Differential Amplifier

Slides:



Advertisements
Similar presentations
EMG - Force Relationship Signal Processing.3
Advertisements

Electromyography: Recording
Filtering Signal Processing.2
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
BIOPOTENTIAL AMPLIFIERS
Experiment 17 A Differentiator Circuit
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
Depolarization of Muscle Membrane The EMG signal is derived from the depolarization of the muscle membrane. The electrodes record the sum of all of the.
We have so far seen the structure of a differential amplifier, the input stage of an operational amplifier. The second stage of the simplest possible operational.
CHAPTER 3 Measurement Systems with Electrical Signals
EMG Lab Data Collection Toru Tanaka, Miguel Narvaez, Adam Bruenger, and members of the Spring Semester KIN 831 Course.
Electromyography (EMG) Instrumentation
Biofeedback Jennifer L. Doherty-Restrepo Entry-level Athletic Training Education Program PET 4995: Therapeutic Modalities.
The Use of Surface Electromyography in Biomechanics by Carlo De Luca
EMG & Motor Neurons Chapter 18 KINE 3301 Biomechanics of Human Movement.
Neuromuscular Adaptations During the Acquisition of Muscle Strength, Power and Motor Tasks Toshio Moritani.
Lecture 6 Dimitar Stefanov.
Raw Data Trial 1Trial 2 Dave Megan Jeremiah Dianna Ogechi Ambar Difference scores of raw data.
Non-Ideal Characteristics Input impedance Output impedance Frequency response Slew rate Saturation Bias current Offset voltage.
Ref:080114HKNOperational Amplifier1 Lecture 1 Op-Amp Introduction of Operation Amplifier (Op- Amp) Analysis of ideal Op-Amp applications Comparison of.
Additional material for the book: Atlas of Muscle Innervation Zones:
Content Op-amp Application Introduction Inverting Amplifier
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
1 Complex Gain: Basic amplifier concepts Q: What is a Phasor? A Phasor is an ac voltage or current that maintains the same phase with respect to a standard.
A Differentiator Circuit.  All of the diagrams use a uA741 op amp. ◦ You are to construct your circuits using an LM 356 op amp.  There is a statement.
Experiment 17 A Differentiator Circuit
Increased rate of force development and neural drive of human skeletal muscle following resistance training Per Aagaard. Erik B. Simonsen, Jesper L. Andersen,
Da’Janel Roberts Matthew Morgan Jonathan James
Electromyography (EMG) Theory of Operation & Underlying Anatomical and Physiological Issues.
EMG Analysis and Interpretation
Lecture 1 Op-Amp Introduction of Operation Amplifier (Op- Amp) Analysis of ideal Op-Amp applications Comparison of ideal and non-ideal Op-Amp Non-ideal.
Biopotential Amplifier Speaker: Sun Shih-Yu 3/20, 2006.
3/1/2003BAE of 5 Additional Information on Op-Amp Specifications.
The Illinois Society of Electroneurodiagnostic Technologists (ISET) Fall Meeting: Electronics Crash Course for Technologists Saturday, November 9, 2013.
Module 4 Operational Amplifier
Biomedical Instrumentation I
Electromyography IE 665 Dr. Sengupta. Outline Muscle Moment – Moment Arm Review of Muscle Contraction Physiology Physiological Basis of EMG Methods of.
Abstract Our client desires a device to detect the electrical activity of the bladder during the voiding process. The device will be used in a urodynamics.
Resonance Chapter 4. Concert Talk Resonance: definition When a vibrating system is driven by a force at a frequency near the natural frequency of the.
The surface mechanomyogram as a tool to describe the influence of fatigue on biceps brachii motor unit activation strategy. Historical basis and novel.
Unit 8 Operational Amplifier. Objectives: Ideal versus practical operational amplifier Performance parameters Some applications –Peak detector –Absolute.
Differential Amplifier. Surface Electromyography for Noninvasive Characterization of Muscle R Merletti, A Rainodi and D Farina.
Electric wave filters. Physical operation of symmetrical T- and π-Sections. The condition imposed on the above equations are Z in =Z out. Hence I 1 =V.
Signal Conditioning Elements (SCE). 6/13/2016Measurement & Transducers2 1. Voltage dividers Example :Potentiometer circuit.
Electromyography E.M.G..
Module 2 Operational Amplifier Basics
The Working Theory of an RC Coupled Amplifier in Electronics.
BJT Circuits Chapter 5 Dr.Debashis De Associate Professor
Operational Amplifier
Biomedical Instruments Design Biopotential Amplifiers
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
BIOELECTRONICS 1 Lec 9: Op Amp Applications By
Chapter 10: Operational Amplifiers
Three types electrodes are used for sensing of EMG signals:
Experimental methods in nerve muscle physiology
Physiologic signals Lecture 6.
Differential Op - Amplifier TIM. 1 Introduction 2 Differential Amplifier: 2.1 Input Resistances: 2.2 Differential Gain: 2.3 Common Mode Input: 2.4 Common.
Electromyography E.M.G..
Biomechanics of Skeletal Muscle and Electroymography
Electromyography E.M.G..
Digital Control Systems Waseem Gulsher
Germán Sumbre, Graziano Fiorito, Tamar Flash, Binyamin Hochner 
Biofeedback Chapter 7.
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Lesson 12: Analog Signal Conditioning
Electromyographic Manifestations of Muscular Fatigue
Medical electronics II
8.5 Modulation of Signals basic idea and goals
8.3 Frequency- Dependent Impedance
BIOPOTENTIALS, EMG DETECTION
Presentation transcript:

Differential Amplifier

EMG Signal Processing

EMG Amplifier Specifications Amplifiers should be described by the following: If single, differential, double differential Input impedance Common Mode Rejection Ratio (CMRR) Signal to noise ratio Actual gain used Frequency range of amplifier

Noraxon Telemyo EMG Amplifier Input Noise < 1 μV RMS Differential Input Impedance 16 Meg Ohms Common Mode Rejection Ratio CMRR 85 dB Frequency Response 16 – 500 Hz Throughput Circuit Gain 1000

Electrodes Reports on surface EMG should include: Electrode material (Ag/AgCl) Electrode geometry (disc, bars, rectangular) Size (diameter, radius, width x length) Use of gel or paste, alcohol applied to cleanse skin, skin abrasion, shaving of hair Interelectrode distance Electrode location, orientation over muscle with respect to tendons, motor points and fiber direction Intramuscular wire electrodes should be described by: Wire material (stainless steel) Single or multi strand Insulation material Method of insertion (hypodermic needle) Depth of insertion Single or bipolar wire Location of insertion in the muscle Interelectrode distance Type of ground electrode used, location

EMG Amplitude Root Mean Square Average Rectified Value

EMG Linear Envelope Full wave rectify the EMG Low pass filter with a time constant?

EMG Filtering Since the power density spectra of the EMG contains most of its power in the frequency range of 5-500 Hz at the extremes, surface EMG should not be filtered above 10 Hz as a low cutoff and below 350 Hz as a high cutoff. Intramuscular signals should be filtered in the 10-450 Hz range.

EMG Frequency Spectrum The Median Frequency is defined as the frequency that divides the power spectrum in two regions having the same power or area under the Amplitude – Frequency Curve Explain of Power Spectrum should include: Time epoch used for each calculation Type of window used prior to FFT (Hamming, Hanning) Number of zero padding points Equation used to calculate Median or Mean Frequency Muscle length or fixed joint angle

EMG - Force Recruitment of a motor unit. A quanta of force in contributed to the muscle contraction; however, the contribution to the EMG signal amplitude depends on the proximity of the detection surfaces of the electrode to the nearest fibers of the recruited motor unit. A newly recruited MU will increase its firing rate as the force demand increases. The force increase rapidly as a function of the increasing firing rate, whereas the contribution to the amplitude of the EMG signal increases less rapidly

EMG Normalization Subjects should be adequately trained to elicit an MVC. Provide subjects with immediate feedback of obtained force/torque. Give the following information relative to normalization: How the subjects were trained to obtain MVC Joint angle or muscle length Rate of force development Velocity of shortening or lengthening Change in muscle length Range of joint angle in non – isometric contractions Load applied in non – isometric contractions When normalizing the amplitude of the EMG signal, do so at values less than 80% MVC. Above this level the EMG signal and the force (torque) are exceptional unstable and do not provide a suitable reference point (De Luca, JAB 13, p. 154)

EMG Crosstalk Make every effort to determine that EMG crosstalk from muscles near the muscle of interest did not contaminate the recorded signal Select an appropriate electrode size, interelectrode distance and location when working on an area where many narrow muscles are tightly gathered Care also should be employed when recording surface EMG from areas with subcutaneous adipose tissue as it is known that adipose tissue enhances crosstalk.