Electrons The discovery of the electron was a landmark

Slides:



Advertisements
Similar presentations
Electromagnetic waves are transverse wave, made up of continually changing electic and magnetic fields. Like mechanical waves, electromagnetic waves.
Advertisements

Production of X-rays (1)
Page 1 Wave / Particle Duality PART I Electrons as discrete Particles. –Measurement of e (oil-drop expt.) and e/m (e-beam expt.). Photons as discrete Particles.
Chapter’s 2, 3. & 4 By Garland Fisher
6. Atomic and Nuclear Physics Chapter 6.4 Interactions of matter with energy.
Cathode Ray Tubes and their Uses.
POTENTIAL GRADIENT & CATHODE RAY TUBE
4.6.CATHODE RAY OSCILLOSCOPE Ambar Sarup. What is a Cathode Ray? A cathode ray is a beam of fast flowing electrons.
Thermionic emission If a tungsten filament is heated to about 2000 o C, some of the electrons have sufficient kinetic energy to escape from the surface.
Magnetic Field Patterns
NCEA Physics Thermionic emission.
Cathode ray tube ( oscilloscope)
Radiation Physics II.
Day 19: Electrostatic Potential Energy & CRT Applications
P4: Radiation for Life Lesson 13: Treatment (part 1)
The Professional Development Service for Teachers is funded by the Department of Education and Skills under the National Development Plan The electron.
Electron Microscopy.
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
The Television. Block Diagram AerialTuner Decoder (audio) Decoder (vision) Amplifier (audio) Amplifier (vision) Loudspeaker Picture tube.
ELECTROMAGNETIC WAVES SECONDARY 3 PHYSICS. WHAT ARE EM WAVES? Electromagnetic waves (EM waves for short) are waves that can travel in a vacuum. These.
Topic 29: Remote Sensing 29.1 Production and use of X-rays 29.2 Production and uses of ultrasound 29.3 Use of magnetic resonance as an imaging technique.
Electrons Thermionic Emission
Experiment Number 2 Oscilloscope Dr. Amr A. Abd-Elghany Medical Equipment Technology Department.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
The Cathode Ray Oscilloscope
A phosphor is any material that, when exposed to radiation, emits visible light. The radiation might be ultraviolet light or a beam of electrons. Any fluorescent.
X-ray 1. Use of X-ray a. Medical diagnosis ……………………………………….1 b. Industry …………………………………….……………….2 c. Chemistry ………………………………….……………….2 2. X-ray spectrum…………………………….…..…….6.
The Electron Gun Learning Objective:
The Nature of Electromagnetic Waves
Electrostatic Deflection and Focus Control.  The cathode ray tube consists essentially of an "electron gun" for producing a beam of rapidly moving electrons.
Using an Oscilloscope Electricity Lesson 12. Homework Revise for the exam! Make revision check lists (lists of definitions, equations, derivations), make.
Electromagnetic Spectrum and Light Chapter 18. Electromagnetic Waves Transverse Waves Transverse Waves Consist of constantly changing fields Consist of.
THERMIONIC EMISSION & RADIOACTIVITY
1 PHYS 3313 – Section 001 Lecture #10 Monday, Feb. 17, 2014 Dr. Jaehoon Yu Photoelectric Effect Compton Effect Pair production/Pair annihilation Monday,
© John Parkinson 1 The Cathode Ray Oscilloscope 2 THE CATHODE RAY OSCILLOSCOPE X DEFLECTION PLATES Y DEFLECTION PLATES Electron Beam Vacuum Fluorescent.
Introduction to Graphical Hardware Display Technologies
Properties of cathode rays
LIGHT and MATTER Chapters 12 and 13. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
CATHODE RAY OSCILLOSCOPE Functional Units a) Electron GunElectron Gun b) Evacuated TubeEvacuated Tube c) Deflecting SystemDeflecting System d) Time BaseTime.
The electron.  An indivisible quantity of charge that orbits the nucleus of the atom.
Reading from an Oscilloscope The Oscilloscope An oscilloscope is a piece of scientific equipment which is used to measure voltage which is changing.
Thermionic Valves.
Chapter 17 - Light An electromagnetic wave is composed of electric and magnetic fields that are vibrating perpendicular to each other. An electromagnetic.
Oscilloscope The main purposes of the oscilloscope are: Can view the input waveform voltage or current. Can measure instantaneous values of the input waveform.
4.5 ELECTRON BEAMS ELECTRONS AND ELECTRONICS. Electron Beams Given enough energy, electrons can escape from a conductor and move through a vacuum space.Beams.
20-Jan-16 cathode ray oscilloscope. 20-Jan-16 tube photograph.
The filament is a heated wire from which electrons are emitted. Anodes attract the electrons produced at the filament and accelerate them. X plates deflect.
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
LIGHT and MATTER Chapters 11 & 12. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
5.5 Electric Field and Voltage – Uniform Field p. 200 Electric Field and Voltage – Uniform Field A small test charge will experience a constant force anywhere.
An introduction to the OSCILLOSCOPE and its uses Colin G4GBP.
Electrons Thermionic Emission
1© Manhattan Press (H.K.) Ltd Photoelectric effect Investigation of photoelectric effect Explanation of photoelectric effect by quantum theory Types.
Introduction By Dr. Nimer Khraim DVMS,BVMS,MVSc.
X-Rays Unit 5: Medical Physics. OCR Specification Learning Outcomes: Describe the nature of x-rays Describe how x-rays are produced Describe how x-rays.
 Matter is any thing that occupies space & has mass  Present in three states: solid, liquid, & gas  It could be divided into elements & compounds 
Describe how X-rays interact with matter using the photoelectric effect, Describe the Compton effect and pair production. Define intensity and use the.
Chapter1 & 9 History of Radiology and X-ray Tube
Fundamentals of radiography.
Cathode ray oscilloscope. CRO
Laboratory equipment Lecture (3).
X-RAY PRODUCTION AND EXPOSURE FACTORS
X-Radiation.
PRODUCING AND USING STREAMS OF ELECTRONS
X-Rays.
Electrons Thermionic Emission
Electrons & Energy Levels
Thermionic Emission – Learning Outcomes
The Electronic Structure of Atoms
Wave / Particle Duality
Presentation transcript:

