Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Slides:



Advertisements
Similar presentations
High performance; from 1 metric ton to 100 metric tons instant purification facility per hour, 2400tons per day Low energy consumption (25 kw/h – 38 kw/h)
Advertisements

PowerPoint ® Presentation Chapter 3 Contaminants Poor Indoor Air Quality Effects of Poor Indoor Air Quality Particles Asbestos Lead Gases Carbon Dioxide.
The I 2 Air Fluid Protocol; The Eco-friendly method for eliminating bio-fouling in heat exchangers and cooling towers utilizing I 2 infused mixed media.
Jason Holland Permian Production Equipment, Inc. Welding, Cutting and Brazing Safety.
Water Pollution Thirsty?.
Heat Recovery for Commercial Buildings
Industrial Wastewater treatment solutions Wastewater treatment is simple and easy..
Section #1: What Causes Air Pollution
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
What is a Cooling Tower? Building Equipment Using Cold Water Cooling Tower Make-up Water HOT COLD AIR Cooling Tower Water Treatment Going Green! No Chemicals!
Surface Water Treatment Plant
Environmental Resources Unit C Animal Wildlife Management.
1 Environment Engineering I Dr. Amal Hudhud Dr. Abdel Fattah Hasan An-Najah National University Civil Engineering Department Air Pollution Chapter Eleven-
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
1. Clifton WWTP Polarized Oxygen Air Ionization ( ► Oxidizes air borne VOCs and chemicals ► Kills bacteria and sterilizes the air ►
Wetlands for Acid Mine and Livestock Drainage Treatment By: Gabe Jenkins April 18 th 2005.
Society depends on clean and safe water.
Section 1: What Causes Air Pollution?
Air Cleaning Devices. 2 Is An Air Cleaner Needed ?  Toxicity of materials discharged  Amount of material to be discharged  Value of material to be.
Richard Simmons Drilling Company, Inc. 60 Drill Rig Drive, Buchanan, Virginia Telephone (540) Geothermal Heating & Cooling How it Works.
Welcome to Genuine Environmental solutions
WHAT ARE ITS CAUSES, EFFECTS AND SOLUTIONS
Bellringer What makes water hard?. Freshwater Pollution Notes.
Air & Water Solutions PROPRIETARY and CONFIDENTIAL Clean Water Plants for Massachusetts May 21, 2008 Sam Sofer, PhD, PE Debra Troy,
 Identifying the Relationship Between Agriculture and the Environment.
Water Treatment Processes. Why do we need to treat our drinking water?  Industrial runoff  Agricultural runoff  Road runoff  Residential runoff.
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ.
Going Green Interior Design. Today city-planners, engineers, builders, designers and consumers are looking for ways to reduce fuel and water consumption.
Water Pollution. Daily planet run EA2Ej7w8QF;_ylu=X3oDMTFkM25xMDloBHNlYwNzYwRzbGsDa HF2aWQEdnRpZAMEdmlkAzAwMDExNTIzOTM5BGdwb3MDNg.
Bio-Cascade, Inc Clean Air and Water Systems © Distributors of Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©) For Air and Water Solutions, Nutley,
Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)
Conserving Earth’s Resources P.Lobosco. Earth’s Resources  Today, Earth’s population continues to grow even as the resources shrink.
CHAPTER 17 Section 17-5; Indoor Air Pollution. OBJECTIVE:  Evaluate the types and effects of indoor air pollution.
POLLUTION Causes, effects and ways to prevent.  We can say that air is polluted when there are gases, liquids or solids which are not natural ingredients.
Microwave Destruction of Waste Rocket Fuels Waste Rocket Fuel Treatment Vapor Phase Destruction Easily Incorporated to Existing Water Scrubbing Systems.
Pollution.
THE GEOGRAPHY OF POLLUTION. GROUNDING INDUSTRY AND POLLUTION As a country develops, it industrializes, and industrial waste products are major polluters.
79 Readville St. Boston, MA www.Bio-Cascade.com.
Understanding Activities, Aspects, and Impacts in the EMS.
Water Treatment for the Recycling of Process Rinse Water
Green Engineering Careers Tom Rebold Chair, Engineering Department.
Water Pollution Thirsty?.
Objectives Name five primary air pollutants, and give sources for each. Name the two major sources of air pollution in urban areas. Describe the way in.
Welcome To Our Presentation 0f GENANO ® TECHNOLOGY For Senior Living Facilities.
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Chapter 2 Principles of Ecology.
Environmental Pollution -any addition of undesirable substances to the soil and air, and both surface and groundwater by human activities -can spread far.
Austin Pure Air Independent Agent - Products and Prices 2016 UNRIVALED PURIFICATION TO 1 NANO EVEN IN OUR SMALLEST UNIT Quiet Operation The GENANO 200.
Waste Water Treatment. Assignments Draw, label and explain each step in the wastewater treatment process.
INFILCO DEGREMONT, INC HIGH SOLID ANAEROBIC DIGESTION (HISAD)
Water management company AN ADVANCED SEWAGE WATER TREATMENT CONCEPT: e – IONIZATION TREATMENT.
SECTION 6 AIR CONDITIONING (HEATING AND HUMIDIFICATION) UNIT 34 INDOOR AIR QUALITY.
Air Pollution. Objectives Compare primary and secondary air pollutants Identify point-source and nonpoint-sources of air pollution in NC Identify sources.
Hazardous Waste Management.  Introduction  Classification of Hazardous Waste  Basic Approach in Hazardous Waste Management  Treatment of Hazardous.
Content 1.The main flowchart and technology 2.Advantage and disadvantages of each technology, way to improve. On-Nuch disposal site Group Member: Lu Li.
CE 360Dr SaMeH1 Environmental Eng. 1 (CE 360) Associate Professor of Environmental Eng. Civil Engineering Department Engineering College Majma’ah University.
Waste Water Treatment.
Indoor and outdoor air pollution, and Clean air act
Unit 5 Lesson 3 Human Impact on Water
Reducing Air Pollution
What Causes Air Pollution? Primary and Secondary Pollutants History of Air Pollution Motor Vehicle Emissions Industrial Air Pollution.
Company MIAB - Mölnbacka Industri AB of Deje, Sweden was established in MIAB provides equipment protecting the environment by removing solvent vapours.
DO NOW Pick up notes and Review #32. Turn in Review #31.
11.3 Notes Water Pollution.
Witt Environmental Science
Environmental Science Class Notes 03/02/17
Quality Standards Fresh water can contain a variety of harmful substances and organisms. Concentration refers to the amount of substance that is in another.
Understanding the Environmental Requirements for Fish
MOLCOM & EHS.
Presentation transcript:

Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)

Technology Background Dr. Sam Sofer PhD, PE; Principal engineer and inventor of the bio-hygienic products produced by the company. Air and Water Solutions Inc. based in NJ. Headquarters for manufacturing, research and development.

How CAP/CWP works Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids. Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process. Technology : Biological Oxidation

This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids. As contaminants come in contact with micro- organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless. Biological Oxidation (continued)

Bio-hygienics Contaminants and odors that are persistent travel on particulates. Most large particles will travel with air flow and can be vented. Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented. (bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications

These particulates are electrically charged. Their motion is controlled by electrical fields not by air flow. For these reasons, many odors linger even when an area is exhausted. CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.”CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.” Bio-hygienics

Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized. CWP© work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized. Bio-hygienics (continued)

Substantial cost savings Superior technology to –Carbon - substantially more economical –Thermal destruction –Removes and digests small particles and more that HEPA cannot handle. Single technology, single solution Very low maintenance Can be installed modularly to meet growing demands

Save on energy by reducing or eliminating costly venting and air exchange! CAP systems are fully sustainable “Green” Technology! Help environmental efforts!

Technology will eliminate nuisance odor and hazardous problems including : Anatomy labs Waste transfer and treatment plants Diesel and gasoline fumes Carbon Monoxide Mold and other spores Paint fumes. (Paint will even dry faster!) VOC’s Particulates Hair and nail salon fumes And much more…

CWP for real solutions to waste water discharge regulations. More economical than conventional treatments CAPs and CWPs are the only 100% bio-systems that address air and water contaminants.

CAP can even be customized to help reduce power plant emissions!

Real Data

Machine Operation The CAP™ Machine is can be modified to fit both stationary and portable applications. The size of the machine is based on both area covered and amount of pollution present Dual outlet power supply to run pump and fan.

Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines. Heaters can be added for exterior applications to prevent water freeze. CAP™ requirements for normal operation

BioOx © is the Bio-Enzyme microbial media used to consume pollution. Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation). BioOx added monthly or more frequently as needed. Bio-Ox® Natural Media

The more pollution,the more BioOx needed. Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems.

Trash Transfer Station Applications CAP 5000 with Rodent Intake Guards CAP ™ 5000

Can be made portable Will cover up to 3,000 sq.ft. 10 lbs. of pollution per day CAP ™ 90

CAP ™ 600 Covers areas over 5,000 sq.ft. Destroys up to 60 lbs. of pollution per day Interior and exterior applications

Compare Indoor Air Cleaners Type CleanerGasesVOC’SParticulatesBio-HygienicsSafety Ozone Ionizer UV HEPA (all air filters) Carbon Canister CAP Technology Evaluation Table for Indoor Air Cleaners

CAP™ Machine Specifications ModelEquiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application NEW CAP oz startup 2 oz/week for 2 mos. Thereafter 2 oz/month 12” sq x 15” 18 lbs 30 W Up to 800 ft 2 Room, office NEW CAP oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 12” sq x 20” 20 lbs 30 W Up to 1500 ft 2 Small house, office NEW CAP oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 12” sq x 24” 25 lbs 30 W Up to 2000 ft 2 Medium office, garage, shop, salon, schoolroom CAP-90 Industrial Model oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 15” sq x 32” 35 lbs 40 W Up to 3000 ft 2 Office, plant, garage, commercial & small industry

CAP™ Machine Specifications (continued) ModelEquiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model CleansTypical Application CAP gal. startup 16 oz/week for 2 mos. Thereafter 16 oz/month 30” dia x 48” 26” at base 200 lbs 175 W Units designed to handle commercial and industrial areas of 5000 ft 2 and larger, with heavy pollution load Small-medium industry, plant, warehouse, lab, loading dock, restaurant, bar, hotel, parking garage CAP gal. startup 48 oz/week for 2 mos. Thereafter 48 oz/month 36” dia x 50” ” fan housing 300 lbs 438 W Industry, plant, terminal, indoor/outdoor, heavy pollution CAP gal. startup ½ gal./week for 2 mos. Thereafter 64 oz/month 52” dia x 50” ” fan housing 500 lbs 500 W CAP-X Series (all models above) All environments. Specifically designed for extremely concentrated and toxic air contaminants Concentrated discharges from mixers, reactors and other similar equipment

CWP™ Machine Specifications ModelEquiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application CWP oz./mo. Startup: 16 oz. Then 4 oz/week for 2 mos. 12” sq x 20” 30 lbs Small, compact and portable For sinks, fish tanks, ponds. Small space applications CWP oz/mo. Startup: 32 oz. Then 8 oz/week for 2 mos. 12” sq x 20” 20 lbs 30 W Small-scale industry, industrial wastewater, waste tank contents, fuel- contaminated home sumps or direct treatment of ground water CWP-SVE oz/mo. Startup: 1 gal. Then 16 oz/week for 2 mos. 30” dia x 8” 100 lbs Saves on carbon costs For industrial applications, fish tanks, wells, ponds, small lakes.

CWP™ Machine Specifications (cont.) ModelEquiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application CWP oz./mo. Startup: 1 gal. Then 24 oz/week for 2 mos. 36” dia x 48” 250 lbs. Cleans large amounts of liquid. Designed for sudden increase in flow. Wastewater, chemical waste streams, waste tank contents. Large volume streams or surface water runoff. Direct treatment of groundwater. CWP oz./mo. Startup: 2 gal. Then 48 oz/week for 2 mos. 36” dia x 50” 250 lbs. CWP oz./mo. Startup: 3 gal. Then ½ gal./week for 2 mos. 52” dia x 50” 350 lbs. CWP gal./mo. Startup: 10gal. Then 1 gal./week for 2 mos. 72” dia x 84” 600 lbs.

For more information or to contact us: