Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION May 2014 TechConnect Genius Webinar AC Variable Frequency.

Slides:



Advertisements
Similar presentations
Wiring of the Electric Motor By Irri-Gator Products (Pty) Ltd.
Advertisements

Chapter 12 Transformers. Chapter 12 Transformers.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
ENERGY CONVERSION ONE (Course 25741)
Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.
Chapter 13 Transmission Lines
VARIABLE SPEED DRIVES HARMONIC EFFECTS & EFFECT OF USE WITH LONG CABLES (100 – 300m) Electric Motors & Drives ….OUR VISION, YOUR SOLUTION ……. TOGETHER.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
[ 1 ] LVDS links Servizio Elettronico Laboratori Frascati INFN - Laboratori Nazionali di Frascati G. Felici LVDS links.
©2004 Fluke Corporation Introduction to Motor Troubleshooting 1 Introduction to Motor Troubleshooting.
Transformerless UPS Neutral handling and grounding considerations
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
The X-Ray Circuit.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
Designing a EMC Compatible Electronic Meter using AD7755 a.
7154 VFD Presentation #3 May 2002 Paul Weingartner.
Dry type transformers Zaragoza Traction application
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
7154/7156 Variable Speed Drives
© 2011 Ericson Manufacturing, Willoughby, Ohio
Chapter 8 Output Modules.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Dealer Certification Section 2: Building the Network Physical Planning & Documentation Power Sources & Distribution Voltage Drop Calculations Copyright.
2004 SMMA1 EMI and EMC Aspects of a Brushless Repulsion Motor/Drive Presented by DynaMotors, Inc.
Three Phase Power Three Phase Motors
Unit 29 Three-Phase Transformers. Objectives: Discuss the construction of three-phase transformers. Discuss the formation of a three-phase transformer.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
150W Inverter - an optimal Presenter: Dr Gawie van der Merwe design in solar home systems.
Power Electronics and Drives (Version ) Dr. Zainal Salam, UTM-JB 1 Chapter 3 DC to DC CONVERTER (CHOPPER) General Buck converter Boost converter.
© 2008 Snap-on Incorporated; All Rights Reserved.
Protection Against Transient Overvoltages
PROFIBUS wiring/installation can be done with:
Transient Overvoltages
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Section 3.1: Wires, Cables, and Connectors Scott Glogovsky and Jonathon Sturm Scott Glogovsky and Jonathon Sturm.
A PRACTICAL TRAINING SEMINAR ON PLCC
Transmission Lines No. 1  Seattle Pacific University Transmission Lines Kevin Bolding Electrical Engineering Seattle Pacific University.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
IPC Power Distribution Considerations A predominately important factor that should be considered in the design of a printed board is power distribution.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
ELECTRICAL SAFETY FOR INSTRUMENTS SECTION. Electrical measurement safety Understanding hidden hazards and new safety standards.
Department of Electrical Engineering
Grounding.
Submitted To:- Submitted By:- Mr.
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
Variable Frequency Drive (VFD) Cable VFD Cable Solutions.
SMJE 2103 Overvoltage, Electrical Insulation and Protection Devices.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved.
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
SARDAR VALLABHBHAI PATEL INSTITUTE OF TECHNOLOGY PREPARED BY: 1)BALDIWALA ALIABBAS ( ) 2)PARTH GUPTA ( ) 3)ANIL KHATIK ( )
EMC issues for cabling and racks layout design. (Belle II – Grounding) F.Arteche.
Electrical Power System
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
Grounding.
High Voltage Coil with Extra Insulation on initial turns
THREE-PHASE GROUND-FAULT BASICS
Lesson 11: Transformer Name Plate Data and Connections
Calculations: Transformers and Service Conductor Calculations
EET 323 – Electrical System Design Lecture 9: Grounding
Presentation transcript:

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION May 2014 TechConnect Genius Webinar AC Variable Frequency Drives Best Practices Thomas Svoren Title – Sr. Technical Support Engineer Date –

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 2 Agenda Panel Installation Practices Installation Considerations Identifying Your Power System

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System  Reasons for use:  Delta / Wye with Grounded Wye Neutral is the most common type of distribution system  Controlled path for common mode currents  Consistent line to ground voltage reference which minimizes insulation stress  Better accommodation for system surge protection schemes  Rockwell strongly recommends the use of grounded neutral Wye systems for Variable Frequency Drives and DC Drives 3 Delta / Wye with grounded Wye neutral (Recommended)

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System  Reasons for use:  Offer a measure of protection against high current ground faults. You can still run while a ground fault condition is present.  Warnings:  Allows transient over-voltages to form during ground faults. Ground faults on the secondary can cause primary voltage to ground on the secondary side. I.E. 13.8Kv to 480V transformer can have 13.8kv to ground on the secondary in the event of a ground fault.  No Common Mode Current path, high probability of issues with other instrumentation  A higher line-to-ground voltage (1.732 x) than in a neutral-grounded system,  MOV’s and Common Mode Capacitors in electronic equipment referenced to ground must be disconnected. Removing the MOV’s to ground the system loses UL and CE certifications. 4 Ungrounded Delta/Wye and Delta/Delta (Not Recommended)

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System  Reasons for Use:  A configuration providing voltage re-balancing with no phase shift between input and output.  Ability to supply dual-voltage service for lighting and power loads. Allows for a tapping of a leg for these voltages  Warnings:  Requires the identification of the grounded phase throughout the system to avoid connecting current measurement devices I.E. Meters, fuses, instruments, and relays in the grounded phase  A higher line-to-ground voltage on two phases (1.732 x) than in a neutral-grounded system 5 Delta / Delta with Grounded Leg or Four-Wire Connected Secondary Delta (Not Recommended)

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System  Look at the supply transformer nameplate  Check for a power one line of the facility  Measure voltage phase to ground  Ungrounded systems will most likely not have consistent voltage readings to ground for each phase  If in doubt supply a separately derived source by adding a Delta/Wye grounded neutral secondary transformer for the drive system 6 How do you know which power system you have?

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System  For harmonic considerations the total drive (non-linear) loading should not exceed 60% of the transformer KVA rating  If your transformer size exceeds the following guidelines, add a line reactor  Transformer KVA rating should not exceed 20:1 ratio above the individual drive KVA rating for drives with DC link choke or percent source impedance relative to the drive impedance is < 0.5%  Transformer KVA rating should not exceed 10:1 ratio above the individual drive KVA rating for drives without DC link choke or percent source impedance relative to the drive impedance is < 0.25%  Refer to Publication DRIVES-IN001 under AC Line Impedance section 7 Transformer sizing guidelines

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Identifying Your Power System 8

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 9 Agenda Panel Installation Practices Installation Considerations Identifying Your Power System

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 10 What a VFD does and what the input/output voltage and current looks like

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed.  11 Creation of common mode current V ng I lg 4 kHz Switching Pattern (PWM) of Output IGBT Common Mode Voltage pattern

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed.  12 Common Mode Current Path and Effect on Electronic Equipment AC Drive Common Mode Current Path PE EARTH GROUND Potential #3Potential #1 Motor Potential #2 X O R U V W S T PE I lg Motor Frame I lg I I I I C lg-c C lg-m A B C Vdc bus (-) (+) Logic True Earth Ground (TE) Interface Electronics 0-10V, communication, 4-20 ma,sensor interface, etc. Potential # 4 Tach Input Transformer Vng Common Mode Noise Current Path causing ground EMI Interference

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Installation Considerations 13 Power Jumpers for the PowerFlex® 7xx Class drives Power jumper circuit locations

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Cable Types  Input Cables  No Special Considerations  Output Cables  Length  Cable Charging Current  Reflected Wave  Voltage Drop  Type  Individual conductor  Bundled cable  Shielded  Unshielded 14

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Cable Charging Current 15 U V W PE C ll C lg C lg-c I MOTOR C lg-m L 01 R L 02 R L 03 R Drive Motor Conduit C ll-m I ll I lg

