EPA Pesticide Container and Repackaging Regulations, Flow Chart 3: Can I fill this small portable refillable container (capacity of 119 gallons or less)?

Slides:



Advertisements
Similar presentations
EPAs Refillable Container Requirements Ag-IBC Summit 2010 September 8, 2010.
Advertisements

AIRWORTHINESS ASPECTS OF AIRCRAFT LEASING
Radiopharmaceutical Production
Transition from Q1- 8th to Q1- 9th edition
Please read this before using presentation
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration WELCOME DOT DESIGNATED APPROVAL AGENCIES March 17, 2014 Thomas.
Reusable Industrial Packaging Association RIPA IBC Compliance Workshop Grand Hyatt Tampa Bay Tampa, Florida March 6, 2013.
ASME PLATE REGULATIONS Presented by Sgt. Brad Wagner, Nebraska State Patrol Carrier Enforcement November 8, 2006.
EPA Pesticide Container and Repackaging Regulations, Flow Chart 2: Can I fill this large portable refillable container (greater than 119 gallons)? (end.
1 Pesticide Container-Containment Regulation Update U.S. EPA Office of Enforcement and Compliance Assurance Western Regions/States/Tribes Pesticide Meeting.
Mobile, Alabama February 5-7, 2013 Pesticide Stewardship Conference.
EPA’s Pesticide Container-Containment Regulations Agricultural Retailers Association June 11, 2009.
EPA’s Refillable Container Requirements Are You Ready? IFCA Workshop January 20, 2011.
Caged Tanks for Pesticides: Terminology, EPA Regulations and Pesticide Labels Rinsing and Recycling Caged Tanks Nancy Fitz Chemical Engineer U.S. EPA Office.
Temporary storage Sven Hagemann GRS. Types of temporary storage 1.Storage of commodity mercury  Dealer, wholesaler, governmental stocks 2.Storage of.
GMP Document and Record Retention
3.2.5 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Requalifying DOT Cylinders by CGA External Visual.
Pesticide Container-Containment Regulations: FIFRA 19(f)(2) Determinations of Adequacy.
UN Performance Packaging Standards Chris Lind Director Technology & Regulatory Affairs Mauser USA LLC.
Girard Equipment, Inc. DOT REGISTERED TANK COMPONENT MANUFACTURER 4360 Old Dixie Hwy, Vero Beach, FL MC307 to DOT407 Conversion.
QLF Contract Quality Clauses Working Group QUALITY LEADERSHIP FORUM CONTRACT QUALITY CLAUSES WORKING GROUP Ken Crane MSFC September 24, 2002.
Laboratory Accumulation of Hazardous Waste Presented By: Richard Smith Environmental Health & Safety Administrative Office Research and Extension Centers.
1 EPA’s Pesticide Container and Containment Rule: Implementation Western States Meeting May 16, 2007 U.S. EPA Office of Pesticide Programs.
Mjt 8/24/2004 UNRESTRICTED - May be shared American Agronomic Stewardship Alliance(AASA) PROGRAM OVERVIEW.
The Sentinel Event During a routine annual hazardous waste management inspection by the Hazardous Waste Section of NC DENR, violations in laboratory practices.
Hazardous Materials Transportation
Student Book © 2004 Propane Education & Research CouncilPage 1 To provide safe and efficient transporting of bulk containers, such as ASME tanks.
1 Reusable Industrial Packaging Association Hazardous Materials Employee Training 2015 Edition Title 49 Code of Federal Regulations § ‑
Health Insurance Portability and Accountability Act (HIPAA)
Please use the following two slides as a template for your presentation at NES. Completing the DD Form 1149: — A Basic Perspective Walt Clark, CPPM Property.
BRC Food Safety Quality Management System Training Guide
World Health Organization
U D T Workshop on the Pressure Equipment Directive, Warsaw June 2004 INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC SYSTEM OF ENSURING.
2.5.3 Student Book © 2004 Propane Education & Research CouncilPage Verifying Proper ASME Tank Condition Prior to Loading For the safe and efficient.
