` ACEEE HOT WATER FORUM ACT D’MAND KONTROLS® SYSTEM February 16 th 2015 PRESENTED BY LARRY ACKER “Designed for today, Dedicated to the Future®”. 1.

Slides:



Advertisements
Similar presentations
“The Major Breakthrough In Hard Water Treatment Technology”
Advertisements

The value in mechanical & electrical retrofits What Pays and what Doesnt? What Pays and what Doesnt? June 16, 2011 June 16, 2011 Mark Kesseler Mark Kesseler.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
MAGNA3 – “built on a proven foundation”
TYPES OF MECHANICAL SYSTEMS
1 Energy Efficiency By Flexx Rantoa. 2 Where to save.
INTD 51 human environments building systems. heating/ventilation/air-conditioning (HVAC) maintain a comfortable indoor climate control temperature and.
ENERGY CONSUMPTION: MANZANITA HALL ENERGY UPGRADES BEN COHNDANNY GARNETT AUSTIN FROGGEPAUL SAIGEON MATT DUNCAN.
Janie Harris, Extension Specialist Housing and Environment.
Hot Water Recirculation Pumps. Tim Pehl Outside Sales Rep For Dawson Company. Outside Sales Rep For Dawson Company.
Booster System Basics: Constant Speed Systems
Active Solar Heating Liquid Solar Heating System Travis Ricard.
Peter Duby, Pepperdine University Gabriel Ayala, Enovative Group Inc.
©2007 Armstrong International, Inc. Instantaneous Water Heater Flo-H 2 0 ™ Water to Water Instantaneous Water Heater Flo-H.
Engineer Presentation
Grid-interactive Renewable Heating Paul Steffes Steffes Corporation
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
DEPT OF ESTATES AND FACILITIES Engineering Team DEPT OF ESTATES AND FACILITIES Engineering Team Too hot, too cold, just right Presented by: Russell Smith.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
`RESIDENTIAL ACEEE HOT WATER FORUM ACT D’MAND KONTROLS® SYSTEM February 16 th 2015 PRESENTED BY LARRY ACKER “Designed for today, Dedicated to the Future®”.
ENERGY SOURCES. ALTERNATIVE ENERGY SOURCES Geothermal Energy comfort… savings... environment.
Domestic Electric Heating Chris Davis Marketing Manager, Glen Dimplex UK Electrex – 17 th May 2006.
Hydronic Mechanical Controls
Air and Ground Source Heat Pumps A presentation by Alan Westlake – Programme Manager (RHA) and Jeremy Pallant – Director Greensave.
Mayflower Hill House Energy Audit May 8, 2015 Compiled by: George Voigt ’17, Danqing Zhao ’17, Kel Mitchel ’16, Emma Reif ’16, Savannah Judge ’15, Evan.
Danish Gas Technology Centre T E C H N O L O G Y F O R B U S I N E S S 1WGC 2006 Amsterdam Natural Gas Technologies in the House of Tomorrow Bjarne Spiegelhauer.
1 MAGNA3 RANGE RELIABILITY INTELLIGENCE EFFICIENCY.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
HVAC523 Basic Subsystems.
Northeast and Mid-Atlantic States Regional Low Carbon Fuel Standard Stakeholder Meeting
Green Building Demonstration Project Adam Saling City of San Diego.
1 © Copyright DWT GROUP 1 DWT reserve the right to make modifications without prior notice.
Weatherization 201: Weatherization Works! Updated September 23, 2008.
Stratos ECO Training ECM “Smart” Circulators for Heating, DHW Recirculation Systems Presentation Date – New Jan 2008 ECO 16 FECO 16 FX ECO 16 BFX Stratos.
Name of Building(s) or Project Speaker(s) Organization(s)
Lecture Objectives: Finish with example modeling problems –Phase change thermal storage materials –Energy and airflow Interpret energy simulation results.
1 Oconomowoc Area School District Energy Update 6-Month Status Report December 2005 – May 2006.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Industry Questions on Applying a LCFS to Residential Heating & Hot Water Systems How does a LCFS interact with current and future Federal, regional and.
Kendal at Oberlin Energy Conservation & Sustainability Initiatives.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
HYDRO MULTI-B – Pressure boosting made simple.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
UNIT 2 SOLAR WATER HEATER AND SOLAR PHOTOVOLTAICS.
California Energy Commission Funded Research Project
CITY OF LEOMINSTER. Customer Charge The cost of providing customer related service such as metering, meter reading and billing. These fixed costs are.
What is Voltage Optimisation? Voltage optimisation is a generic term given to the managed reduction of voltages received from a supplier down to a value.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
One of the most advanced products of its league, this Pressurized Solar Water Heater System combines the stainless steel heat exchanger pipes and water.
Longmeadow: Cost-Benefit Analyses for Sustainable Projects Mara McPartland and Claiborne Dingledine - Climate and Energy Solution Analysis, December 2009.
Keeping water hot is a considerable ongoing expense for most homes - next to heating and cooling the house itself, heating water is the biggest energy.
Domestic Hot Water Recirculation Design
Instant hot water. Long-term savings.
Fan Coil Controller FC/S 1.1
Energy Efficient Building Components
Section 6: Air-Conditioning (Heating And Humidification)
HYDRONIC HVAC: The Most Comfortable and Efficient System
GEYSER Heat Pump Water Heater
HYDRONIC HVAC: The Most Comfortable and Efficient System
Traditional Water Booster System
Hot water Systems Heaters.
Hot Water Systems Cylinders and Systems.
The key to comfort and efficiency for heating and air-conditioning
Domestic Hot Water Recirculation
Domestic Hot Water Recirculation
Presented by Mike Zacharias
Presentation transcript:

` ACEEE HOT WATER FORUM ACT D’MAND KONTROLS® SYSTEM February 16 th 2015 PRESENTED BY LARRY ACKER “Designed for today, Dedicated to the Future®”. 1

TWO TIMES A RECIRCULATION PUMP SHOULD NOT RUN, 1) NO DEMAND FOR HOT WATER. 2) IF HOT WATER IS ALREADY IN THE SYSTEM.

DEMAND CONTROLS There are certain cases where Demand Controls that allow the hot water flow to stop will not work. 1) Cross connections. This occurs in areas like showers, washing machines and bad plumbing. 2) Hot water pumping used for Hydronic heating. 3) Vertical buildings that have booster pumps systems to maintain water pressure.

Water Heater Losses End-Use Energy 40% 30% Branch Losses Recirculation Loop Losses Hot water supply Hot water return Cold water supply Mechanical Room Branch DHW System Energy Flow 45% 29% 1% 25% Distribution Losses

Demand activation- flow switch Ultra-sensitive flow switch detects demand anywhere in the building and sends a signal to the pump

FLOW SWITCHES Can create false readings up to 60 or more times a day. Start up of electric pumping systems is maximum power. Internal or inline flow switches may create failure issues, either mechanical or deterioration.

The Repercussions of Using Flow Switch

FACTS The U.S. Environmental Protection Agency’s “Green Lights” program says that electricity is linked to air quality or Carbon Footprint. On Average, every Kilowatt-hour of electricity saved “prevents the emission of # 1.5 POUNDS OF CARBON DIOXDE # 5.8 PGRAMS OF SULFUR DIOXIDE # 2.5 GRAMSW OF NITROGEN OXIDES

Palm Springs: 12 Unit Complex Average Savings 14% Boiler Reduction 99% Energy Reduction 5% Water Savings

3/21 The Problem A Typical Central Water Heating System 2) Is heated to Approximately 140 ℉ 1)City cold water supply 3) Hot water is continuously circulated throughout the building from the storage tank 4)Pipes lose significant heat into the surrounding environment as hot water is continuously circulating 5) When water returns, it is much cooler and these heat losses must be made up, resulting in excessive gas usage. This is occurring 24/7, whether or not anyone is actually using hot water Some of the suspicious files suitable for analysis have not been approved for submission yet. To open an approval window, click on this message.

D’MAND CIRC® is Cost Effective Boiler run time before and after Studies conducted by the C.E.C. and So Cal Gas Co. confirm the energy saving effectiveness.  Average gas savings: therms annually  Average electricity savings: kWh annually  Average payback: 8-18 months The D’MAND Circ® provides greater gas savings than most other alternative measures

The Solution: D’MAND CIRC® ‘Brains’: -patented circuit board -uses sensors to pump on demand D’MAND® Circuit Board Sensor Connections Power Plug Reduced pump run time results in: Less gas used by boiler Less electricity used by pump Less wear and tear on pipes -water heater runs less -reduces hot water corrosion on pipes (less leaks, re-piping, water damage) Running the re-circ pump on D’MAND ® only pumps when necessary! Office or administration building Dormitory or other multi- unit dwelling HospitalSchool Retrofits into any existing building, including:

Benefits of D’MAND® Controlled Circulation in Multifamily Buildings Reduced Gas Use Heat loss in pipes causes boiler to reheat unused water Reduced Electricity Use As compared with pumps that run 24/7 Less wear and tear on pipes Aids in the reduction of costly pinhole leaks Increased pump life May run as little as 20 min per day without hot water disruptions or delays

Using Demand Controls at the End of a Twig and on the Distribution Loop Multiple demand units can be used in large buildings where the pipe branches are so long that there is a significant wait for hot water, regardless of recirculation on the trunk line. This combines the method used in a commercial building with the retrofit application of demand controls in single family homes with no return line. This is the most sustainable retrofit method for large buildings with long branches that won’t be served by the main recirculation loop or trunk. Use Demand controls on the existing recirculation loop to increase efficiency of the trunk line Use Demand controls at the end of each twig to create new vertical loops to reduce the wait time for hot water

Remote Sensor

Overview With the Grundfos ALPHA, you can stop worrying about complicated pump settings. Simply install the pump and leave it on the factory setting AUTOADAPT. The ALPHA will automatically analyze the heating system, find the optimum setting and continue to adjust its operation to changes in demand. With its permanent magnet motor design, this energy efficient circulator will reduce power consumption up to 80 %. Ensuring lowest possible energy consumption without sacrificing comfort.

Applications The Grundfos ALPHA is designed for circulating liquids in light commercial and residential heating systems. Available in cast-iron pump housings for closed systems or stainless steel housings for open or domestic hot-water systems. The Grundfos ALPHA is suitable for Systems with constant head requirements Systems with variable head and or flow requirements Fixed speed requirements Features and benefits Compact permanent magnet maintenance-free wet rotor technology Nut capture flanges Available with integrated terminal box or line cord option Simple one button hydraulic selection Seven hydraulic selections available – Three fixed speeds options – Three constant pressure options

MADE IN AMERICA

COMMERCIAL/MULTI-FAMILY ACT D’MAND CIRC® SYSTEMS