CT physics and instrumentation

Slides:



Advertisements
Similar presentations
PRINCIPLES OF CT.
Advertisements

Computed Tomography Principles
Computers and Computed Tomography
Neuroradiology Dr Mohamed El Safwany, MD. Intended Learning Outcomes  The student should be able to understand role of medical imaging in the evaluation.
The Field of Digital Radiography
CARDIOVASCULAR IMAGING WITH COMPUTED TOMOGRAPHY(CT)
A Technical Seminar On X-RAY AND CT SCAN.
Historical Development
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Image Artifacts Chapter 8 Bushong.
Computed Tomography II
Spiral CT Bushong Chapter 5.
Seeram Chapter 13: Single Slice Spiral - Helical CT
Module H Computed Tomography Physics, Instrumentation, and Imaging.
MULTISLICE CT.
SCANCOMEDICAL Computed Tomography SCANCO User Meeting 2005 Dr. Bruno Koller SCANCO Medical AG
Cardiac applications of 16 slice MDCT :Initial experience
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany 1.
Computed Tomography.
Advanced Biomedical Imaging
CT Multi-Slice CT.
CT Physics V.G.Wimalasena Principal School of radiography.
Computed Tomography RAD309
Special Imaging Techniques Chapter 6 Bushong. Dynamic Computed Tomography (DCT) Dynamic scanning implies 15 or more scans in rapid sequence within one.
Chapter 2 Stewart C. Bushong
CT scanning (f) Candidates should be able to show an understanding of the principles of CT scanning. (g) Candidates should be able to show an understanding.
What Are They? Computed Tomography Angiography (CTA)
Multislice CT Coronary Angiography
Conventional and Computed Tomography
Saira Ahmad UOG. CAT Scans CAT Scans ( Computerized axial tomography) Topic:
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
Basic principles Geometry and historical development
Application of Cone Beam Computed Tomography Imaging to Dental and Maxillofacial Practice. ABSTRACT ID NO: IRIA-1162.
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
1 RT 255 C Cross Sectional Anatomy Week 1 FINAL
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
Dr Mohamed El Safwany, MD.
بسم الله الرحمن الرحيم.
Radiographic Evaluation of a Pulmonary Embolism Dr Mohamed El Safwany, MD.
CT physics and instrumentation
CT Seeram: Chapter 1 Computed Tomography - An Overview.
Computed Tomography Q & A
COMPUTED TOMOGRAPHY HISTORICAL PERSPECTIVE
PRINCIPLES OF CT Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture principles of CT.
CT Instrumentation and X-ray system
Factors affecting CT image RAD
Computed Tomography Angiography (CTA). What is CT Angiography? An examination that uses x-rays to visualize blood flow in arterial and venous vessels.
Module A Computed Tomography Physics, Instrumentation, and Imaging.
Methods of Data Acquisition. General Methods of Data Acquisition Localizer scanning Step-and-shoot (axial) scanning Helical scanning.
CT SPECIAL APPLICATIONS. CT ANGIOGRAPHY CT IMAGE OF THE BLOOD VESSEL OPACIFIED BY CONTRAST.
Part No...., Module No....Lesson No
CT ANGIOGRAPHY Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture CT IMAGE OF THE BLOOD VESSEL OPACIFIED.
CONVENTIONAL AND SPIRAL/HELICAL CT
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Background Computed tomography coronary angiography is an accurate method for the non-invasive diagnosis of coronary artery disease Eur Heart J 2005;26:1482–1487.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Basic Principles of CT Scanning. CT CT - Computed Tomography CAT Scan - Computerized Axial Tomography.
Single Slice Spiral - Helical CT
CT Multi-Slice CT.
Computed Tomography Basics
Computed Tomography Data Acquisition
CT GENERATIONS.
CT PRINCIPLES AYMAN OSAMA.
Medical Imaging Imagining Modalities.
Basic principles Geometry and historical development
Computed Tomography (C.T)
Computed Tomography (C.T)
Presentation transcript:

CT physics and instrumentation Lecture (7) Multi-Slice Computed Tomography (MSCT) And Clinical application RSSI 471 Prepared by Mr. Essam Mohammed Alkhybari

Staff contact information: Mr. Essam Mohammed Alkhybari Radiological science and Medical Imaging Department Lecturer in Nuclear Medicine stream E-mail: e.alkhybari@sau.edu.sa

Objective: Background MSCT principle Dual source CT scan Clinical application of MSCT scan

Background: the evolution of MSCT scanners, including the DSCT scanner 1989: Single slice spiral/Helical CT scanner= 1 slice per revolution 1992:Dual slice CT scanners= 2 slice per revolution 1997: Four slice CT scanners= 4 slices per revolution 2000: 8-16 and 32-40 slice CT scanner=8,16,32, and 40 per revolution 2004: 64 slice scanners= 64 slice per revolution 2006: Dual source CT scanner= 2 x-ray Tubes coupled 2 detectors arrays 2006/2007: 320 and 256 slice CT scanners 320 & 256 slice per revolution Future: ? In this slide, I will focus only in the development of MSCT

Background: Slip ring scanners and helical (spiral) CT were rapidly adopted and became the standard of care for body CT However, a significant problem became evident: helical CT was very hard on x-ray tubes. As a result, the more rotation of x-ray tube, creates huge amounts of heat which effects the ability of the scanner.