EPA’s Pesticide Container Regulations: What are EPA and the States Seeing in the Field? TPSA Conference Nancy Fitz, U.S. EPA February 7, 2013.
International Maritime Dangerous Goods Training
DISPLAY FIREWORKS SEMINAR PARIS LAS VEGAS HOTEL February 21,
Hazardous Materials Performance Packaging
SUBCHAPTER C--HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT.
EPA’s Pesticide Container- Containment Regulations 40 CFR Sections to and 40 CFR Sections to Oregon OSHA Pesticide Inspector’s.
Chapter 9 Hazardous Materials. Introduction This chapter covers the following topics: Material Safety Data Sheet (MSDS) Classification of hazardous materials.
Prevention of pollution by harmful substances in packaged form
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Approvals and Permits Division Isreal Mallard Transportation Specialist,
New Jersey Regulations on Transportation of Regulated Medical Waste: Notice Of Administrative Determination Of Preemption by the Pipeline and Hazardous.
San Marino Unified School District Contracts Presentation Presented by: Wesley Lee, Budget Analyst October 28, 2015.
By Michelle Hoang Period 2 APES April 30, 2012 The Toxic Substances Control Act of 1976.
Authorization Part III. Content of a license Structure of a license General elements General and specific conditions Annexes Documents attached (e.g.
BY: Winston G. Smith Environmental Engineer UST/PCB & OPA Enforcement & Compliance Section EPA Region 4.
Agreement concerning the adoption of uniform conditions for periodical technical inspections of wheeled vehicles and the reciprocal recognition of such.
1 Introduction to Legal Inspection of Plywood Products In Taiwan A Presentation by Bureau of Standards, Metrology and Inspection, Ministry of Economic.
Lowell Randel Vice President, Government and Legal Affairs Global Cold Chain Alliance.
Anhydrous Ammonia Storage and Handling Original Power Point Created by Brandon Ritter Modified by Georgia Agricultural Education Curriculum Office June.
Portable Tanks TCIU ACROLEIN INHIBITED Acrolein Stabilized
Transportation of Dangerous Goods Heather C. Devine, Partner Morgan Jarvis, Associate.
Chapter 10 Training Package HCFC Phase-out RACSS – UNEP 2014 Refrigerant Recovery, Recycling & Cylinders.
HHW and VSQG Annual Update- DOT Hazardous Materials Compliance
Lecture (13): Hazardous Waste Management
Transportation of Class 7 materials: Compliance & Regulatory issues
Administration of a FIDIC Contract - Project Control
A Hazmat Transportation Regulatory Update
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
Special Provision 188 of IMDG Code 38-16
AIRWORTHINESS OF AIRCRAFT
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
Oleh : Ir. Sjaifuddin Thahir, MSc.
TRENTON Casing Filler Presentation
Document Development for Metro Project: Performance-based Procurement Asphalt Overlay for Programmed Maintenance 17/01/2019.
