Schiotz tonometer.

Slides:



Advertisements
Similar presentations
Intravenous Drug Administration
Advertisements

Technician role in fitting lenses
Goldmann Tonometer.
Advanced Basic Procedure. Handheld Autorefractor Welch-Allyn SureSight Retinomax.
Ocular Trauma Sandra M. Brown, MD 1 and Yair Morad, MD 2 1 Ophthalmology and Visual Sciences Texas Tech University Health Sciences Center Lubbock, Texas.
Transpalpebral Tonometry H.v.Below, O.Riemer Common practice for ambulant and stationary ophthalmology Grimma/Sachsen.
Medication Assistant Training Module 5 Eyes Ears Nose.
Providing First Aid Health Chapter 28.
Prepared by : SIG, Dermatology Nursing, IADVL.  clean the eye of discharge and crusts  prior to eye drop installation  soothe eye irritation  prevent.
Touch Systems Data Entry Module A – N1. LEARNING TO KEY CORRECTLY The human body is not designed for long sessions of repetitive movement. You might even.
 Importance of weighing  Tools for growth (weight) monitoring;  Types of weighing Scale:  Parts of weighing Scales:  Accurate weighing by using a.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Applanation tonometry:
Infection Control AHS II Unit F. Standard Precautions Sometimes called “Universal” precautions Sometimes called “Universal” precautions Used to break.
Recent Advances in IOP measurements
Lumbar Puncture: Indications and Procedure
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Phakic IOL. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly onto the retina,
VITAL SIGNS: T, P, R, & BP.
TOPICAL MEDICATION SHARON HARVEY.
The Canadian Association of Optometrists
INTRAOCULAR PRESSURE LECTURE
OPEN ANGLE GLAUCOMA Frank J. Weinstock, MD, FACS Professor of Ophthalmology- NEOUCOM Canton, Ohio USA.
1 Eye Injuries Pakistan ICITAP. 2 Learning Objectives To be able to identify both a normal eye and an eye suffering from an abnormality To be familiar.
MISCELLANEOUS TREATMENTS. 2 Foreign Body in the Eye  Check for contact lenses, particularly in unresponsive patient  If found, do not attempt to remove.
Keratometry Walter Huang, OD Yuanpei University Department of Optometry.
Module 3c: ASSESSMENT PROCEDURES Module 3c: ASSESSMENT PROCEDURES.
Medical Assistant Skills
Scoliometer HS 349L. Instructions for Use  1. View the person from behind, standing erect.  See figure 1.
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Eye Injuries Chapter 25. Anatomy of the Eye Eye Injuries Can produce severe complications Examine pupil for shape and reaction (if you can see it) Can.
Unit 19 Medical Assistant Skills
Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion.
Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
CHAPTER 11: ADMITTING, TRANSFERRING, AND DISCHARGING.
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Conductive Keratoplasty (CK) Insert name/ Practice name/ Logo here if desired.
P 251 Laboratory Activity 1 Measurement.
First Aid In an emergency, first aid is the care given to a person who becomes injured or ill until regular medical care can be supplied. The most important.
Medication Assistant Training Test 5 & 6 Module 5: Eyes, Ears, Nose, and Skin Module 6: Asthma & Allergies.
BCCO PCT #4 PowerPoint AND HIV/AIDS & Viral Hepatitis In the Criminal Justice Profession TCOLE Course # 3804 FOUR Texas Commission On Law Enforcement and.
$1 Million $500,000 $250,000 $125,000 $64,000 $32,000 $16,000 $8,000 $4,000 $2,000 $1,000 $500 $300 $200 $100 Welcome.
Tonometry Objective measurement of IOP based, most commonly, on the forces required to flatten the cornea,or the degree of corneal indention produced.
BACK SAFETY & SAFE LIFTING Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1PPT
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
BCCO PCT #4 PowerPoint AND HIV/AIDS & Viral Hepatitis In the Criminal Justice Profession TCOLE Course # 3804 UNIT FOUR Texas Commission On Law Enforcement.
Dalia Kamal Eldien Mohammed. introduction  Types of blood specimen include  Venous blood  Capillary blood.
Examination techniques in ophthalmology E. Vlková et al.
TONOMETER.
Mosby items and derived items © 2008 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 15 Body Mechanics.
Intravenous cannulation
Sara Raftery, Mary Clynes and Colleen O’Neill
9. Juni 2016HS-Präsentation1 Tonometer Prisms Disposable versus reusable.
Crede’s prophaylaxis is the instilling of ordered ophthalmic ointment into the newborn’s eyes to avoid damage and blindness due to conjunctivitis brought.
Keratometry and Corneal Topography Instructions. Generally the keratometer & corneal topographer are combined into one instrument that does each reading.
Assisting in slit lamp examination (Applanation & Gonio)
An introduction to the Compound Light Microscope (This is a note check, for p. 3) You must make sure you have these correct for studying them later.
ORBIS International.
Fitness testing for Sport & Exercise
Infection Control 111 Methods.
“Exam” Module Objectives
Irrigation of the eye.
Medical Assistant Skills
By: Mudezzer bin Haji Adnan Harith Khuzairee Bin Mazlan
2/24/2013.
Measuring Height & Weight
Mr Dixon Nampa Agriculture Education
Presentation transcript:

Schiotz tonometer

Schiotz tonometer Professor Hjalmar Schiøtz, the first Director of the Eye Department at the Rikshospitalet, Oslo, from 1897 devised his impression tonometer, originally for use against the sclera of the eye, in 1905. For the next half century the Schiøtz was generally accepted as a reliable means of measuring IOP and became the first tonometer to achieve mass sales. Various fakes also hit the market  Professor Hjalmar Schiøtz

Schiotz tonometer The Schiotz Tonometer is an instrument that measures ocular tension by indicating the ease with which the cornea is indented * Receive an Estimate prior to doing work. * Most Schiotz Tonometers repaired and shipped back in ten business days. * We have the ability to repair Schiotz Tonometers from any manufacturer. * Our Technicians are specialists in Schiotz Tonometer instruments. * Technicians with over 30 years experience examine all Schiotz Tonometers. * All Schiotz Tonometer parts cleaned and adjusted. * Quality control evaluation for Schiotz Tonometer repair. .

