Ligand structures: ?Say something here! pyridine 2,2’-bipyridine triphenylphosphine Ethylenediamine 2-Benzylpyridine 2,6-diaminopyridine Benzil Results,

Slides:



Advertisements
Similar presentations
Noadswood Science, Sunday, October 12, 2014  To know how flame tests, the pH scale and solubility helps analytical scientists.
Advertisements

Raman Spectroscopy A) Introduction IR Raman
Life always offers you a second chance. It’s called tomorrow.
Electron Configuration and Energy Levels: Ground state: All the electrons in an atom have the lowest possible energies Most stable electron configuration.
Flame Test Lab.
Emission Spectra and Flame Tests. The Big Questions What is light? How is light emitted? What do electrons have to do with light? What are emission spectra?
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Transition Metal Coordination Compounds
Answers to FLAME Test Lab Qs
Spectroscopy Chapter 7.
/28 Flame Tests Make a 2 column by 6 row table in your notebook Label the Columns “Compound” and “Observations” Light your bunsen.
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
Topic 1.1 Matter & Change EI: physical and chemical properties depend on the ways in which different atoms combine. NOS: Making quantitative measurements.
Flame Photometry Flame atomic emission spectrometry
Wickstrom PR 613 Fluorescence. Source Dispersing Sample Detector Computer Lens Dispersing Instrumentation.
Solvatochromism and Photo-Induced Intramolecular Electron Transfer Katelyn J. Billings; Bret R. Findley 1 1 Department of Chemistry and Physics, Saint.
Fluorescence, Phosphorescence, & Chemiluminescence
Metal and Paint Analysis
Flame Photometry The principles.
Menu Substances appear coloured when visible light energy is absorbed by an atom, ion or molecule.
Miriam Israelowitz 1 and Dr. David L. Wilson 2 1 Department of Physics, Case Western Reserve University, Cleveland OH, 2 Deparment of Biomedical Engineering,
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
Properties Physical property: Can be observed without changing the identity (formula) of a substance Chemical Property: Can ONLY be observed when the identity.
* Energetic Light * Why Do Things “Glow”?
Fluorometric Analysis
CHEMISTRY November 5, 2014 Electron Spectrum. SCIENCE STARTER You have 5 minutes. You are seated and quiet Do the Science Starter The Science Starter.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Light Can Act Like Waves or Particles In 1801 Thomas Young an English scientist did the Double slit experiment. In 1801 Thomas Young an English scientist.
Electromagnetic Radiation (NB Pgs 7-9 odd) Picture pg 8.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Fluorescence, Phosphorescence, & Chemiluminescence
Introduction to Thermal Physics
Spectroscopic Analysis of Tb 3+ Doped Sol-Gels In recent years, there has been much research in the field of rare-earth (RE) dope sol-gel glasses. These.
Topic #9 : Ground State vs. Excited State What is the difference between ground state and excited state electron configurations? How can we identify unknown.
Chapter 13.2: d orbitals have the same energy in an isolated atom, but split into two sub-levels in a complex ion. The electric field of ligands cause.
The Effect of Annealing Conditions and Concentration on 5 D 3  7 F J Emission in Terbium-doped Sol-gel Glasses * Colleen Gillespie and Dan Boye, Davidson.
Overview Several complexes of Cu 2+, Ni 2+, and Co 2+ are formed and studied. The observations of color change that result from the addition of a ligand.
Unit 3 Matter & Energy. Characteristics of  Solids:  Matter that holds own _______________  Atoms are ___________________  Rigid structure  Minimal.
Types of Spectra.
Chemistry: The Science of Matter CHAPTER 1. The Puzzle of Matter  Objectives:  Classify matter according to its composition.  Distinguish among elements,
Bell Ringer Log onto SOCRATIVE (room # = crice) OR Get a paper copy! (Turn into the black bin on the front table) READ over your Lab Procedure!!!
Fluorometric determination of riboflavin
The Bohr Atom. The Bohr Theory Evidence: An object at a high temperature emits light. Light and other radiation is emitted from all hot matter.
SPECTROSCOPY Tahoma Jr. High 8 th Grade Science Maple Valley, WA.
Life always offers you a second chance. It’s called tomorrow.
Introduction to Chemical Analysis
ThemesThemes > Science > Physics > Optics > Laser Tutorial > Creating a Population Inversion Finding substances in which a population inversion can be.
Molecular Fluorescence Spectroscopy
SPECTROFLUORIMETRY Prepared By: HIMANSHU SHARA 2010B2A2196P.
Spectral and Electrochemical Characteristics of Silver Complexes and their Potential Metal-to-Charge Transfer Capabilities Matthew Reuter, Roy Planalp,
Molecular Luminescence Spectroscopy
Spectroscopy Chapter 7.
Living By Chemistry SECOND EDITION
Joey Mancinelli, Zane Relethford, Roy Planalp
Spectroscopy Chem honors.
Bromide Photo-oxidation Sensitized to Visible Light in Consecutive Ion Pairs Matt Gray Chemistry 7350 December 11, 2017.
Investigation of the Effect of Ligands on Metal-to-Ligand Charge Transfer Transitions using d10-complexes of Group 11 Elements Evangelos Rossis, Roy Planalp,
IYNT 2017 NANJING Team BULGARIA
Light and Matter Main Concept:
Chapter 4 Preview Multiple Choice Short Answer Extended Response
Raman Spectroscopy A) Introduction IR Raman
Atomic Emission Spectra
Colorimeters.
Chapter 3 Notes: Colored complexes
Where did the elements come from?
Chemistry/Physical Setting
Recall that the vibrational eigenfunctions of a harmonic oscillator are orthogonal: If yj and yk belong to different electronic states as shown here, is.
Consider the experimental evidence you just saw,
Physical Change: Any change which alter a substance without changing its composition is know as a physical change. Ex: Cutting a sheet of paper. Breaking.
Presentation transcript:

Ligand structures: ?Say something here! pyridine 2,2’-bipyridine triphenylphosphine Ethylenediamine 2-Benzylpyridine 2,6-diaminopyridine Benzil Results, Conclusions, and Future Work: Two compounds, benzil and diaminopyridine, were shown to have significant fluorescence in absence of a metal complex. Generally, metal complexes with nitrates showed little to no fluorescence, and one complex even absorbed ultraviolet light. Compounds that coordinated with an odd number of aromatic rings (such as pyridine or triphenylphosphine) generally fluoresced more reliably than other complexes. Copper-halides complexes tend to fluoresce very well, especially when pyridine is used as the ligating compound. For several complexes, however, there are not enough data to support any generalized statement. Future work would involve quantitative analysis of fluorescent compounds, broadening the scope of ligating compounds investigated, as well as increasing the number of metal-halide centers. Acknowledgement: Wilmington College provided funding for the materials for this work. Who was/were you advisor(s)? References: 1. Ford P. and Vogler A. Acc. Chem. Res. 1993, 26, Tard et al. Chem. Mater. 2008, 20, 7010– Knotter et al. Inorg. Chem. 1992, 31, Perruchas et al. Inorg. Chem. 2011, 50, 10682– Kyle et al. J. Am. Chem. Soc. 1991, 113, Dias et al. J. Am. Chem. Soc. 2003, 125, Introduction: When electrons in an excited state return to a lower energy level, they give off photons in a phenomenon called luminescence. When the cause of a molecule’s luminescence is another photon of higher wavelength (and thus higher energy) than the emitted photon, the luminescence is further classified into fluorescence. One method of such excitation involves irradiating the compound with ultraviolet light, as shown in Figure 1. Once in the excited state, any form of energy transfer, including collision with other molecules, lessens or can even destroy a molecule’s fluorescence. A common method of reducing thermal vibrations of molecules is by immersing the substance in liquid nitrogen, which has a boiling point of 77 Kelvin (-196°C). Figure 1: mechanism of fluorescence; excitation of an electron by