1:  Safe supply for water that contacts food and food contact surfaces;  Safe water supply for production of ice; and.
FOOD SAFETY LEGISLATION Food Safety legislation is designed to protect consumers from illness and harm.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
Construction Health and Safety Management By Dr Simon Smith – licensed under the Creative Commons Attribution – Non- Commercial – Share Alike License.
1 Practical Tips to Emergency Preparedness John Dahlin CHT, CWS-1 Texas ESRD Emergency Coalition.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Support Programs version 2 March 2010 Cleaning and Sanitation
Food Safety Act, food hygiene regulations, HACCP, HASAWA, HSE.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Rainwater Harvesting Health & Safety Considerations Jason Feltham Public Health Inspector Calgary Health Region.
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
Unit 201: Health and safety in building services engineering
Merchant Shipping (Code of Safe Working Practices) Regulations Statutory Instrument 1998 No
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Revised Total Coliform Rule (RTCR) Community Systems Rychel McKenzie Jason Pushard December 2015.
THE IMPORTANCE OF SANITARY SURVEYS by Mary L. Howell, Backflow Management Inc.
Water Recycling. Why? Do you think water should be recycled? Why? How do you think water is recycled?
Building Permit Contractor Round Table 8731 Citizens Drive New Port Richey, Florida Wednesday – July 10, :00 pm to 4:00 pm.
Drinking water 2010 July 2011 Private Water Supplies – What it all means to me? Phil Smart Laura Moss Drinking Water Inspectorate.
Regulations 1999 Water Supply (Water Fittings) With an Introduction to Utility Applications.
Presented by: City of St. Cloud. Water and Sewer Charges Base Fees: Service Availability—Fixed Fee Consumption Fees: Actual Usage—Variable Fee Other Fixed.
Unit 209: Drainage systems
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
The Repairing Standard ELECTRICAL INSTALLATIONS AND APPLIANCES.
Every employer must ensure, as far as is reasonable practicable, the health, safety and welfare of all his employees More specifically, employers must.
 171 Public wells sampled in 2014  Bacteria and Nitrate samples taken  38 wells inspected (Surveyed)  1 nitrite sample taken.
CROSS CONNECTION CONTROL PROGRAM
Water System Infrastructure
Workshop developed by RCAP/AWWA and funded by the USEPA
Advanced Environmental Management (AEM) Training Phase I
CITY OF HARARE EMERGENCY SERVICES
Workshop developed by RCAP/AWWA and funded by the USEPA
Cross Connection Survey Training
Your Public Water System’s Cross-Connection Control Program
Electrical Gas Plumbing Heating & Cooling
Treatment – Chlorine Disinfection
5508BESG Services and Utilities Lecture 2
Emergency Electrical Power Supply for Buildings
Premises Assurance Model
Cisterns and Insulation
Treatment – Process Resilience
Treatment – Ultraviolet (UV)
Treatment – Plant Design
Parker domnick hunter. Safety of Electrical and
Presentation transcript:

Garry Boorman Principal Advisor, Public Health & Standards Maintaining Water Quality ... (1) at temporary events (2) and Private Distribution Networks Garry Boorman Principal Advisor, Public Health & Standards Ian Mitchell Water Regulations & Monitoring Manager

Where to start ...

Where to start ...

Where to start ...

The Water Supply (Water Fittings) Regulations 1999 Replaced Water Byelaws Made 1st April 1999 Laid before parliament 14th April 1999 Enforceable 1st July 1999 Section 74 Water Industry Act 1991 Water Industry Guide – guidance to schedule 2 of the Regulations (requirements for Water Fittings) Regulations are there to provide protection for the water supply from waste; misuse; undue consumption; erroneous measurement and most importantly contamination

Waste ... Water escaping from defective pipes or fittings above or below ground whether seen or not seen.

Misuse ... Water used for any other purpose than that for which it was legally supplied.

Water used in excess of the quantity required for a specific purpose. Undue consumption ... Water used in excess of the quantity required for a specific purpose. (Jan 2001 20% reduction of the amount of water used for flushing new toilets)

Erroneous measurement... By-passing a water meter.

The possible contamination of an internal or external water supply.

Risk Assessment... Backflow by backsiphonage back pressure Decide level of risk (fluid category) check for appropriate backflow device

Backflow Risk – Fluid Categories

Backflow Risk – Fluid Category 1 Fluid Category 1 – Wholesome water, no backflow protection needed.

Backflow Risk – Fluid Category 2 Fluid Category 2 – Aesthetic deterioration Examples: Mixing of hot and cold water supplies Stagnant water in redundant pipe work Ice making machines Domestic water softeners Install - Single check valve fitted.

Backflow Risk – Fluid Category 3 Fluid Category 3 – Slight health risk Examples: Water in domestic central heating systems Domestic wash hand basins / baths Domestic hose union taps Domestic washing & dishwasher machines Install - Double check valve fitted.

Backflow Risk – Fluid Category 4 Fluid Category 4 – Significant health risk Examples: Water in non-domestic central heating systems Printing and Photographic equipment Commercial dishwashing equipment Fire sprinkler systems using anti-freeze Install - Reduced Pressure Zone Valve.

Backflow Risk – Fluid Category 5 Fluid Category 5 – Serious health risk Examples: Grey / Rain water harvesting systems Slaughter house equipment Cattle drinking troughs WC pans, urinals and bidets Install – Storage cistern with AA / AB air gap.

Contamination - Domestic Dead animals in cold water tank

Contamination - Agricultural Live animal in drinking trough (submerged ball valve)

Contamination - Industrial Cross connection causing contamination by industrial / horticultural fluids

Spot the contravention ...

Spot the contravention ...

Spot the contravention ...

Spot the contravention ...

Spot the contravention ...

Spot the contravention ...

Spot the contravention ...

Failure to comply ...

What went wrong?

Approved Materials

Temporary Drinking Water Supplies

Temporary Drinking Water Supplies It is suggested that guidance is made available to organisers of events where a temporary drinking water supply is required so that there is an understanding of the risks associated with supplying drinking water. Reference Document Guidelines for the Provision of Temporary Drinking Water Supplies at Events Water Health Partnership for Wales

Temporary Drinking Water Supplies It is suggested that guidance is made available to organisers of events where a temporary drinking water supply is required so that there is an understanding of the risks associated with supplying drinking water. Failure to properly plan for the provision of a safe source of drinking water can have significant consequences with the organisers additional costs notice and prosecution high risk of an outbreak (campylobacter / E.coli O157) civil action if anyone becomes ill loss of reputation and public reluctance to attend future events poor media coverage

Temporary Drinking Water Supplies Event organisers must contact local authority Environmental Health and local Water Company if a public water supply connection is needed in advance of the event at the earliest opportunity if new connection required at least 12 (20) weeks notice to existing connection at least 4 (8) weeks notice submit plans to show distribution network and infrastructure direction of flow location of pumps, incoming supply, toilet blocks, drinking water points, water for food preparation areas, treatment and sampling points etc

Temporary Drinking Water Supplies Event organisers must ... undertake a risk assessment on water supply arrangements identify potential risks that may cause contamination or an insufficient water supply the measures to be taken to control / prevent these the checks & monitoring procedures to ensure control measures are in place the actions to be taken should the control measures fail

Temporary Drinking Water Supplies Event organisers must ... document their emergency operating plan for dealing with contamination or failure of water supply close the event contingency for emergency water supplies Organisers cannot rely on emergency supplies being provided by the local authority or water company Suggest that the event ‘Water Safety Plan’ is submitted to the local Environmental Health department at least 14 days in advance of the event

Temporary Drinking Water Supplies Commissioning of the water supply storage and disinfection of distribution pipe-work prior to use drained, stored off ground & end capped segregated from fuel oils / contaminants pipe material to be of approved materials (Regulation 31 Water Supply (Water Quality Regulations 2010) laying, preparation & disinfection to be undertaken by appropriately trained and certified personnel check microbiological samples required formal ‘Certificate of Disinfection’ provided to local authority / water company

Temporary Drinking Water Supplies Water provision via tankers or bottled water The following British Standard has been issued to provide guidance on provision of safe drinking water to events where tankers or bottled water are used BS8551:2011 Provision and management of temporary water supplies and distribution networks (not including provisions for statutory emergencies) – Code of Practice Event organisers are strongly recommended to obtain a copy

Temporary Drinking Water Supplies Prevention of Contamination Event organisers must also ensure that the fixtures and fittings connected to the distribution pipe-work do not contaminate the water supply. Any connections made to the public water supply must comply with The Water Supply (Water Fittings) Regulations 1999 Guidance to regulations available via WRAS (http://www.wras.co.uk/Regulations_guide.htm) Connections to public water supply must have backflow protection. Water Company Water Regulations Inspector may visit the site to check for compliance

Temporary Drinking Water Supplies During the Event Environmental Health Officers may undertake inspections and sample during the event

Temporary Drinking Water Supplies Further Recommendations of Good Practice Do operational personnel hold valid National Water Hygiene cards? Distribution pipe-work must not have been used for any other purpose Locate any existing buried sewer, water pipes or electricity cables Ensure that access to any water storage is controlled and restricted to unauthorised people Consider location of fuel / paint stores (bunded?) If event in warm weather consider need to insulate water pipes Label taps suitable for drinking water Monitor chlorine residuals If overland pipes used are these adequately protected from damage Undertake regular inspections of drinking water taps to ensure they remain hygienic

Temporary Drinking Water Supplies

Private Distribution Networks Definitions Distribution System Arrangement of assets (pipes, tanks, pumps) that convey a supply of wholesome water Boundary / Bulk Meter This is the end point of the public network. The point at which a third party takes accountability for conveying a wholesome supply Private Onward Distribution System Term used to describe a privately owned arrangement of assets used to deliver water to other premises. The PODS will be supplied via a Water Undertaker or Combined Licensee. The end of the public supply is defined by a bulk meter or tank

Private Distribution Networks Guidance from DWI – 25th April 2013 http://dwi.defra.gov.uk/stakeholders/guidance-and-codes-of-practice/ 2013 Private Distribution Systems

Private Distribution Networks Guidance from DWI – 25th April 2013

Private Distribution Networks

Private Distribution Networks Examples of issues unlikely to be a Regulation 8 supply caravan sites where there is a single owner of whole site small industrial parks with several different businesses occupying individual units on one premises hotel premises with outbuildings / marquee used for temporary events airports / ports with single owner of whole site university / college / school with single owner of whole site rural estate where all buildings / homes are in the management or ownership of the estate The Water Company is responsible for monitoring and enforcing the Water Fittings Regulations 1999

Where to end ...

Where to end ... Alternative supply pipework (Spring Water) now disconnected Temporary 25mm MDPE overland supply pipe. Installed following failure of private supply source.

Where to end ...

Where to end ...

Where to end ... Cattle trough with type ‘AA’ air gap

Where to end ... 25mm MDPE pipe. Open ended pipe with no backflow protection Animal Faeces

Where to end ... Outside hose union bib taps with no backflow protection

Where to end ... Pre UV sample point – samples ‘passed’ Post UV sample point – samples ‘failed’ UV Disinfection Equipment

Thank You for Listening Contacts For any queries regarding Water Fittings Inspections e-mail ‘water.regulations@severntrent.co.uk’ phone 01332 683711 Or Ian.Mitchell@severntrent.co.uk For any queries regarding temporary supplies or private distribution networks Garry.Boorman@severntrent.co.uk Thank You for Listening