Medical Gas Supply By Ahmed Ibrahim ; M.D. Prof.of Anaesthesia Ain Shams University.

Slides:



Advertisements
Similar presentations
Compressed Gas Cylinder Safety
Advertisements

Storage and Handling of Medical Gases
David Capal, CEM, CHFM, SASHE David Womack 1.5 Contact Hours /0.15 CEU AHA/ASHE.
GAS BOTTLES Prepare and monitor anaesthesia in animals GAS BOTTLES.
Gas Management Systems
Carbon Dioxide Systems 1.Carbon dioxide properties 2.Storage 3.Uses 4.Limitations 5.Types of systems 6.Local Application 7.Total Flood.
ANESTHETIC MACHINES.
Safety Requirements of the Anesthesia Workstation
INTERMEDIATE PRESSURE SYSTEM PRESENTED BY: Dr CHITTRA MODERATED BY: Dr JYOTI PATHANIA.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 1 of 4.
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Presentations Compressed Gasses.
Supply Of Medical Gases
Program: Respiratory Therapy Course: Introduction to Respiratory Sciences Lesson: Gas Physics Handle Gas Cylinders With Care.
Medical Gas Systems 210a.
Kinetic Molecular Theory of Gases and the Gas Laws
Compressed Gases.
Comparison between American and European Pressure Vessel Rules
Gas Welding (Oxy-acetylene)
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
LAB EQUIPMENT SAFETY CHEMICAL LABELS NFPA / HMIS MSDS
MEDICAL GASES Manufacture, Storage, Transport + Delivery
1 MEDICAL GASES We breathe earth’s atmosphere composed of:  Nitrogen (78%)  Oxygen (21%)  Carbon Dioxide (0.03%)  Argon and trace gases (0.93%) Neon,
Principles of Liquid Flow through Pipelines
Lynn Morrison Regional QA Pharmacist NHS Greater Glasgow and Clyde
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
The gas laws By Dr. Ahmed Mostafa Assist. Prof. of anesthesia & I.C.U.
Medical Gases. Piped and Cylinder Training
Parts of the Anesthetic Machine
Products Training.
Teknologi Dan Rekayasa
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
Inert Gas Fire Extinguishants
CENTRAL GAS SYSTEMS Without reference, identify principles relating to central gas systems as they pertain to facility and equipment interface with at.
Introductory Lecture Series: The Anesthesia Machine
Gases Review. Pressure Conversions kPa = ________atm.
Physical Chemistry I (TKK-2246) 13/14 Semester 2 Instructor: Rama Oktavian Office Hr.: M.13-15, Tu , W , Th.
Gas volume measurement Benedict Roth Spirometer Vitalograph Dry gas meter Wright respirometer (calibration inaccurate if used for continuous flow)
Northvale Korting Fluid Jet Theory and Applications of Eductors By Patrick Belcher.
CXS490 Carbon Dioxide Systems
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
Air Conditioning International Mechanical Code
CSAN Review of Principles. Daltons law and Partial Pressure In a mixture of gases, each gas has a partial pressure which is the pressure which the gas.
FLUID MECHANICS 1. Fluid Mechanics is defined as physical science dealing with the action of fluids at rest or in motion, and applications of devices.
Metal Fabrication Oxygen & Acetylene Integra ® Cylinders 2014.
Parts of the Anesthetic Machine A&A Pages
SAFETY WITH CRYOGENIC SYSTEMS. Safety aspects 1. Physiological 2. Suitability of materials and construction 3. Explosions and flammability 4. Excessive.
Ch. 14 The Behavior of Gases PROPERTIES OF GASES.
Refrigeration Systems
Advanced Resuscitation Certificate Supporting Surfers Paradise SLSC 2004/2005 Surf Lifesaving Club Help Program.
Gas Laws Review.
Mix & Flow of Matter Unit Review. Fluids are used in… 1.0  Technological devices and everyday materials.  Review WMIS Symbols, page 10.
Carbon Dioxide System Design
Bottled Gases Sun Ladder [GFDL ( CC-BY-SA-3.0 ( or CC BY-SA
Sample Problem 8.1 Properties of Gases
Chapter 37: Fluid Containment
Unit III Class I Pneumatics.
MAKING HEALTH CARE SAFE ENGINEERING AND SAFE ANAESTHESIA
Piped gas supply Description
Unit 37: Fluid containment Dr
Gas Cylinders Description
Physics Mr. Jongie G. Gepulgani.
Unit 37: Fluid containment Dr
Compressed Gases.
Sophie Young 21st February 2007
Dip. Software based statistics PhD ( physiology), FICA , IDRA
Anesthesia Monitoring and Equipment
Dip. Software based statistics PhD ( physiology), FICA , IDRA
LAB EQUIPMENT SAFETY CHEMICAL LABELS NFPA / HMIS MSDS
Presentation transcript:

Medical Gas Supply By Ahmed Ibrahim ; M.D. Prof.of Anaesthesia Ain Shams University

The gas laws

● Gas exists in the gaseous state at room temperature and pressure. ● Vapour is the gaseous state of a substance below its critical temperature. At room temperature and atmospheric pressure, the substance is liquid. ● Critical temperature is the temperature above which a gas cannot be liquefied whatever pressure is applied. The critical temperatures for nitrous oxide and oxygen are 36.5 and -118°C respectively

Gases found on anaesthesia machines Oxygen Nitrous oxide Helium used : -to reduce work of breathing in patients with an upper or lower airway obstruction as it has a lower density than oxygen, nitrogen and air. -in laser surgery around the airway to reduce the flammability of the breathing mixture. -in the measurement of lung volumes because of its very low solubility. Air used to dilute oxygen when other gases are not desired.

Medical Gas Supply cylinders a piped gas system

Cylinders ● made of thin-walled molybdenum steel to withstand high pressures. Lightweight O 2 cylinders can be made from aluminum alloy used during transport. ● are made in different sizes (A to J).; size E is used on anaesthetic machine; size J is used in cylinder banks. ● O 2 cylinders contain gas, while N 2 O cylinders contain a mixture of liquid and vapour. filling ratio = weight of fluid in cylinder / weight of water required to fill the cylinder filling ratio of N 2 O is In hotter climates, it is reduced to 0.67 ● are colour-coded.

Body colour (UK) Shoulder colour (UK) Pressure, kPa (at room temperature) Physical state in cylinder Oxygen Black (Green in USA) White13 700Gas Nitrous oxide Blue 4 400liquid / vapour Carbon dioxide Grey 5 000liquid / vapour Air Grey (Yellow in USA) White/black quarters Gas Entonox BlueWhite/blue quarters Gas Oxygen/helium (Heliox) BlackWhite/brown quarters Gas

OxygenWhite Nitrous oxideLight blue Medical airBlack and white SuctionYellow NitrogenBlack Carbon dioxideGrey HeliumBrown Standard colour

SizeCapacity (liters) OxygenNitrous oxide E J

absolute pressure = gauge pressure + atmospheric pressure “At a constant temperature, the pressure in a GAS cylinder decreases linearly and proportionally as it empties. “ This is not true in cylinder containing liquid / vapour.

Cylinders are tested regular intervals, usually 5 years: 1. Internal endoscopic examination 2. Flattening, bend and impact tests ; are carried out on at least 1/100 cylinders. 3. Pressure test ; the cylinder is subjected to high pressures of about kPa, which is more than 50% above their normal working pressure. 4. Tensile test ; where strips of the cylinder are cut and stretched. This test is carried out on at least 1/100 cylinders.

Marks engraved on the cylinders are: 1. Test pressure. 2. Dates of test performed. 3. Chemical formula of the cylinder’s content. 4. Tare weight (weight of nitrous oxide cylinder when empty). Labeling. The cylinder label includes the following details: ● name, chemical symbol, pharmaceutical form, specification of the product, its license number and the proportion of the constituent gases in a gas mixture ● substance identification number and batch number ● hazard warnings and safety instructions ● cylinder size code ● nominal cylinder contents (litres) ● maximum cylinder pressure (bars) ● filling date and expiry date ● directions for use ● storage and handling precautions.

Cylinder valves ● They are mounted on the neck of the cylinder. ● Act as an on/off device for the discharge of cylinder contents. ● Pin index system to make it almost impossible to connect a cylinder to the wrong yoke ( O 2 2&5, N 2 O 3&5, CO 2 1&6, Air 1&5 ) O 2 2,5 N 2 O 3,5 CO 2 1,6 Index positions of a cylinder valve

● Bodock sealing washer must be placed between the valve and the yoke of the anaesthetic machine.

Pressure Regulator As gas flows out of the low-pressure chamber, the drop in pressure reduces the force generated by the diaphragm (D) against the spring (S), allowing the valve (V) to open and admit gas from the high-pressure chamber. The output pressure may be adjusted by a screw (A) that alters the force applied by the spring.

Piped Gas Supply ● a network of copper alloy pipelines from central supply points. ● The outlets are colour- and shape-coded to accept matching ‘Schrader’ probes. wall-mounted outlet socket ceiling unit

● Flexible and colour-coded pipelines run from the anaesthetic machine to the outlets. ● There is risk of fire from worn and damaged hoses.

Source of Gas supply ● Cylinder manifold : banks of large cylinders( usually size J), usually divided into two groups, primary and secondary (alternating supplying the pipelines automatically) ● Liquid oxygen : a thermally insulated vessel at a temperature of -150°C to -170°C and a pressure of 5 –10 atmospheres is used. ● Oxygen concentrator : extracts oxygen from air by differential absorption, a zeolite molecular sieve is used.

Cylinder Manifold

Liquid Oxygen

atmospheric air is entrained by the concentrator, filtered and raised to a pressure of 20 psi by a compressor