and emission of a photon. While many compounds fluoresce when chilled with liquid nitrogen, there are also many examples of compounds that fluoresce at room temperature ( Kelvin). Substances that are capable of fluorescing at room temperature can have a different fluorescence at liquid nitrogen temperature. One such compound is pyridine copper (I) iodide, (C 5 H 5 N) n CuI, which shows intense yellow fluorescence at room temperature. When chilled to liquid nitrogen temperature, however, reduction of thermal vibrations allow for the emission of higher energy pink- purple photons, which are otherwise quenched. This evidences? that it is possible to utilize temperature to control the wavelength, and thus the color, of a molecule’s fluorescence, and is the basis of the research done here. A B C D Figure 2: A: luminescence of bis-pyridine copper (I) iodide at room temperature. B: luminescence of bis-pyridine copper (I) iodide chilled in liquid nitrogen. C: luminescence of pyridine copper (I) iodide at room temperature. D: luminescence of pyridine copper (I) iodide chilled in liquid nitrogen. Are these pictures you took? If so say so. Materials: All materials were provided courtesy of Wilmington College, and purchased from Sigma- Aldrich, Fisher Scientific, Experimental: Samples were prepared by combining excess amount of ligating compound with the metal compound in vials, and dissolving in a solvent if necessary. Once all samples had been made, filter paper was sectioned off into eighths and used as the carrier material for each sample, as it (what?) showed minimal fluorescence. Each sample was pipetted onto a section of filter paper, and any solvent or extra liquid was allowed to evaporate. Qualitative data were recorded as the ligand-metal saturated paper was then irradiated with ultraviolet light, followed by an immersion in liquid nitrogen and subsequent irradiation with ultraviolet light. After these data were recorded, the paper was gently heated to potentially remove any extra ligands. How do you know only “extra ”ligands were removed? Once the heating was complete, the filter paper was allowed to return to room temperature and the room and liquid nitrogen temperature irradiation data were recorded. Table 1: Qualitative analysis of fluorescence of various ligand-metal complexes, ordered by ligating compound. Superscript letters indicate solvent in the case of dry complexes (A for acetone, D for dichloromethane, and N for Acetonitrile. Furthermore, bolded luminescence data indicate increased intensity but no change in wavelength, while italicized compounds indicate a molecule lacking a metal center. “Weak” fluorescence is determined as barely observable, while “none” is characterized as having no discernible fluorescence. Fluorescence Thermochromism: Qualitative Analysis Jacob Barrett, Michael J. Goldcamp, Alfred Conklin, Jr. Wilmington College, Wilmington, Ohio, Substance Luminescence beforeand after heating 300K77K300K77K CuI + Benzil A green noneyellow Benzil D green noneyellow NiCl benzylpyridinenone CuI + 2-benzylpyridinenoneblue-greennone NiCl 2 + 2,2’-bipyridine (Bpy) N none NiCl 2 + Bpy A noneweaknone CuI + Bpy A weak Ni(NO 3 ) 2 + Bpy A none Bpy A none NiCl 2 + 2,6-diaminopyridine A blue none CuI + 2,6-diaminopyridine A blue none 2,6-diaminopyridine A blue none CuI + dipicolylamineweak CuI + ethylenediaminenone NiCl 2 + ethylenediamineblue noneweak MnCl 2 + ethylenediaminenonebluenoneblue MnCl 2 + triphenylphosphine (PPh 3 ) A weak NiCl 2 + PPh 3 A weaknoneweaknone CuI + PPh 3 D green weakred PPh 3 A weak none CuI + tris(2-pyridylmethyl)amine (TPA) A none CuI + pyridine (pyr)green yellowpink-purple CuBr 2 + pyrnoneyellownoneyellow-orange Fe(NO3) 3 + pyrnone Co(NO3) 2 + pyrAbsorbs MnCl 2 + pyrweakbluenone CuCl 2 + pyrnonepeachnonedeep orange Cu(NO3) 2 + pyrnone yellow AgNO 3 + pyrnone N/A NiCl 2 + pyrblue weak