Electron-Specimen Interactions

Slides:



Advertisements
Similar presentations
Microscopy Do you want a footer?.
Advertisements

BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
Introduction to Electron Microscopy
SEM & TEM in Polymer Characterization
BY Assistant Professor Dr. Akram R. Jabur Department of Materials Eng. University Of Technology.
Scanning Electron Microscope (SEM)
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Effect of Accelerating Voltage on Resolution
Basic Table-top SEM imaging
Radiation Detectors / Particle Detectors
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
X-radiation. X-rays are part of the electromagnetic spectrum. X-radiation (composed of X-rays) is a form of electromagnetic radiation. X- rays have a.
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
Electron-Specimen Interactions
Lecture 5.1 Scanning Electron Microscopy (SEM)
CHAPTER 8 (Chapter 11 in text) Characterization of Nanomaterials.
Lab meetings Week of 6 October
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Scanning Electron Microscope د. عمر عبد القادر.
Surface Emissions Specimen current X-rays Cathodoluminescence Pole Piece, etc SE3  ≈ 1 nm for metals up to 10 nm for insulators.
Introduction to scanning electron microscopy
SEM microscope By: Doug, Holly & Oleg. Scanning Electron Microscope vs. Optical Microscope Advantages Continuously variable magnification High resolution.
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
LECTURE 5 Principles of Electron Microscopy (SEM and TEM)
Microscope.
Scanning Electron Microscopy
Microanalysis in Science and Engineering - Electron Microscopy A Workshop for Middle and High School Teachers sponsored by Tennessee Technological University.
SEM (SCANNING ELECTRON MICROSCOPE) Özgen Buğdaycı Elif Topçuoğlu Yavuz Duran Hacettepe University
Biology 3.1 Looking at Cells.
LIGHT.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
1 Components of Optical Instruments Lecture Silicon Diode Transducers A semiconductor material like silicon can be doped by an element of group.
Scanning Electron Microscope (SEM)
Scanning Electron Microscope (SEM)
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
CAMTECH 2011 Regi. High energy e - beam scans sample surface (Raster - line by line). Provides information about surface and near-surface atoms – topography.
NANO 230 Micro/Nano Characterization
Scanning capacitance microscopy
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
Conventional SEM Specimen at high vacuum – requires sample fixation and dehydration or freezing. Charging is minimized by coating sample with metal or.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Characterization of Nanomaterials…
08/03/09 SEM signal generation
SEM Scanning Electron Microscope
The Microscope and Forensic Identification. Magnification of Images A microscope is an optical instrument that uses a lens or a combination of lenses.
The Microscopes. The Microscope 1. The microscope is an optical instrument that uses a lens or combination of lenses to magnify and resolve the fine details.
Chapter V Radiation Detectors.
SARDAR PATEL INSTITUTE OF TECHNOLOGY E.NO : Guide By:- V.N.Thakkar.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Microscopes A short course. Background Information There is certain terminology used when discussing microscopes. Magnification refers to the ratio of.
Scanning Transmission Electron Microscope
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Patient is placed between X-ray tube and silver halide film.
Scanning Electron Microscope Eee-Jay Rodriguez. The Structure of the Microscope Inside Outside.
Spatial Resolution and minimum detection
Introduction to scanning electron microscopy
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
Introduction to scanning electron microscopy
Laboratory equipment Lecture (3).
Introduction to Scanning Electron Microscope by Sameer S
NANO 230 Micro/NanoFabrication
TEM and SEM.
The Microscopes.
Scintillation Counter
Do it with electrons !.
Electronics and Instrumentation Vidnyan Mahavidyalaya, Sangola.
전자와 시편의 상호작용(비탄성산란) 2θ Incident Beam (Primary electron)
Presentation transcript:

Electron-Specimen Interactions

SEM Setup Electron/Specimen Interactions Incident Beam Specimen When the electron beam strikes a sample, both photon and electron signals are emitted. Incident Beam Primary backscattered electrons X-rays Through thickness composition info Atomic number and topographical Cathodoluminescence Electrical Secondary electrons Auger electrons Surface sensitive compositional Topographical Specimen Specimen Current Electrical

Primary Signals: Secondary Electrons Backscattered Electrons X-rays

The size and shape of the region of primary excitation can be estimated by carrying out simulations that use Monte Carlo calculations and take into account the composition of the specimen

An interaction volume can also be used to predict the types of signals that will be produced and the depth from which they can escape. Monte Carlo simulations of electron trajectories are based on 1) the energy of the primary beam electron, 2) the likelihood of an interaction, 3) the change in direction and energy of the electron, 4) the mean free path of the electron and 5) a “random” factor for any given interaction.

Electron Flight Simulator http://www.small-world.net/efs.htm

Actual image of beam penetration into PMMA showing size and dimension of region of primary excitation

The angle at which the beam strikes the specimen and the distance from the surface are important factors in how much of signal escapes from the specimen.

Sometimes one can take advantage of the this effect and increase useable signal by tilting the specimen towards the detector and at an angle relative to the primary beam

The probability of an elastic vs The probability of an elastic vs. an inelastic collision is based primarily on the atomic weight of the specimen.

Secondary electron < 50 eV Backscatter electron >80% of primary electron energy X-ray 0.5 – 20 KeV

Auger Electrons Low energy electrons emitted from the upper 2-3nm of the surface and contains information about the element that produced it based on its energy

An Auger spectrum for Aluminum showing peaks for different electron replacement events

Secondary electrons are usually the result of an inelastic collision in which the transferred energy of the primary beam is transferred to an electron that is then emitted from the atom. Secondary electrons typically have an energy of 50 eV or less.

Although secondary electrons are produced throughout the interaction region they can only escape from the uppermost portion due their low energy

Backscattered electrons are the result of elastic collisions with atoms of the specimen. They result in emitted electrons that have an energy of 80% or more of the original energy of the primary beam electron

Backscattered electrons are also produced throughout the interaction region but because of their greater energy can escape from deeper in the specimen.

X-rays are indirectly produced when an electron is displaced through a collision with a primary beam electron and is replaced by another electron. The resultant loss of energy is given off in the form of an X-ray. The energy will always be less than the energy of the primary beam electron.

Because of their high energy X-rays can escape from very deep in the specimen.

Resolution in an SEM is ultimately determined by the size of the region from which signal is produced. Thus for the same region of excitation the resolution from the three signals differs and decreases from secondary to backscatter to X-rays.

Factors affecting size of the interaction region: Diameter of the primary beam Energy of the primary beam Atomic weight of the specimen Coating of specimen

Final primary beam probe size from a field emitter is 10-100X smaller than that of a conventional tungsten filament or LaB6 emitter. This is one reason why FESEMs have the best image resolution.

FESEMs also tend to remain stable at very low accelerating voltages (0 FESEMs also tend to remain stable at very low accelerating voltages (0.5 – 5 KeV) resulting in shallow regions of excitation and thus higher image resolution.

Effects of Accelerating Voltage Z = Atomic Weight E = Energy of primary beam

3.0 KeV 20.0 KeV Effects of Accelerating Voltage More signal (brighter)

3.0 KeV 20.0 KeV Effects of Accelerating Voltage But reduced resolution

Sputtered Gold Chromium Mycoplasma pneumonia Effects of Coating Sputtered Gold Chromium Mycoplasma pneumonia

The relationship of accelerating voltage (Eo) to atomic weight (Z) of the specimen and its affect on the depth of penetration can be summarized as above.

If the region of excitation remains small then signal will be produced from a small region and there will be no overlapping from adjacent regions. In this case each individual spot is resolved from its neighbors.

If the beam is scanned in exactly the same positions but the region of excitation is larger then the regions of signal production will also be larger and overlap with adjacent ones. Such an image would therefore not be resolved.

Even a slight increase in size of the region of signal production can result in decreased resolution.

Overlapping of signal production is also the primary reason why it is so critical to have the beam of an SEM properly stigmated. Even if the size of the region is kept small, it is only those regions which are perfectly circular that will produce the best resolution

Astigmatic regions may not reduce image resolution in one dimension.

But can still reduce resolution by overlapping with adjacent regions.

The position of the secondary electron detector also affects signal collection and shadow. An in-lens detector within the column is more efficient at collecting secondary electrons that are generated close to the final lens (i.e. short working distance).

Secondary Electron Detector Side Mounted In-Lens

A conventional secondary electron detector is positioned off to the side of the specimen. A faraday cage (kept at a positive bias) draws in the low energy secondary electrons. The electrons are then accelerated towards a scintillator which is kept at a very high bias in order to accelerate them into the phosphor.

The Everhart-Thornley detector has an aluminum coating (+10-12 KeV) that also serves to reflect the photons back down the light pipe.

The scintillator is a phosphor crystal that absorbs an electron and generates a photon

The photons produced in the scintillator are carried down a fiber optic light pipe out of the microscope.

Most of the secondary electron detector lies outside of the SEM chamber and is based on a photomultiplier tube (PMT)

A PMT works by converting the incoming photons into electrons which are then drawn to dynodes kept at a positive bias. The dynodes are made of material with a low work function and thus give up excess electrons for every electron that strikes them. The result “multiplies” the signal contained in each photon produced by the scintillator.

The electronic signal from the PMT is further increased by a signal amplifier. Thus an increase in “gain” is accomplished by voltage applied to the dynodes of the PMT and alters the contrast of the image. An increase in the “black” level is made by increasing the current in the amplifier and alters the brightness of the image. Signal is thus increased at the scintillator, PMT, and amplifier.

An in-lens detector does not use a faraday collector as this would affect the primary beam electrons but instead depends on the natural trajectory of the secondary electrons to strike it. It takes advantage of the focusing action of the lens to bring these electrons to cross over and then spread out to strike the annular detector.

Environmental electrons are a form of secondary electrons that are produced via interactions of secondary electrons produced by the specimen that strike gas molecules in the chamber, thus amplifying the signal.

Movie of melting sample in ESEM An environmental SEM or ESEM actually requires gas of some sort (usually water vapor) to create the signal and can operate at elevated pressures as high as 1 x 10 Torr

The ESEM uses a special detector

Backscatter electrons have a greater energy and can escape from deeper within the specimen than can secondary electrons but because they are more readily produced by high atomic weight elements they can be used to visualize differences in elemental composition

2o BS Blood cells with nuclei stained with a silver compound are visible in backscatter mode even though they are beneath the surface of the cell membrane

Since backscattered electrons have a high energy they cannot be collected by way of a faraday cage or other device

The most common design is a four quadrant solid state detector that is positioned directly above the specimen

Gold particles on E. coli appear as bright white dots due to the higher percentage of backscattered electrons compared to the low atomic weight elements in the specimen

Backscatter image of Nickel in a leaf

The topography of the specimen will also affect the amount of backscatter signal and so backscatter imaging is often carried out on flat polished samples

Backscatter image of a composite (polished cement fragment) in which low atomic weight particles appear dark and high atomic weight particles are white.