Trace metal analysis in carbonates using the Cameca NanoSIMS John Eiler Sharp Professor of Geology and Geochemistry Director, Caltech Microanalysis Center.

Slides:



Advertisements
Similar presentations
Crag Cave Study A look into the past Dillon Dolezal Undergrad Geology Major NDSU Geol 428 Geochemistry 2010.
Advertisements

ON WIDTH VARIATIONS IN RIVER MEANDERS Luca Solari 1 & Giovanni Seminara 2 1 Department of Civil Engineering, University of Firenze 2 Department of Environmental.
May 4, 2015Kyle R. Bryant Tutorial Presentation: OPTI521 Distance 1 MTF Definition MTF is a measure of intensity contrast transfer per unit resolution.
AMCF Materials Characterization School 2012 X-Ray Photoelectron Spectroscopy Tim Morgan.
Rapid and precise determination of natural carbonate rare earth elements in femtogram quantities by ICP-SF-MS (Chung-Che Wu and others) A rapid and precise.
Corals as paleoclimatic archives Jens Zinke PROPER June 2004, VU Amsterdam.
3rd PaleoSalt Meeting, Angers, June 2008 WP2: Mass Spectrometric Analysis of the Elemental and Molecular Composition of Calcite Samples and an.
General model for calcite growth kinetics in the presence of impurity ions (Nielsen, DeYoreo, DePaolo; 2013) Scientific Achievement A single model employing.
EPOCA Kick-off Meeting June 2008: Nice Theme 1Ocean chemistry and biogeography What is the past and recent variability of ocean carbonate chemistry (including.
XPS and SIMS MSN 506 Notes.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
Geostatistical structural analysis of TransCom data for development of time-dependent inversion Erwan Gloaguen, Emanuel Gloor, Jorge Sarmiento and TransCom.
ED and WD X-ray Analysis
Biomedical Tracers Biology 685 University of Massachusetts at Boston created by Kenneth L. Campbell, PhD.
Some Potential Terrain Analysis Tools for ArcGIS David G. Tarboton
Cycling of Ocean Micronutrients: What do we Know and What do we Need to Know? Ed Boyle Earth, Atmospheric and Planetary Sciences Massachusetts Institute.
MiniSIMS Secondary Ion Mass Spectrometer Dr Clive Jones Millbrook Instruments Limited Blackburn Technology Centre, England
Iron isotope constraints on Fe cycling and mass balance in oxygenated Earth oceans Brian L. Beard, Clark M. Johnson, Karen L. Von Damm, Rebecca L. Poulson.
Paper Number OS 26A-06 At both sites, the majority of the vertical flux attenuation of components such as carbon occurred with the mesopelagic “Twilight.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Typical chronometers. LA-ICPMS and SIMS challenges from ~
Open Oceans: Pelagic Ecosystems II
Quality assurance of sampling and analytical instruments
ITAM CAS, IEAP CTU IWORID 2004Glasgow, th July IWORID 2004 OPTIMIZATION OF X ‑ RAY DYNAMIC DEFECTOSCOPY USING MEDIPIX-2 FOR HIGH FRAME RATE READ-OUT.
Results of the WMO Laboratory Intercomparison of rainfall intensity gauges Luca G. Lanza University of Genoa WMO (Project Leader) DIAM UNIGE September.
Intro to Geomorphology (Geos 450/550) Lecture 5: watershed analyses field trip #3 – Walnut Gulch watersheds estimating flood discharges.
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
Climate Data and Paleoclimate Proxies Ruddiman p , Appendices 1 and 2 Paleoclimate at NOAA.
Performance characteristics for measurement and instrumentation system
An evaluation of HotSpot-3.0 block-based temperature model
Measurement of “Difficult” Elements and Isotopes Using a Hexapole ICPMS Zenon Palacz, Simon Meffan-Main. Micromass U.K. Ltd.
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Quantification Techniques Under Dynamic SIMS 1 Secondary Ion Mass Spectrometer Start-Up Project Overview Secondary Ion Mass Spectrometry Overview MiniSIMS:
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
Backscattering Lab Julia Uitz Pauline Stephen Wayne Slade Eric Rehm.
High Precision Pb Isotope Ratio Measurements of Zircon Zenon Palacz, Simon Meffan-Main, Patrick Turner, & Fadi Abou-Shakra.
For all CHEM5161 students: The first day of class for CHEM5161 (Analytical Spectroscopy) will be on TUE Sept 4 (following Labor Day). There will be no.
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Imaging Molecular Gas in a Nearby Starburst Galaxy NGC 3256, a nearby luminous infrared galaxy, as imaged by the SMA. (Left) Integrated CO(2-1) intensity.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
COSIRES 2004 © Matej Mayer Bayesian Reconstruction of Surface Roughness and Depth Profiles M. Mayer 1, R. Fischer 1, S. Lindig 1, U. von Toussaint 1, R.
X-Ray Microanalysis – Precision and Sensitivity Recall… wt.fraction I = I SiKα (unknown) / I SiKα (pure std.) K-ratio I = [I SiKα (unknown ) / I SiKα (std.)
1 Blend Times in Stirred Tanks Reacting Flows - Lecture 9 Instructor: André Bakker © André Bakker (2006)
Spatial Smoothing and Multiple Comparisons Correction for Dummies Alexa Morcom, Matthew Brett Acknowledgements.
Ion Beam Analysis of the Composition and Structure of Thin Films
Design options for emittance measurement systems for the CLIC RTML R Apsimon.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
A confocal Raman microprobe analysis of partial discharge activity in gaseous voids N A Freebody 1*, A SVaughan 1, G C Montanari 2 and L Wang 2 1 University.
N A S A G O D D A R D S P A C E F L I G H T C E N T E R I n s t r u m e n t S y n t h e s i s a n d A n a l y s i s L a b o r a t o r y APS Formation Sensor.
Silicates dissolution during interaction with sea-water and its potential contribution to the isotopic composition of Sr in the oceans Daniel Winkler (1),
Hiden Compact SIMS Mass Spectrometry in solid material.
Radiometric dating and sediment accumulation rates Dating principles – covered in Isotope Geochemistry (Faure) Two radiocarbon approaches: Average slopes.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Spatial Resolution and minimum detection
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
What is XPS? XPS (x-ray photoelectron spectroscopy) is also known as ESCA (electron spectroscopy for chemical analysis). XPS provides chemical information.
NANO 230 Micro/NanoFabrication
Study of scattering points on LIGO mirrors
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Preface: What’s EPMA all about? How does Geology 777 work?
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
HPS Collaboration meeting, JLAB, Nov 16, 2016
First use of clumped-isotope thermometry to quantify temperatures of crystallization for diagenetic calcite Katharine W. Huntington Department of Earth.
A Bacterium That Can Grow by Using Arsenic Instead of Phosphorus
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Slope measurements from test-beam irradiations
Introduction to Analytical Chemistry
Electron probe microanalysis
Presentation transcript:

Trace metal analysis in carbonates using the Cameca NanoSIMS John Eiler Sharp Professor of Geology and Geochemistry Director, Caltech Microanalysis Center California Institute of Technology With contributions from Jess Adkins, Anne Dekas, Rinat Gabitov, Alex Gagnon, Amy Hofmann and Katie Snell Wisc SIMS Paleoclimate Workshop June 25 th, 2013

Mitsuguchi et al., 1996 CaCO 3 + Mg aq = MgCO 3 + Ca aq K eq ∞ Mg Ca Mg [ ] min [ ] fluid x Cation-exchange paleothermometry

Stanley and Hardie, 1998; model of Hardie, 1996 Global budgets Weathering Hydrothermal Sediments Alteration

Eggins et al., 2004; Hitch #1: Vital effects Gagnon et al., 2007 Foraminifera Deep-sea coral

Allison et al., 2007 Hitch #2: Diagenesis PA: Primary Aragonite; SA: Secondary Aragonite; SC: Secondary Calcite Cements vs. ‘Primary’

The Cameca NanoSIMS

Geometry of focusing and extraction lenses What puts the ‘nano’ in nanoSIMS Short working distance promotes small, dense probe Extraction optics easily contaminated or damaged

Minimum spot size Nominally 50 nm for Cs +, 150 nm for O - (‘84/16 %’ definition) Actual minimum ca. 20 nm for Cs +, ca. 100 nm for O - Brighter beams needed for trace element mapping typically in nm range Actually tricky to measure in many samples; assume it is ~500 nm unless proven otherwise 1 µm Si metal in Al matrix <<1 pA Cs+; ca. 30 nm resolution Illustration of the ‘84/16 %’ definition

Connection between beam current and resolution Images sharpen by minimizing beam current and carefully tuning primary beam Count rates decrease and errors increase in proportion to beam current TiCN; Cs+ primary beam 2 pA; 93 nm resolution TiCN; Cs+ primary beam <<1 pA; 22 nm resolution 1 µm

Work of Amy Hoffman Even carefully tuned images ‘broaden’ features you can see clearly by SEM Sub-micron rutile inclusion in zircon

High-dispersion multi-collection The analyzer and detector array of the nanoSIMS are also distinctive Minimum mass spacing—1:58 Maximum mass spacing —22:1 Conceived of as a tool for elemental mapping with exact spatial correlation of measured species Also enables true multi-collection of almost any element/element ratio Fixed collector Six mobile collectors

Transmission and mass-resolving power Data from CIT nanoSIMS 50L; image from Frank Stadermann Relative sensitivity (%) Mass resolving power Absolute sensitivity comparison

Design purpose: Composition mapping at µm scale Field of view: 200x200 µm in principle; 20x20 in practice. 10x10 or 5x5 is ideal Discretization: 64x64 to 1024x1024; typically set so 1 pixel ~ beam radius Organic matter in 0.85 Ga Bitter Springs fm. Chert; Oehler et al., 2006

Science, 2006 Fundamental data of interest is presence/absence of signal and spatial associations. Quantification is a secondary issue Most imaging artifacts are of secondary importance and cannot be seen in scaled images Design purpose: Composition mapping at µm scale

Work of Anne Dekas Interior Edge 3 5 % 15 N Three dimensional ion imaging

Clearly unacceptable for even semi-quantitative ion imaging Must be corrected by tuning the primary beam octapole (‘stigmator’) and various immersion lens electrodes Zr/ 28 Si Distance (µm) Zr/Si ratio of zircon Work of Amy Hofmann Common tuning conditions for ‘spot’ analyses result in horrendous imaging artifacts

Improves by pre-sputtering large area and keeping image ≤ 10 µm No recognized solution, other than ‘gating’ or culling data May be obscured by saturation of images Community should insist on demonstrations that stoichiometric ratios yield roughly ‘flat’ images in domains of interest Zr/ 28 Si Distance (µm) After tuning for ‘flatness’ Before tuning for ‘flatness’ Work of Amy Hofmann Even after careful tuning for ‘flatness’, edge effects are generally still present

40 Ca ion intensity image of Oka carbonatite Cps Image‘Spots’ 42 Ca/ 40 Ca 88 Sr/ 40 Ca 6.44E-36.52E E-42.78E-4 ~ several % artifacts in average element and isotope abundance ratios are common The accuracy of ‘good’ images Work of Alex Gagnon

51015 Sr/Ca (mmol/mol) Sr + 42 Ca + Integrals of 20x20 µm ion images of carbonate standards and samples Oka carbonatite BCC carbonatite standard Coral The accuracy of ‘good’ images Images can provide quantitative data at ~% level accuracy with effort, but the community should insist that this accuracy is tested and demonstrated on a case- by-case basis

Where do spot measurements by nanoSIMS fit into our stable of tools for element/element ratio analysis? Precision (1 s.e.) Spatial resolution (m)Concentration 1nm 1µm 1mm % 1 % 0.1 % 0.01 % 1 % 100 ppm 1 ppm E-probe ATEM LA-ICPMS, conv. SIMS Bulk (e.g., solution ICP) M. Baker, pers. com; Cavosie et al., 2006; Klemme et al., 2008; Sobolev and Hofmann 2007; Hart and Cohen, 1997

Log N i. N j N i + N j (X 0.5 /X = external error for ratio [I]/[j]) X = ~ N i for trace species % 10 % Log (1  error) Follows counting statistics down to ~3 ‰ 1.s.e. error, across a wide range in concentration ‘Spot’ analyses of element/element ratios in carbonates Internal errors Various nominally homogeneous calcite standards; O - beam; 1-2 µm spots Work of Rinat Gabitov 138 Ba/ 42 Ca (~1-10 ppm) 88 Sr/ 42 Ca (1000’s of ppm) 24 Mg/ 42 Ca (100’s of ppm) 1  m

Log N i. N j N i + N j (X 0.5 /X = external error for ratio [I]/[j]) ~ Log (N i ) for trace species % 10 % 88 Sr/ 42 Ca There are limits imposed by drift in ratios during long sputtering Reflects gradual ‘drift’ in intensity and ratios after reaching nominal steady-state sputtering Not sufficiently reproducible to correct completely by matching drift with standards Appears to limit precision to no better than ~0.15 % 1 s.e., relative Internal error (1  Oka Carbonatite; analyzed on the NanoSIMS with a 2 µm rastered spot of O - Work of Rinat Gabitov

Point-to-point reproducibility Tracks counting statistics errors down to ~ %, 1 s.e. Likely only applies to central half of 1” rounds and central 3/4 of 1 cm rounds Illustrated data didn’t require heroic efforts at polishing, but normal caution regarding topography effects is appropriate 10 %1 % 10 % 1 % Point-to-point reproducibility (1  ) Average internal error (1  s.e.) 138 Ba/ 42 Ca 88 Sr/ 42 Ca 24 Mg/ 42 Ca

Slopes of calibration curves vary session-to-session much more than for other SIMS instruments This could reflect fractionations associated with changing the acceptance angle when the immersion lens stack is tuned Session-to-session reproducibility for secondary standards (i.e., assuming given value for a primary standard) follows internal errors down to ~0.8 % 1 s.e..

Many of the carbonate standards available for trace element measurements by SIMS are crap ID-ICPMS data for sub-samples Oka is poor overall, but its calcite matrix has the best long-term reproducibility (±0.8 %) BlueCC is a close second, and lacks ‘nuggets’ of exotic carbonates All of the 7 other commonly used standards we explored are much worse 1 %-level accuracy requires independent analysis of the same crystal AG-1, NBS-19, 135-CC, HUJ-AR & UCI-CC also examined

Precision (1 s.e.) Spatial resolution (m) Concentration 1nm 1µm 1mm % 1 % 0.1 % 0.01 % 1 % 100 ppm 1 ppm E-probe ATEM LA-ICPMS, conv. SIMS nanoSIMS Bulk (e.g., solution ICP) NanoSIMS Where do spot measurements by nanoSIMS fit into our stable of tools for element/element ratio analysis? NanoSIMS

Kunioka, 2006 Semi-quantitative imaging of growth banding in biogenic carbonates Meibom et al., 2004 Foraminifera Surface coral Mg/Ca

Ma et al., 2009 Intergrown CaCO 3 and Ca 0.55 Mg 0.45 CO 3 in a sea urchin’s tooth! 5x5 µm ion image

Calcein marks start of growth during experiment; later layers should carry ‘spikes’ The sub-micron resolution of the NanoSIMS reduces culture time from several months to a few days Ca Gagnon et al Extended example of applied use as a quantitative tool Experimental studies of vital effects

Ion images of overgrowths Calcein stain 43 Ca/ 42 Ca Demonstrations of image ‘flatness’ Gagnon et al., 2012

A conceptual model of coral biomineralization (after McConnaughey) (extracellular calcifying fluid)

Time [Ca] SW [Ca] P 2 hrs Instantaneous Growth Axis 43 Ca 25 Mg Flow in Flow out Precipitation Budget for a metal in ECF External solutionPrecipitated carbonate Natural Spike Well-resolved gradients should measure residence time in ECF ‘mother liquor’ Gagnon et al., 2012

Calcium turnover time (  1/2 ) is less than 2 hrs, possibly much faster Fastest growing measured foram  1/2 = 1.2 hrs Measured growth rates are generally faster than can be resolved by beam width Model of a sharp boundary, given beam ‘broadening’

Growth Axis Ca 2+ Mg 2+ Comparison of profiles should provide evidence for mechanisms of uptake

specific pumping seawater transport Growth Axis Uptake of 25 Mg and 43 Ca spikes Delivery of metals to site of growth appears to be dominated by transport of seawater to growing crystal surface

Gagnon et al., 2012 This conclusion is corroborated by uptake of spikes that are unlikely to be biologically ‘pumped’ across membranes 43 Ca spike 159 Tb spike

Gagnon et al., 2013 Extracting quantitative partition coefficients from ion images of ~µm overgrowths Corals grown over a range of carbonate-ion concentrations

Septa of deep-sea corals; Gagnon et al., 2007Surface corals; Gaetani et al., 2011 ECF Flow in Flow out Precipitation Related work has demonstrated that growth zonation is controlled by variable extents of Rayleigh distillation on carbonate growth from ECF K eq arag-fluid

Gaetani et al., 2011 Fit to Rayleigh distillation model Thermometry using implied K d controlling the distillation fractionation ECF Flow in Flow out Precipitation This advance creates the possibility that models of vital effects will be quantitative tools of paleoclimate reconstructions K eq arag-fluid

Fossil 34-91; a Paleocene mollusk from the Bighorn Basin Work of Katie Snell Using the NanoSIMS to unravel the thorny problem of diagenetic modifications Modified aragonite growth plates Mix of secondary calcite and entombed growth plates

Fossil 34-91; a Paleocene mollusk from the Bighorn Basin 55 Mn 16 O/ 40 Ca 16 O Work of Katie Snell Using the NanoSIMS to unravel the thorny problem of diagenetic modifications

Summary and parting thoughts NanoSIMS may be uniquely suited to quantitative trace element analysis of carbonates with µm to sub-µm zonation (synchrotron µ-XRF may be comparable) Imaging can yield several-per cent errors at scales down to 300 nm; much better is likely unrealistic % (1 s.e.) long-term external precision for ~1 µm domains are demonstrated and half that seems possible Real limitation at present is poor quality of interlaboratory standards Relatively casual standardization could easily result in ~10 % errors There is no established community-wide practice for achieving and documenting precision and accuracy; for the time being, this needs to be approached as an experimental tool, and data in the literature should be approached with a ‘show me!’ attitude.