Basis of the M/EEG signal Evelyne Mercure & Bonnie Breining.

Slides:



Advertisements
Similar presentations
PS4529/30 Applications of Cognitive Neuroscience.
Advertisements

What are we measuring in EEG and MEG? Methods for Dummies 2007 Matthew Longo.
What are we measuring with
What does EEG actually measure?
What are we measuring with M/EEG? Luzia Troebinger.
Basis of the EEG/MEG signal
Basis of the M/EEG Signal
NEUROANATOMY OF LANGUAGE 4 DAY 12 – SEPT 23, 2013 Brain & Language LING NSCI Harry Howard Tulane University.
Chapter 4: Local integration 2: Neural correlates of the BOLD signal
BASIS OF M/EEG SIGNAL Maciej Cosilo Panagiotis Papagiannopoulos.
Electrophysiology. Electroencephalography Electrical potential is usually measured at many sites on the head surface More is sometimes better.
From Neuronal activity to EEG/MEG signals
Basis of the M/EEG signal Jordi Costa Faidella & Tal Machover 1.
What are we measuring with EEG and MEG James Kilner.
Artifact (artefact) reduction in EEG – and a bit of ERP basics CNC, 19 November 2014 Jakob Heinzle Translational Neuromodeling Unit.
Electrophysiology.
We can estimate the time course of the source power from locations which show high activity by applying the beamformer calculated according to (2) or (4).
Electrophysiology. Neurons are Electrical Remember that Neurons have electrically charged membranes they also rapidly discharge and recharge those membranes.
Opportunity to Participate
Subdural Grid Intracranial electrodes typically cannot be used in human studies It is possible to record from the cortical surface Subdural grid on surface.
Experimental Design in fMRI
Electroencephalography The field generated by a patch of cortex can be modeled as a single equivalent dipolar current source with some orientation (assumed.
Electroencephalography and the Event-Related Potential
Electroencephalography Electrical potential is usually measured at many sites on the head surface.
Brain Electrical Source Analysis This is most likely location of dipole Project “Forward Solution” Compare to actual data.
Faraday’s Law  produces an induced current Lenz’s Law: Induced current is in a direction so as to produce a B opposing the change in magnetic flux, 
An introduction to MEG Lecture 1 Matt Brookes.
Neurocognition Cognitive Neuroscience/neuropsychology n All cognition is the result of neurological activity –most closely linked to cerebral cortex The.
Center for Brain and Cognitive Science Mind Reading for Cognitive Systems Yong-Ho Lee Center for Brain & Cognitive Research Korea Research Institute of.
Source Localization for EEG/MEG Stavroula Kousta Martin Chadwick Methods for Dummies 2007.
IMAGING THE MIND Direct methods –Electrical activity (EEG, MEG) –Metabolic activity (EROS) Indirect methods –Changes in regional Cerebral Blood Flow (rCBF)
Closed and Open Electrical Fields
The M/EEG inverse problem and solutions Gareth R. Barnes.
The M/EEG inverse problem and solutions Gareth R. Barnes.
Jeffrey M Politsky, MD FRCP(C) Northeast Regional Epilepsy Group Atlantic Neuroscience institute.
All slides © S. J. Luck, except as indicated in the notes sections of individual slides Slides may be used for nonprofit educational purposes if this copyright.
Ch.1 Introduction to Brain-Computer Interfacing. Overview Fairytales: translating thoughts into actions without acting physically. Recent BCI technologies.
Magnetoencephalography (MEG)

