STRAY CURRENT CORROSION

Slides:



Advertisements
Similar presentations
Columbia Gas of Ohio/Kentucky Tim Jenkins Corrosion Front Line Leader
Advertisements

Mitigation of AC Induced Voltage On Buried Metallic Pipelines
MAGNETIC EFFECTS OF ELECTRIC CURRENT
Stray currents corrosion of underground steel pipelines
Chapter 12 Transformers. Chapter 12 Transformers.
Stray and Telluric Current Correction
Corrosion and Cathodic Protection
 Magnetic field lines: lines of force representing the magnetic field around a magnet  Magnetic pole: the end of the magnet which produces magnetic.
SMAW Equipment (Shielded Metal Arc Welding- commonly called “stick welding”, or “arc welding”)
ASSIGNMENT TEACHER Smt. K.VASUMATHY GROUP MEMBERS:- MANSI DWIVEDI (ET 4 TH SEM) ARTI DWIVEDI (ET 4 TH SEM) DIKSHA CHANDRAKAR (ET 4 TH SEM) MAMTA CHOUDHARY.
Electricity, Sound and Light
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
Induced Voltages And Inductance Chapter 20 Hans Christian Oersted.
Magnetism and Electromagnetic Induction
AC Mitigation Overview
Chapter 31 Faraday’s Law.
Electric Power Distribution, Generators and Motors
Cathodic Protection of Tower Anchors
GENERATING AND DETECTING OF ULTRASOUND
Electric Power Distribution, Generators and Motors.
Electricity and magnetism
Corrosion Protection Jacek Banaś.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Corrosion Control A PHMSA Perspective Pipeline Safety Trust Conference.
CHAPTER - 13 MAGNETIC EFFECTS OF ELECTRIC CURRENT
Control of DC and AC Interference on Pipelines
Inductors. Inductance Electrons in motion create electromagnetic fields – Recall from previous section that electrons in motion also create an electrostatic.
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
CORROSION:- TYPES EFFECTS & PREVENTION PRESENTED BY: GAUTAM AHUJA
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Electromagnetic Induction Working independently in 1831, Michael Faraday in Britain and Joseph Henry in the United States both found that moving a loop.
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
Copyright © 2009 Pearson Education, Inc. Back EMF, Counter Torque & Eddy Currents Example: Back EMF in a Motor. The armature windings of a dc motor have.
Direct current (dc) generators Split ring (commutator) does the job of reversing polarity every half cycle.
Chapter 31 Faraday’s Law.
Electricity & Magnetism Static, Currents, & Electro Magnets Motors & Generators.
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Chapter 29 Electromagnetic Induction and Faraday’s Law
Chapter 20 Induced Voltages and Inductance. Faraday’s Experiment – Set Up A current can be produced by a changing magnetic field First shown in an experiment.
Generator and Transformer. Moving Conductor If a straight conductor is moved in a path perpendicular to a magnetic field, a current is induced in the.
Generator and Transformer. Moving Conductor If a straight conductor is moved in a path perpendicular to a magnetic field, a current is induced in the.
Electricity. Electric Charge Rules: –More protons than electrons: + charge –More electrons than protons: - charge –Like charges repel; opposite charges.
Cell & Batteries. CELLS AND BATTERIES CELLS AND BATTERIES Understand the general features of cells and batteries Understand the general features of cells.
Raymond F. Mignogna, MS, PE Metallurgical Engineer
My Chapter 20 Lecture Outline.
Electricity Vocabulary Negatively charged ion – Gains electrons Positively charged ion – Loses electrons.
Chapter 22 Electromagnetic Induction. When a coil of wire is in a magnetic field, the magnetic flux Ф is the strength of the field B multiplied by the.
Magnetism. All of us are familiar with magnets. In a magnet we have magnetic poles – the north and the south pole. All of us are familiar with magnets.
1.If a magnet is moved into a coil of wire a current is induced in the wire. 2.If the magnet is moved out of the coil the direction of the current is reversed.
Chapter 31 Faraday’s Law.
Introduction to Power Supplies
Electricity in the Home CBE. Wiring a plug DC and AC DC stands for “Direct Current” – the current only flows in one direction: AC stands for “Alternating.
Mutual Inductance As in a transformer, changing the current in the primary coil causes an induced voltage in the secondary coil i.e. mutual induction has.
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Electromagnetic Induction 4 Quiz 1.Who discovered electromagnetic induction? a)Michael Faraday b)Thomas Edison c)Joseph Henry 2.A transformer.
Electrical Energy Generation and Transmission Physical Science Chapter 21 Section 3.
Unit 8 Lecture Chapter 21. Magnetic Force The amount of magnetic force depends on distance Closer magnets are, the stronger the force On a magnet, the.
Electromagnetic Induction
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
CORROSION MITIGATION OF A PIPELINE
CHAPTER 3 Cathodic Protection How It Works.
4 ways to boost electromagnet power Circuit diode Inverse direct
Criteria for Cathodic Protection
BY Presenter Name: G.V,Reddy DESIGNATION: Sr. General Manager
PRESENTATION ON AC & DC INTERFERENCE
Power transmission Energy is lost in transmission lines
CHAPTER 6 Stray Current Interference.
Field Testing for Shorted Casings
Fundamentals Course Basic Corrosion
Presentation transcript:

STRAY CURRENT CORROSION Stray currents are currents flowing in the electrolyte from external sources. Any metallic structure, for example a pipe line, buried in soil represents a low resistance current path and is therefore fundamentally vulnerable to the effects of stray currents

Stray current tends to enter a buried structure in a certain location and leave it in another. It is where the current leaves the structure that severe corrosion expected. Overprotection might also occur at a location where the high current density of stray current enter a structure. There are a number of source of undesirable stray currents, including foreign cathodic protection installations, dc transit systems such as electrified railways, subway systems, and streetcars, welding operations, and electrical power transmission systems.

Stray currents, can be classified into three categories: 1. - Direct currents 2. - Alternating currents 3. - Telluric currents

DIRECT STRAY CURRENT CORROSION Direct stray currents come from foreign cathodic protection systems, transit systems, and dc high voltage transmission line. Direct stray current can cause : 1. Anodic interference 2. Cathodic interference 3. Combined interference

Anodic Interference It is found in relatively close proximity to a buried anode. At location close to anode the pipeline will pick up current. This current will be discharged at a distance farther away from the anode.

In the current pickup region, the potential of the pipeline will shift in the negative region. It receives a boost of cathodic protection current locally. This local current boost will not necessarily be beneficial, because a state of overprotection could be created. Excess of alkaline species generated can be harmful to aluminum and lead alloys.

Cathodic Interference Cathodic interference is produced in relatively close proximity to a polarized cathode. Current will flow away from the structure in region in close proximity to the cathode. The potential will shift in the positive direction where the current leaves this structure, and this area presents the highest corrosion damage risk. Current will flow onto the structurew over a large area at farther distance from the cathode.

Combined Anodic and Cathodic Interference Current pickup occurs close to an anode, and current discharge occurs close to a cathodically polarized structure. The degree of damage of the combined stray current effects is greater than in the case of anodic or cathodic interference acting alone. The damage in both the current pickup (overprotection effects) and discharge regions (corrosion) will be greater.

Controlling Stray Current Corrosion In implementing countermeasures against stray current effects, the nature of stray currents has to be considered. For mitigating dc interference, the following fundamental steps can be taken: Removal of the stray current source or reduction in its output current. Use of electrical bonding Cathodic shielding Use of sacrificial anodes Application of coatings to current pickup areas

Use of a drainage bond

Cathodic shielding

Use of sacrificial anodes

Stray Current Associated with DC Transit System Stray current due to electrified transit system might be illustrated from the following figure:

The rail has been grounded, however remote from the substation, due to the voltage drop in rail itself, the rail will tend to be less negative relative to earth and stray current flows onto the pipeline. Close to the substation, the rails are highly negative relative to earth, and stray current will tend to leave the pipeline and induce corrosion damage. The presence of stray currents can thus can thus usually be identified when fluctuating pipe-to-soil potential are recorded with time.

ALTERNATING STRAY CURRENT FROM POWERLINES There are two dominant mechanisms by which stray currents associated with powerlines transmssion can be produced in buried pipelines: 1. Electromagnetic induction 2. Transmission line faults

A voltage is induced in a buried structure under the influence of the alternating electromagnetic field surrounding the overhead transmission line. The effect is similar to the coupling in a transformer, with the overhead transmission line acting as primary transformer coil and the buried structure acting as the secondary coil. The magnitude of the induced voltage depends of the factors such as the separation distance from the power line, the relative position of the structure to the powerlines, the proximity to other buried structures, and the coating quality.

Such induced voltages can be hazardous to anyone who comes in contact with the pipeline or its accessories. The second mechanism is one of resistive coupling, whereby AC currents are directly transmitted to earth during transmission line faults. Usually such faults are of very short duration, but due to the high currents involved, subtantial physical damage to coated structures is possible.

TELLURIC EFFECT The stray current are induced by transient geomagnetic activity. The potential and current distribution of buried structures can be influenced by such disturbances in the earth’s magnetic fields. Such effects, often assumed to be greatest significance in closer proximity to the poles, has been observed to be more intense during periods of intensified sun spot activities. In general, harmful influences on structure are of limited duration and do not remain highly localized to specific current pickup and discharge areas. Major corrosion problems as a direct result of telluric effects are therefore relative rare.