TRTR Briefing September 2013
INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC
Radiopharmaceutical Production
Presentation transcript:

EPA Pesticide Container and Repackaging Regulations, Flow Chart 3: Can I fill this small portable refillable container (capacity of 119 gallons or less)? (end notes 1 & 2) 2. Is the container included on the registrant’s description of acceptable containers for that pesticide? [40 CFR (e)(3)] The container CANNOT be refilled with the pesticide in question. 3(d) Is the pesticide a DOT hazardous material, as defined in 49 CFR 171.8? The pesticide is a DOT hazardous material.The pesticide is not a DOT hazardous material. 3(a) What DOT marking is required? The UN symbol and the DOT marking, which includes 6-8 pieces of information (end note 3) including the: - Container code in the first slot - Packing Group (X, Y or Z) in the 2 nd slot [49 CFR ] (Also see end note 4.) 3(b) What DOT inspections are required? -The container must be in such condition that it is capable of passing all performance tests represented by the markings. [§173.28(a)] - Metal and plastic drums and jerricans (end note 5) must meet the minimum thickness requirements. [§173.28(b)(4)] - Metal and plastic drums and jerricans must be marked in a permanent manner (embossed) with the nominal thickness (for metal containers) or minimum thickness (for plastic containers) in mm. [§173.28(b)(4)] 3(e) What DOT testing is required? Before each reuse, has the container passed the DOT leakproofness test with air in accordance with § and marked with: (1) the letter “L”; (2) the name & address or symbol of the person conducting the test; and (3) the last 2 digits of the year the test was conducted? [49 CFR (b)(2)] The container must be leakproofness tested per 49 CFR and marked with the information required by §173.28(b)(2)(ii) unless all of the conditions in §173.28(b)(7) are met. (end note 6) No DOT testing is required if the container and refiller comply with EPA’s container and repackaging requirements. [40 CFR (a)(2)] (end note 7) NO YES NO YES Flip page over 1. Is the container labeled as a nonrefillable container or a refillable container? The container CANNOT be refilled or reused. Nonrefillable container Refillable container Before each reuse, the container must be inspected and may not be reused unless it is free from incompatible residue, rupture, or other damage which reduces its structural integrity. (No marking or recordkeeping of the inspection is required.) [49 CFR (a)] A container that shows evidence of a reduction in integrity may not be reused unless it is reconditioned in accordance with §173.28(c). [49 CFR (b)(1)] 3(c) What other DOT requirements must be met for the container to be able to be reused? April 27, 2012 YES NO

5. Does the container pass the EPA inspection each time before it is refilled? 5(a) Is the container compromised by showing signs of rupture, cracks, significant defects or damage that might render it unsafe for transportation? [40 CFR (f)(1)] (end note 8) The container fails the inspection and cannot be refilled. It must be removed from service until it is repaired, reconditioned, or remanufactured to be in compliance with the relevant DOT requirements. 5(b) Is the container durably marked with a serial number/ identifying code and any required DOT marking AND is all of the marking legible? [40 CFR (f)(2)] The container must be retrofitted so all of the required marking is durable and legible. (end note 9) 6. Are vents designed to minimize the amount of material that can be introduced into the container through the vent? [40 CFR (e)] The vent must be retrofitted so it would be difficult to put material through the vent into the container, which includes ensuring that the vent device is not easily removed. 7. Does each opening (other than a vent) have a one-way valve OR a tamper-evident device OR both (or will have one after the container is filled)? [40 CFR (e)] A one-way valve or a tamper-evident device must be installed on each opening (that is not a vent) before the container is released for shipment. 8. Does the container need to be cleaned? (end note 10) 8(a) Were all of the container’s tamper-evident devices and one-way valves intact when the refiller received the container? [40 CFR (g)(1)] 8(b) Is the container being refilled with the same pesticide product (as determined by the label)? [40 CFR (g)(2)] 8(c) Is the container being refilled with a pesticide that has the same single active ingredient in a compatible formulation? [40 CFR (g)(3)] The refiller must clean the container using the cleaning procedure from the registrant of the pesticide being repackaged into the container. The container does not need to be cleaned. NO YES NO YES NO YES NO YES NO YES 4. Is the container durably marked with a serial number or other identifying code? [40 CFR (d)] The container must be durably marked with a serial number or other identifying code. YES NO

