ME 322: Instrumentation Lecture 17

Slides:



Advertisements
Similar presentations
Electrical Thermometers
Advertisements

ME 322: Instrumentation Lecture 15
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
ME 322: Instrumentation Lecture 35 April 18, 2014 Professor Miles Greiner.
ME 322: Instrumentation Lecture 33 April 14, 2014 Professor Miles Greiner.
ME 322: Instrumentation Lecture 24 March 23, 2015 Professor Miles Greiner Lab 9 calculations.
ME 322: Instrumentation Lecture 32 April 10, 2015 Professor Miles Greiner.
ME 322: Instrumentation Lecture 18 March 2, 2015 Professor Miles Greiner TC signal conditioner, Computer data acquisition introduction, Lab 7, myDAQ, LabVIEW.
ME 388 – Applied Instrumentation Laboratory Temperature Measurement Lab.
Thermocouples Most frequently used method to measure temperatures with an electrical output signal.
Thermo Electric Effects & Temperature Measurement
Met 163: Lecture 4 Chapter 4 Thermometry.
Mechanical Measurement and Instrumentation MECN 4600
ME 322: Instrumentation Lecture 39
Overview of Temperature Measurement ME 115 Figures are from “Practical Guidelines for Temperature Measurement” unless otherwise notedwww.omega.com.
ME 322: Instrumentation Lecture 19
ME 322: Instrumentation Lecture 20 March 6, 2015 Professor Miles Greiner myDAQ A/D converter, temperature uncertainty, First-order, centered numerical.
Met 163: Lecture 4 Chapter 4 Thermometry. Thermoelectric Sensors The junction of two dissimilar metals forms a thermocouple. When the two junctions are.
ME 322: Instrumentation Lecture 26 March 27, 2015 Professor Miles Greiner Radiation temperature errors, Lab 9.1 Sensors and instructions.
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Temperature Controls Andrew Blackwell For a copy of this presentation please me at This presentation mainly.
Temperature Measurement using sensors and signal conditioning
Engineering 80 – Spring 2015 Temperature Measurements
Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor:
Thermocouples Most frequently used method to measure temperatures with an electrical output signal.
Thermocouples Most frequently used method to measure temperatures with an electrical output signal.
Module 3 Eng. Asma Abu Baker. Introduction One of the most important uses of instruments or measuring devices is in the field of process control. If you.
Temperature Sensors.
Engineering Mechanical Laboratory Term Lab 9 (b): Thermocouple Lab 9(a): Viscosity.
Temperature 1.  Temperature is defined as the degree of hotness or coldness of a body measured on a definite scale  Temperature is the driving force.
ME 322: Instrumentation Lecture 5 January 28, 2015 Professor Miles Greiner Lab 3, transmitter characteristics, least-squares, standard error of the estimate.
1  Voltmeter Circuit –Extremely high resistance –Always connected across or in parallel with the points in a circuit at which the voltage is to be measured.
ME 322: Instrumentation Lecture 25 March 25, 2014 Professor Miles Greiner Thermocouple response to sinusoidally varying temperature, radiation and conduction.
ME 322: Instrumentation Lecture 16 February 25, 2015 Professor Miles Greiner Lab 6 calculations (Excel demo)
ME 322: Instrumentation Lecture 23 March 13, 2015 Professor Miles Greiner Transient TC response, Modeling, Expected and observed behaviors, Lab 9, Plot.
Sensors and Electricity. What is a Sensor? A sensor is a device that: A sensor is a device that: 1) Measures a physical quantity 2) Converts this measurement.
Engineering Mechanical Laboratory Term 1/2009 Lab 9 (b): Thermocouple Lab 9 (a): Viscosity Nopdanai Ajavakom.
Introduction to Temperature Sensors
Met 163: Lecture 4 Chapter 4 Thermometry This week TUE: thermometry lecture THU: how to obtain data from RAWS, RAWS data analysis using MATLAB software,
PSAA Curriculum Unit Physical Science Systems. Problem Area Energy and Power Systems.
ME 322: Instrumentation Lecture 11 February 11, 2015 Professor Miles Greiner Pitot probe operation, non-linear transfer function, fluid density, uncertainty,
MECH 322 Instrumentation Lab 7 Computer Data Acquisition System for Steady Thermocouple Signals Performed: March 6, 2007 Group 0 Miles Greiner Lab Instructors:
ME 322: Instrumentation Lecture 13: Exam Review February 18, 2015 Professor Miles Greiner.
ME 322: Instrumentation Lecture 38 April 24, 2015 Professor Miles Greiner Integral Control.
ME 322: Instrumentation Lecture 4 January 26, 2015 Professor Miles Greiner Had extra time, could add a few more slides next year Lab Guidelines and grading,
Temperature Measure of internal energy of substance Four common scales Celsius (C) Kelvin (k) Fahrenheit (F) Rankine (R)
ME 322: Instrumentation Lecture 10 February 9, Professor Miles Greiner Lab 5 Summary and Calculations.
The Measurement of Temperature
ME 322: Instrumentation Lecture 8 February 3, 2016 Professor Miles Greiner Lab 4, Propagation of Uncertainty, Maximum and likely, Power Product, Examples.
Thermo-energy audit Services for thermo-energy audit Temperature measurement.
ME 322: Instrumentation Lecture 36 April 20, 2015 Professor Miles Greiner Proportional Control.
Thermocouples Thomas Johann Seebeck, 1821, discovered that a circuit of two different metals with junctions at different temperatures produced an electromotive.
Engineering 80 – Spring 2016 Temperature Measurements 1 SOURCE: 3_standardbody__to-226_straightlead.jpg SOURCE:
Consider following problem Want to measure temperature range of: -15 o C < T 1 < 35 o C. Reference junction, T 2, = 0 o C. Output must be in range of -5Volts.
Thermocouples Most frequently used method to measure temperatures with an electrical output signal.
ME 322: Instrumentation Lecture 35
MECH 373 Instrumentation and Measurements
Measurements & Instrumentation – Module 3
The Measurement of Temperature
Sigma Institute of Engineering
Vidhyadeep institute of management and technology Electrical : B
ME 322: Instrumentation Lecture 25
ME 322: Instrumentation Lecture 23
ME 322: Instrumentation Lecture 16
ME 322: Instrumentation Lecture 7
TEMPERATURE SENSOR.
ME 311 Mechanical Measurements Instrumentation II 5/6/03
Overview of Temperature Measurement ME 115
Prepared by Dr. Mohamed Ahmed Awad
Instrumentation and Control: ME- 441 Department of Mechanical Engineering UMT 1.
Presentation transcript:

ME 322: Instrumentation Lecture 17 February 27, 2015 Professor Miles Greiner Temperature measurements, thermocouple circuits, thermocouple demo

Announcements/Reminders HW 6 due now HW 7 due Friday Lab 6 next week Only 4 wind tunnels (we are constructing a 5th) Watch your WebCampus to find when your group is scheduled to attend lab. Bring Excel from HW 6 and use it to process the data you acquire. This will help check the data as you take it and allow you to complete the data acquisition phase of the lab in one hour

Midterm I Scores Average 75, St. Dev 18 In 2014 it was 74 and 18 (very similar) Solutions posted outside PE 213 I will only consider revising scores before Wednesday, March 4, 2015

Phenomena used to Measure Temperatures Liquid density change (in glass thermometer) Metal Deformation (Coil, bimetallic strips) Gas Pressure Wire resistance Problem All devices act line fins and affect the temperature of the locations that they are measuring

Thermocouples Employ the Seebeck Effect 𝐴 𝐵 Employ the Seebeck Effect When two dissimilar metals (A & B) are in contact, a small electrical potential (voltage) is produced that depends on the junction temperature. Probes can consist of two wires and be inexpensive Rugged shielded probes can be expensive

Demonstration (three junctions) Iron 2 Put into Ice VOUT 1 Fe/Con down 2 Cu/Fe little change 3 Con/Cu up + VOUT 1 3 - Constantan Ni/Cu For demo use type-J thermocouple pair (Iron/Constant) connected to a copper (Cu) digital voltmeter Output is in the 10’s of microvolts 10mV = 0.01 mV = 0.00001 V VOUT depends on all three junction temperatures The sensitivity of VOUT to temperature is not the same for all the junctions.

TT = Terminal Block Temp ≈ uniform Thermocouple Circuit Metal C TT = Terminal Block Temp ≈ uniform + TS TS VOUT HE WOUT - TR TR Four junctions, including reference Let VCA(T) be voltage decrease going from C to A at junction temperature T VCA(T) = VC(T) - VA(T) 𝑉 𝑜𝑢𝑡 = 𝑉 + − 𝑉 − =VCA( 𝑇 𝑇 )+VAB( 𝑇 𝑆 )+ VBA( 𝑇 𝑅 )+ VAC( 𝑇 𝑇 ) How are these voltage related? 𝑉 𝐶𝐴 𝑇 𝑇 = ? 𝑉 𝐴𝐶 𝑇 𝑇 𝑉 𝐵𝐴 𝑇 𝑅 = ? 𝑉 𝐴𝐵 𝑇 𝑅 𝑉 𝑜𝑢𝑡 = 𝑉 𝐴𝐵 𝑇 𝑆 − 𝑉 𝐴𝐵 𝑇 𝑅 (transfer function, 𝑇 𝑆 desired, 𝑇 𝑅 undesired) If terminal block is isothermal, then 𝑉 𝑜𝑢𝑡 not dependent on Temperature TT or metal C How to find 𝑉 𝐴𝐵 𝑇 ? 2nd Law of Thermodynamics (heat engine) If TS = TR, then VOUT = ?

Standardization Industry uses standard wire material pairs (page 276) The composition of the two wires must be well-controlled and sufficiently-different to give predictable (small uncertainty) and useful (sensitive) voltages Different wire pairs have different operating ranges and sensitivities, S = dVTC/dT = d(Reading)/d(Measurand)

How to find VAB(T) T Material Science Calculations, or Calibration: VOUT T TR= 0°C Material Science Calculations, or Calibration: Put reference junction is pure water/Ice Slurry, TR = 0°C Measure VOUT for a range of T See Page 277 for results

Different sensitivities (slopes) Standard wire uncertainty: Not really linear Different sensitivities (slopes) Standard wire uncertainty: Larger of 2.2°C or 0.7% of measurement

Circuits without a Reference Junction TT TS TT ? 𝑉 𝑜𝑢𝑡 = 𝑉 𝐶𝐴 𝑇 𝑇 + 𝑉 𝐴𝐵 𝑇 𝑆 + 𝑉 𝐵𝐶 𝑇 𝑇 = ? Problem, we have data for wire pair AB, but not CA or CB “Thought” experiment: If TS = TT , then by 2nd law 𝑉 𝑜𝑢𝑡 = 𝑉 𝐶𝐴 𝑇 𝑇 + 𝑉 𝐴𝐵 𝑇 𝑇 + 𝑉 𝐵𝐶 𝑇 𝑇 = ? So 𝑉 𝐶𝐴 𝑇 𝑇 + 𝑉 𝐵𝐶 𝑇 𝑇 = −𝑉 𝐴𝐵 𝑇 𝑇 (effect of C cancels out) 𝑉 𝑜𝑢𝑡 = 𝑉 𝐴𝐵 𝑇 𝑆 − 𝑉 𝐴𝐵 𝑇 𝑇 Don’t need VCA(T) or VBC(T) data to find this transfer function! ? ? ?

Problem 9.22 A type E thermocouple is placed in an oven and connected to a computer data-acquisition system. The junction box temperature is independently measured to be 30°C. The thermocouple voltage is found to be 37.0 mV. What is the temperature of the oven?

Thermocouple Signal Conditioner Reading VSC [V] Measurand, T [°C] 400 10 ? Out of range Transfer Function 𝑆 𝑆𝐶 = 𝜕 𝑉 𝑆𝐶 𝜕𝑇 TS (°C) VSC (V) 400 10 In lab use Omega DRE–TC-J; for Type J (Iron/Constantan) thermocouples http://wolfweb.unr.edu/homepage/greiner/teaching/MECH322Instrumentation/Labs/Lab%2007%20Boiling%20Water%20Temperature/Lab7%20Index.htm Wiring: Iron (white insulation) goes to +Tc; Constantan (red stripe) goes to (-Tc) Transfer Function: 𝑉 𝑆𝐶 =10𝑉 𝑇 𝑆 400℃ =0.0025 𝑉 ℃ 𝑇 𝑆 = 𝑆 𝑆𝐶 = 𝜕 𝑉 𝑆𝐶 𝜕𝑇 = 10𝑉 400°𝐶 =0.025 𝑉 °𝐶 ; 𝑆 𝑇𝐶 = 𝜕 𝑉 𝑇𝐶 𝜕𝑇 = 0.00005 𝑉 °𝐶 ; G𝑎𝑖𝑛= 𝑆 𝑆𝐶 𝑆 𝑇𝐶 = 500 Inverted transfer function: TS = (40°C/V)*VSC Conditioner Provides Reference Junction Compensation Amplification Low Pass Filter (RF noise rejection) Linearization Galvanic Isolation (avoid ground loops even in water)