Functional Brain Imaging (cont’d) MEG Ling 411 – 10.
Neuroimaging Methods: Visualising the brain & its injuries Structural (brain structure) –X-rays –CT (Computer Tomography) –MRI (Magnetic Resonance Imaging)
Source localization MfD 2010, 17th Feb 2010
BMI2 SS08 – Class 9 “EEG-MEG 1” Slide 1 Biomedical Imaging 2 Class 9 – Electric and Magnetic Field Imaging: Electroencephalography (EEG), Magnetoencephalography.
Attention Loads program into working memory (more about that later) Vast amount of perceptual information available at one Moment How much can be retained.
Functional Brain Imaging (cont’d) MEG Ling 411 – 10.
STRATEGIES OF COGNITIVE NEUROSCIENCE The Coin of the Realm: correlations between psychological and neurophysiological events/structures Establishing two-way.
Dynamic Causal Modelling of Evoked Responses in EEG/MEG Wellcome Dept. of Imaging Neuroscience University College London Stefan Kiebel.
Cognitive Psychology PSYC231 Cognition and the Brain: Basic Principles 2 Dr. Jan Lauwereyns, EA619, ext
Neuroimaging Methods: Visualising the brain & its injuries Structural (brain structure) –X-rays –CT (Computer Tomography) –MRI (Magnetic Resonance Imaging)
Phrenology Wrong!. Outer Surface of Human Brain Gray Matter = Neuron cell bodies & dendrites White Matter = Myelin (=fat)- covered axons Cortex = Outer.
Electroencephalography Collecting and Analyzing Data: 101
Magnetoencephalography Matt Martin 09/17/2004 APPM 4380.
K. Gireesan1, T. S. Radhakrishnan1, Joseph Bensigh3, S
Chapter 2 Cognitive Neuroscience. Some Questions to Consider What is cognitive neuroscience, and why is it necessary? How is information transmitted from.
Chapter 2 Cognitive Neuroscience. Some Questions to Consider What is cognitive neuroscience, and why is it necessary? How is information transmitted from.
Electrophysiology. Neurons are Electrical Remember that Neurons have electrically charged membranes they also rapidly discharge and recharge those membranes.
Magnetoencephalography (MEG) and its role
How can we study the brain?
EEG Definitions EEG1: electroencephalogram—i.e., the “data”
Cortex Sept 22, 2017 – DAY 11 Brain & Language
Cycle 4 Methods Electrical Signals Dendritic membrane potentials
What are we measuring with M/EEG?
Basis of the MEG/EEG Signal
EEG and MEG: Relevance to Neuroscience
Comparison of imaging techniques
Basis of the MEG/EEG Signal
MEG fundamentals.
M/EEG Statistical Analysis & Source Localization
Brain imaging research
Synaptic Transmission and Integration
Presentation transcript:

Basis of the M/EEG signal Evelyne Mercure & Bonnie Breining

Plan Overview of EEG & ERP Overview of EEG & ERP Overview of MEG Overview of MEG Comparisons Comparisons EEG vs. MEG EEG vs. MEG EEG/MEG vs. Other Imaging Techniques EEG/MEG vs. Other Imaging Techniques

Electroencephalography 1929: Hans Berger discovered that an electrode applied to the human scalp could record voltage variations attributed to the activity of the neurons 1929: Hans Berger discovered that an electrode applied to the human scalp could record voltage variations attributed to the activity of the neurons Amplified, plotted as a function of time => EEG signal Amplified, plotted as a function of time => EEG signal

The EEG signal

EEG rhythms

Action potential When a neuron is activated, current flows from the cell body to the axon terminal When a neuron is activated, current flows from the cell body to the axon terminal To be registered by electrodes on the scalp many neurons would need to fire at the same time, which is unlikely given that action potentials lasts around 1msec To be registered by electrodes on the scalp many neurons would need to fire at the same time, which is unlikely given that action potentials lasts around 1msec No dipole created No dipole created Not recorded by EEG!!! Not recorded by EEG!!!

