Types Selection Complications

Slides:



Advertisements
Similar presentations
Edward Evans MD FACC Desoto Heart Clinic Disclosures Medtronic:speaker St. Jude Medical:speaker.
Advertisements

Mechanical heart valves and Anticoagulation
Treatment of Mitral Stenosis.  Medical  Valvotomy  Interventional  Surgical Treatment of Mitral Stenosis.
Non-Invasive Assessment of Prosthetic Valves
Echocardiographic Evaluation of Prosthetic Heart Valves
AORTIC VALVE PROSTHESIS. Basic Types of Artificial Heart Valves Mechanical – made of synthetic material Tissue valve – made from animal tissues called.
Mitral Valve Prosthesis. Types of mechanical valves:  Ball-cage valve (Starr-Edwards is the most common). - a spherical occluder is contained by metal.
METAΛΛΙΚΗ ΠΡΟΣΘΕΤΙΚΗ ΒΑΛΒΙΔΑ-ΑΥΤΟΝΟΜΗ ΝΟΣΟΣ? Γ.ΔΡΟΣΟΣ Καρδιοχειρουργική Κλινική ΓΝΘ Γ. Παπανικολάου, Θεσσαλονίκη.
Prosthetic Heart Valves Presentation by Brian Meyer.
Echocardiography of Prosthetic Valves
Artificial Heart Valves By: Brian Volpe. What is it? An artificial heart valve is a mechanism that mimics the function of a human heart valve It’s used.
Artificial Heart Valves. Heart/Heart Valves Heart consists of: Right Atrium and Ventricle Atrium Left Atrium and Ventricle Two Types of Valves: Atrioventricular.
AVR: Choice of Prosthesis Tirone E. David University of Toronto.
Mechanical or Bioprosthetic valve for middle-aged patient Dr.Vijay Dikshit Apollo Hospitals, Hyderabad.
Complications in Valvular Heart Surgery
Trileaflet Aortic Valve. Management strategy for patients with chronic severe aortic regurgitation. Preoperative coronary angiography should be performed.
© Continuing Medical Implementation …...bridging the care gap Valvular Heart Disease Aortic Stenosis.
PROSTHETIC VALVE BOARD REVIEW
Echocardiographic Evaluation of Prosthetic Valves, Part I
Alsharqia.riyadh Echo meeting Dammam KSA SAYED ABOU EL SOUD MD SBCC.
Aetiology * MVP { Myxomatous mv },commonest in developed world *Damage to the cusps : _RVD _ IE _ Congenital Cleft MV *Damage to chordae : _RVD.
Common Clinical Scenarios *Younger people *Younger people _Functional murmur vs _Functional murmur vs _ MVP vs _ MVP vs _ AS _ AS *Older people _Aortic.
Valvular Heart Disease
Valvular Heart DISEASE
ALLOGRAFT VALVE SURGERY P.Skillington CANBERRA April 2003.
Valvular Heart Disease Jagdish Butany MBBS,MS,FRCPC. Prof.,Dept Lab Med & Pathobiol. Pathologist,UHN/TGH. Physical Therapy 5 Nov 2007.
Indication and contra-indications for cardiac catheterization
Mitral Valve Disease Prof JD Marx UFS January 2006.
Valvular Heart Disease Ronald D’Agostino, D.O., F.A.C.C., F.A.C.P. Director of Non-Invasive Cardiology Long Island Cardiovascular and Internal Medicine.
Causes of valve disease Valve regurgitation * Congenital *Acute rheumatic carditis *Chronic rhe. Carditis * I E *Syphlitic aortitis *Dilated Valve.
PROSTHETIC HEART VALVE : Types, Selection, and Functional assessment Dr SHAJUDEEN 2 nd Year DM Resident.
ISKANDER AL-GITHMI, MD, FRCSC Consultant Cardiothoracic Surgeon Assistant Professor of Surgery King Abdulaziz University ISKANDER AL-GITHMI, MD, FRCSC.
Surgical outcome of native valve infective endocarditis in srinagarind hospital
Valve Surgery V.Rohn. Valve Surgery History before the era of ECC 1925 – Suttar – first successful digital commisurolysis of mitral valve 1952 – Hufnagel.