End Notes: (1) The volume of 119 gallons is based on the Department of Transportation (DOT) regulations and specifically the cutoff between non-bulk and bulk packagings. This document covers non-bulk packagings. (49 CFR 171.8) (2) This flowchart is intended to provide general guidance. See the regulations in 40 CFR Part 165 for complete details. This flow chart is based on the scenario that a refiller at a registered producing establishment (40 CFR Part 167) has a portable refillable container to be filled with a specific pesticide and is trying to determine how to do that in compliance with the refillable container and repackaging regulations. The scenario assumes that: (a) the facility complies with all of the repackaging regulations in 40 CFR – (such as having entered into a contract with the pesticide’s registrant); (b) the pesticide is subject to the refillable container and repackaging regulations (e.g., it is not a manufacturing use product or an antimicrobial product that meets all of the criteria for exemption); and (c) the container is subject to the refillable container and repackaging regulations because it is being used to sell or distribute the pesticide (e.g., it is not a service container, which is when an applicator transfers a pesticide into the container for the purposes of that applicator applying the pesticide). (3) The rest of the information in the DOT marking includes the designation of the specific gravity or mass for which the packaging design type has been tested; the hydrostatic test pressure successfully passed for packagings intended to hold liquids; the last 2 digits of the year of manufacture; the country authorizing allocation of the mark; the name & address or symbol of the container manufacturer; and the nominal or minimum thickness for metal or plastic drums or jerricans intended for reuse or reconditioning. [49 CFR (a)] Additional information must be marked on reconditioned packagings. [49 CFR (c)] (4) All portable refillable containers that are 119 gallons or smaller must be marked with the UN symbol and DOT marking. EPA’s regulations in 40 CFR (a)(1) refer to and adopt 49 CFR for pesticides that are not DOT hazardous materials, which lists the authorized non-bulk packagings for liquid hazardous materials in Packing Group III. All of the non-bulk containers identified in 49 CFR must be designed, tested and marked to comply with DOT’s requirements at the Packing Group III level (at least). In other words, there is no exception for the non-bulk containers like there is for non-DOT Specification portable tanks in the larger size category. (5) Jerrican means a metal or plastic packaging of rectangular or polygonal cross-section. Drum means a flat-ended or convex-ended cylindrical packaging made of metal, fiberboard, plastic, plywood, or other suitable materials. (49 CFR 171.8) (6) 49 CFR (b)(7) includes the following exception to the requirement to leakproofness test before each reuse: Notwithstanding the provisions of paragraph (b)(2) of this section, a packaging otherwise authorized for reuse may be reused without being leakproofness tested with air provided the packaging— (i) Is refilled with a material which is compatible with the previous lading: (ii) Is refilled and offered for transportation by the original filler; (iii) Is transported in a transport vehicle or freight container under the exclusive use of the refiller of the packaging; and (iv) Is constructed of— (A) Stainless steel, monel or nickel with a thickness not less than one and one-half times the minimum thickness prescribed in §173.28(b)(4); (B) Plastic, provided the packaging is not refilled for reuse on a date more than five years from the date of manufacture marked on the packaging in accordance with § (a)(6); or (C) Another material or thickness when approved under the conditions established by the Associate Administrator for reuse without retesting. (7) EPA’s regulations (40 CFR (a)(2)) state that a refiller is not required to comply with the leakproofness test (and associated marking) in 49 CFR (b) for pesticides that are not DOT hazardous materials if the refillable container complies with EPA’s refillable container regulations and the refilling is done in compliance with EPA’s repackaging regulations. (8) The citations for EPA’s repackaging regulations are from the section for “independent” (non-registrant) refillers in § There are comparable requirements for registrants who are refillers in § (9) You cannot add the UN symbol or DOT marking to a container unless you have the required test data. DOT regulations state that a container “may be marked with the United Nations symbol and other specification markings only if it fully conforms to the requirements of” 49 CFR Part 178. (49 CFR 178.3(b)) (10) The questions regarding cleaning in #8 assume that the container had previously been used to sell/distribute a pesticide and is received by the refiller with the label of that pesticide still on the container. 9. The container can be refilled with the registrant’s pesticide. After refilling the container, the refiller must take the following final actions: Close the fill port according to the container manufacturer’s instructions and seal the fill port with a tamper-evident device OR a one-way valve OR both. [49 CFR (f)(2) and 40 CFR (e)] Ensure that the label of the pesticide is securely attached to the container and complies with all label requirements, which includes:  Adding the net contents and the refiller’s EPA Establishment number (if not on the label); and  Having the new refillable container instructions, including language like “Refillable container. Refill this container with pesticide only. Do not reuse this container for any other purpose.” [40 CFR (i) & – ] Record the date of repackaging, the container serial number/identifying code and the EPA Registration number of the pesticide and keep that record for three years. [40 CFR (j)(2)] For more information: - See the pesticide container regulations (40 CFR Part 165) or - EPA’s container web page: - Contact Nancy Fitz, ,