The Schiøtz was still offered as a ‘traditional’ instrument (with a choice of straight or oblique scale) in Keeler catalogues of the 1980s but it is now rarely used in the developed world. Before the procedure could begin the footplate had to be sterilised with absolute alcohol or by heating. The practitioner then had to wait for evaporation or cooling to occur. The patient had to be placed in a supine position, without any pillow, and undergo corneal anaesthesia (using Xylocaine). Application of an antibiotic ointment was necessary after the procedure was complete. Impression tonometers can only record a relative measurement and various unavoidable errors might occur due to contraction of the extra-ocular muscles or an eye having a particularly rigid outer coating. Accommodation (which causes IOP to drop) was also a problem, as the patient would somewhat naturally attempt to focus on the instrument heading straight for his eye.

Applanation (Goldmann) tonometry This type of tonometry uses a small probe to gently flatten part of your cornea to measure eye pressure and a microscope called a slit lamp to look at your eye. The pressure in your eye is measured by how much force is needed to flatten your cornea. This type of tonometry is very accurate.

advantages are: • Easy handling • Elegant design • Anodized scale mount which is highly resistant to   sterilizing wear • Independence of sources of current • Delivered in smart padded metal cases, easy to carry with The tonometer with the curved, titled scale is a special favourite, as the values can be read from the top much more easily.

If glaucoma is diagnosed early, treatment can then be given that may preserve vision. Although raised intraocular pressure (IOP) is not the only sign of glaucoma, the IOP should be checked routinely on all adults attending eye care facilities. Applanation tonometry, is the most accurate method to measure IOP, but Schiötz tonometry is also a useful screening test. If Schiötz tonometry reveals a high IOP, this result should be checked and confirmed by applanation tonometry and the patient referred to the senior clinician at the eye clinic.

You will need . 1*Schiötz tonometer, weights, and scale card 02*local anaesthetic drops 3*clean cotton wool or gauze swabs . 4*isopropyl alcohol 70 per cent (methylated spirit) or impregnated ‘Mediswabs’.

Preparation Test the tonometer using the spherical mould in the box and the 5.5 g weight. The pointer should immediately reach the ‘O’ marking Clean the plunger and disc of the tonometer with a gauze swab (or cotton wool) and the methylated spirit (or a Mediswab). Wipe dry with a clean dry gauze swab (or cotton wool). Lie the patient flat with his or her head supported on a pillow.

Method Wash and dry your hands. Position yourself correctly: stand upright, behind the head of the patient, with your hands level with the patient's head. Note the health worker's good posture and the awkward position of the health worker in . Bad posture can affect the tonometry reading. Instil local anaesthetic eye drops and wait about 30 seconds. Ask the patient to look at a fixed object (the patient's own thumb or finger held directly in front of his or her eyes may work) and to keep absolutely still. With the thumb and index finger of one hand, gently hold open the patient's eyelids, taking care not to put any pressure on the eye . With the other hand, hold the tonometer (with the 5.5 g weight) between the thumb and index finger and place the plunger on the central cornea Allow the disc to lower gently onto the corneal surface. Note the scale reading.

If the scale reading is ‘2’ or less, remove the tonometer, replace the 5 g weight with the 7.5 g weight, and repeat the procedure. Note the scale reading again and remove the tonometer. Tell the patient not to rub the eye - the anaesthetic will last for about five minutes. Clean and dry the tonometer head. Repeat the whole procedure for the other eye. Clean and dry the tonometer again and store it safely in the box. Using the scale card, convert the noted scale readings and record the IOP in the patient's records.

The instrument must be held perpendicular to the eye to allow the plunger to move freely, indenting the cornea. The degree of indentation is measured by movement of a needle on a scale. Fine oscillations of the needle represent ocular pulsations, indicating free movement of the plunger and good technique. The midpoint of the needle excursion is taken as the pressure measurement.

The standard force on the plunger producing corneal indentation is a 5 The standard force on the plunger producing corneal indentation is a 5.5 g weight. Globes with elevated intraocular pressure will be resistant to denting by the plunger, resulting in inaccurate measurements. Three larger plunger weights are provided with the instrument and, when added to the standard 5.5 g weight, increase the total plunger weight to 7.5, 10, or 15 g. The extra weights should be used whenever the pressure reading on the instrument scale is 4 or less

Since the Schiotz tonometer does not measure pressure directly, conversion tables, supplied with the instrument, are used to translate scale readings into estimates of intra-ocular pressure.

In patients with known or suspected ocular infection, trauma, or known sensitivity to the topical anesthetic, Schiotz tonometry should not be performed by a primary-care physician. The procedure is further contraindicated in patients who cannot inhibit their blinking, because of the increased risk of corneal abrasion. The actual complication rate of tonometry is quite small, estimated from large screening programs to be less than 1 %, and includes corneal abrasions, infections, and drug sensitivity.