The CMS Detector Paoti Chang National Taiwan University

Slides:



Advertisements
Similar presentations
TIME 2005: TPC for the ILC 6 th Oct 2005 Matthias Enno Janssen, DESY 1 A Time Projection Chamber for the International Linear Collider R&D Studies Matthias.
Advertisements

Guoming CHEN The Capability of CMS Detector Chen Guoming IHEP, CAS , Beijing.
Detectors & Measurements: How we do physics without seeing… Prof. Robin D. Erbacher University of California, Davis References: R. Fernow, Introduction.
First CMS Results with LHC BeamToyoko Orimoto, Caltech 1 First CMS Results with LHC Beam Toyoko Orimoto California Institute of Technology On behalf of.
The ATLAS B physics trigger
LHC SPS PS. 46 m 22 m A Toroidal LHC ApparatuS - ATLAS As large as the CERN main bulding.
First CMS Results with LHC BeamToyoko Orimoto, Caltech 1 First CMS Results with LHC Beam Toyoko Orimoto California Institute of Technology On behalf of.
Description of BTeV detector Jianchun Wang Syracuse University Representing The BTeV Collaboration DPF 2000 Aug , 2000 Columbus, Ohio.
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
LHeC : Muon Systems L. Pontecorvo.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
The BTeV Tracking Systems David Christian Fermilab f January 11, 2001.
Performance of ATLAS & CMS Silicon Tracker Alessia Tricomi University and INFN Catania International Europhysics Conference on High Energy Physics EPS.
Workshop on Quarkonium, November 8-10, 2002 at CERN Heriberto Castilla DØ at Run IIa as the new B-Physics/charmonium player Heriberto Castilla Cinvestav-IPN.
The SLHC and the Challenges of the CMS Upgrade William Ferguson First year seminar March 2 nd
EPS 2003, July 19, 2003David Buchholz, Northwestern University Performance of the D0 Experiment in Run II Detector Commissioning and Performance Accelerator,
David Attié Club ‘ILC Physics Case’ CEA Saclay June 23, 2013 ILD & SiD concepts and R&D.
July CMS experiment at LHC Geoff Hall Imperial College London Geoff Hall.
Roger Rusack – The University of Minnesota 1.
J-C BRIENT Prague Performances studies of the calorimeter/muon det. e + e –  W + W – at  s=800 GeV Simulation SLAC-Gismo Simulation MOKKA-GEANT4.
ELECTROMAGNETIC CALORIMETER at CMS EVANGELOS XAXIRIS June 2005 Experimental Physics Techniques.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
CHEP06, Mumbai-India, Feb 2006V. Daniel Elvira 1 The CMS Simulation Validation Suite V. Daniel Elvira (Fermilab) for the CMS Collaboration.
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
C. K. MackayEPS 2003 Electroweak Physics and the Top Quark Mass at the LHC Kate Mackay University of Bristol On behalf of the Atlas & CMS Collaborations.
CMS ECAL performance and upgrade Anton Karneyeu (INR, Moscow) CMS Collaboration INSTR14, Novosibirsk, Russia, 27 February 2014.
Operation of the CMS Tracker at the Large Hadron Collider
The ZEUS Hadron-Electron-Separator Performance and Experience Peter Göttlicher (DESY) for the ZEUS-HES-group Contributions to HES Germany, Israel, Japan,
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
RPCs in CMS Supreet Pal Singh India-CMS Meeting, July 20-21, 2007
P ARTICLE D ETECTORS Mojtaba Mohammadi IPM-CMPP- February
The CMS detector as compared to ATLAS CMS Detector Description –Inner detector and comparison with ATLAS –EM detector and comparison with ATLAS –Calorimetric.
May 1-3, LHC 2003V. Daniel Elvira1 CMS: Hadronic Calorimetry & Jet/ Performance V. Daniel Elvira Fermilab.
Observables in heavy-ion collisions at CMS Haidong Liu
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Coil and HCAL Parameters for CLIC Solenoid and Hadron-calorimetry for a high energy LC Detector 15. December LAPP Christian Grefe CERN.
Luca Spogli Università Roma Tre & INFN Roma Tre
The Compact Muon Solenoid. What does CMS do? The Compact Muon Solenoid is a general purpose particle detector installed at point 5 of the Large Hadron.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
Jessica Leonard, U. Wisconsin, December 19, 2006 Preliminary Exam - 1 H->  Jessica Leonard University of Wisconsin - Madison Preliminary Examination.
R.S. Orr 2009 TRIUMF Summer Institute
First CMS Results with LHC Beam
Andrew York, University of Tennessee On behalf of the Tracker Project APS DPF 2009 Commissioning the CMS Pixel Detector 7/28/
Detectors for VEPP-2000 B.Khazin Budker Institute of Nuclear Physics 2 March 2006.
TeV muons: from data handling to new physics phenomena Vladimir Palichik JINR, Dubna NEC’2009 Varna, September 07-14, 2009.
Edouard Kistenev for the PHENIX Collaboration Calorimetry based upgrade to PHENIX at RHIC CALOR 2012 Santa Fe, NM, June 4-8, 2012.
July 27, 2002CMS Heavy Ions Bolek Wyslouch1 Heavy Ion Physics with the CMS Experiment at the Large Hadron Collider Bolek Wyslouch MIT for the CMS Collaboration.
LHC Symposium 2003 Fermilab 01/05/2003 Ph. Schwemling, LPNHE-Paris for the ATLAS collaboration Electromagnetic Calorimetry and Electron/Photon performance.
The Collider Detector at Fermilab (aka CDF) Jennifer Pursley Intermediate Seminar Oct. 28, 2003.
SPHENIX Mid-rapidity extensions: Additional Tracking system and pre-shower Y. Akiba (RIKEN/RBRC) sPHENIX workfest July 29,
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
CMS Status & Commissioning Menu: 1 Recent Progress Commissioning Prior to and After First Beam Commissioning with first LHC Events Outlook Wolfgang Funk.
Four Seas Conference Iasi, Romania, 30 May 2007 Overview of the CMS Experiment Claudia-Elisabeth Wulz CMS Collaboration Institute for High Energy Physics.
A. Parenti 1 RT 2007, Batavia IL The CMS Muon System and its Performance in the Cosmic Challenge RT2007 conference, Batavia IL, USA May 03, 2007 Andrea.
Operation, performance and upgrade of the CMS Resistive Plate Chamber system at LHC Marcello Abbrescia Physics Department - University of Bari & INFN,
(University of Sofia “St. Kliment Ohridski”)
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
Layout of Detectors for CLIC
CMS muon detectors and muon system performance
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
The Compact Muon Solenoid Detector
5% The CMS all silicon tracker simulation
A study on stochastic term of calorimetric energy resolution
Muon Detector Jiawen ZHANG 16 September 2002.
Project Presentations August 5th, 2004
Performance of ATLAS & CMS Silicon Tracker
ELECTROMAGNETIC CALORIMETER
Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM)
Presentation transcript:

The CMS Detector Paoti Chang National Taiwan University Workshop on LHC Physics and the Strategies for Discovery Taipei, Taiwan, Jan. 14, 2008 1/14/08 NTU, Taipei The CMS Detector

Detector Requirement Good Muon identification;good dimuon mass resolution (~1% at 100 GeV); distinguish charge at 1 TeV. Good momentum resolution for charged tracks. Efficient triggering and off-line tagging on t and b-jets. Good EM energy resolution; good diphoton and dielectron mass resolution; wide geometrical coverage; p0 rejection and efficient photon and lepton isolation Good missing-transverse-energy and dijet mass resolution  high-field solenoid, full-silicon-based inner tracking system and a homogenous scintillating-crystal-based electromagnetic calorimeter 1/14/08, NTU, Taipei The CMS Detector

Overview of the CMS Detector 1/14/08, NTU, Taipei The CMS Detector

Superconducting Magnet Special features: 1. Winding composed of four layers 2. Mechanically reinforced with aluminum alloy 3. Large dimension 6.2 m cold bore, 12.5m length,220-t mass 1/14/08, NTU, Taipei The CMS Detector

Main parameters CMS decides to use lower field, 3.8T. 1/14/08, NTU, Taipei The CMS Detector

CMS Barrel Yoke ready for coil and muon Detector 1/14/08, NTU, Taipei The CMS Detector

Inner Tracking System ⇕ Provide precise measurements of track trajectories and secondary vertices. L= 1034 cm-2 s-1  1000 particles from >20 inter. high granularity and fast response of electronics Keeping minimum amount of material 3 layers of pixel to reduce occupancy (4.4-10.2 cm) 10 layers of silicon strip detectors (R ~ 1.1 m) endcaps: 2 disk pixel and 3 plus 9 strip on each side ⇕ 1/14/08, NTU, Taipei The CMS Detector

Overview of the tracker layout Acceptance |h|<2.5, 200 m2 silicon area, 1440 pixel and 15148 strip modules. pixel: 100x150 mm2; Inner silicon: 10cm x 80mm; outer silicon: 25cm x 180 mm 1/14/08, NTU, Taipei The CMS Detector

Expected Hadron Fluence and Radiation Dose L = 500 fb-1, 10 years of LHC running Surface damage on readout chips  0.25mm CMOS chip (rad. hard) Increasing leakage current  low temperature -10C to -27C transient phenomena 1/14/08, NTU, Taipei The CMS Detector

Pixel Detector barrel support structure Layout overview  material budget 1/14/08, NTU, Taipei The CMS Detector

Barrel Pixel Detector Modules 1/14/08, NTU, Taipei The CMS Detector

Forward Pixel Sketches of two types of FPix panels Half cylinders Sketch of of a plaquette mounted in a panel 1/14/08, NTU, Taipei The CMS Detector

Status of Pixels 1/14/08, NTU, Taipei The CMS Detector

Overview of Silicon Strip Detector 1/14/08, NTU, Taipei The CMS Detector

Silicon sensor 320 mm sensors 500 mm sensors Active region 1/14/08, NTU, Taipei The CMS Detector

Silicon Tracker Inner Barrel and Endcap Exploded views of a module of two sensors Three TIB modules in a shell 1/14/08, NTU, Taipei The CMS Detector

Outer Silicon Tracker Each sector consists of 9 front petals and 9 back petals d = 2.3 m Endcap outer silicon strip detectors TOB wheel 1/14/08, NTU, Taipei The CMS Detector

Rod an Petal Double sided rod Front and back panels for TEC 1/14/08, NTU, Taipei The CMS Detector

Expected Performance Transverse momentum Impact parameter in r Impact parameter in z 1/14/08, NTU, Taipei The CMS Detector

Electromagnetic Calorimeter The CMS ECAL consists of a hermetic homogenous calorimeter made of 61200 lead tungstate (PbWO4) crystals in the central barrel part, ~7324 crystals in each of the two endcaps, and a preshower detector in front of the endcap crystals. Advantages of PbWO4: 1. high density (8.28 g/cm3); 2. shorter rad. Length (.89 cm) 3. short Moliere radius (2.2 cm); 4. fast radiation decay time (80% of the light in 25 ns)  fine granularity, radiation hardness and compact calor. 1/14/08, NTU, Taipei The CMS Detector

CMS-PbWO4 1/14/08, NTU, Taipei The CMS Detector

Layout of the CMS ECAL Barrel: |h| < 1.479 360 fold in f 2x85 fold in h crystal size: front: 22x22 mm2 back: 26x26 mm2 length: 230 mm 25.8 X0 Endcap: 1.479< |h| < 3.0 1 unit = 5x5 crystals. crystal size: front: 28.62x28.62mm2 back: 30x30 mm2 length: 220 mm 24.7 X0 1/14/08, NTU, Taipei The CMS Detector

ECAL Modules Barrel supermodule (1700 crystals) Module of 200 crystals 1/14/08, NTU, Taipei The CMS Detector

ECAL-Barrel 1/14/08, NTU, Taipei The CMS Detector

Preshower Detector 1.653<|h|<2.6; total length 20 cm. Twp parts: lead radiators and silicon strip sensors. Taiwan involvement: NCU: 1/4 silicon sensors NTU: System Motherboards 1/14/08, NTU, Taipei The CMS Detector

Calibration and Resolution channel-to-channel variation: use lab. measurements on light yields and photo-dio. response.  5% in barrel and 10% in endcap Beam test p0/h →gg in data; w →en. Laser Monitor system Energy resolution 1/14/08, NTU, Taipei The CMS Detector

Performance of a typical 3x3 crystals 1/14/08, NTU, Taipei The CMS Detector

Status of ECAL Endcaps & Preshower Preshower: testing micro modules, motherboards and preparing to install in April 1/14/08, NTU, Taipei The CMS Detector

Longitudinal View of the CMS Det. HCAL Barrel HCAL Endcap HCAL Forward 1/14/08, NTU, Taipei The CMS Detector

HCAL Barrel (HB) The HB consists of two half-barrels, each of which contains 18 wedges. Each wedge corresponds to 4 f sectors. The absorber consists of a 40-mm thick front steel plate, 8 50.5-mm-thick brass plates, 6 56.6-mm-thick brass plate, and a 75-mm-thick steel back plate. 16 h 5.82 lI at 90 and 10.6 lI at h=1.3 wedge Half barrel 1/14/08, NTU, Taipei The CMS Detector

The HCAL Tower Segmentation Plastic scintillators 1/14/08, NTU, Taipei The CMS Detector

Endcap Calorimeter (HE) Yoke Close to magnet, non-conducting absorber has to be used.  C26000 cartridge brass 1/14/08, NTU, Taipei The CMS Detector

HCAL Endcaps Scintillator Tray HE Wedges 1/14/08, NTU, Taipei The CMS Detector

Forward Calorimeter Situate at |h| = 5 Detect particles through its Cherenkov light. Require good EM response (electrons). Serve as luminosity monitor Methods: zero counting and average ET per tower 1/14/08, NTU, Taipei The CMS Detector

Expected Performance Jet energy resolution 1/14/08, NTU, Taipei The CMS Detector

Muon System Identify muons, measure momentum and trigger muon events. The muon system consists of three types of gaseous detectors: 1. four layers of drift tubes in |h|<1.2 2. cathode strip chamber covering |h| to 2.4 3. resistive plate chambers 6 layers in barrel and 3 in endcaps ( |h| < 1.6 ) 1/14/08, NTU, Taipei The CMS Detector

Layout of Drift Tube Chambers One layer is inside the yoke, one is outside, and the other two are embedded within the york. One of the five wheels. 60 chambers in the first three layers and 70 in the last. 1/14/08, NTU, Taipei The CMS Detector

Sketch of Drift-Tube Cell Gas: 85% Ar + 15% CO2 Top and bottom plates are grounded. The voltages applied to the electrode are +320V for wires, +1800 V for the strips and -1200 V for the cathode. 1/14/08, NTU, Taipei The CMS Detector

Installation of MB1 on Wheel 2 Each DT chamber is made of 3 (or 2) superlayers, each of which is made of 4 layers of rectangular drift cells. 1/14/08, NTU, Taipei The CMS Detector

Quarter view of the CMS Detector 1/14/08, NTU, Taipei The CMS Detector

Layout of a CSC & a Schematic View of a Single Gap HV: 3.5-3.9 kV 7 trapezoidal panels forming a 6 gas gaps. Gas: 40% Ar + 50% CO2 + 10% CF4 1/14/08, NTU, Taipei The CMS Detector

Resistive Plate Chamber Advantage: tagging the ionizing time much shorter than 25ms  good for triggers Gas: 96.2% C2H2F4 + 3.5% C2H10 + 0.3% SF6 1/14/08, NTU, Taipei The CMS Detector

Schematic Layout for Barrel RPC r-f view 1/14/08, NTU, Taipei The CMS Detector

Layout for Endcap RPC 1/14/08, NTU, Taipei The CMS Detector

Expected Performance 1/14/08, NTU, Taipei The CMS Detector

Status of the Muon System DT muons: a. Install tower electronics b. Test and commission 2. CSC a. All chambers and electronics are installed. B. Do more tests. 1/14/08, NTU, Taipei The CMS Detector

Summary After so many year hardwork, majority of the detector and electronics are installed and commissioned. Problems and difficulties are foreseen before collisions. Tight schedule for Endcap ECAL and Preshower. Keep testing and looking forward to LHC physics. 1/14/08, NTU, Taipei The CMS Detector