Adaptations and Modifications of methods used by GSFMC processors for sectioning Gray triggerfish spines Elisabeth H Laban Biological Science Technician.

Slides:



Advertisements
Similar presentations
Build Your Own Future RC2 Serviceability. Build Your Own Future Safety and Ground Rules Before servicing, always remove A/C power from the unit and disconnect.
Advertisements

Step-by-step assembly instructions
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions Edvotek Set Up 12 groups.
HVAC523 Soldering.
Power Tools Safety. Portable Circular Saws Stock must be well supported in such a way that the kerf will not close and bind the blade.. Thin materials.
Tissue Embedding and Sectioning
Optical Manufacturing Solutions 1 Probe Assembly.
Click on this image to open the full PDF document.
Cutting With a Jeweler’s Saw
Working With Acrylic 1. Acrylic Uses 2. Cutting Acrylic
Lifter Step-by-step assembly instructions (c) 2010 National Fluid Power Association.
Step-by-step assembly instructions
MyLock 644D Service Seminar.
Milling Machine Setups
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions VWR Set Up 12 groups Mira Costa kit.
The Glue Method. 1. Take a clean slide and carefully place a coverslip at one end of it.
Method to fix wall tiles. Preparation All wall tiles to be immersed in water for 3-4 hours for better results. Some gap in between the rows to allow the.
 Identify the parts of a compound light microscope and explain their functions  Define magnification  Calculate the total magnification of the lenses.
Overview of Otolith Thin Slice Method
Hydraulic Digger Step-by-step assembly instructions (c) 2013 Mechanical Kits Ltd.1.
Pneumatic Arm Assembly Instructions
Recone Steps for 9900 Series. Tear Down 1 Cut through surround and spiders, remove cone assembly.
Ocean Science Data Based Lesson A Guide to Construction of Materials for Ships, Ocean and Satellites (S.O.S.) Paper version This guide is intended to be.
Reduction Printmaking with Foam Plates
SEACORK INSTALLATION ON A CATAMARAN The first step is to make templates of all corner pieces to be cut from sheet material, which will be used for border.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions BioRad Set Up 8 groups Grossmont Kit.
Service Seminar Memory Craft Table of Contents MC10001 Top Cover Removal…………………………………………………………………..…………1 Belt Cover Removal……………………………………………………………..……………2-4.
Introduction to Precision Metrology
TOOL: Radial Arm Saw NEXT STEP: Radial Arm Saw RESULTS: Finish Top Apron Pieces at 9” L x 4” W x ¾ “ Th PROJECT Square Plant Stand PART Top Apron # NEEDED.
Preparing & Exposing Photographic Silkscreens For use with Lesson 3 FOR EDUCATION USE ONLY ©2009 The Andy Warhol Museum, a museum of Carnegie Institute.
Mantle Clock. Beginning Steps Cut 2 piece 20 x 5 to make the 2 sides and top/bottom Cut 1 10 ¾ and 1- 9 from each 20 piece. This will make a side and.
Lone Star Region National Model Railroad Association “The Shack” Scratch Build -Mike Jobe SESSION 2.
DO NOW: 1.Hand in the field trip brainstorming you wrote on Friday. 2.Take out your microscope Green packets from last week. 3.In your NOTES section of.
DO NOW: Take out your microscope YELLOW packets from last week.
Step 1: Prepare the surface The floor should be clean, dry, flat and sound. The floor should be free from oily/waxy or curing compounds.
1 HVACR316 - Piping Soldering. 2 Soldering Copper Tubing The most common method of joining copper tubing in hydronic heating systems is soft soldering.
Microscope Lab. Mrs. Orwar’s sure fire way to find an image every time! 1.Start on low power (red objective) 2.Place your slide centered over the light.
Safety Rules for 9 th Grade Shop Radial Arm Saw: Safety Rules Never cut a board that is less than 12 inches long. Always pull the saw using the handle;
The Compound Microscope
Lifter Step-by-step assembly instructions (c) 2010 National Fluid Power Association.
Preparation Of Carrot Explants 1.) Wash carrot taproots in warm, soapy water. Break or cut carrot taproots into pieces 7 cm or less in length. Be careful.
Microscopes Biology Light Microscope (LM) [aka Compound Microscope] Visible light is projected through the specimen. Glass lenses enlarge the image &
Directional Terms Used in Association with the Body Anatomical Terminology.
Build a Simple Electric Motor Uses a stator made of windings, an armature with two coils, and a commutator.
How to Change Raptor Knife Blades. Step 1: Use a Phillips screwdriver to remove the 5 screws. It is not necessary to remove the lanyard/webbing to change.
Care and Use of the Compound Microscopes Moorpark College Biology Department.
Egg Carrying Rocket Complete Your goal is to have your rocket looking something like this at the end of this section– fins attached and rocket engine block.
ELECTRIC VEHICLE PROJECT CAR BUILDING PROCEDURES BY: PIERRE PEASHA CENTENNIAL HIGH SCHOOL BAKERSFIELD, CA.
Making Metric Measurements. Ruler Metric rulers are fairly easy to read. They deal with centimeters and millimeters only. You won’t have to worry about.
Preparation of Plant tissues for histological study.
Microtome is a sectioning instrument that allows for the cutting of extremely thin slices of material, known as sections. Microtome are an important device.
Introduction to Precision Metrology
BORDER SEAL After finish the festooning of all polished surfaces and carving of the cast in the post dam area. Now the next step is to do border seal.
Flasking and wax elimination
BLOOD SPATTER ANALYSIS or Blood Pattern Analysis = BPA
Step-by-step assembly instructions
Facing & Center Drilling
Step-by-step assembly instructions
Gel Electrophoresis Teacher Instructions BioRad Set Up 12 groups
Step-by-step assembly instructions
Step-by-step assembly instructions
Step-by-step assembly instructions
Step-by-step assembly instructions
Step-by-step assembly instructions
Step-by-Step Assembly Instructions – Cube Version
Step-by-step assembly instructions
Making Fiber Cross Sections
Step-by-step assembly instructions
Building a Tissue Paper Hot Air Balloon
Presentation transcript:

