What do we need? René Flükiger Dept. Phys. Cond. Matter (DPMC) & TE-MSC-SCD CERN WAMSDO 2011 Workshop (CERN), 14.11.111.

Slides:



Advertisements
Similar presentations
PWI Modelling Meeting – EFDA C. J. OrtizCulham, Sept. 7 th - 8 th, /8 Defect formation and evolution in W under irradiation Christophe J. Ortiz Laboratorio.
Advertisements

18 th International Conference on Plasma Surface Interaction in Controlled Fusion Toledo, Spain, May 26 – 30, Deuterium trapping in tungsten damaged.
Investigation of Proton Irradiation-Induced Creep of Ultrafine Grain Graphite Anne A. Campbell & Gary S. Was University of Michigan Research Supported.
Neutron Irradiation Measurement for Superconducting Magnet Materials at Low Temperature Tatsushi NAKAMOTO KEK.
Review of WAMSDO 2011workshop: Superconductors in LHC Upgrade (HiLumi LHC) René Flükiger, Gijs DeRijk CERN TE- SC-SCD REMM'12, Fermilab,
William Cunningham Properties of SiC radiation detectors W. Cunningham a, J. Melone a, V.Kazukauskas b,c P. Roy a, F. Doherty a, M. Glaser d, J.Vaitkus.
11 September 2007 FP7-IA HFM JRA proposal G. de Rijk (CERN)1 FP7-IA HFM JRA proposal   Outline Motivation General description Proposed Work Packages.
We distinguish two hadronization mechanisms:  Fragmentation Fragmentation builds on the idea of a single quark in the vacuum, it doesn’t consider many.
University of Cambridge Stéphane Forsik 5 th June 2006 Neural network: A set of four case studies.
Particle Interactions
A payload to test in space Superconductive Magnetic Shielding technology R. Battiston Perugia University June 2010.
ENEN Collimator Materials for LHC Luminosity Upgrade: Status of Irradiation Studies at BNL Collimation Upgrade Specification Meeting 21/06/2013 N. Mariani.
Development of Superconducting Magnets for Particle Accelerators and Detectors in High Energy Physics Takakazu Shintomi and Akira Yamamoto On behalf of.
This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC , the State of Michigan.
1 A.I.Ryazanov, E.V.Semenov and A.Ferrari DPA calculations in irradiated graphite collimator materials under 7 TeV and 450 GeV proton beams ,
1Ruđer Bošković Institute, Zagreb, Croatia
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Radiation damage effects on RRR WAMSDO 2013, 15./16.1., CERN René Flükiger CERN WAMSDO 2013, 15./ , CERN1.
Mechanical properties of insulators for Accelerator Magnets WAMSDO 14/11/2011 George Ellwood 1.
Measurement and modeling of hydrogenic retention in molybdenum with the DIONISOS experiment G.M. Wright University of Wisconsin-Madison, FOM – Institute.
NEEP 541 Radiation Interactions Fall 2003 Jake Blanchard.
Possible HTS wire implementation Amalia Ballarino Care HHH Working Meeting LHC beam-beam effects and beam-beam interaction CERN, 28 th August 2008.
Overview of ‘classical’ or ‘standardized’ DPA calculation stemming from the reactor world. Colin English NNL.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Design of the Photon Collimators for the ILC Positron Helical Undulator Adriana Bungau The University of Manchester Positron Source Meeting, July 2008.
Design of electrostatic septum for slow extraction from J-PARC main ring 2005, March 2nd ICFA septa workshop 2005 Acc. Lab., KEK M. Tomizawa, Y. Arakaki,
Exploring Parameter Space for Radiation Effects in SC Magnets FermilabAccelerator Physics Center Nikolai Mokhov Fermilab With contributions from A. Konobeyev,
Simulating fusion neutron damage using protons in ODS steels Jack Haley.
Russian Research Center” Kurchatov Institute” Theoretical Modeling of Track Formation in Materials under Heavy Ion Irradiation Alexander Ryazanov “Basic.
Irradiation of insulators for EuCARD Workshop on Accelerator Magnet, Superconductor, Design and Optimization CERN Maciej Chorowski, Jaroslaw.
K. McDonald Target Studies Meeting Feb 8, Limits for Radiation Damage to and Thermal Loads on Magnet Conductors (Preliminary Survey: Radiation Damage.
Radiation damage calculation in PHITS
Effect of Starting Materials and Present State of Cold Densified MgB 2 wires for Industrial Scale-up M.S.A. Hossain, C. Senatore, R. Flükiger, M. Tomsic,
Analysis of electron mobility dependence on electron and neutron irradiation in silicon J.V.VAITKUS, A.MEKYS, V.RUMBAUSKAS, J.STORASTA, Institute of Applied.
Optimization of Field Error Tolerances for Triplet Quadrupoles of the HL-LHC Lattice V3.01 Option 4444 Yuri Nosochkov Y. Cai, M-H. Wang (SLAC) S. Fartoukh,
Radiation Resistance G. Ambrosio Fermilab 2nd Joint HiLumi LHC/LARP Annual Meeting November, 2012 Frascati Work supported by the US LHC Accelerator.
J.Vaitkus. RD50 Workshop, Liverool, May, 2011 Deep level system Gaussian approximation according the extrinsic photoconductivity in irradiated Si.
INTERSTITIAL DEFECT REACTIONS IN P-TYPE SILICON IRRADIATED AT DIFFERENT TEMPERATURES L.F. Makarenko*, S.B. Lastovski**, L.I. Murin**, M. Moll*** * Belarusian.
1 Russian Research Center” Kurchatov Institute” Alexander Ryazanov Charge State Effects of Radiation Damage on Microstructure Evolution in Dielectric Materials.
FLUKA Meeting Milan Jul 2010 Work in the frame of the LHC Phase II Upgrade Previous work was dedicated to the study of the.
Production Readiness Review of L0/L1 sensors for DØ Run IIb R. Demina, August, 2003 Irradiation studies of L1 sensors for DØ 2b Regina Demina University.
BNL Irradiation Facility Use Collimator Materials for LHC Luminosity Upgrade.
Stress review - CERN, Review on stress sensitivity Part I R. Flükiger B. Seeber Group of Applied Physics (GAP) University of Geneva 1.
J.Vaitkus et al. PC spectra. CERN RD50 Workshop, Ljubljana, "Analysis of deep level system transformation by photoionization spectroscopy"
Mike Struik / LHC-CRI INSTRUMENTATION FEEDTHROUGH SYSTEM FOR LHC MACHINE ARC QUADRUPOLE MAGNETS. 123rd LHC Vacuum Design Meeting 19 April 1999.
7 th RD50 Workshop CERN Geneva November Università degli Studi Università degli Studi di Perugia di Perugia 1 Radiation Hardness of Minimum.
Fluence and isochronal anneal dependent variations of recombination and DLTS characteristics in neutron and proton irradiated MCz, FZ and epi-Si structures.
J.Vaitkus, L.Makarenko et all. RD50, CERN, 2012 The free carrier transport properties in proton and neutron irradiated Si(Ge) (and comparison with Si)
EuCARD WP 7 – High Field Magnets Task 7.2 Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 Status report EuCARD HFM collaboration.
Applied Superconductivity at UNIGE Overview of the activities Départment de Physique de la Matière Condensée & Départment de Physique Appliquée Université.
Proton and neutron irradiation facilities in the CERN-PS East Hall Maurice Glaser and Michael Moll CERN- PH-DT2 - Geneva - Switzerland 6 th LHC Radiation.
EuCARD WP 7 – High Field Magnets EuCARD WP 7 – High Field Magnets Aim and goals Mini Workshop of Accelerators Radiation Mini Workshop of Accelerators Radiation.
RESMM Workshops FermilabAD / Accelerator Physics Center Nikolai Mokhov Fermilab RESMM’15 East Lansing, MI May 10-14, 2015.
National Research Centre ”Kurchatov Institute”
Characterization of He implanted Eurofer97
Radiation Effects on Nb3Sn, copper and inorganic insulation
Heating and radiological
Scientific investigations performed at RRC KI for
National Research Center” Kurchatov Institute”
Energy deposition studies on magnets. Aim. First applications
Update on Annealing Studies for Severely Irradiated Silicon Detectors
Kickoff meeting - HTS Tl-based coatings for FCC beam screens
Expected radiation effects in HL-LHC and FCC
Radiation Damage to Mu2e Apparatus
Results from the first diode irradiation and status of bonding tests
Russian Research Center “ Kurchatov Institute”
Design of Nb3Sn IR quadrupoles with apertures larger than 120 mm
The superconducting solenoids for the Super Charm-Tau Factory detector
High resolution transmission electron microscopy (HRTEM) investigations of defect clusters produced in silicon by electron and neutron irradiations Leona.
Design of Nb3Sn IR quadrupoles with apertures larger than 120 mm
Presentation transcript:

What do we need? René Flükiger Dept. Phys. Cond. Matter (DPMC) & TE-MSC-SCD CERN WAMSDO 2011 Workshop (CERN),

2 Starting point of the present considerations: Calculations of F. Cerutti (CERN), 2010 (newer calculations in his presentation, today) In the following, analysis will be restricted on Nb 3 Sn (quadrupoles) MgB 2 for current leads: talk of M. Putti BI-2212: not yet developed at an industrial level.

WAMSDO 2011 Workshop (CERN), Neutron fluence in the inner winding of Quadrupoles (LHC Upgrade) « TRIPLET » Q1Q2aQ2bQ Distance from Collision Point (m) F. Cerutti + A.Mereghetti (CERN), 2010 Peak: > 5 x neutrons/cm 2 Fluence in 10 « years » (200 days)

WAMSDO 2011 Workshop (CERN), MeV Neutron spectrum in the inner coil of Q2a at peak location Neutrons

WAMSDO 2011 Workshop (CERN), MeV 100MeV 1GeV Proton spectrum in the inner coil of Q2a at peak location Protons

WAMSDO 2011 Workshop (CERN),  1 GeV Pions + Pions - Pion spectrum in the inner coil of Q2a

WAMSDO 2011 Workshop (CERN), Aperture 200mm 130mm130 mm Photons % Neutrons % 4.04% Protons %0.13% Pions % 0.19% Pions % 0.25% Electrons % Positrons % Peak Fluence, LHC Upgrade (5 x cm -2 s -1 ) Radiation spectrum at Q2a: 35m from Collision Point 0.57% Protons + Pions(+) + Pions(-) ≈ 14 % Neutrons

Question: How do the magnets (quadrupoles) behave after 10 years of operation? Study to be carried out for each high energy source: * the superconductorT c, J c, H c2 * the stabilizing Cu  (T) * the insulatormechanical properties, electrostatic charges,… * the magnetcombined effects, quench behavior, volume changes (expansion of Nb 3 Sn, Cu and insulator ) WAMSDO 2011 Workshop (CERN),

Keep in mind: * all high energy sources act simultaneously * there is no experience on a combined effect of several high energy sources * subsequent irradiations with different sources should be carried out on selected samples * calculations must be carried out to study combined irradiations (taking into account the small values of dpa, this may be possible WAMSDO 2011 Workshop (CERN),

10 Neutrons : Strong source of damage for superconductors Protons: From known data, even stronger effect (charge) Pions: Nothing is known yet. Effects expected to be comparable to those of protons (charges +/-) Electrons: Very little is known. Much smaller effects expected (in contrast to insulators). More data needed Photons: Nothing is known. Smaller effects expected. Data needed Known effects of radiation on superconductors

WAMSDO 2011 Workshop (CERN), What should be analyzed about irradiation of the superconductor? Damage Mechanism (atomic ordering); Comparison with heavy ion irradiation Effect of various energy sources Number of displacement per atoms Summation of single irradiations (small dpa numbers) Irradiation at 4.2K and 300K Volume expansion of Nb 3 Sn; Effect of repeated warming up and cycling on irradiated superconductors Thermal stabilization: Recovery behavior of Cu? Mechanical properties of the superconductor after irradiation

WAMSDO 2011 Workshop (CERN), Mechanisms of irradiation damage Due to limited data, results from heavy ion irradiation are also taken into account

High energy particle (n, p, p, heavy ions, fission fragments Frenkel defects, Vacancies, Interstitials Focused Collision Replacement Sequences Collision events (1 st, 2 nd, 3rd,…) Lattice expansionDisordering Antisite Defects Mean Static Displacements Depleted zones  a > 0  S > 0  ( ) 1/2 ≠ 0 Amorphous or transformed Increasing volume fraction Vacancy Clusters Vacancy mechanism Low Fluence High Fluence Building up of Internal strain (strain misfits) 13 R. Flükiger, 1986 WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN), Effect of neutron irradiation on T c

WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN),

A.R. Sweedler, D.G. Schweizer, G.W. Webb, Phys. Rev. Lett. 33 (1974) 168 T c of Nb 3 Sn after 1 MeV neutron irradiation WAMSDO 2011 Workshop (CERN),

Recovery of Nb 3 Sn films after irradiation at T < 30K with 25 MeV O-ions (B. Besslein, 1976) < 1K WAMSDO 2011 Workshop (CERN),

Fluence (x n/cm 2 ) T ann (K) E > 0.1 MeV Neutron irradiation of a multifilamentary Nb 3 Sn wire, followed by an anneal of 5 min. at T ann. B.S. Brown, T.H. Blewitt, T.L. Scott, D.G. Wozniak,, J. Appl. Phys.49(1978) Recovery Effects after warming up WAMSDO 2011 Workshop (CERN), %

WAMSDO 2011 Workshop (CERN), Volume expansion of irradiated Nb 3 Sn

Analogy between neutron and heavy ion irradiation Scaling law between various sources not yet investigated WAMSDO 2011 Workshop (CERN), x n/cm 2  V ≈ 1% At 1 x n/cm 2, volume expansion of Nb 3 Sn is ≈ 1%: * internal stresses? * effects on J c ?

a  t (x n/cm 2 ) WAMSDO 2011 Workshop (CERN), A. Sweedler, 1978 Schneider, 1982 Volume expansion after irradiation

Suppression of martensitic transformation in Nb 3 Sn films irradiated with 20 MeV 32 S ions at < 30 K (2 x cm -2 ) (C. Nölscher, 1984) Hall constant WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN), Irradiation of binary and ternary alloyed Nb 3 Sn

Fluence (n/cm 2 ) H.W. Weber et al., 1986, Adv. Cryo. Eng., 32, 853 J c /J co 8T 4T E > 0.1 MeV (Nb- 1.5wt.%Ti) 3 Sn wires Binary Nb 3 Sn wires 25 E > 0.1 MeV ~ 3 x x T 10T 8T 4T WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN), Binary Nb 3 Sn Bronze route 10’000 filaments Binary Nb 3 Sn Bronze route 19 filaments F. Weiss, R. Flükiger, W. Maurer, P.A. Hahn, M.W. Guinan, IEEE Trans. Magn., MAG 23(1987)976 Neutron irradiation E = 14 MeV I c (max) varies for different wire configurations

WAMSDO 2011 Workshop (CERN), I c (max) are different for different neutron sources: When comparing the effect of irradiation for different neutron sources e.g. 1 MeV and 14 MeV, the fluences have to be considered carefully, and the appropriate corrections have to be made

WAMSDO 2011 Workshop (CERN), Binary Nb 3 Sn wire (19 filaments) Ti alloyed Nb 3 Sn wire (19 filaments) E = 14 MeV This effect does not depend on the neutron source, but on the Nb 3 Sn wire configuration

29 Behavior of J c under stress after irradiation WAMSDO 2011 Workshop (CERN),

Stress – strain curves before and after irradiation Bronze Route multifilamentary wire T irr = 350 K 4.2 K fluence Recovery after annealing at 450 and 700 °C T. Okada, M. Fukumoto, K. Katagiri, K. Saito, H. Kodaka, H. Yoshida, IEEE Trans. Magn., MAG-23(1987)972 Hardening with higher fluence 30WAMSDO 2011 Workshop (CERN),

Effect of uniaxial tensile strain after irradiation I c (A) I c (A) Strain (%) Strain (%) Strain (%) T. Okada, M.Fukumoto, K.Katagiri,K.Saito, H.Kodaka, H.Yoshida, IEEE Trans.Magn. MAG-23(1987)972 Bronze Route Multifilamentar y Nb 3 Sn wire Before Irradiation After Irradiation  m = 0.2%  m = 0.4% 31WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN), The effect of proton irradiation on Nb 3 Sn (thin films)

WAMSDO 2011 Workshop (CERN), Fluence (x p/cm 2 ) 0.6 x p/cm 2 I c /I co Maximum of I c after proton irradiation Binary Nb 3 Sn J c max for neutrons 8 x n/cm 2 4T – 30 GeV, Snead et al.

WAMSDO 2011 Workshop (CERN), Binary Nb 3 Sn wires (and films): Maximum of I c : neutrons: 8 x n/cm 2 protons: 6 x p/cm 2 Still necessary to know behavior after proton irradiation, in spite of 3% fluence with respect to neutrons ! Ternary Nb 3 Sn wires: Maximum of I c : neutrons: 2 x n/cm 2 protons: ? Even more necessary: behavior under pion irradiation. Total damage of protons + pions becomes comparable to that caused by neutrons

WAMSDO 2011 Workshop (CERN), Planned operations at CERN C. Scheuerlein T. Spira PhD, will start January 2012 R. Flükiger L. Bottura A. Ballarino G. De Rijk Calculations: Collaboration with F. Cerutti (CERN) F. Broggi, Milano)

Planned operations at CERN - 1 Material: Nb 3 Sn with additives (Internal Sn, PIT) Ti Ta (activation!) Neutron irradiation, 1 MeV, Collaboration with Atominstitut Vienna Neutron irradiation of Nb 3 Sn wires at 1 MeV and 14 MeV has already been performed 20 years ago However, new investigation on high J c wires with precisely determined neutron fluence at 300K (see the presentation of Harald Weber) WAMSDO 2011 Workshop (CERN),

1: Confirm the systematic difference between binary and ternary alloyed Nb 3 Sn wires after neutron irradiation 2: Establish the maximum of J c vs. fluence; find out at which fluence the values of J c and H c2 2: Comparison between resistive and inductive J c measurements on Internal Sn and PIT wires T. Baumgartner et al., MT22 (H. Weber’s talk) Advantage: once the scaling is established, J c can be determined on 3 mm wire pieces by magnetization. This result will be used for measuring J c in proton irradiated wires Goal of the collaboration with Atominstitut Vienna: WAMSDO 2011 Workshop (CERN),

Planned operations at CERN - 2 Proton Irradiation at various energies Material: Nb 3 Sn Internal Sn and PIT wires, with Ta and Ti additives Collaborations with: * Kurchatov Institute (Russia)35 MeV10 18 p/cm 2 * Université catholique, 65 MeV10 17 p/cm 2 Louvain la Neuve, Belgique * CERN: IRRAD124 GeV10 17 p/cm 2 ISOLDE1.4 GeV10 18 p/cm 2 First magnetization measurements of wires after decay: after mid 2012 WAMSDO 2011 Workshop (CERN),

Proton irradiations at Kurchatov Institute: Program Duration : 24 months Proton energy: 35 MeV Temperature: 300K (+ heating due to proton impact) Maximum fluence:1x p/cm 2 Tasks on irradiated wires:J c by magnetization measurements*)**) Electrical resistivity vs. T T c TEM Lattice parameters Tasks on irradiated bulks: Long range atomic order parameter*) Calculations: dpa calculations for proton irradiation *) Measurements will be performed at CERN **) Transport J c on proton irradiated wires: will be done later WAMSDO 2011 Workshop (CERN),

WAMSDO 2011 Workshop (CERN), Conclusions (superconductors) We are still at the beginning of our investigations: *Need for proton and pion irradiations of Nb 3 Sn wires *Are binary or ternary alloyed Nb 3 Sn wires better? *How has the volume expansion (1% at n/cm 2 ) to be taken into account? *Irradiations at 4.2K still necessary (very small number, for comparison) *Warming up and cooling cycles needed for reliability tests *New devices for testing at 15 T needed *New devices for mechanical testing needed *Calculations needed: dpa, but also combined irradiations