Scanning Electron Microscope (SEM)

Slides:



Advertisements
Similar presentations
Ge 116 Module 1: Scanning Electron Microscopy
Advertisements

Basic Electron Microscopy
BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
SEM & TEM in Polymer Characterization
BY Assistant Professor Dr. Akram R. Jabur Department of Materials Eng. University Of Technology.
Electron Optics.
Electron-Specimen Interactions
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Hong Koh Yiin -CAMTEC Image from:
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
Components of Initial Eprobe Startup Electron Gun –turning on beam, setting beam current, acceleration, saturation level Focusing lenses –Permit focussed.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
Electron Optics Two essential components: 1)Electron source (gun) 2)Focusing system (lenses) Add scanning apparatus for imaging Electron gun Cathode Anode.
Electron-Specimen Interactions
Electron Microscope. Light Resolution  The resolution of a microscope is limited by the diffraction of light. Single diffractionSingle diffraction 
CHAPTER 8 (Chapter 11 in text) Characterization of Nanomaterials.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Scanning Electron Microscope د. عمر عبد القادر.
Surface Emissions Specimen current X-rays Cathodoluminescence Pole Piece, etc SE3  ≈ 1 nm for metals up to 10 nm for insulators.
FYSZ460 Electron Beam Lithography Electron Beam Lithography FYSZ460 Advanced Laboratory Exercise Mikko Palosaari
Introduction to scanning electron microscopy
Transmission Electron Microscopy
SEM microscope By: Doug, Holly & Oleg. Scanning Electron Microscope vs. Optical Microscope Advantages Continuously variable magnification High resolution.
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Electron Microscopy.
Scanning Electron Microscopy
Introduction to transmission electron microscopy
B. Spatial coherancy & source size Spetial coherancy is related to the size of the source. Source size governs spatial coherancy and maller source sizes.
SEM (SCANNING ELECTRON MICROSCOPE) Özgen Buğdaycı Elif Topçuoğlu Yavuz Duran Hacettepe University
Scanning Electron Microscope (SEM) – Shoots a high energy beam of electrons (waves of electrons) at a target. Electron gun Focusing coil Objective lens.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
Scanning Electron Microscope (SEM)
Other modes associated with SEM: EBIC
Scanning Electron Microscope
Scanning Electron Microscope (SEM)
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Proximity Effect in Electron Beam Lithography
NANO 230 Micro/Nano Characterization
Scanning capacitance microscopy
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Characterization of Nanomaterials…
08/03/09 SEM signal generation
SEM Scanning Electron Microscope
The Microscopes. The Microscope 1. The microscope is an optical instrument that uses a lens or combination of lenses to magnify and resolve the fine details.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Types of Electron Microscopes Electron microscopes use a beam of electrons rather than visible light to illuminate the sample. They focus the electron.
Scanning Transmission Electron Microscope
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
THE ELECTRON MICROSCOPE. Introduction.
SEM Imaging - Magnification and Deflection System
Scanning Electron Microscope Eee-Jay Rodriguez. The Structure of the Microscope Inside Outside.
BY GAJENDRA KUMAR ID- 2011uit1721. WHAT IS SEM  It is a microscope that uses a focused electron probe to extract structural and chemical information.
Introduction to scanning electron microscopy
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Introduction to scanning electron microscopy
Laboratory equipment Lecture (3).
Introduction to Scanning Electron Microscope by Sameer S
METALLURGICAL MICROSCOPE
X-ray Production Sharif Qatarneh Medical Physics Division
NANO 230 Micro/NanoFabrication
TEM and SEM.
Topic 1: Introduction to Histology
Do it with electrons !.
Electronics and Instrumentation Vidnyan Mahavidyalaya, Sangola.
SEM Imaging - Magnification and Deflection System
Scanning Electron Microscopy (SEM)
Presentation transcript:

Scanning Electron Microscope (SEM) Major components: Vacuum system Electron beam generation system Electron beam manipulation system Beam specimen interaction system Detection system Signal processing system Display and recording system SEM operation principles: http://www.youtube.com/watch?v=PNHn4YM7yfc&feature=related SEM introduction http://www.youtube.com/watch?v=c7EVTnVHN-s&feature=related

Vacuum system Low vacuum pump (<10-3 Torr) (remove 99.99% of air), high vacuum pump(>10-3 Torr) SEM operation need 10-4 to 10-6 Torr

E beam generation Three components: 1) cathode (filament or field emission) 2) grid cap that control the flow of electrons 3) anode that attracts and accelerates electrons Voltage ranges from 0.1 to 40 Kv, (10kV the most common for biological specimen) the higher the voltage the better the resoution (but greater heat will be generated on the specimen) On/off switch for high voltage (HV) Beam current (the flow of electrons that hit a sample), controlled by bias voltage between filament and grip cap, Increasing beam current results in deeper penetration of electron and a larger diameter spot) Filament current control (adjustment of current filament, providing necessary heating current to filament) Filed emission: advantages: cool cathode, emitted beam is smaller in diameter (better resolution), longer life time disadvantages: higher vacuum need (~10-7 Torr), cleaner microscope needed, not many x-rays generated (due to low beam currents and small beam diameters)

E beam manipulation E-gun is controlled by electrostatic field, while the rest of SEM is controlled by magnetic lenses. Electromagnetic lenses: - condenser lenses: reduce spot size spherical aberration limit resolution - correct astigmatism (non-circular beam spot), due to beam formed by filament is elliptical, dirt in column, beam distorted on the aperture using stigmator (control strength and azimuth) - correct alignment - two sets of magnetic coils (raster coils) that move the seam scanning in the X and Y direction - magnification: ratio of dimension of CRT to dimension of the area being scanned two ways of magnification adjustments: 1) change scanned area of the specimen 2) adjust focal point of the beam and working distance (move Z-axis to bring sample to focal point) Aperture: a round hole that control the passing through of scattered electrons - small aperture for high resolution - big aperture for low resolution with more electrons needed

Beam interaction Backscattered electrons: original beam electrons, high energy level, useful when relative atomic density information with topographical information is displayed Secondary electrons: generated by dislodging specimen e or other secondary e a few eV, detected near the surface, can obtain topographical and high solution, contrast and soft shadows of image resemble specimen illuminated with light X-rays: can obtain elemental information (from wavelength and energy characteristic of elements) measurement of wavelength (wavelength dispersive spectrometer (WDS)) or energy level (energy dispersive spectrometer (EDS)) wavelength range: 10 ~ 0.01 nm (3x1016 ~ 3x1019 Hz), soft x-ray:0.12ev~12 keV, hard x-ray:12kev~120 keV, http://www.lbl.gov/MicroWorlds/ALSTool/EMSpec/EMSpec2.html http://www.physics.isu.edu/radinf/xray.htm

Cathode Luminescence: specimen molecule’s florescence that produces light photon Specimen current: e energy decreases after scattering and e absorbed by sample can build up negative charge and lead to charging Transmitted electrons: primary e pass through specimen provide atomic density information displayed as a shadow higher the atomic number the darker the shadow