Postsynaptic potentials After an action potential neurotransmitters are released After an action potential neurotransmitters are released They bind to the receptors of a postsynaptic neuron They bind to the receptors of a postsynaptic neuron

Postsynaptic potential (2) Depending on whether the neurotransmitter is excitatory or inhibitory, electrical current flows from the postsynaptic cell to the environment, or the opposite Depending on whether the neurotransmitter is excitatory or inhibitory, electrical current flows from the postsynaptic cell to the environment, or the opposite The membrane of the postsynaptic cell becomes depolarised (more likely to generate an action potential) or hyperpolarised (less likely to generate an action potential) The membrane of the postsynaptic cell becomes depolarised (more likely to generate an action potential) or hyperpolarised (less likely to generate an action potential)

Postsynaptic potential (3) Electrical current begins to flow in the opposite direction within the cell body to complete the electrical circuit Electrical current begins to flow in the opposite direction within the cell body to complete the electrical circuit A small dipole is created! A small dipole is created! Lasts tens or even hundreds of milliseconds => more likely to happen simultaneously Lasts tens or even hundreds of milliseconds => more likely to happen simultaneously To sum together, postsynaptic potentials of different neurons need to To sum together, postsynaptic potentials of different neurons need to Be simultaneous Be simultaneous Be spatially aligned Be spatially aligned + -

Pyramidal neurons of the cortex are spatially aligned and perpendicular to the cortical surface Pyramidal neurons of the cortex are spatially aligned and perpendicular to the cortical surface The EEG signal results mainly from the postsynaptic activity of the pyramidal neurons The EEG signal results mainly from the postsynaptic activity of the pyramidal neurons

Volume conduction When a dipole is in a conductive medium, electrical current spreads through this medium When a dipole is in a conductive medium, electrical current spreads through this medium The skull has a higher electrical resistance than the brain => the electrical signal spreads laterally when reaching the skull The skull has a higher electrical resistance than the brain => the electrical signal spreads laterally when reaching the skull Difficulty of source localisation Difficulty of source localisation

Recording EEG Electrode applied to the skull or brain surface Electrode applied to the skull or brain surface Substance with low impedance is used to conduct electricity between the skin and electrode Substance with low impedance is used to conduct electricity between the skin and electrode Voltage is a difference in electrical potential => need a reference point! Voltage is a difference in electrical potential => need a reference point!

Artefacts Muscle movements Muscle movements Eye movements Eye movements Blinks Blinks Sweating Sweating  Many trials  Artefact rejection

Event-related potentials A different way of analysing the EEG signal A different way of analysing the EEG signal Time-locked to a stimulus Time-locked to a stimulus 

Event-related potentials (2) Averaging Averaging ERP components ERP components P1 => N170 => P2 =>

Magnetoencephalography (MEG)

Electricity & Magnetism MEG measures the same postsynaptic potentials as EEG. Basic Physics: Electric currents have corresponding magnetic fields. The magnetic field generated is perpendicular to the electric current. Right Hand Rule

Electricity & Magnetism 2: Electricity & Magnetism 2: MEG is sensitive to tangential but not radial components of signal MEG mainly measures the activity of pyramidal neurons in the sulci that are oriented parallel to the scalp Magnetic fields from perpendicular oriented neurons on gyri don’t project out of head

Magnetic Fields Magnetic fields generated by brain activity are tiny 100 million times smaller than the earth's magnetic field 1 million times smaller than the magnetic fields produced in an urban environment (by cars, elevators, radiowaves, electrical equipment, etc) MEG must be performed in shielded rooms

A Bit of History In 1963 Gerhard Baule and Richard McFee of the Department of Electrical Engineering,Syracuse University, Syracuse, NY detected the biomagnetic field projected from the human heart. They used two coils, each with 2 million turns of wire, connected to a sensitive amplifier. The magnetic flux from the heart generated a current in the wire. They did this in a field in the middle of nowhere because of the very noisy signal.

More History In the late 1960’s David Cohen, at MIT, Boston recorded a clean MCG in an urban environment. This was possible due to: 1) Magnetically shielding the recording room. 2) Improved recording sensitivity. (The introduction of SQUIDS)

Equipment SQUIDs- Superconducting QUantum Interference Devices Use principles of super-conduction to measure tiny magnetic fields 300+ sensors in helmet shape Cool with liquid helium SQUIDs Sensors SQUID

Magnetometers First Order Gradiometer The sensitivity of the SQUID to magnetic fields may be enhanced by coupling it to a superconducting pickup coil (“flux transformer”) which: has greater area and number of turns than the SQUID inductor alone. made of superconducting wire and is sensitive to very small changes in the magnitude of the impinging magnetic flux. The magnetic fields from the brain causes a supercurrent to flow.

MEG data brain activation film (recorded during comprehension of a spoken word)

EEG vs. MEG Good temporal resolution ( ~1 ms) Problematic spatial resolution (forward & inverse problems) Cheap Large Signal (10 mV) Signal distorted by skull/scalp Spatial localization ~1cm Sensitive to tangential and radial dipoles (neurons in sulci & on gyri) Allows subjects to move Sensors attached directly to head Extracellular secondary (volume) currents Expensive Tiny Signal(10 fT) Signal unaffected by skull/scalp Spatial localization ~1 mm Sensitive only to tangential dipoles (neurons in sulci) Subjects must remain still Sensors in helmet Requires special laboratory Intracellular primary currents’ magnetic fields EEGMEG Thanks to last year’s slides & wikipedia

MEG/EEG vs. Other Techniques rationalist.eu/Images/introfig4.jpg

Advantages of EEG/ERPs/MEG Non-invasive (records electromagnetic activity, does not modify it) Non-invasive (records electromagnetic activity, does not modify it) Can be used with adults, children, infants, newborns, clinical population Can be used with adults, children, infants, newborns, clinical population High temporal resolution (a few milliseconds, around 1000x better than fMRI) => ERPs study dynamic aspects of cognition High temporal resolution (a few milliseconds, around 1000x better than fMRI) => ERPs study dynamic aspects of cognition EEG relatively cheap compared to MRI EEG relatively cheap compared to MRI Allow quiet environments Allow quiet environments Subjects can perform tasks sitting up- more natural than in MRI Subjects can perform tasks sitting up- more natural than in MRI

Limitations of EEG/ERPs/MEG Spatial resolution is fundamentally undetermined Spatial resolution is fundamentally undetermined Signal picked up at one place on the skull does not represent the activity directly under it Signal picked up at one place on the skull does not represent the activity directly under it Forward problem: Knowing where the dipoles are and the distribution of the conduction in the brain, we could calculate the voltage variation recorded at one point of the surface Forward problem: Knowing where the dipoles are and the distribution of the conduction in the brain, we could calculate the voltage variation recorded at one point of the surface Inverse problem: Infinite number of solutions Inverse problem: Infinite number of solutions Source localisation algorithms uses sets of predefined constraints to limit the number of possible solutions Source localisation algorithms uses sets of predefined constraints to limit the number of possible solutions Anatomical information not provided Anatomical information not provided

References/suggested reading Handy, T. C. (2005). Event-related potentials. A methods handbook. Cambridge, MA: The MIT Press. Luck, S. J. (2005). An introduction to the event-related potential technique. Cambridge, Massachussets: The MIT Press Rugg, M. D., & Coles, M. G. H. (1995). Electrophysiology of mind: Event-related brain potentials and cognition. New York, NY: Oxford University Press. Hamalainen, M., Hari, R., Ilmoniemi, J., Knuutila, J. & Lounasmaa, O.V. (1993). MEG: Theory, Instrumentation and Applications to Noninvasive Studies of the Working Human Brain. Rev. Mod. Phys. Vol. 65, No. 2, pp Sylvain Baillet, John C. Mosher & Richard M. Leahy (2001). Electromagnetic Brain Mapping. IEEE Signal Processing Magazine. Vol.18, No 6, pp Basic MEG info: