Veterinary Radiation Safety 4 Students Radiation Safety MA Law requires that persons who perform diagnostic radiology procedures on animal patients be.

Slides:



Advertisements
Similar presentations
Radiation safety in CT.
Advertisements

Radiation biology and protection in dental radiology
Radiation safety in CT.
Radiation Safety/Protection
Radiation Safety Training for Fluoroscopy in Research Radiation Safety Office Indiana University Purdue University Indianapolis and Associated Facilities.
State of Michigan Computed Tomography Regulations
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
Radiation Safety & Compliance External Beam –Electrons (linacs) –Photons (linacs, Gamma Knife) –Protons (Summer 2013) Brachytherapy –Sealed Sources –Radiopharmaceuticals.
Radiation Safety Reminders During Nuc. Med. Procedures ALARA Practices By Aggie Barlow, CHP, MBA, MS.
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
CVT 102.  Time  Distance  Shielding.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Veterinary Radiology Safety and Procedures. What is a radiograph? When an xray beam (a form of electromagnetic radiation) penetrates tissue to form a.
Basic quality control tests in medical radiography
RADIATION SAFETY Phil Facey Lead Superintendent Radiographer
Biological response and radiation safety practices
Chest X Ray. How Do They Work? They are a form of electromagnetic radiation. X-rays have high energy and short wavelength and are able to pass through.
Personal Radiation and Occupational Safety – CT Policy This policy is in both paper form in the lab’s compliance manual, and on a Power Point presentation.
Dental Assisting Radiology
Quality Control Rad T 110.
Introduction to Fluoroscopy & Radiation Safety
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
Radiation Safety Reminders During Nuc. Med. Procedures ALARA Practices By Aggie Barlow, CHP, MBA, MS.
CONCEPTS OF RADIOLOGIC SCIENCE. Mass and Energy Mass is a measure of the amount of matter contained in or constituting a physical body.
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Chapter 3 Radiation Safety Vet Tech Institute. Radiation should be respected not Feared! Safety is Always important! Safety is Always important! Stray.
UNIT 6 Introduction to Radiation Protection
Radiation Monitoring and Protection
Northern California SGNA Meeting September 22, 2012.
Measures to Support Safety in Dental Radiography Pamela Alston, DDS, MPP Lead Oral Health Specialist.
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
1 DA105 RADIOLOGY RADIATION HEALTH AND SAFETY – Radiation Control for Health and Safety Act – Standardized xray equipment; required filtration,
RT 123 INTRODUCTION & Review of Radiation Protection (Merrills Ch. 2)
HEALTH PHYSICS TERMS l RAD (Gy) l mRad l R l mR l Rem l ALARA l NCRP.
RADIATION SAFETY Mrs. Brinston. Introduction As a healthcare worker, you know that radiation is an important tool for detecting and treating diseases.
Basic radiation protection & radiobiology
Extremity Dose Reduction By Aggie Barlow, CHP, MS, MBA.
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Rad T 110 State Syllabus for Radiation Protection.
Radiation Sources in medicine diagnostic Radiology
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
Week 2 :Radiation Protection
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Radiation hazards Mamoun Kremli, SA AOT Basic Principles Course.
Chapter 4.  All ionizing radiation is harmful and produces biologic changes in living tissues.  Although the amount of x-radiation used in dental radiology.
Radiation Dosimeters.
Week 2: Radiographic Equipment
X-RAY IMAGING INTENSIFIER
Protection1 Radiation Protection. Protection2 BENEFITS VS. ADVERSE EFFECTS.
Week Seven.
AJADI ADETOLA DEPARTMENT OF VETERINARY MEDICINE AND SURGERY.
RADIATION PROTECTION 04/12/2016.
Patient & Occupational radiation dose management Chapter 37 & 38
Radiation Protection RTMR 284 CHAPTER 21.
Stat Ch 8 & 9 RHB – Rad Prot Syllabus
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
RADIATION PROTECTION Salman Albeshan.
Radiation Safety.
RADIATION PROTECTION.
Radiation Badge Training
Radiation Safety Lavin: Chapter 16 CTVT:
RADIATION TERMS AND UNITS
Pediatric Fluoroscopy
Mobile Fluoroscopy Based on:
Pediatric Fluoroscopy
Pediatric Fluoroscopy
Mobile Fluoroscopy.
Radiation Badge Training
Presentation transcript:

Veterinary Radiation Safety 4 Students

Radiation Safety MA Law requires that persons who perform diagnostic radiology procedures on animal patients be adequately trained in equipment operation and radiation safety principles.

Authorization to take a radiograph at Tufts Radiology Examinations must be ordered by a Tuft’s Veterinarian or Resident. Veterinary equipment must not be used for human exams.

First Things First Identify your patient. Take into consideration similar breed animals, especially in large waiting rooms. Ask the owner to identify the patient.

Repeat Radiographs The National repeat rate for radiographs is ~8 %. Each repeat radiograph is additional radiation dose to the patient and staff. Watch the patient closely through the control room view window. If the patient has moved or is no longer in the correct position, do not take the exposure. Reposition or restrain again to ensure the radiography does not have to be repeated.

Prior Radiograph Viewing Viewing prior radiographs, especially for orthopedic studies, can dramatically reduce the repeat rate for radiographs. Whenever possible, view original orthopedic radiographs before performing another examination.

What Else Can You Do? Close collimation reduces patient’s and staff’s exposure dose.

Technical Factors Use of higher Kvp WITH AN APPROPRIATE REDUCTION IN mAs results in less radiation dose. However, Kvp must be appropriate for the study. Ex. For an Lateral Chest Radiograph mAs results in less dose than mAs.

Imaging Use of faster film/screen combination [consistent with the requirements of the examination] also reduces dose. Proper photo-timing can also reduce radiation exposure. Be sure the sensors are properly centered for the organ/part of interest. Careful alignment of the x-ray beam with the patient and image receptor is vital.

Filtration Do not remove filtration from x-ray tubes. Tubes must have aluminum filtration to remove the “soft” x-rays that do not produce the radiographic image. MA Law requires at least 2.5 mm Al filtration for most x-ray units.

Holding Patients Use approved mechanical restraining devices to hold other patients whenever possible. MA Law allows adults to hold patients if necessary. If you hold a patient, wear a lead apron and gloves. Keep out of the primary beam. Direct the x-ray tube away from you. Do not point the tube at the control booth.

Whenever possible, use sandbags and other restraints instead of having persons hold patients

Wear Lead apron, thyroid shield and gloves. Do not hold patients for bucky exposures – only for table top exams on small animals.

Use equipment or sedation to restrain large animals for exams that use the bucky tray

Shielding – stand completely behind the control booth lead wall during x-ray exposures

Restricting Access to X-ray Rooms Allow no unauthorized visitors during x-ray exams. MA Law states that “only individuals required for the radiographic procedure shall be in the radiographic room during exposures; and except for the patient, no unprotected body parts of their bodies shall be in the useful beam.”

Fluoroscopy equipment Fluoroscopy delivers a dose of approximately 5 Rads per minute. Fluoroscopy should not be used by veterinary technologists as a substitute for radiography. [Ex. Do not fluoro when a conventional radiograph was ordered just to avoid complex positioning.]

Fluoro equipment continued Do not remove lead drapes which provide shielding and reduce scatter radiation reaching the operator. Ensure fluoro is energized only when a veterinarian is actively looking at the fluoro image. Use of intermittent fluoro reduces patient and operator exposure.

Wear a lead apron during fluoro 0.5 mm lead equivalent for fluoro aprons - “wrap around” style aprons are best.

Portable Radiography Wear lead apron, thyroid shield and gloves. Ensure animal is calm and as still as possible. Use long handled cassette holders. No worker should be in the direct beam. Do not direct the x-ray beam at a corridor or into an area where others may be exposed inadvertently. Stand as far from the x-ray tube and patient as feasible.

Portable X-ray Unit Use the fastest imaging system possible. Close collimation reduces scatter radiation and helps keep your radiation exposure low. Do not hold the x-ray machine during exposures. Use the exposure control cord to step 6’ away from the x-ray machine during the exposure.

Reporting problems Report any changes in technical factors and keep a technique chart up to date. Remove from service any x-ray equipment that appears to be malfunctioning. Contact your supervisor and repair personnel.

X-ray Production

Radiation Biology Even small doses of radiation can damage DNA. Very large doses of radiation [>100 Rem] can cause health effects.

Typical Large Patient Doses for Common Exams – skin entrance doses DV Chest10 mRem DV Abdomen325 mRem Head CT2000 mRem Paw 6 mRem Knee 20 mRem Shoulder 25 mRem Lat skull 70 mRem

MA DPH Occupational Dose limits MA has annual worker dose limits to ensure worker safety. Whole body limit mRem/yr Dose to typical Techs - < 100 mRem/yr

Radiation Badges All badges are NVLAP certified to ensure maximum accuracy of the dose report. Wear the badge flat against your body. Do not wear badges on a chain, which would allow the badge to turn at various angles as you work.

Remember to: Wear only your own badge Wear it whenever working at Tufts Univ. Leave it in a cool, dry place away from radiation when not in use Do not take your badge home. Do not launder the badge or get it wet. Do not expose to heat, such as in a car in summer. Do not open badge. Do not expose the badge to other sources of radiation. Do not wear the badge for personal x-ray or nuclear medicine exams. Turn in your badge for processing in a timely manner.

Pregnant Radiation Workers Pregnant Rad. Workers must be limited to 500 mRem/9 months. Tufts goal is to have the exposures < 50 mRem/ 9 mos. Extra badges to wear at the waist are available to pregnant radiation workers who declare the pregnancy.

Controlling External Exposure Time,Distance & Shielding & Shielding

Time – make sure the fluoroscopist knows the total fluoro time- Only required people should be present

Distance - stand as far away from the patient during fluoro as feasible. When not assisting, stand in the control booth.

Shielding Properties – most radiography rooms require 1/16 inch of lead

Lead aprons to protect staff All workers in the x-ray room during studies must have a lead apron. Keep the lead between you and the x-ray tube. That is, do not turn your unshielded back to the x-ray machine. Use of wrap around style aprons is best.

Thyroid Shield Use of a thyroid shield keeps worker’s radiation dose ALARA [as low as reasonably achievable.]

Lead Shield Care Hang aprons and shields on racks. Do not bend or fold lead aprons or shields. Folding can cause cracks and tears in the protective material. Periodically inspect shields for evidence of damage. Remove damaged ones from use.

Additional Radiation Related information

Types of Radiation Radiation can be non ionizing such as lasers or microwaves, or Radiation can be ionizing such as x-rays

Radiation can be particulate or electromagnet. Particulate radiation has mass. Electromagnetic radiation is a mass-less packet of energy called a photon.

Particulate Radiation

Electromagnetic Radiation

Sources of Radiation Radiation can be naturally occurring such as radon and cosmic rays. Radiation can be man made, such as x-rays.

Consumer Products as radiation sources

ALARA As Low As Reasonably Achievable Using good safety practices each day, every study, to keep your and your patient’s radiation dose as low as feasible.

For Further Information Contact : Your supervisor, or the Tufts Office of Environmental Health and Safety at