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Output Cable Length Considerations  Cable Charging Current  At every switch of the IGBT the capacitance of the cable must be charged  For smaller motors (<2HP) the cable charging current can exceed the motor/drive current rating  I.E. with a 5ma per foot charging current on a 300 ft. run the charging current will be 1.5 amps which is the equivalent current of a 1 HP motor at 460VAC.  Mitigation Techniques  Use a larger drive to supply the cable charging current  Common Mode Choke around the motor leads  Output Line Reactor  Move the drive closer to the motor 16

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Reflected Wave 17

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Output Cable Length Considerations  Reflected Wave  Voltage magnitude of drive pulse  Motor and cable surge impedance mismatch  Rapid rise time of drive pulse due to type of semiconductor switch in the drive  Long cable length 18

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed. Reflective Wave Close Up

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed. Typical Failure, Very Subtle and Hidden in windings

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Output Cable Types  Reflected Wave, what can we do about it?  Keep motor lead lengths as short as possible  Specify and buy inverter duty insulated motors (with NEMA motor standard MG1 part )  Install a motor “protection” device where needed  Reflected wave reduction method at the drive 21

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION How Long is Too Long? 22 From Appendix A of Wiring and Grounding Guidelines Publication DRIVES-IN001

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Rockwell and NEMA Voltage Classifications 23  Classify Categories of motor insulation at 0.1 us rise time:  1,000 Vpk Category: Motors without phase & slot insulation  1,200 Vpk Category: Motors with additional phase insulation  1,488 Vpk Category: Preferred Choice for 480 V IGBT Drives  NEMA MG1 Part , 1998 “Insulation can withstand voltage spikes of up to 3.1 times motor rated voltage” which specifies for 480 volt application 1488 VPK.  1,600 Vpk Category: Motors manufactured for Rockwell for 480 volt applications  1,850 Vpk Category: Motors manufactured for Rockwell for 600 volt applications  2000 Vpk category: Motors manufactured for 690 volt applications

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Voltage Drop  Resistive voltage drop  Voltage Drop = Rated Current * Cable Resistance * Motor Power Factor  Reactive voltage drop is another consideration  2* π * Fundamental Frequency*Cable Inductance 24 Cable voltage drop is another consideration in cable length as the voltage drops the current increases at the motor

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Cable Types  Individual Conductors  XLPE type insulation is recommended  THHN is not recommended  THHN is susceptible to moisture  Outer nylon cover can crack and reduce corona inception voltage rating 25

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Common Mode Currents in Conduit

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Cable Type  Bundled (No Shield)  Benefits  Ease of installation compared to individual conductors  Lower cable charging current with XLPE insulation compared to shielded cable  Disadvantages  Radiated emissions higher than shielded cable  Geometry of the cable can effect the radiated emissions 27

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Cable Type  Bundled (Shielded)  Benefits  Ease of installation compared to individual conductors  Lower radiated emissions  Common mode current directed back to the source  Disadvantages  Higher cable charging current 28

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed. Additional Containment of Common Mode Current Paths - Better Shielded output cable/armor with PVC jacket PROVIDES BETTER WIRING & NOISE CONTROL WITH NO ACCIDENTAL ARMOR CONTACT TO GROUND BUT IF NOT USED ON INPUT MAY ALLOW Ilg NOISE PATH BACK TO GROUND

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 30 Agenda Panel Installation Practices Installation Considerations Identifying Your Power System

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Copyri ght © 2008 Rockw ell Autom ation, Inc. All rights reserv ed.  31 Containing Common Mode Current Paths to Prevent Problems Start with Good Panel Layout

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 32 Panel Layout is Important Better Panel Layout

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Other things to consider  Follow proper wire spacing guidelines  If control and power wires must cross, do this at a 90 degree angle  Surge suppress any large inductive loads (i.e., mechanical brakes, contactors, etc.)  Do not use a painted surface for a grounding point (galvanized backplane suggested).  When routing signal wires, route the feed and return together or use twisted pair wire.  Avoid nicking wire insulation when going through flexible conduit 33

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Follow ROKAutomation on Facebook & Twitter. Connect with us on LinkedIn. Rev 5058-CO900F PUBLIC INFORMATION Questions