The Future of Irrigation Metering. SEAMETRICS ™ FLOW METERS -PRODUCT OVERVIEW-

Slides:



Advertisements
Similar presentations
INTRODUCTION: Developed from patented derivatives from advanced Naval SONAR technologies, the STARS is a new device designed to help increase situational.
Advertisements

MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
ULTRASONIC WATER AND FLOW METERS
Psion Teklogix 7535 Handheld Computer.
Visit us at MCS Products Visit us at
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
PLUMBING DESIGN © Copyright 2008 HVAC Design Solutions1 Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design” Essential.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Introducing INW Sensor Technology. Sensor History at INW Analog Pressure Sensors 1985 Analog pH & ISE Sensors 1995 Smart Pressure Sensors 2002 Smart pH.
MineralScan Lite Installation Guidelines Digital Control Lab, LLC NW 6 th Street, Suite F Gainesville, FL Main Unit power 90 – 240 VAC 50/60.
Tachometers – An Overview
Step 1: Set the desired flow rate for each pipe. Step 2: Click on the stream which you wish to size the pipe. Select Sizing from the menu, then select.
Changing Settings On the Seametrics FT400-Series
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Rapid Pneumatic Transportation of Radioactive Samples System Steve Padalino & Ed Pogozelski SUNY Geneseo.
Importing text files in an MS Excel spreadsheet Wim Buysse – ICRAF-ILRI Research Methods Group August 2004 Research Methods Group.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Wireless Data Acquisition for SAE Car Project by: J.P. Haberkorn & Jon Trainor Advised by: Mr. Steven Gutschlag.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
Installation of Mags What details need to be planned out? Manufacture requirements IDWR requirements Site selection for installation Examples of good and.
October 2009 Custom Products & OEM Opportunities.
EESIFLO International Pte Ltd
Contamination Control in
CPSC 203 Introduction to Computers T43, T46 & T68 TA: Jie (Jeff) Gao.
By Norman Bartlett Creative Sensor Technology 1. Irrigator’s View of Landscape Irrigation “ We are beautifying the world” Public’s View “You are wasting.
Looking for a more powerful circuit monitor?
HVAC523 Circulator Pumps.
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Probe12 Sap Velocity based Sap flow logger & Irrigation Scheduler.
900 MHz radio link between two remotely located Weather Stations
XP Practical PC, 3e Chapter 18 1 Buying a PC. XP Practical PC, 3e Chapter 18 2 Buying a PC In this Chapter, you will learn: –Where to begin looking for.
DMC / total energy metering.pptslide 1 July 01 Daniel Measurement & Control Kyoung Su Kim.
High Sensitivity Smoke Detection
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
RPM Series Rotary Meters Presented by Mike Javon Product Coordinator Industrial Products Business Unit.
Exacta ™ Digital Torque Wrenches Sturtevant Richmont Global Reach. Local Support.
October 1, 2012 PAX2C Product Launch. 2 © Red Lion Controls Inc. PAX 2 C Universal PID Controller.
 Controllers  RCX  Wall mount  Panel mount  Controller with data logger  SMX  Wall mount  Panel mount  Data loggers  DUE  Wall mount  Panel.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Automating Continuous Gas Lift
Welcome to Product Workshop 2008!. The Indication Group Panel Meters Large Displays Sensors Temperature Controllers Signal Conditioners.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Environmental Monitoring at MU Libraries Presented by Amanda Sprochi and Gary Cox.
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
ATM-900 Series Acoustic Telemetry Modems Introduction and Overview Communication Group: Justin Manley – Senior Director of Business Development Debbie.
Force Feed Lubricator System
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
1 Sensors and Switches... WHAT’S IN THE BOX? 2 Sensors and Switches... SENSORS, CORDSETS & PROX SWITCHES.
Brooks Expert Support Tool (BEST) Software
USonic-R™ Remote 2-Channel System
Creative solutions for water management for Irrigation Control Systems
Creative solutions for water management with Irrigation Smart Control Systems
Open Minds ESL Electronic Shelf Label
Module – Groundwater Level Measurement
Flow-X/C Flow Computer
Nematron® EnduraTouch II 17” Enclosed Computer Launch
Statistical Analysis with Excel
Horizontal Installation Overview
Statistical Analysis with Excel
Nematron® EnduraTouch II 17” Enclosed Computer Launch
Customer Presentation
Customer Presentation
Ultrasonic Flowmeter Technology
PQube® 3 Standard Pre-Wired Packages for quick and easy installation
Presentation transcript:

The Future of Irrigation Metering

SEAMETRICS ™ FLOW METERS -PRODUCT OVERVIEW-

AG2000 – SERIES IN-LINE MAGMETER

Specifications, Ag 2000 Flanged meter, 4”, 6”, 8”, 10” Flange with holes ANSI 150 lbs Pressure, up to 150 psi, 10.3 bar Temperature range: -12 to 54 degrees (C) Precision: 99.5% + Totalizer: Volume at 6 digits, totalizer at 8 digits, gallons, lps, m3/hr 2 “D” batteries (lithium), 5 year warranty

Installation/Specifications, Ag 2000 Option of internal datalogger Installation of meter 2 x distance of diameter of meter and 1x distance of diameter downstream Compatible with most common telemetry communication (10 units/pulse; 100 units/pulse;1000 units/pulse, high frequency) Officially approved by Conagua since 2007

What do you need to order? REQUIRED: Meter + Size + Rate + Total i.e., AG cfs-ft 3 Options: Output/AC power cord 20ft = -11/6 50ft = -11/35 Data Logger Option -126 Data Transporter Option (Harvest ‘09) Blind Analog Convertor AO55W

EX-80 Series Fixed Depth Insertion Magmeter

EX-80 fixed insertion magmeters Pipe sizes from 1” to 12” Economical Fittings/Saddles from Seametrics to mount the meters 24 vdc via direct power source or solar panel -17 to 72 degrees (c) Pressure at 150 psi min (200 psi with brass/ss fittings)

What do you need to order? Sensor – by pipe size and material 81 series = 1-3 inch 82 series = 4-10 inch 83 series = 12” Brass, 316 Stainless Steel, or PVC Example: EX81B = EX meter, 1-3 inch, brass body EX82P = EX meter, 4-10 inch, PVC body

Options: Reverse Flow Output = -15 Immersible = -40 Low Power Option = -50 Viton ® O-Ring = Indicator: Do you need an indicator or do you have a PLC panel? if so, add FT420/FT421 (this will be covered later)

Power Supply The EX meter runs on an external AC power supply. You may purchase the following from SeaMetrics: PC2 (panel type)/PC3 (outlet type) VAC, 24 VDC power convertor *** for use with sensor and no indicator PC42 Dual Power Supply *** necessary to power sensor/indicator combo

How will you mount your sensor? EX80 series meters are fixed depth and require a special saddle/weld/tee fitting from SeaMetrics to insure accuracy. A standard saddle cannot be used on an EX80 Series meter. Use the following chart to determine how you want to install your EX80 Series Meter:

For the EX83, the ductile iron saddle may be used as -1200, or any of the weld on fittings may be ordered as a

Do you need a Datalogger? Order a DL76W or DL76M to go with your EX 80 METER! See Datalogger Section for information on how to order!

Seametrics EX100/200 Series Variable depth insertion magmeters

Would you rather have an adjustable depth meter? Try the EX101/201 for 3-10 inch or 10-48” pipe! How about a “hot-tap” meter? Try the EX115/215! All of these units order just like an 80-series, but, may use standard saddles! See the price list for options/details…

TX and IP Meters Turbines and Paddlewheels

Like the EX Series, the TX and IP series come in fixed depth as well as Adjustable and Adjustable hot-tap… The formula for creating a TX or IP is the same as an EX… TX81P = turbine meter, 1.5 to 3”, PVC body see the catalog for options available…

As with the EX, the TX and IP have an 80 series, fixed depth which require specific SeaMetrics- made saddles, while the 101, 201, 115, & 215 can use any standard saddle or weld fitting. Charts showing the corresponding 80-series saddle/fitting are found in your price list. There is, one major advantage to the TX and IP meters over the EX-Series…..

POWER SUPPLY AND POWER USED!!! If, and only if, you intend to use and FT400- series indicator, and require no signal output, you can use BATTERY POWER on these meters. Do so by ordering an FT415 (battery operated indicator) and “jumping” it to the Sensor.

ORDERING FT400’s and DL76’s

Most of SeaMetrics’ components are modular when used with an insertion-style meter… Individual parts, FT400, DL76, etc. can be interchanged by attaching to the meter or mounting separately.

Both the FT400 Series Indicator and the DL76 Series DataLogger may be mounted on the sensor itself (only one of them can meter-mount at a time), or as a separate, wall-mountable part. This will allow the end-user to decide whether or not the meter will be read or logged from the point of installation or from several feet away. The indicator or datalogger position is indicated by the desingnation “w” or “m” (wall or meter). Example : FT420M, DL76W

Ordering the FT400 Series Indicator Choose a base model, FT420 (AC powered), FT415 (Battery powered), FT421 (AC/total in AF). Choose a mounting method, M (meter), W (wall), or P (panel, FT420/421 only) Choose any options… (see price list) Your order will look like this FT420W-98 Indicator, AC power, Wall mounted, with dual relay output.

Ordering the DL76 Datalogger DL76 can be ordered as W (wall mount) or M (meter mount). Or Internal on the AG2000 Along with the DL76, you need… DC3 – Download Cable FI-SW-4 or FI-SW-16 – Software and Licenses **Coming in 2009 – the Data Transporter/Drive

Introducing….. the AG700 “Bullet Meter” To be released…. Fall of 2009! Same firmware as the AG2000 Same/Similar close coupling availability Ease of installation of a saddle meter

The WMP104 and WMP inch in-line flow meter Based on similar design to the AG2000 WMP Runs on AA batteries (life expectancy is one year) No output signal WMP Requires a power supply Produces output signal (pulse) Both units mount with standard Banjo ® fittings

Datalogger DL 75 powered by a battery, for insertion meters or external mounted datalogger (AG 2000 has internal datalogger with same functions) Stores information for weeks or months, depending on set frequency rating (max. 180 days) With Flowinspector software, you can download, store, view, graph, chart, print data in several formats Download information via handheld data transporter or laptop

Flowinspector Software PC Compatible Computer with min.: Windows 98, NT, 2000, XP, Vista; CDRom drive,USB port, Seametrics DC3 data cable Can view all the information on the screen, zoom in by date/time, etc., excel spreadsheet or comma delimited Export Software for one meter or multi meters (up to 16 units/software package)

Other Products from Seametrics Low Flow magmeters for chemigation, other low flow applications In-line meters (turbine), of ¾” to 10 inch

Accessories from Seametrics Saddles, solar panels, splitters, other items