Mitral Regurgitation. Abnormalities of the Mitral Valve Valve Leaflets Chordae Tendineae Papillary Muscles Mitral Annulus.
Mechanical PVR Pearls & Pitfalls Joseph A. Dearani, MD Division of Cardiovascular Surgery AATS Seattle April 2015.
Prosthetic Valve Dysfunction
Adult Cardiac Valve Disease Marvin D. Peyton, M.D. Thoracic and Cardiovascular Surgery University of Oklahoma Health Sciences Center.
Aortic Root Dilatation S/P Ross Procedure
Long-term Survival, Valve Durability, and Reoperation for Four Aortic Root + Ascending Procedures Lars G. Svensson, Saila T. Pillai, Jeevanantham Rajeswaran,
1 Heart Valve Disease Valvular heart disease Valves make sure blood flows in a forward direction –no backward leakage Tricuspid and mitral.
3/98medslides.com1 Aortic Valve Homografts A Cinical Perspective Michael E. Staab, MD Rick A. Nishimura, MD Joseph A. Dearani, MD Thomas A. Orszulak, MD.
Prosthetic heart valves: management of usual and unusual complications January 14 th, h-15h30.
Transcatheter Cardiovascular Therapeutics 2008 (October 12-17, 2008 · Washington, DC) First-in-Human Report: Initial Experience with a Stentless and Retrievable.
Antithrombotic and Thrombolytic Therapy for Valvular Disease Copyright: American College of Chest Physicians 2012 © Antithrombotic Therapy and Prevention.
Date of download: 5/29/2016 Copyright © The American College of Cardiology. All rights reserved. From: 2014 AHA/ACC Guideline for the Management of Patients.
Cardioembolic Stroke: Diagnosis and Management
Causes of Heart Valve Dysfunction Congenital defects (bicuspid aortic valve) Infections (rheumatic fever and bacterial endocarditis Coronary artery disease.
Antithrombotic and Thrombolytic Therapy for Valvular Disease Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest.
Date of download: 6/23/2016 Copyright © The American College of Cardiology. All rights reserved. From: Choice of Prosthetic Heart Valve in Adults: An Update.
Division of Cardiology Department of Internal Medicine Tae Kyung Yu
EXPANDING INDICATIONS OF TRANSCATHETER HEART VALVE INTERVENTIONS. JACC CARDIOVASCULAR INTERVENTION. DR.RAJAT GANDHI.
Thanks ………… Echocardiographic Evaluation Of Prosthetic Cardiac Valves Dr Gaurav Kumar Chaudhary MD,DM( Cardiology) Assistant Professor Department of Cardiology.
Date of download: 7/8/2016 Copyright © The American College of Cardiology. All rights reserved. From: Choice of prosthetic heart valve for adult patients.
© free-ppt-templates.com 2017 AHA/ACC Focused Update of Valvular Heart Disease Guideline of 2014 DR. OMAR SHAHID TR CARDIOLOGY SZH.
Original slides courtesy of Dr. Alex Morss
Cardiac Valves Jeffrey R. Scott, Ph.D..
PROTESI VALVOLARI CARDIACHE:
Cardiothoracic Surgery
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
AORTIC STENOSIS.
Aortic Valve Homografts A Cinical Perspective
Challenges in the Surgical Management of Aortic and Mitral Valve Endocarditis (IE) Oct 2016 Epworth P Skillington,
Adult Echocardiography Lecture 11 Prosthetic Valves
Infective Endocarditis
Kyle D Buchanan, MD MedStar Washington Hospital Center
Late Follow-Up from the PARTNER Aortic Valve-in-Valve Registry
Evolution of mechanical heart valves
Slides courtesy of Dr. Randall Harada
Endocarditis is an inflammation of the endocardium, the membrane lining the chambers of the heart and covering the cusps of the heart valves. Infective.
Presentation transcript:

Types Selection Complications Prosthetic valves Types Selection Complications

Types Bioprosthetic valves Mechanical Heterograft (xenograft) Bovine porcine Homograft (allograft) Autograft Pericardial Pulmonary (Ross) Mechanical Caged ball valve Tilting disc valve Bileaflet valve

Heterografts(xenografts) The Hancock M.O. II aortic bioprosthesis (porcine) Stentless Porcine Toronto SPV valve, medtronic freestyle valve Stented - facilitate implant, maintain 3D relationship,more physiological flow Hancock , carpenteir edward s, medtronic Bovine Stented bovine p prosthesis Carpentier-Edwards Duralex mitral bioprosthesis

Tissue heterograft Advantages Disadvantages - No need of anticoagulation after 1st 3 m Little hemolysis Disadvantages Limited ,uncertain durability Cuspal tear Perforation degeneration Rapid deterioration esp children Fibrin depostn Ca++ 10-30% need re op in 10 yr 30-60% need re op in 15 yr Small size have poor hemodynamics

Bioprosthetic valve Preferred in Pregnancy Bleeding Diathesis Age> 70 years Poor compliance

Mechanical valves Caged ball valve Advantages Disadvantages Oldest durabilty upto 40 yr Disadvantages high profile hemolysis high thrombogenecity Poor hemodynamics in small sizes Unique features Occluder travels completely out of the orifice, reduces thrombus & pannus growing from the sewing ring Continuously changing points of contact of the ball reduces the wear & tear in any one area Thrombogenic risk 4-6% / year

Starr Edwards Valve not suitable - for the mitral position in patients with a small left ventricular cavity - for the aortic position in those with a small aortic annulus - those requiring a valve-aortic arch composite graft

Tilting disc valve- monoleaflet - Medtronic Hall valve - Omnicarbon (Medical CV) - Monostrut (Alliance Medical Technologies) - Bjork-Shiley valves Adv low profile Good hemodynamics even in small sizes Excellent durability Permit central laminar flow Medtronic hall valve Titanium housing teflon sewing ring carbon coated disc disadv – Anticoagulation mandatory higher risk of thrombosis than cage ball v sudden catastrophic valve thrombosis

Bileaflet valve Adv – Anticoagulation mandatory risk of thrombosis St. Jude Medical mechanical heart valve Bileaflet valve Adv – Low bulk - flat profile Less thrombogenicy Central laminar flow two semicircular discs that pivot between open and closed positions No need for supporting struts Good hemodynamics even in small sizes 2 lat ,1 central minor orifice , no chance of sudden catastro thrombosis Disadv- Anticoagulation mandatory risk of thrombosis Carbomedics Titanium housing Pyrolytic carbon

Model Thrombogenicity Types of prosthetic valves and thrombogenicity Type of valve Model Thrombogenicity Mechanical Caged ball Starr-Edwards ++++ Single tilting disc Bjork-Shiley,Medtronic Hall +++ Bileaflet St Jude Medical,Sorin Bicarbon,Carbomedics ++ Bioprosthetic Heterografts Carpentier-Edwards,Tissue Med (Aspire), Hancock II + to ++ Homografts +

TTK chitra tilting disc valve - metallic housing (cobalt based wrought alloy) - circular disc high molecular weight polyethylene - A polyester suture ring Hemodynamically comparable to other mechanical valves valve related complications are similar

Characteristics of Various prosthetic valves

Flow Dynamics

Desired valves Mechanical valves - preferred in young patients who have a life expectancy of more than 10 to 15 years who require long-term anticoagulant therapy for other reasons (e.g., atrial fibrillation) Bioprosthetic valves preferred in patients who are elderly have a life expectancy of less than 10 to 15 years who cannot take long-term anticoagulant therapy A bileaflet-tilting-disk or homograft prosthesis is most suitable for a patient with a small valvular annulus in whom a prosthesis with the largest possible effective orifice area is desired.

algorithm for choice of prosthetic heart valve

Radiologic Identification Starr-Edwards caged ball valve Radiopaque base ring Radiopaque cage Three struts for the aortic valve; 4 struts for the mitral or tricuspid valve Silastic ball impregnated with barium that is mildly radiopaque (but not in all models)

TTE – stenosis Valve area calculations Continuity equation Area Ao prosthesis = (diameter sewing ring)² x 0.785xLVOT VTI/ Ao prosthesis VTI Area mitral prosthesis= (diameter LVOT)²x 0.785xLVOT VTI/ VTI mitral prosthesis Pressure Half time ( mitral valve prosthesis) Dimensionless index- LVOT velocity/ aortic prosthesis velocity < 0.23 indicates prosthetic valve stenosis

Prosthetic Valve regugitation Mitral – velocity2.5m/sec - jet area 2cm² Aortic -- aortic PHT≤ 250m/sec -- flow reversal in aorta

Normal Doppler Values of Prosthetic Valves Aortic Position Mitral Position Velocity Mean Gr Starr Edward 3.1±0.5 24±4 St Jude 3.0±0.8 11±6 Medtronic Hall 2.6±0.3 12±3 Aortic Homograft 0.8±0.4 7±3 Hancock 2.4±0.4 11±2 Carpentier’s 2.4±0.5 14±6 Velocity MeanGr Starr Edward 1.8±0.5 7±2 St Jude 1.5±0.3 5±2 Medtronic Hall 1.6±0.3 5±2 Aortic Homograft 1.5±0.4 4±2 Hancock 1.5±0.3 5±2 Carpentier’s 1.5±0.3 5±2

Importance of TEE higher-resolution image than TTE size of vegetation defined more precisely peri annular complications indicating a locally uncontrolled infection (abscesses, dehiscence, fistulas) detected earlier limitation -inability to detect aortic prosthetic-valve obstruction or regurgitation, especially when a mitral prosthesis is present

Mitral Bileaflet

Cinefluoroscopy Structural integrity Motion of the disc or poppet excessive tilt ("rocking") of the base ring - partial dehiscence of the valve Aortic valve prosthesis - RAO caudal - LAO cranial Mitral -- RAO cranial

Fluoroscopy of a normally functioning CarboMedics bileaflet prosthesis in mitral position A=opening angle B=closing angle

St. Jude medical bileaflet valve Mildly radiopaque leaflets are best seen when viewed on end Seen as radiopaque lines when the leaflets are fully open Base ring is not visualized on most models

MRI Not useful in assessing prosthetic-valve structure used only when prosthetic-valve regurgitation or para valvular leakage is suspected but not adequately visualized by echocardiography

Cardiac Catheterization measure the transvalvular pressure gradient, from which the EOA can be calculated can visualize and quantify valvular or paravalvular regurgitation

Valve dysfunction complication example Role of echo Primary mechanical failure Ball variance Strut fracture Visualize structure, assess gradient & regurgitation Nonstructural dysfunction Pt- prosthesis mismatch pannus Gradient, visualize tissue in & around the sewing ring Bleeding event Intracranial hge Source of embolus, presence & mobility of masses Endocarditis Vegetation, abcess, dehiscence Visualize area around the sewing ring, echo dense / lucent area, perivalvular regurgitation Thrombosis Thrombus impedes opening &closing of occluder mechanism Localize mass, assess gradient, detect regurgitation Embolism stroke Identify & characterize the source of emboli

patient-prosthesis mismatch When the effective prosthetic valve area, after insertion into the patient less than that of a normal valve (Rahimtoola in 1978) EOA indexed to BSA is less than 0.85 cm2/m2 EOA (echo) differs from geometric orifice area (measured directly) EOA for each prostheses type & size obtained in literature from pts normally functioning prostheses Average if > 1 value -- mild (0.9 - 1 cm² /m² -- moderate (0.6 - 0.9 cm2/m² -- severe (iEOA < 0.6cm²/m² (Rahimtoola)

in-vitro area of the majority of valve prostheses ( int diameter <23 mm) < that of the normal human valve area the in-vivo prosthetic area further reduced by IVS hypertrophy, progressive endothelialization and tissue ingrowth (Aortic prosthetic devices may be functionally stenotic)

three-step algorithm Step 1: Calculation of the patient BSA. Step 2: Reference to the specific table for identification of the adequate valvular EOA according to the patient BSA. Step 3: Selection of the most appropriate type and size of valve prosthesis according to the target iEOA

Valve Thrombosis <0.2% per year for mech valves Incidence of 0.1 to 5.7 % per patient-year <0.2% per year for mech valves <0.1% bioprosthetic valves small thrombus, at the hinge portion of a bileaflet valve obstruct the mechanism tilting disk -- a much larger thrombus to prevent function Ball and cage valves – less susceptible  occluder has no contact at all with the valve housing for a portion of every cycle Clinical Non obstructive- incidental/embolic phenomenon Partial obstruction- dyspnea,systemic embolism , fever Severe obstruction- overt heart failure

Fibrinolytic therapy - Rt sided thrombosis 80-100% success rate Surgery for fibrinolysis failure/symptoms > 3 wk Surgery – Lt sided thrombosis, large clot burden

FIBRINOLYTIC PROTOCOL heart 2007;93:137-142 2 types of protocol -rescue fibrinolysis (short protocol for unstable pt) - long protocol for stable pt Short protocol - r tPA 10 mg bolus + 90 mg in 90 min or - SK 15lac in 60 min Long protocol -- SK- 5lac u in 20 min f/b 15lac u for 10 hr -- rtPA -- 10 mgbolus f/b 90mg/hr for 9 hrs Urokinase High dose: 4,500 IU/kg/h for 12 h without heparin Low dose: 2,000 IU/kg/h with heparin for 24 h

Embolisation cerebral embolization  CT normal/infarctwarf & heparin – 72 hrs APTT lower therapeutic level till the desired INR anticoagulantion delayed for at least 7 to 14 days - ICH, extensive cerebral infarction  OAC

If embolic event occurs while the patient is on adequate antithrombotic therapy If on warfarin with INR of 2.0 to 3.0: increase dose to achieve INR of 2.5 to 3.5 If on warfarin with INR of 2.5 to 3.5: add aspirin 50 to 100 mg/d If on warfarin with INR of 2.5 to 3.5, plus aspirin 80 to 100 mg/d: aspirin dose may also need to be increased to 325 mg/d If on aspirin 325 mg/d: switch to warfarin with goal INR of 2.0 to 3.0

Excessive Anticoagulation vit K 2.5 mg daily until the INR is acceptable fresh frozen plasma Human recombinant factor VIIa, 15 to 19 g/kg (INR >10.0 with bleeding)

Structural Failure of Bioprosthetic Valves About 30 % of heterograft bioprosthetic valves and 10 to 20 % of homograft valves require replacement within 10 to 15 years because of structural failure severe regurgitation due to a tear or rupture of one or more of the valve cusps calcified and rigid valves Rarely severe valvular stenosis

Structural deterioration Higher incidence patients <40 years & with mitral prostheses gradual onset of dyspnea and other symptoms of heart failure Bioprosthetic-valve regurgitation or stenosis can be detected by auscultation valve dysfunction assessed by echocardiography or catheterization

Failure of Bio prosthetic Valves

Hemolysis Incidence - 6% Subclinical intravascular hemolysis severe hemolytic anemia uncommon & suggests paravalvular leakage due to partial dehiscence of the valve or infection Patients with a caged-ball valve / multiple prosthetic valves have an increased incidence & severity of hemolysis.

Hemolysis Pts with hemolytic anemia treated with iron & folate supplements or blood transfusion - decreased blood viscosity & increased COP a/w anemia increase the hemolysis Paravalvular leakage & severe hemolysis – valve replacement or repair

Para valvular leak improper implantation of a valve A heavily calcified annulus is a risk factor for paravalvular leaks -- incomplete debridement of calcium compromises both suture placement and valve seating Active endocarditis is also a risk factor Late paravalvular leaks are suggestive of prosthetic valve endocarditis generally result in hemolysis In the absence of a paravalvular leak, a normally functioning modern valve should not result in hemolysis

Paravalvular Regurgitation mild or moderate paravalvular leakage - asymptomatic , may have only a mild hemolytic anemia - can be observed carefully with serial echo severe paravalvular leakage - usually have symptoms of heart failure or severe anemia - should be treated with surgical repair or replacement of the valve

PVE (2-6%) salient features Endovascular, microbial infection occurring on parts of a valve prosthesis or on reconstructed native heart valves , with or without implantation of an annular ring early PVE is 5% higher in surgery during active IE Diagnostic approach, surgical indications same

PVE how diff from native? PVE NVE Early- nosocomial Late- comm acquired Mech prosthesis -originate from the sewing cuff /from nearby located thrombi → periprosthetic leaks, ring abscesses, invasion of adjacent tissue Bioprosthesis infections mostly restricted to the cusps → secondary bioprosthetic failure Staphylococci, HACEK group, fungi occur more frequently in PVE Strepto & enterococci found more frequently in native valve endocarditis

vegetations larger irreversible adhesion production of a biofilm,  inhibit the host defence mechprotects against antimicrobial Tt Duration of Tt longer Smaller No such biofilm

Pannus Valve obstruction occurs 5-10% of mechanical valves per year Thrombus Pannus mobile, somewhat less echo-dense, associated with spontaneous contrast Pannus formation -more common in aortic position fibrous tissue ingrowth highly echogenic usually firmly fixed to the valve apparatus Pre valve jet suggests pannus

MCQ

1. Factors favouring bioprostheses include all except a 1.Factors favouring bioprostheses include all except a. Age > 70 yrs b. Bleeding diathesis c. Combined multivalvular placement d. Poor compliance

2. Which of the following favours valve repair. a. RHD b 2. Which of the following favours valve repair? a. RHD b. Endocarditis c. Extensive leaflet destruction d. MVP

3. Which is the most durable mechanical prosthesis. a 3. Which is the most durable mechanical prosthesis? a. St Jude medical b. Medtronic Hall c. Starr- Edwards d. Bjork Shiley

4. Indication for long term anticoagulation in aortic bioprosthesis include all except a. Prior embolic events b. Atrial fibrillation c. Ventricular tachycardia d. LV dysfunction

5. 55yr male, s/p AVR for BAV , SR, good LV function, Dental prophylaxis needed, anti thrombotic therapy would be the following Stop warf 72 hrs before procedure, restart after control of bleeding Stop warf 72 hrs before procedure, start heparin 48hrs before procedure Stop warf 1wk before procedure d. Continue warf

6 . Heparin alone regimen in a pregnant lady on OAC, s/p MVR , thrombo embolic complications would be 25% 33% 43% 45%

7. Ideal anti thrombotic therapy in a 45 yr female, s/p MVR for RHD, with h/o embolic stroke would be the following Warfarin INR 2.5- 3.5, aspirin 50- 100mg Warfarin INR 2.0 - 3.0, aspirin 50- 100mg Warfarin INR 2.5- 3.5, aspirin 75- 150mg Warfarin INR 2.0 - 3.0, aspirin 75- 150mg

8. Prosthetic valve thrombosis would be catastrophic in the following Bioprosthesis Tilting disc valve Bileaflet valve Starr- Edwards valve

9. Mitral prostheses best assessed by RAO cranial RAO caudal LAO cranial LAO caudal

10. Clinical hemolysis is maximum with Caged ball Bioprosthesis Tilting disc Bileaflet