Managing Patient Dose in Computed Tomography (CT)

Slides:



Advertisements
Similar presentations
Pregnancy and Medical Radiation
Advertisements

Image Reconstruction.
Estimation of Entrance Surface Doses (ESDs) for common medical X-ray diagnostic examinations in Radiological Departments in Mashhad-IRAN Presenter: Mr.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Pregnancy and Medical Radiation.
FPS HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENTFPS PUBLIC HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENT Medical Imaging Federal initiative Dr Aldo Perissino.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
RAD309 Patient Dose.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Interventional Procedures – Avoiding Radiation Injuries.
Business: Cell/Text: Presented by: Thomas J. LaRocca, M.S., D.A.B.R. Medical Physicist
Unit 1 Physics Detailed Study 3.6 Chapter 15: Medical Physics.
Special Radiographic examination
ICRP Publication 117 Authors on behalf of ICRP M.M. Rehani, O. Ciraj-Bjelac, E. Vano, D.L. Miller, S. Walsh, B.D. Giordano, J. Persliden.
Saira Ahmad UOG. CAT Scans CAT Scans ( Computerized axial tomography) Topic:
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Management in radiology seminar February Tehran-Iran
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Radiologic Procedures
October 27, 2009MDCH/RSS CON Seminar 1 Computed Tomography (CT) Proposed Rules for Radiation Safety John Ferris, Health Physicist Radiation Safety Section.
International Atomic Energy Agency L 4 PROTECTION ISSUES IN CLINICAL METHODOLOGY.
Radiation Dosimetry of the Patient
Optimizing Patient Radiation Dose
What is CT?  CT scans use x-rays generated from the source that is rotated around the body to create 3 dimensional pictures of the body. What is an x-ray?
Radiation Protection of Patients Unit
Radiation Safety in Children
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
The ICRP System of Protection Applied to Medical Exposures
Knowledge of radiation exposure in common radiological examinations amongst radiology department staff AL Chang, LH Cope, DH Keane, S Wood Presented by.
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
BEIR VII Implications of the Report for the Future of Medical Imaging G. Donald Frey, Ph.D. Department of Radiology Medical University of South Carolina.
Reduction of effective and organ dose to the eye lens in cerebral MDCT scans using iterative image reconstruction Zizka J, Jandura J, Kvasnicka T, Klzo.
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Amanda Bath Advance Practitioner RPS
Part 2.
Radiology started with simple traditional x-ray technology.
RADIOGRAPHY & IT’S MODALITIES SPRING INFORMATION WORKSHOP 2011.
1 Radiation Dosimetry in X-Ray Computed Tomography (CT): Standardization and Regulation Stanley H. Stern, Ph.D. Center for Devices and Radiological Health.
Radiation Sources in medicine diagnostic Radiology
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
PACS in Radiology By Alanoud Al Saleh.
Some reasons for unnecessary procedures
Diagnostic reference levels in Medical Imaging. Concept and practice
Radiation Sources in medicine diagnostic Radiology
Week 2 :Radiation Protection
Introducing cross- sectional imaging Dr.Ahmed S. Tawfeek FIBMS(Rad.)
Trends in Patients’ Exposure Doses during Radiographic Examination in Japan Shoichi Suzuki 1, Yasuki Asada 1, Masanao Kobayashi 2, Kenichi Kobayashi 2,
MEDICAL USES FOR RADIATION Andres Perez P.1 Level 4 MT10.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
IS THERE A RATIONAL APPROACH TO RADIATION RISK? Philip F. Judy Ph.D. Department of Radiology Brigham and Women's Hospital New England AAPM Chapter Meeting.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Wednesday Case of the Day History: CT pulmonary angiography (image shown) was performed on a 24-year-old female patient with pleuritic chest pain and increased.
Medical Imaging Lecture 1. What is Medical Imaging?? Medical imaging refers to a number of techniques that can be used as non-invasive methods of looking.
BY: Avantika tiwari B-tech (ece) B-1 Batch. X-ray computed tomography, also computed tomography (CT scan) or computed axial tomography (CAT scan), is.
Computed Tomography Aleena Persaud, Jodie Law, Ratheka Sivasubramaniam.
BY GAMINI SENANAYAKE.  Legislation applicable to staff and public Ionising radiation regulations 1999  Legislation applicable to patients – Ionising.
Computers in Health Care
RADIATION PROTECTION 04/12/2016.
CT Multi-Slice CT.
Medical Uses of Radioactivity
Patient exposure trends and problems in implementing ALARA
Optimisation of Patient Protection for Radiography
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
CT dose optimization software synergy – A clinical perspective
Introduction to Radiology
Strategies for Reducing Radiation Exposure From Multidetector Computed Tomography in the Acute Care Setting  Aaron Sodickson, MD, PhD  Canadian Association.
Radiation Protection in Dental Radiology
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Managing Patient Dose in Computed Tomography (CT)
Presentation transcript:

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani, G. Bongartz, S.J. Golding, L.Gordon, W. Kalender, T. Murakami, P. Shrimpton, R. Albrecht, K. Wei INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Use and disclaimer This is a PowerPoint file It may be downloaded free of charge It is intended for teaching and not for commercial purposes This slide set is intended to be used with the complete text provided in ICRP Publication 87 INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Contents Situation analysis Why increased frequency? Why increased dose? Is the dose really high? How high? What can be done to manage patient dose? What can operator do? Action for manufacturer Action for physician & radiologist INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Situation analysis CT continues to evolve rapidly despite many advances in other imaging modalities It is one of the most important radiological examinations worldwide The frequency of CT examinations is increasing rapidly from 2% of all radiological examinations in some countries a decade ago to 10-15 % now Patient doses in CT have not decreased in contrast to radiography where nearly 30% reduction has been documented in last decade INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

UNSCEAR 2000 INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Why increased frequency? 20 years ago, a standard CT of the thorax took several minutes while today similar information can be accumulated in a single breath hold making it attractive, patient & user friendly Advances in CT technology have made possible CT fluoroscopy and interventional procedures, in some cases replacing ultrasound guided interventions Recently CT screening is picking up INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Why increased dose… Unlike radiography where over-exposure results in blackening of film, better image quality is obtained with higher exposures in CT There is a tendency to increase the volume covered in a particular examination Modern helical CT involves volume scanning with no inter-slice gap and with possibility of overlapping scans Repeat CT examinations INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Why increased dose (cont’d) Same exposure factors used for children as for adult Same exposure factors for pelvic (high contrast region) as for abdomen (low contrast region) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

What is the dose from CT? How high? The effective dose in chest CT is in the order of 8 mSv (around 400 times more than chest radiograph dose) and in some CT examinations like that of pelvic region, it may be around 20 mSv The absorbed dose to tissues from CT can often approach or exceed the levels known to increase the probability of cancer as shown in epidemiological studies INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Effective doses in CT and radiographic examinations CT examination Effective dose (mSv) Radiographic examination Head 2 Skull 0.07 Chest 8 Chest PA 0.02 Abdomen 10-20 1.0 Pelvis 0.7 Ba swallow 1.5 Ba enema 7

Organ doses in CT Breast dose in thorax CT may be as much as 30-50 mGy, even though breasts are not the target of imaging procedure Eye lens dose in brain CT, thyroid in brain or in thorax CT and gonads in pelvic CT receive high doses INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Tissues in the field although they are not the area of interest for the procedure Lens of the eye Breast tissue INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Typical doses in mGy during CT in adults (Shrimpton et al. 1991) Examination Eyes Thyroid Breast Uterus Ovaries Testes Head 50 1.9 0.03 * Cervical spine 0.62 44 0.09 Thoracic spine 0.04 0.46 28 0.02 Chest 0.14 2.3 21 0.06 0.08 Abdomen 0.05 0.72 8.0 0.7 L. spine 0.01 0.13 2.4 2.7 Pelvis 26 23 1.7 The symbol * indicates that dose is < 0.005 mGy

Does spiral CT give more or less radiation dose? It depends upon the choice of factors Even though it is possible to perform a spiral CT with lower radiation dose than slice-by-slice CT, in practice the patient gets higher dose due to the factors chosen (scan volume, mAs, pitch, slice width INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Does multi-slice CT impart more or less radiation dose? An increase by 10-30% may occur with multi-slice detector array INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Some observations Most doctors including many radiologists have a feeling that modern CT scanners which are very fast give lesser radiation dose Unfortunately ‘time’ and ‘radiation dose’ are not proportional in such a situation Over the years the x-ray tubes are becoming more and more powerful such that they can give high bursts of x-rays which can give satisfactory image in shorter exposure time INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

What can be done to manage patient dose in CT? INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

What can operators do…? Limit the scanned volume Reduce mAs values Use automatic exposure control by adapting the scanning parameters to the patient cross section. 10-50% reduction in dose documented, without any loss of image quality INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

What can operators do (cont’d) Use of spiral CT with pitch factor>1 and calculation of overlapping images instead of acquiring overlapping single scans Shielding of superficial organs such as thyroid, breast, eye lens and gonads particularly in children and young adults. This results in 30-60% dose reduction to the organ INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

What can operators do (cont’d) Separate factors for children. Can reduce dose by a factor of 5 or more Use of partial rotation e.g. 270 degree in Head CT (refer figure on next slide) Adequate selection of image reconstruction parameters Use of z-filtering with multi-slice CT systems Record of dose, exposure factors INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Dose distribution (in relative units) through the section of the skull (face-up) for 270o scan omitting the frontal 90o. Minimum dose occurs in the region of the eyes. The doses are slightly higher on left side since in this unit x ray tube rotates by an additional 20oc (clockwise) for patient movement (adapted from Robinson 1996).

Actions for manufacturers Introduce automatic exposure control Be conscious of high doses in CT Include safety features to avoid unnecessary dose Display of dose Convenience in using low dose protocols Draw attention of users to selecting separate protocols for paediatric patients INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Actions for physician & radiologist… Justification: Ensure that patients are not irradiated unjustifiably Request for CT examination should be generated only by properly qualified medical or dental practitioners depending upon national educational and qualification system. The physician is responsible for weighing the benefits against risks Clinical guidelines advising which examinations are appropriate and acceptable should be available to clinicians and radiologists INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Actions for physician & radiologist (cont’d) Consider whether the required information be obtained by MRI, ultrasonography Consider value of contrast medium enhancement prior to commencing examination CT scanning in pregnancy may not be contraindicated, particularly in emergency situations, although examinations of the abdomen or pelvis should be carefully justified INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Actions for physician & radiologist (cont’d) CT examination should not be repeated without clinical justification and should be limited to the area of interest Clinician has the responsibility to communicate to the radiologist about previous CT examination of the patient CT examination for research purpose that do not have clinical justification (immediate benefit to the person undergoing the examination) should be subject to critical evaluation by an ethics committee INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Actions for physician & radiologist (cont’d) CT examination of chest in young girls and young females needs to be justified in view of high breast dose Once the examination has been justified, radiologist has the primary responsibility for ensuring that the examination is carried out with good technique INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Web sites for additional information on radiation sources and effects European Commission (radiological protection pages): europa.eu.int/comm/environment/radprot International Atomic Energy Agency: www.iaea.org International Commission on Radiological Protection: www.icrp.org United Nations Scientific Committee on the Effects of Atomic Radiation: www.unscear.org World Health Organization: www.who.int INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————