Unit 206: Domestic hot water systems
Unit 206: Domestic hot water systems
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Unit 205: Cold water systems
Filter manifold Holding tank Iron- manganese filter Aeration tank Control unit Pre- filter To storage tanks Backwash overflow SO2 vent Bypass Cutoff valve.
Filling, purging and air removal
Engine Systems and Components
Unit 208: Central heating systems
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Unit 206: Domestic hot water systems
Lesson One.
JET PROPULSION Part 6 Jet Engine Operation Fuel Systems.
STEAM HEATING.
Hydronic Mechanical Controls
PLUMBING Presentation on Central Heating. Forced circulation through loop pipework only Central Heating – Types of systems (Part 1) - One pipe system.
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
Pump is Blue part (right) - timer is black (left side) New Electrical Outlet This Photo shows where the Re-Cir pump is installed on the Output line on.
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
Plan 2 – Dead-end Seal Chamber Optional Jacket
HVAC523 Basic Subsystems.
HYDRONIC HEATING AQUASTATS
Unit 205: Cold water systems
Unit 208: Central heating systems
Hydraulic Kit (pump and tank) Pictures from prototype.
PLUMBING Presentation on Central Heating – Pump Position.
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
Outcome 1 (part 2) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
PISTON ENGINE PROPULSION Chapter 5 Fuel Systems 1933 Alvis Engine 2014 Hyundai Engine Simple Carburettor Fuel System for a Piston Engine.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Chapter 39 Cooling System Fundamentals.
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
Unit 209: Drainage systems
Air condition installation
Plumbing system fundamental and design course
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
HIGH PERFORMANCE PRESSURE SYSTEMS.
Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
Outcome 4 Mechanical central heating controls Unit 208: Central heating systems.
Electrical Gas Plumbing Heating & Cooling
SB Packing Automatic Downpuller Power Unit
Hot water Systems Heaters.
5508BESG Services and Utilities Lecture 2
Hot Water Systems Cylinders and Systems.
Cisterns and Insulation
Common Requirements Taps and Valves.
NEW ARISTON STORAGE BOILERS March, 2009.
Presentation transcript:

Unit 206: Domestic hot water systems Outcome 4 Design features of showers

Showers There are a number of different shower mixer valves available: Bath/shower mixer tap Manual shower mixer valve Thermostatic mixer valve Pressure balancing mixer valve

Showers In most cases, the method of installation is very similar, with the requirement for equal (balanced) pressure and flow rates on both hot and cold feeds. Cistern fed shower Cistern fed with booster pump shower Mains fed hot and cold shower Unbalanced fed shower Instantaneous electric shower

Showers Cistern fed

Showers Cistern fed Requires equal pressure Both the hot and cold are fed from the CWSC Safest valve to use is the thermostatic valve, which will compensate for any temperature fluctuations Minimum head of 1 metre is required from the base of the CWSC to the outlet of the shower rose The feed pipes will need to be in 22mm until just before the mixer valve where they will reduce to 15mm Low pressure system relying on gravity to give the pressure

Showers The thermostatic valve relies on a sensing device that expands and contracts, maintaining the required temperature. Online resource: http://www.aqualisa.co.uk/Our-products/Our-product-videos/

Showers Cistern fed with booster pump

Showers Cistern fed with booster pump Twin impellor booster pump increases pressure for both hot and cold feed Connect to cylinder via an Essex flange, which avoids any ingress of air Connect to cylinder via an angled hot water distribution pipe, which allows air from the cylinder to migrate up to the vent pipe passing the shower feed Twin impellor pump

Showers Cistern fed with booster pump

Showers Cistern fed with booster pump Single impellor booster pump can be used after the mixer valve Boosts the water pressure to the shower head Commonly used on deluge or drench type shower heads Single impellor pump

Showers Positive head Operated by a flow switch under natural flow of water Negative head Operated by a flow switch under a charge

Showers When a pump is pumping water to a level that is above the existing CWSC, it is called (suction) negative head – used to boost cold water. If the water to be pumped is below the existing CWSC, it is positive head. The pump may be pumping from the base of a tank to a higher level, such as an elevated tank, or it may be pulling water from a tank that is below the pump. Negative head pump Positive head pump

Showers A positive head pump is also known as a regenerative pump, as it only paddles the water through. They are slightly noisier pumps and require a natural head or flow of water to activate the pump. The pump is activated by a magnetic flow switch, which moves due to the flow of water. This in turn lines up a reed switch, which makes the electrical connection. If the flow rate is not great enough, the switch is not made. This will mean a negative head pump will have to be used.

Showers A negative head pump is also known as a centrifugal pump, as it sucks in water and forces it out under centrifugal force. They can be used in positive head, negative head and whole house situations. They are quieter and do not require a natural head or flow of water to activate the pump: it is activated by a magnetic flow switch. It moves due to the flow of water created by a charge in the pipework and vessel, then lines up against a reed switch, which makes the electrical connection. A negative head starts at 600mm below the CWSC. The outlet valve of negative head pumps have a non return valve to hold the pressure in the pipework. Online resources: http://www.youtube.com/watch?v=hZOekFFSoWI (wall of death) http://www.youtube.com/watch?v=Zip9ft1PgV0 (water in vessel)

Showers The negative head pumps use centrifugal force which sucks the water into the pump and forces the water to a higher level. The only difference between the pumps is the impellor. Look at the examples in class.

Showers The golden rules CW storage: capacity (don’t pump dry); height of CWSC (positive or negative). Pump position: must be as close to the cylinder as possible. A pump must push – not pull – water. Feeding the pump: a dedicated feed – hot and cold; correct pipe size. Flange connection: Surrey or Essex to stop aeration. Temperature control: a pump can only cope with temps up to 650C max (bypass on whole house). Safety catch on shower blenders set at 380C to go up to 420C.

Showers Mains fed hot and cold

Showers Mains fed hot and cold Fed from an unvented hot water system or a water jacket heater or combination boiler High pressure system No pump is necessary, as both hot and cold are fed from the mains Pressure reducing (regulating) valve is required Large amounts of water can be delivered to the shower at a regulated pressure

Showers Unbalanced feed

Showers Unbalanced feed Showers fed from a combination boiler or instantaneous water heater As the cold water passes through the heater, there is a slight pressure loss A pressure compensating shower valve is required

Showers Instantaneous electric shower

Showers Instantaneous electric shower Fed directly off the incoming mains Instantaneously heated via an electric element 8.5kW to 11kw – the higher the output the better the flow rate Incorporates a low pressure heating element cut off Solenoid operation; water can flow if electrics are on Protected by double pole pull cord isolator Online resource: http://www.aqualisa.co.uk/Our-products/Aqualisa-Videos/How-Electric-works

Showers De-scale shower head regularly; some use them as an open vent A shower requires its own independent feeds If mains fed, a single check valve is required to prevent backflow The air gap between the shower head and water level must be maintained – restraining ring. If no restraining ring, a double check valve is required to prevent backflow Flexible connection on pumps to reduce noise and vibration Online resource: http://www.bristantrainingacademy.co.uk/content/default.aspx