Prof. of Clinical Chemistry, Mansoura University.

Slides:



Advertisements
Similar presentations
Analytical Performance of the APTIMA HPV Assay on the PANTHER Analyzer
Advertisements

By Gracie Canales August 10, 2010
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez
Pharos university Faculty of Allied Medical SCIENCE Clinical Laboratory Instrumentation (MELI-201) Dr. Tarek El Sewedy.
Visuals, Spellings, and Uses The Right tool for the job!
1 Lecture: Forensic Serology - Immunoassays Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers to an immune.
Part Three Basic Test Methods
Droplet digital PCR Overview and applications
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Automated Methods of Analysis
Quality Assurance.
QUANTITATIVE ANALYSIS & BASIC TOOLS MISS NOORULNAJWA DIYANA YAACOB School of Bioprocess Engineering University Malaysia Perlis 02600, Kangar Perlis
Radioimmunoassay & Enzyme Linked Immunosorbent Assay
P RINCIPLES OF C LINICAL C HEMISTRY A UTOMATION. A UTOMATION I N C LINICAL C HEMISTRY The modern clinical chemistry laboratory uses a high degree of automation.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Unit 1: Chemistry Basics
COBAS AmpliPrep/Cobas TaqMan HIV-1 Test
Quality Assurance.
Atomic Emission Spectroscopy
Method Selection and Evaluation Method Selection and Evaluation D. Kefaya EL- Sayed Mohamed Prof. Of Clinical Pathology (Clinical Chemistry), Mansoura.
Double Beam spectrometer Provides a signal that is largely free of drift in the source and detector without requiring really expensive components Beam.
Enzyme-Linked Immunosorbent Assay
PAS-Intro1 Dated 24th Aug Copyright © Siemens AG 1999 All Rights Reserved Siemens Advanced Engineering Pte Ltd Process Analytical Services Division.
AUTOANALYZER T. Elsarnagawy 22/12/ Elsarnagawy, MASH
Analytical chemistry MLAB 243 Level 4 Lecture time: every WED 8 -10
3 Laboratory Automation.
An Introduction to Medicinal Chemistry 3/e COMBINATORIAL CHEMISTRY
RADIO IMMUNOASSAY DANIEL CASAL.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Errors Requesting appropriate tests Writing prescription Reading prescription Sample collection Sampling times environmental factors Drug interferences.
Quality Control Lecture 5
HCV PCR By Henrietta Orji July 31 st, 2010 Hepatitis C Virus by Polymerase Chain Reaction.
Definitions  Antibodies (also known as immunoglobulins abbreviated Ig) are gamma globulin proteins that are found in blood and are used by the immune.
Combinatorial Chemistry Advanced Medicinal Chemistry (Pharm 5219): Section A Ref.: An Introduction to Medicinal Chemistry, 3 rd ed. 2005, G.L.Patrick,
1 Immunoassay Testing Forensic Toxicology. 2 Introduction Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers.
Chemiluminescence. Luminescence Definition Luminescence is emission of light by a substance not resulting from heat Types of luminescence Fluorescence.
1 ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY ALINA RAHAYU MOHAMED School of Bioprocess Engineering University Malaysia Perlis 02600, Kangar.
Quality Assurance How do you know your results are correct? How confident are you?
P RINCIPLES OF C LINICAL C HEMISTRY A UTOMATION. A UTOMATION I N C LINICAL C HEMISTRY The modern clinical chemistry laboratory uses a high degree of automation.
Principles of Clinical Chemistry Automation
HPLC – High Performance Liquid Chromatography
Visuals, Spellings, and Uses The Right tool for the job!
Radioimmuno assay. Immunoassay reactions may be competitive or non-competitive  Competitive labeled known and patient unknown are added to reaction and.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Biochemical instrumental analysis-14
L ABORATORY Q UALITY C ONTROL. INTRODUCTION _A major role of the clinical laboratory is the measurement of substances in body fluids or tissues for the.
Prof. Moustafa M. Mohamed
CLINICAL CHEMISTRY Introduction to basic clinical chemistry BY BRUCE MUTUA.
Enzymatic analyses on wine By Wernich Kühn Central Analytical Facility Stellenbosch University.
ELISA Enzyme Linked Immunosorbent Assay Fariba mazrouei.
CLINICAL CHEMISTRY AUTO-ANALYZERS
Chapter 1: The Nature of Analytical Chemistry
QUANTITATIVE ANALYTICAL CHEMISTRY PRACTICES
Laboratory Quality Control
UV/VIS SPECTROSCOPY.
Introduction to Basic Clinical Chemistry
Chemiluminecent microparticle)) immunoassay
Chemiluminecent microparticle MEIA)) immunoassay
Medical Electronics - K.Srinivasamoorthi
College of Veterinary Medicine
Labeled Immunoassays.
دکتر جعفر علاوی طوسی، متخصص پاتولوژی
Quality Assurance in the clinical laboratory
RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY.
Practical clinical chemistry
Elsarnagawy, MASH Autoanalyzer T. Elsarnagawy 22/12/1432.
Automated Methods of Analysis
Quality Control Lecture 3
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Presentation transcript:

Prof. of Clinical Chemistry, Mansoura University

Implies a self – regulating process with an element of feed-back which detect any tendency to malfunction and readjusts the equipment so that it continues to function correctly.

Definitions and processing concepts: Continuous flow analyser: The reagent are pumped continuously by syring pump The samples are introduced at regular intervals The flow is segmented to separate one specimen from anothor This type is used as batch analyzer e.g technicon. Two types : a)single channel continuous flow: analyse one constituent in each specimen. b)Multichannel continuous flow: determination of several components in each sample

Discrete analyser: Samples are processed in separate reaction tubes. The instrument contain a variety of receptacle in which the sample and reagents are mixed. The reaction occurs: cuvettes, dry film slides. Some containers contain the reagents and only the specimen need to be added. Others add both reagents and specimen.

Reaction vessels and cuvets in discretes: Reused or discarded Used as cuvet or just reaction tube, aspirated in tube then to another tube for measurement For wash reused reaction vesseles or cuvets aspiration of the reaction mixture a detergent,alkaline or acid wash soln. is then dispensed into and aspirated out of the cuvets

Parallel analysis: All specimens are subjected to a series of analytical processes at the same time in a parallel fashion:  Discretionary multiple – channel analysis.  The specimen can be analyzed by any one or by more than one of the available processes (methods, channels).

- A number of specimens are processed in the same analytical session, or run:  Batch analyzer.

The components steps in automated system 1.Specimen identification. 2.Specimen preparation. 3.Specimen handling, transport and delivery. 4.Specimen processing. 5.Sample transport and delivery. 6.Reagent handling and storage. 7.Reagent delivery. 8.Chemical reaction phase. 9.Measurement approach. 10.Signal processing data handling and process control. These operations are usually performed sequentially but in some instrument, they may be combined and occur in parallel.

Specimen identification:

Specimen Preparation:

Specimen Handling, Transport and Delivery:

Specimen processing:

Sample transport and delivery: In continuous – flow system: the sample is aspirated through the sample probe into continuous reagent stream In Discrete analyzers: the sample is aspirated into sample probe and delivered, with reagent into reaction tube or cup.

Carry over: Carry over occurs when a previous sample or reagent contaminates successive tests in a run causing the next sample to have an aberrantly higher or lower results. Carry over occurs when anlytes occur in extremely high levels e.g. enzyme or h CG in pregnancy Carry over also occurs in systems that reuse cuvettes that are insufficiently washed after each testing cycle. In discrete systems with disposable reaction vessels and measuring cuvettes carry over is caused by the pipeting system

Disadv: one analyte per rotor but now recent models allow multiple analysis 24 rotors can be loaded at one time. In Continuous flow: by glass coils passing through the samples and reagents.

Measurement approaches: Spectrophotometry Fluorimetry e.g. IMX Chemiluminescenc e.g. IMMULITE Electrochemical for electrolytes

Examples:

Automated immunoassay systems differ from chemical analyzers in that they require the use of: 1.solid – phase reagents to separate bound and unbound 2.More sensitive detection methods e.g fluorescence and chemiluminescence 3.Special handling of the reagents: e.g. 1.Thermal conditioning to keep chemilum substrate stable. 2.Constant agitation to keep microparticles suspended.

4-Multiple Calibrators: (upto 6) Calibration usually nonlinear Example : ACS : 180 benchtop R-A Imm. AS.S ay IMMULITE : bench – top R-A Imm. Assay Automated immunoassay

Selection of instruments Role of an automated system in the workflow of the laboratory. Identification of candidate system (RA or batch). Cost effectiveness of the system. User-friendiness (interface between the machine and the human operator). Analytical performance.

Advantages of automation: Large number of samples may be processed with minimal technician. Two or more methods may be performed simultaneously. precision is superior to that of manual performance. calculations may not be required.

Disadvantages of automation: limitation of the methodology "closed system". Expensive. Many systems, are impractical to use for small numbers of samples. Therefore, back up manual methods may be required for individual emergency analysis. Back up methods must also be available in the event of instrumental failures.