Shakes and Quakes A Structural Engineer's View

Slides:



Advertisements
Similar presentations
Seismology and Earthquake Engineering :Introduction Lecture 3
Advertisements

Residential Foundations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture He who has not first laid his foundations may be able with.
Landmarks and Relative Location
Yahya Kurama, Assistant Professor Meghan Myers, Undergraduate Student Richard Christenson, Graduate Student Andrew Jackson Middle School February 28,
Main Functions of Buildings 4 Provide a safe and comfortable environment for work and rest. (Protect us from wind, rain and the wild animals) 4 Two types.
ENGR 166 – Foundations in Engineering Structural Engineering Module Dynamics of Structures.
Earthquake Basics Section 2. +What causes earthquakes? +How do earthquake forces enter buildings? +How does the building respond? +What building elements.
CEA UNIT 3 TERMS & DEFINITIONS. BEAM A structural member, usually horizontal, that carries a load that is applied transverse to its length.
Earthquakes in San Francisco, California - Structural Engineering Solutions -
Engineering Structures 101 Structural Engineering: From the Beginning Professor Martin Fahey Head, School of Civil & Resource Engineering Room A1.10 (
MUSE 11B Buildings in Earthquakes Why do buildings do the things they do?
USC Civil & Environmental Engineering St. Andreas Fault Right-Lateral Strike-Slip Faults Location: Carrizo Plain area, San Luis Obispo County, California.
Faults & Topography. What’s a Fault? A fault is a break in the rock that makes up the Earth’s crust. The surfaces on either side of the break move past.
Earthquake Engineering Research Institute University of Notre Dame.
ECIV 724 A Dynamics of Structures Instructor: Dr. Dimitris C. Rizos 300 Main St. Dept. of Civil and Environmental Engineering (803)
What Will a Large Earthquake be Like? Tom Heaton Caltech.
SCEC Annual Meeting - ITR 09/17/ Izmit Earthquake August 17, 3:02am, 1999 Mw 7.4 Mw earthquake: >18,000 fatalities >300,000 homeless.
FlatIron Building New York Times Building 1903.
1 Yahya C. Kurama, Professor Civil and Environmental Engineering and Earth Sciences University of Notre Dame Introduction to Engineering Program University.
1 Yahya Gino Kurama, Associate Professor Civil Engineering and Geological Sciences University of Notre Dame Introduction to Engineering Program University.
for Earthquake Resistance
Types of Plate Boundaries in California The Great California ShakeOut.
Japanese earthquake resistance technology
Yahya Kurama, Assistant Professor Richard Christenson, Graduate Student Tracy Correa, Graduate Student Gang Mei, Graduate Student Brian Morgen, Graduate.
The San Francisco Earthquake of 1906 By Mrs. Cheney.
Earthquakes.
Villanova University Dept. of Civil & Environmental Engineering CEE 8414 – Structural Dynamics Northridge Earthquake 1 Northridge Earthquake - Concrete.
Construction Technology Applying Technology Period 1.
Seismic Design of Concrete Structure.
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
1 Natural Disasters Earthquakes & Their Damages. 2 San Francisco M = 7.8; 3,000 killed.
STRUCTURE By Simonnett Rosenberg Gabriela Di Lorenzo.
Frames and Walls Lateral Stability
TOPICS COVERED Building Configuration Response of Concrete Buildings
GEO 6950 Reviews in Earth Science, Fall 2011 Topic 2 Tectonics of Western North America 11. San Andreas Fault System Carrie Welker and Alex Turner.
Before you jump into this slide show, you should view the Presentation on EarthquakeSeismology See notes for link.
“Earthquakes” I. Causes of Earthquakes: A. Why do earthquakes take place? 1. Rocks act the same way rubber bands work. 2. Applying stress to a rock will.
General Science. What is an Earthquake?  Earthquakes are one of the most powerful natural forces  Shaking and vibration at the surface of the earth.
Izmet, Turkey Earthquake By Molly Sumpter. Outline ► tectonic setting of Turkey, North Anatolian Fault ► August 17, 1999 event ► outcomes, what was learned.
California Earthquakes Through an historical perspective.
Landmarks to Know. Pyramids of Giza Giza, Egypt Empire State Building New York, New York.
Earthquake Damage Unit. Where would you be the safest in an earthquake? Open level field away from buildings Movement of the ground rarely causes deaths.
LESSONS FROM PAST NOTABLE EARTHQUAKES. Part IV Walter Hays, Global Alliance for Disaster Reduction, Vienna, Virginia, USA.
Bolu A zone with seismic risk. Geological risk in Bolu ● There are about inhabitants in Bolu. ● On August 17 th 1999 an earthquake in Turkey killed.
Brad Oliver – Structural Option Advisor – Professor Memari.
Earthquakes Around the World U.S. Geological Survey Walter D. Mooney Senior Research Geophysicist USGS, Menlo Park, CA.
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
Quaking, Shaking, Earth All about Earthquakes By: Mrs. Baker Edited by Mrs. Fowler 2015.
Roll No. 14, 23, 25, 29, 43. EARTHQUAKE An earthquake (also known as a quake, tremor or temblor) is the result of a sudden release of energy in the Earth.
Earthquake Hazards Owain Thomas Credit: U.S. Geological Survey.
Rocks Move along Faults
Earthquake Hazards pg Earthquake An earthquake is the motion or trembling of the ground produced by sudden displacement of rock in the Earth's crust.
Unit 29 – Construction in Civil Engineering
Base Isolation. Conventional Construction Practice assumes Fixed Base Structures The Dynamic Characteristics of Fixed Base Structures are determined by.
2005 PS3 Summer Institute Buildings in Earthquakes Why do buildings do the things they do?
K’NEX STRUCTURE COMPETITION
Review of Indian Seismic Codes
II. Earthquakes Small magnitude earthquakes are much more common than larger magnitude earthquakes.
Chapter 19 - Earthquakes Forces within Earth.
Structural Engineering: Skyscrapers
Bridges A bridge is like an aerial road.
STRUCTURAL ENGINEERING Session 04
English for Civil Engineers
Key Question: How are buildings designed (aseismically) to withstand earthquakes? Key Words: Aseismic Design Retrofitting Land-use planning.
Chapter 19 - Earthquakes Forces within Earth.
“Earthquakes” I. Causes of Earthquakes:
Vocabulary/Definitions buckling: When a column fails by bending at some point in the height of the column, usually towards the midpoint caused by.
Masonry Bearing Walls.
Unit 3 Day 6.
Presentation transcript:

Shakes and Quakes A Structural Engineer's View Yahya Gino Kurama, Associate Professor Civil Engineering and Geological Sciences University of Notre Dame Good afternoon. My presentation is on the seismic behavior of unbonded post-tensioned precast concrete walls which I have been studying as a part of my Ph.D. work at Lehigh University. Before I begin talking about my research, I would like to give you a brief description of unbonded post-tensioned precast concrete walls and an introduction to their seismic behavior. Introduction to Engineering Program University of Notre Dame July 16, 2004

STRUCTURES Structure: “any assemblage of materials that is intended to sustain loads” Nearly every plant and animal, and nearly all works of man have to sustain forces without breaking, so practically everything is a structure of one type or another.

Civil Structures are BIG! Dams Tunnels Civil Structures are BIG! Buildings Domes Bridges

Man fears Time, yet Time fears the Pyramids How Old is Structural Engineering? Man fears Time, yet Time fears the Pyramids Arab proverb Great Pyramids Sphinx

Structural Loads SOMETIMES FAILING! Gravity loads (self weight, people, furniture, etc.) Earth and water pressure Dynamic wind load effects Dynamic occupant effects Earthquakes Structures respond to these dynamic loads, moving, swaying, and …. “Non-emulative” Traditionally, precast structures in seismic regions have been designed to emulate the behavior of monolithic cast-in-place concrete structures, largely because of the limited knowledge about their seismic behavior. However, in recent years the precast concrete industry has emphasized structures which do not imitate monolithic cast-in-place concrete structures because of their economy, construction simplicity, and desirable seismic characteristics such as self-centering capability and the ability to undergo “large” nonlinear displacements with little damage. SOMETIMES FAILING!

Wind Excited Structures

Human Excited Structures

Human Excited Structures

Human Excited Structures

Earthquake Excited Structures

Reinforced concrete frame Steel frame Reinforced concrete wall BUILDING STRUCTURES Masonry Reinforced concrete frame Steel frame Reinforced concrete wall “Non-emulative” Traditionally, precast structures in seismic regions have been designed to emulate the behavior of monolithic cast-in-place concrete structures, largely because of the limited knowledge about their seismic behavior. However, in recent years the precast concrete industry has emphasized structures which do not imitate monolithic cast-in-place concrete structures because of their economy, construction simplicity, and desirable seismic characteristics such as self-centering capability and the ability to undergo “large” nonlinear displacements with little damage.

Can You Recognize These Masonry Structures? St. Paul’s Cathedral, London Pantheon, Rome Hagia Sophia, Istanbul San Pietro Citta’ del Vaticano, Rome Santa Maria del Fiore, Florence

What are Masonry Structures Made of? BRICKS, STONES, and MORTAR

And ... Under an Earthquake ... THEY BREAK!!

And They Break!

Where are These Frame Structures? Transamerica Building San Francisco Sears Tower Chicago John Hancock Building Chicago Marina City Chicago Empire State Building New York City

How Do We Build Them?

Resting After a Hard Day's Work

AUGUST 17, 1999 IZMIT EARTHQUAKE (M 7.4)

SEISMIC ACTIVITY IN THE REGION

San Andreas Fault California

RIGHT-LATERAL STRIKE-SLIP FAULT (> 1400 km) The North Anatolian Fault E W

HORIZONTAL SLIP ALONG THE NAF 2 meters (6.6 feet)

HORIZONTAL SLIP ALONG THE NAF

HORIZONTAL SLIP ALONG THE NAF

VERTICAL SLIP ALONG THE NAF 1.7 meters (5.6 feet)

VERTICAL SLIP ALONG THE NAF

REINFORCED CONCRETE BUILDINGS

REINFORCED CONCRETE BUILDINGS

WHICH FLOOR WOULD YOU RATHER LIVE IN?

SOFT/WEAK STORY COLLAPSE

REINFORCED CONCRETE BUILDINGS

REINFORCED CONCRETE BUILDINGS

HYGOKEN-NAMBU, JAPAN, 1994

CHI-CHI, TAIWAN, 1999

NORTHRIDGE, U.S., 1994

NORTHRIDGE, U.S., 1994

Poor detailing, poor materials, poor workmanship MAIN PROBLEMS Poor detailing, poor materials, poor workmanship Stiff and heavy structures Limited capacity to deform laterally “Non-emulative” Traditionally, precast structures in seismic regions have been designed to emulate the behavior of monolithic cast-in-place concrete structures, largely because of the limited knowledge about their seismic behavior. However, in recent years the precast concrete industry has emphasized structures which do not imitate monolithic cast-in-place concrete structures because of their economy, construction simplicity, and desirable seismic characteristics such as self-centering capability and the ability to undergo “large” nonlinear displacements with little damage.

SEISMIC ISOLATION

SEISMIC ISOLATION USING LEAD-RUBBER BEARINGS

LEAD-RUBBER BEARING

USC UNIVERSITY HOSPITAL - WITH ISOLATION The Base-Isolated USC Hospital Building The USC Hospital is an 8-story building with many isolators that act like shock absorbers to damp out strong ground shaking. The building contains 149 isolators that support a steel superstructure on continuous concrete spread footings. Diagonally braced perimeter frames, supported by 68 isolators, were designed to carry the lateral loads and the internal columns that carry the vertical load were supported by 81 isolators. The building, within 15 kilometers of the Newport-Inglewood fault zone, was designed for a maximum relative isolator displacement of 26 centimeters, and to meet the seismic standards of the 1988 and 1994 Uniform Building Code (UBC). The motions recorded at the top of the isolators and at the roof were smaller than those recorded below the isolators and in the free field (a ground site away from and free of the influences of the building). These findings provide clear evidence that the isolators were effective in dissipating the vibrational energy traveling from the free field to the building. In general, the shapes of the spectra of recorded components of motions are well enveloped by the building code spectrum, except for some high frequency (>1 hertz) bands for which the code spectrum is exceeded. Accelerations at various levels of the building, and the amplitude spectra and relative displacements of the isolators confirm excellent performance throughout the building. Drift ratios (displacements within a building story at the top relative to the base) reached only 10% of allowable values explaining why there was little damage to the structure or its contents. However, the ground motions at this site were only moderately strong. USGS studies showed that displacements near the seismogenic fault of the Northridge quake would exceed the designed displacement range for the isolators. Therefore, the performance of the isolators could be a problem at the USC Hospital should shaking be stronger than that of the Northridge earthquake. Base-isolated buildings are a relatively recent addition to U.S. earthquake-resistant design strategies. In base-isolated structures, the building is insulated from strong ground motion by energy-absorbing systems between the building and its foundation. Such buildings are still uncommon because the design concept had not been tested by severe earthquakes prior to the Northridge event. Lessons Learned The structural responses derived from strong-motion recordings in buildings actually shaken by earthquakes can be compared to the theoretical responses that were used in designing the structures. These comparisons may verify the calculations and the stability of the design, or they may point to problems that need to be corrected in future construction. Performance of the USC Hospital building showed that design improvements are needed for the type of base-isolation system used in the building. Prior to the Northridge earthquake, structural engineers believed that modern buildings constructed with specially designed steel frames could resist very intense ground motions with only limited structural damage. However, during the earthquake, the steel framing of more than 100 such structures experienced fractures. The fractures initiated at the welded connections between the beams and columns of the frames. These fractures were initially attributed to poor quality workmanship in the welding of the connections. However, a review of historical test data and tests performed immediately following the earthquake demonstrated that connections with standard quality workmanship were vulnerable to the fractures. Many of the damaged buildings were at sites that experienced ground motions approximating those adopted by the building code as a basis for design. Consequently, the adequacy of the building code provisions was immediately questioned, and the International Conference of Building Officials (ICBO) adopted an emergency code change in October 1994. The ICBO action prompted the creation of a joint venture among the Structural Engineers Association of California (SEAOC), the Applied Technology Council (ATC), and the California Universities for Research in Earthquake Engineering (CUREE). The joint venture, simply named SAC, initiated a program to resolve the issues related to the steel-frame damage, and to publish advisories and guidelines. SAC published several interim documents during 1995 to assist engineers and building officials in design and inspection activities while reliable new building codes were being developed for steel-frame buildings. This effort was funded by the Federal Emergency Management Agency (FEMA).

USC UNIVERSITY HOSPITAL - WITH ISOLATION

OLIVE VIEW HOSPITAL - WITHOUT ISOLATION Failures due to discontinuity of vertical elements of the lateral load resisting system have been among the most notable and spectacular. One common form of this type of discontinuity occurs when shear walls that are present in upper floors are discontinued in the lower floors. The result is frequently formation of a soft first story that concentrates damage. A well-known example (shown below) is the Olive View Hospital, which nearly collapsed due to excessive deformation in the first two stories during the 1972 San Fernando earthquake and subsequently had to be demolished (6,18). The Olive View Hospital Building The OVH building was designed in 1976 to withstand increased levels of seismic forces based on the disastrous fate of its predecessor. The structural system for resisting lateral forces is a mixed design of concrete and steel shear walls. The foundation consists of spread footings and concrete slab-on-grade for the ground floor. The ground floor and second floor are typically built of concrete shear walls 25 centimeters thick that extend along several column lines. At the third level, the plan of the building changes to a cross shape, making a 4-story tower with steel shear walls surrounding the perimeter. USGS engineers examined the building’s performance by using data from both the Northridge and Whittier Narrows earthquakes for comparisons. The building was designed for two levels of performance. The first level, 0.52g, represented accelerations at which the building would not be badly damaged. The second level, 0.69g, represented accelerations at which the building would survive, perhaps with major damage but without catastrophic failure. Data from sensors in the OVH building show that the building escaped the impact of long-period (>1 second) pulses generated by the Northridge quake. The OVH records indicated that very large peak accelerations at the ground level (0.91g) and the roof level (2.31g) were accommodated by the building without structural damage. Analyses of the data indicate that the structure was in resonance at frequencies between 2.5 and 3.3 hertz. These frequencies are also within the site-response frequencies of 2-3 hertz, calculated from examining the geological materials upon which the structure was built. The effective structural frequencies derived from the Northridge and Whittier earthquakes data are different and exhibit variations attributable to nonlinear effects. One effect is soil-structure interaction which was seen to be more pronounced during the Northridge event. The building possibly experienced rocking at 2.5 hertz in the north-south direction during that event, and there is the possibility that radiation damping (wherein the building dissipates energy into the surrounding soil) contributed to reducing that response. Damping ratios for the building were 10%-15% (north-south) and 5%-10% (east-west) for the Northridge effects, and 1%-4% (north-south) and 5%-8% (east west) for the Whittier effects. These nonlinear effects that tended to reduce the shaking of the building during large ground motions are consistent with the different damping ratios observed during the Northridge and Whittier Narrows events. There was also nonlinear behavior due to minor structural damage during the Northridge earthquake. It is also likely that the cruciform wings responded with a different frequency than that of the overall building. The Olive View Hospital building was conceived and designed as a very strong and stiff structure, particularly in response to the disastrous performance of the original OVH building during the 1971 San Fernando earthquake. However, the resulting design placed the fundamental frequency of the building within the frequency range of the site (2-3 hertz), thereby producing conditions for resonance. This case study indicates that determining the site frequencies needs to be emphasized in developing design response spectra. Despite the site resonances, the performance of the OVH building was considered to be a great success during the Northridge event. The hospital sustained no structural damage under very strong shaking (greater than 2g) at the roof level. Lessons Learned The stiff design of the Olive View Hospital performed very well during the Northridge earthquake, probably saving many lives in a region of very intense shaking. Although the structure did not sustain damage, the hospital had to be evacuated because of broken water pipes and other secondary damage. These elements of the interior design need to be improved in anticipation of future earthquakes.

OLIVE VIEW HOSPITAL - WITHOUT ISOLATION

OLIVE VIEW HOSPITAL - WITHOUT ISOLATION

Civil Engineering has many interesting and challenging problems. Protecting structures against damaging winds and earthquakes is one of the important jobs of a civil engineer.

National Science Foundation Scientists and Engineers in the Schools Program

U.S. Geological Survey http://earthquake.usgs.gov/ http://wwwneic.cr.usgs.gov/

On PBS http://www.pbs.org/wgbh/buildingbig/