Fast shower maximum detector based on MCP-PMT Anatoly Ronzhin, Fermilab, AEM, March 10, 2014 Team: Sergey Los, Erik Ramberg, Fermilab Artur Apresyan, Si.

Slides:



Advertisements
Similar presentations
T-979: SiPM Time Resolution with DRS4 Readout Anatoly Ronzhin, Fermilab, AEM March 12, 2012 Team: Mike Albrow, Sergey Los, Pasha Murat, Erik Ramberg, Fermilab.
Advertisements

1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
AFP QUARTIC Fast Timing System James L Pinfold University of Alberta.
Anatoly Ronzhin, March 25, 2014, Fermilab, RTS Anatoly Ronzhin, Fermilab March 25, 2014 Development of a new fast shower maximum (SM) detector based on.
Picosecond Timing with Micro-Channel Plate Detectors Jean-Francois Genat Fast Timing Workshop Lyon, Oct 15 th 2008.
1 Psec-Resolution Time-of-Flight Detectors T979 Camden Ertley University of Chicago All Experimenters Meeting July 14, 2008 (Bastille Day!) Argonne, Chicago,
QUARTZTOFMike Albrow CMS-FP420 April 28 th 2008 QUARTZTOF An isochronous & achromatic Cerenkov Counter Making Cerenkov light parallel  point focusing.
CMS Hadronic Forward Calorimeter Restoration of Functionality Iowa, BU, FNAL severe descoping of HF in 2002 $$ for HB, tracker tail catcher for late developing.
MTest Facility Low Energy Beam Erik Ramberg AEM 15 October, 2007.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Linear Collider TPC R&D in Canada Madhu Dixit Carleton University.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Far forward angle physics at the LHC E. Norbeck and Y. Onel University of Iowa For the 24th Winter Workshop on Nuclear Dynamics South Padre Island
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Groups Involved University of Alberta, University of Texas at Arlington, University College London. Prague, Saclay, Stoneybrook, Giessen, Manchester,
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
1. introduction 2. goal of luminosity monitor 3. Structure of BESII Luminosity detector 4. Calculation of the luminosity 5. MC of luminosity detector 6.
Proposal for Generic R&D on EIC Detectors Yasar Onel University of Iowa.
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
Secondary Emission Ionization Calorimetry Detectors
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
T979: Si-Pms in MTest Anatoly Ronzhin, Fermilab, AEM 12 April, 2010
Page The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes International Conference.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
Detectors and Cross Talk Presented below are cross talk measurements carried out on 2 Burle and 1 Hamamatsu MCP PMTs and 1 Hamamatsu MultiAnode PMT (MAPMT).
Andrew BrandtSept 13 th 2005FP420/Cerenkov Intro 1 Location of LHC in France and Switzerland, with lake Geneva and the Alps in the background The ATLAS.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
Mike AlbrowSept 14 th 2006Time-of-Flight with GASTOFs im Test Beam 1 Fast Timing Counters for FP420/CMS and Test Beam Particle ID Mike Albrow, September.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
Fast Timing Mtg April 15 th 2009 Mike Albrow Fast Timing studies at Fermilab : Test beam plans notes from meeting April 15 th 2009 MTest May Wed 27 th.
QUARTIC STATUS Nov 19 th 2014 Mike Albrow, Fermilab Baseline Plan Detector : Optics, SiPMs, (Readout board, connectors – S. Los) Time schedule Testing.
Anatoly Ronzhin, 23 June, 2009 Anatoly Ronzhin, June 23, 2009 The main results of the TOF study at MT beams, May-June 2009 The team: Anatoly Ronzhin, Hans.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
T979 QUARTIC Timing detectors for HPS240 M.Albrow, A.Ronzhin, S.Malik, Sergey Los, A.Zatserklyanyi, E.Ramberg, Heejong Kim New physics channels for CMS.
Mike AlbrowAll Experimenters, June 8 th 2009T979: Tests of Precision Timing MTest 1 Tests of Fast Timing Detectors in the Meson Test Beam (T979)
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
Beam Halo Monitor : Q-bars+SiPMMike Albrow, 26 Aug 2010 A Beam Halo Monitor for the LHC based on Quartz Cherenkov Counters Mike Albrow (Fermilab) Features:
Update on Physical Parameters that influence Timing Jean-Francois Genat LPNHE Paris LAPPD Electronics & Integration Review July 9th 2012, Chicago.
October 2002Sienna, JL. Faure, DAPNIA/SPP In 8th Topical Seminar on Innovative Particle and Radiation Detectors Jean-louis Faure CEA-DAPNIA-SPP Progress.
HF Calorimeter PMT Upgrade R&D Yasar Onel for University of Iowa, Fairfield University, INFN, Trieste.
Quartz Plate Calorimeter Prototype Hardware & Preliminary Test Beam Data Anthony Moeller The University of Iowa.
Quartic tests at Fermilab test beam June rd 2015 One “prototype” module made. #1 ? To CERN mid July for August test beam.
Gamma Detector of Plastic Scintillator Oct. 2, 2009 IP-BSM Group 1.
TORCH IOP meeting Manchester March 31, 2015 TORCH Maarten van Dijk On behalf of the TORCH collaboration (CERN, University of Oxford,
Aerogel RICH & TOP counter for super KEKB Y.Mazuka Nagoya University June 14-16, 2006 The 3 rd SuperB workshop at SLAC.
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
Mike AlbrowSept 8 th 2005Test Beam for FP420 Vacuum Chambers/Detectors 1 Things we need to test (and why) How we could, together with BTeV people, detectors,
SP- 41 magnet ZDC RPC (TOF) DC ST Target T0 detector MPD / NICA and / Nuclotron Experiments Picosecond Cherenkov detectors for heavy ion experiments.
Gain and Time Resolution Simulations in Saturated MCP Pores Valentin Ivanov, Zeke Insepov, Sergey Antipov 1 First Author Institution, 2 Second Author Institution,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Reed Research Reactor reactor.reed.edu/pictures.html reactor.reed.edu/pictures.html 1 Moriah Tobin Modeling Quartz Cherenkov Detectors.
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
FSC status and plans Pavel Semenov IHEP, Protvino
Light mixer proposal Arjan Heering, Anton Karneyeu
Report from Fermilab: Beam Tests and QUARTZTOFs
BTF microbunching structure with Micro-Channel Plate PMT
Particle Identification in LHCb
Time-of-flight with LAPPD MCP-PMTs & MRPC
Progress on the development of a low-cost fast-timing microchannel plate photodetector Junqi Xie1, Karen Byrum1, Marcel Demarteau1, Joseph Gregar1, Edward.
Latest Results from T979: PSec Time-of-flight
Variable distance from beam.
Status Report on MCP PET Simulation
Performance test of a RICH with time-of-flight information
Presentation transcript:

Fast shower maximum detector based on MCP-PMT Anatoly Ronzhin, Fermilab, AEM, March 10, 2014 Team: Sergey Los, Erik Ramberg, Fermilab Artur Apresyan, Si Xie, Maria Spiropulu, Caltech Andriy Zatserklyaniy, University of Puerto Rico The TB performed in frame of the T979

Our goal One of possibility to make fast and radiation resistant shower maximum (SM) detector (or calorimeter) is to use secondary emitter as an active element. We proposed to use secondary emitter materials (micro channel plates, MCPs) as an active element in sandwich type calorimeter. This work initiated another type research based on PMT dynode system as secondary emitter. The main limits to introduce the technique into practice was high cost of MCPs. Now the cost can go significantly down due to the Large Area Picosecond Photodetector (LAPPD) progress. We present below test beam results, obtained with different type of the detectors based on the MCP-PMT. The time resolution obtained for this new type of detector is at the level of ps. The work could be considered as first step in building new type of calorimeter based on the same principle. Anatoly Ronzhin, March 10, 2014, Fermilab, AEM AEM

New type of SM (calorimeter). Radiation resistant and fast Anatoly Ronzhin, March 10, 2014, Fermilab, AEM Test beam, tungsten absorber thickness changed MCP amplitude in dependence of the tungsten thickness Pulse height MCP schematics

Photek 240 and Photonis MCP-PMT as the SM active element Anatoly Ronzhin, March 10, 2014, Fermilab, AEM AEM

MCP output signal shapes, FWHM ~ 1 ns Anatoly Ronzhin, March 10, 2014, Fermilab, AEM AEM

Test beam setup, DRS4 readout, “electrical” and TOF TR Anatoly Ronzhin, March 10, 2014, Fermilab, AEM

The SM pulsed height and time resolution, 12 GeV, 32 GeV Anatoly Ronzhin, March 10, 2014, Fermilab, AEM Photonis, 12 GeV, 2 mm of quartz, input window, 10 mm of lead Photonis, 12 GeV, 5.5 mm of quartz, 10 mm of lead Photonis 12 GeV, 9 mm of quartz, 10 mm of lead

Summary Anatoly Ronzhin, March 10, 2014, Fermilab, AEM Our first invented tile and fiber calorimeter - used in the lot of experiments – CMS, CDF before, and much more now… We hope that our proposal to use secondary emission as active elements in sandwich calorimeter (as well in shower maximum detectors) also can find a lot of applications. We made measurements with different types of MCP PMT as shower maximum detector. The measurements were performed at the Fermilab Test Beam Facility with 120 GeV/c primary proton beam and 12 GeV/c and 32 GeV/c secondary beams. We obtained time resolution for the SM detector based on Photek 240 at the level of 20 – 30 ps. The SM detector, based on the Photonis MCP-PMT, also achieves a very good TR, ~35 ps. We feel that this level of performance, even with a large MCP pore size (diameter ~25 μm), enables the development of SM detectors for collider experiments at a potentially much reduced cost. The success of the LAPPD project in developing affordable MCP’s is encouraging in this respect. More savings are possible if it can be shown that bare MCP’s without an associated photocathode, can give similar timing performance. We plan on performing a future beam test that can resolve this issue.