Background: A straightforward solution to this heat issue, of course, is to develop x-ray tubes with a higher heat capacity Another approach is to more effectively use the available x-ray beam: if the x-ray beam is widened in the z-direction (slice thickness) and if multiple rows of detectors are used, then data can be collected for more than one slice at a time This approach would reduce the total number of rotation and therefore the total usage of the x-ray tube needed to cover the desired anatomy. This is the basic idea of MSCT.

MSCT Detectors: The primary difference between single-slice CT (SSCT) and MSCT hardware is in the design of the detector arrays In MSCT, each of the individual, monolithic SSCT detector elements in the z-direction is divided into several smaller detector elements, forming a 2-dimensional array Rather than a single row of detectors encompassing the fan beam, there are now multiple, parallel rows of detectors

Multi-Slice Spiral/Helical CT: This types of scanner referred to as volume CT (VCT) Systems because covering entire body sections is easily accomplished in a sing breath holds The advantage of MSHCT include isotropic viewing, longer anatomic coverage, multiphase studies , faster examination times, and improved spatial resolution The advancement of VCT, with increasing larger detectors arrays, promises to provide unique clinical opportunities in diagnostic medicine

MSCT CONCEPTS: differences between MSCT AND SSCT Slice Thickness: Single Detector Array Scanners: The slice thickness in single detector array CT systems is determined by the physical collimation of the incident x-ray beam with two lead jaws. Slice Thickness: Multiple detector Detector Array Scanners: The slice thickness of multiple detector array CT scanners is determined not by the collimation, but rather by the width of the detectors in the slice thickness dimension

Cone beam and Fan beam geometry: A cone beam geometry produce more beam divergence along the z-axis direction compared with fan beam geometry For this reason increasing the number of detectors rows in MSCT crates a need for a different approach to the interpolation process because the rays that contribute to the imaging process are more oblique Additionally, the number of detectors rows plays an important role in slice thickness selection and volume coverage During helical acquisition, the data are acquired in a helical path around the patient. Before reconstruction, the helical data are interpolated to the reconstruction plane of interest. Interpolation is essentially a weighted average of the data from either side of the recon- struction plane, with slightly different weighting factors used for each projection angle.

Dual-source CT scanner This dual source CT scanner (DSCT) that features two x-ray tubes and two detectors specifically intended for imaging cardiac patients in a very short time

Dual-source CT scanner: Major Technical components: Tow data acquisition system (DAS) offset by 90 degree Two x-ray tube coupled to two separate detector system Det A which covers the entire scan FOV(50 cm in diameters) Det B which covers smaller central scan FOV (26 cm in diameter) Each x-ray tube is STARTON type that uses the z-flying focal spot technique and cone beam geometry to image 32-slices combined to produce 64 slices per revolution Each x-ray tube can be operated separately, so the scanner can perform dual energy imaging, where one tube operate at 80 kVp and other at 140 kVp

Single source CT Dual Source CT Fast + Poor Image quality Fast + Improved Image quality

Clinical application of MSCT scan: The new helical scanning CT units allow a range of new features, such as : CT angiography CT fluoroscopy, where the patient is stationary, but the tube continues to rotate multislice CT, where up to 64 (128 - 256) slices can be collected simultaneously 3-D CT and CT endoscopy Cardiac image acquisition during relevant heart phases (ECG pulsing synchronization)

CT angiography (CTA): CT angiography defines as CT imaging of blood vessels opacified by contrast media Images can be captured when vessels are fully opacified to demonstrate either arterial or venous phase enhancement through the acquisition of both data sets ( arterial and venous).

CTA

CT Fluoroscopy: Real Time Guidance (up to 8 fps) Great Image Quality Low Risk Faster Procedures Approx. 80 kVp, 30 mA

CT Fluoroscopy: CT fluoroscopy is based on three advances in CT technology: Continuous scanning mode made possible by spiral/helical scanning principle Fast image reconstruction made possible by special hardware performing quick calculations and a new image reconstruction algorithm Continuous image display by use of cine mode at frame rates of two to eight images per second.

CT Endoscopy-Virtual Reality(VR) Imaging: VR is a branch of computer science that immerses users in a computer-generated environment and allows them to interact 3D scenes. A virtual endoscope is a graphic based software system used for simulating endoscopic exploration inside a 3Dimage. In virtual endoscopy, a 3D image acts as ‘copy’ or virtual environment, representing the scanned anatomy

Types of Coronary CT imaging: MSCT (multislice CT) : A new form of cardiac imaging. This is a way to measure obstruction similar to a cardiac catheterization. It is NOT a functional test. Coronary Calcium Scoring: calcium scoring for risk assessment. This is for asymptomatic patients and is not yet recommended as a routine screen. (CCS can be normal in 5% of patients who have myocardial infarcts)

MSCT Coronary Angiography: Details Initial studies 5-10 years ago used 4-slice MSCT. Then came 16-slice (we still use these in some centers) and now 64-slice MSCT is arriving in just the last few years. The 64-slice CT is the current standard (approved in 2004), can handle faster heart rates 256-slice CT angiograms are just starting to be evaluated.

64-Slice CT Scanner More coverage (volume) with each heart beat Entire heart imaged in 5-15 seconds Less contrast required No increase in rotation speed, but with overlapping slices, can use segments from different heart beats to improve temporal resolution

3-D Volume Rendered Image

Questions…!