Analyzing the Image Density. Density Overall blackening of the image.

Slides:



Advertisements
Similar presentations
Producing an X-ray Exposure
Advertisements

Technical Aspects: the machine the image
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
[Radiography] Technique - Exposure Factors
Technique Guidance Systems
Ch. 14 Four Radiographic Qualities Ch
Chapter 11 Prime Factors.
4 Producing Quality Radiographs.
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Primary Exposure Factors IV
Chapter 18 Radiographic Exposure
Components of Radiographic Image Quality
Radiographic Quality Chapter 5.
Chapter 7 Radiographic Image Formation and Exposure Factors.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Chapter 17 The Grid So far we have discussed how kVp, patient size and collimation impact scatter radiation. As the part size and kVp increase, scatter.
Resident Physics Lectures
The Grid Kyle Thornton DMI 50B.
Chapter 19 & 20 Image Quality & Techniques
MAMMO QC – covered in week 8
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
Factors affecting the X-Ray output
X-Ray Production & Emission
X-Ray Production & Emission
Conventional and Computed Tomography
Radiographic Grids I By Professor Stelmark.
Control of Scatter Radiation
P RIMARY E XPOSURE FACTORS : Contrast, Density, Image Quality, technique math 1.
Quality Control.
IMAGE QUALITY REVIEW RT
Dr Mohamed El Safwany, MD.
RAD 354 Chapt. 11 Control of Scatter Break down into: Those that reduce pt. dose and those that are geometrical in nature and those NOT! 3 factors affecting.
Components of Image Quality & Radiographic Artifacts Radiologic Technology A Spring 2010 Final Final.
Mammography Questions and Answers
Chapter 2 The X-ray Beam.
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
Exposure Factors or Prime Factors
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
RAD 254 Chapter 16 Image Quality Film factors Geometric factors Subject factors.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
RAD 354 Chap. 13 Radiographic Technique
Film Optical Density Spectral Matching & sensitometry.
Image Production and Evaluation NOTE: QA AND QC ARE USED INTERCHANGABLY IN APPLETON AND LANGE.
Radiographic Grids I By Professor Stelmark.
Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth Edition Evelyn.
Stacy Kopso, M.Ed., R.T.(R)(M).  Xray photon loses energy and changes direction  Responsible for most of the scatter that fogs the image  Related to.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Lavin: Chapter 7 CTVT: pp
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
Radiographic Technique Sergeo Guilbaud Education Director Long Island College Hospital.
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
Week Seven.
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Exposure Factors or Prime Factors
Producing An Image RVT: Chapter 6. Learning Objectives: Chapter 6 Understand the 4 factors of radiographic exposure and how each impacts the production.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
Chapters 21 & 22.
Stacy Kopso, M.Ed., RT(R)(M)
Factors Effecting the Production
Exposure Factors Chapter 4
Resident Physics Lectures (Year 1)
Resident Physics Lectures (Year 1)
Image Production and Evaluation
Presentation transcript:

Analyzing the Image Density

Density Overall blackening of the image

Assessing Density Anatomical area of interest – OD Darker image preferable to light image

Factors Affecting Density mAs Controlling Factor In the straight line portion of the sensitometric curve, density proportional to log relative exposure. mAs can be adjusted to compensate for changes made in other technical factors.

Density mAs as Controlling Factor Reciprocity Law – Density should remain the same as long as the same mAs is used regardless of the mA and time combination Reciprocity Law failure – Occurs at short exposure times (less than.01) or long exposure times (several seconds)

Density mAs as Controlling Factor Minimum change 30% in exposure – Either 30% change in mAs or other factors that equal 30% change in exposure For mAs changes, adjust in increments of 2 X or ½ mAs

BEWARE The “Step in Time”

Density Kilovoltage 15% increase in kVp doubles the exposure to the film 15% decrease in kVp halves the exposure to the film – In the lower kVp range (30-50), a change of 4-5 % in kVp may be detectable; in the middle range (50-90), a change of 8-9% may be necessary; in the higher range (90-130), % is necessary to detect change in density.

Density kVp – 15% Rule May vary up to 25% rule at high kVp 15% change in kVp will always change Contrast!

Density Influencing Factors Focal Spot Size – Properly calibrated equipment should not exhibit change in density with a change in focal spot size.

Density Influencing Factors Anode Heel Effect – The x-ray beam intensity may vary up to 45% from the cathode to anode end of the beam – More noticeable With small angle anodes With the collimator open wide – Advantage Place thicker or denser body part under cathode end of tube

Density Anode Heel Effect Examples – Femur – Lower leg – Humerus – Forearm – Thoracic Spine – Lumbar spine

Density Distance SID – Inverse Square Law – Intensity of radiation is inversely proportional to the square of the distance from the source – Increase SID, decrease Density I 1 D 2 2 ______ = ______ I 2 D 1 2

Density Maintenance Formula mAs 1 D 1 2 _____ = _____ mAs 2 D 2 2

Density Filtration – Increase in added filtration decreases density

Density Beam Restriction – Reduction of beam size reduces the production of scattered radiation, therefore reducing the amount of radiation reaching the film and reducing density. – Dependent upon: Amount of scatter produced Efficiency of grid Amount of reduction

Density Beam Restriction Usually not necessary to compensate for a restriction in beam size because the change in density is less than 30% and therefore not noticeable. Compensation may be required: Large patient High Kilovoltage technique low grid efficiency (or no grid)

Density Anatomical Part Greater tissue thickness, the less density. Radiopaque contrast media decreases density. Radiolucent contrast media increases density. Destructive pathology increases density. Additive pathology decreases density. Angled techniques decrease density – Variable (depends on degree of angulation)

Density Anatomical Part Angled techniques decrease density – Variable (depends on degree of angulation)

Density Grids Grids absorb scattered radiation, therefore decreasing density. Loss of density compensated for by increasing mAs. Primary purpose of grid is to increase contrast

Density Grids Grid Conversions No grid to:GFC – 5:1 2 MAS 1 GCF 1 – 6: = – 8:1 4 MAS 2 GCF 2 – 12:1 5 – 16:1 6

Density Film/Screen Combination As intensifying screen speed increases, density increases; to compensate mAs is decreased. MAS 1 RS = MAS 2 RS 1 MAS 2

Density Film Processing should not affect density as long as processing parameters are maintained.

Density Increase mAs+Decrease mAs- Increase kVp+ Decrease kVp- Increase generator +Decrease generator – Focal Spot Size0 Anode Heel Effect0 Increase SID-Decrease SID+ Increase filtration-Decrease filtration + Inc. Beam restrict-Dec beam restrict+ Inc. part thickness-Dec. part thickness-

Density Radiolucent CM + Radiopaque CM - Additive pathology -Destructive pathology + Increase grid ratio -Decrease grid ratio + Increase F/S RS +Decrease F/S RD - Increase Processing +Decrease Processing - Increase CR angle - Decrease CR angle +