Electrons The discovery of the electron was a landmark in physics and led to great technology advances

Cathode Ray Oscilloscope Introduction Thermionic Emission Cathode Rays Deflection of an electron beam Cathode Ray Oscilloscope Uses of the CRO

Thermionic Emission There is a certain minimum threshold energy which the electron must have to escape. The negative charges, in the form of electrons, escape from the filament when it’s hot because they have enough energy to get free from the metal surface.

Cathode Rays Beams of electrons moving at high speed = Cathode Rays Electrons accelerated toward anode – pass through the hole – miss the cross – the screen to fluoresce – cast a shadow of the cross

Deflection of an electron beam The deflection of an electron beam can be caused by A magnetic field Force on electron 2. An electric field

Cathode Ray Oscilloscope The CRO has three main parts i.e. Electron Gun Deflecting System Florescent Screen

Electron Gun Electrons are produced by thermionic emission. Essentially a cathode(negative electrode) is heated and electrons boil off the surface to be attracted by a series of anodes (positive electrodes). The anodes accelerate the electrons and collimate them into a narrow beam.

Deflection System Consist of two pairs of parallel plates : X-Plates and Y-Plates To display a waveform, a repetitive reversing voltage is applied to the X-plates. This causes the electron beam to be slowly repelled from the left-hand plate and attracted towards the right-hand plate. On the CRO screen this translates as an illuminated dot moving from left to right.

The voltage is then reversed and increased rapidly The voltage is then reversed and increased rapidly. The effect is to move the dot very quickly right to left (fly-back). The applied voltage is called the time-base. The curve has the general shape of a 'saw-tooth'. The p.d. applied to the Y-plates is the signal to be examined. With the p.d. across the X-plates, a sine waves is displayed

Display The display screen is coated on the inside with a very thin layer of a phosphor called cadmium sulphide. This fluoresces (gives out green light) when electrons impact its surface.

Uses of CRO A CRO can be used for Measuring Potential Differences Displaying waveforms Measuring time interval & Frequency

Potential Difference Signal Frequency signal

X-Rays X-Rays are produced when high-speed electrons are stopped by matter In an X-ray tube, electrons from a hot filament are accelerated across a vacuum to the anode X-rays The anode is a copper block with a ‘target’ of a high-melting-point metal such as tungsten on which the electrons are focused by the electric field between anode and concave cathode

X-Rays X-Ray Properties Penetrate matter up to 1 mm of lead Not deflected by electric or magnetic field Ionize a gas Affect a photographic film Cause fluorescence Give interference and diffraction effects

X-RAYs X-rays can travel through soft substances but not hard, dense ones. They travel through soft tissue, but not hard bone. X-rays are used in hospital to make shadow pictures of parts of the body. X-rays are used at airport to check what may be hidden in the luggage.

Photoelectric Effect In the photoelectric effect, electrons are emitted from matter (metals and non-metallic) as a consequence of their absorption of energy from electromagnetic radiation of very short wavelength, such as ultraviolet light.