Adaptations and Modifications of methods used by GSFMC processors for sectioning Gray triggerfish spines Elisabeth H Laban Biological Science Technician NOAA/NOS/CCEHBR and SC DNR MRRI

It is important to track your sample through the process of mounting and cutting sections. Flagging each spine with a numbered label is one way to accomplish this.

spine morphology Posterior view of triggerfish spine Anterior view of triggerfish spine Dorsal tip of spine Ventral base of spine Lateral or medial left medial right medial left Lateral or medial right Posterior/lateral view of base of dorsal spine. LC, lateral condyle; CG, condyle groove; PCP, posterior condyle process; and TCG, tip of condyle groove. LCPCP Posteromedian groove CG Part of head that was removed with spine TCG

Some samples may be returned to the lab with part of the skull cap still attached to the dorsal spines. Excess material can be removed using nippers Part of skull medial right Lateral or medial left medial left Lateral or medial right

Dried tissue, muscle and fibers are scraped clean from the area of interest, from the base of the spine to at least a centimeter above the tip of the condyle groove, using an X-acto knife, forceps, razor blade, and/or a nylon bristle brush. The posterior condyle process is “shaved” to allow the spine to lie “flat” mounting the spine laterally for cutting. CG PCP Posteromedian groove CG TCG

Using a black marker, a cut line is marked on the cleaned spine at the dorsal tip of the condyle groove. This is done to assist in aligning the spine when mounting and cutting, as the best sections for age determination are cut dorsal to the tip of the condyle groove. PCP a=anterior; p=posterior; d=dorsal; v=ventral; l=lateral CG Tip of CG Posterior views of cleaned spine Lateral views of cleaned spine a a p p d d v v l l

After cleaning and marking the cutting line on the spine, it is flagged with a label containing enough of the sample identification number to uniquely distinguish it from the other samples to be processed.

For convenience, the flagged spines are placed on cafeteria tray, or other storage container, until “enough” spines have been cleaned and flagged and you are ready to mount samples for cutting. This way the spine does not need to be returned to the sample storage envelope before mounting and cutting.

Currently, GSFMC processors are gluing the spine to an index card and securing the index card (ic), and a piece of cardboard (cb), used as a cushion, to the metal cutting plate (mcp) with binder clips. Note that the GSFMC blade assembly consists of four blades and three spacers, resulting in three sections of a cut spine b Above images by Carrie Fioramonti; University of West Florida To reduce the waste created by single use index cards and limited use cardboard “cushions”; which become water logged during cutting; the GSFMC mounting materials were replaced with a heavy gauge frosted plastic notebook cover (or heavy gauge 3-ring notebook dividers) and craft foam sheets. The frosted plastic and the craft foam are waterproof and thus can be reused many times. ic cb mcp

Both the craft foam sheet (“a” on the images) and the heavy gauge frosted plastic notebook cover (“b” on the images) have been cut to the size of the metal cutting plate. Alignment lines are marked on the craft foam piece (see arrows). When the plastic cutting plate is placed on the craft foam, the alignment lines are clearly visible. The cutting line on the spine is also visible through the plastic. a b b b a b ba a b

The plastic cutting plate is placed on the craft foam. The spine is oriented with the alignment lines on the craft foam, and an additional mark is placed on the spine near the “cushion rest” (reducing the amount of glue used). High temperature hot melt glue is then applied to either the spine or the plastic and the spine secured in place along the alignment lines.

These images show a flagged spine mounted, medial right, to the frosted plastic cutting plate. The cutting mark on the spine is visible through the glue and plastic. The yellow craft foam “cushion” shows how it has been used to aid in the horizontal alignment of the spine and to reduced amount of glue used.

This series of images shows a flagged, marked spine, mounted with the anterior surface against the plastic cutting plate. The alignment lines on the craft foam and the craft foam “cushion” help in assuring a perpendicular cut.

Once the spines have been mounted on the plastic cutting plates, they can be stored for later processing. As you can see in the picture below, some samples are stored in a box and others have been stored flat and overlapping on a cafeteria lunch tray

The swing arm is then moved so the outside of the parallel alignment mark is just touching the edge of the first, or “inside”, blade. With this alignment and care during mounting, little to no adjustment to the swing arm is necessary when mounting the cutting plates for processing. The craft foam cushion can be temporarily held in place, against the metal cutting plate with a few drops of water. The swing arm is lowered and allowed to rest on the blade assembly to adjust the cutting chuck so the perpendicular alignment mark is resting directing against the blades.

A plastic cutting plate with a mounted spine is placed against the craft foam cushion, making sure the alignment is correct, and the entire assembly is clamped in place to the metal cutting plate with 3 binder clamps. cf mcp pcp

The sample is lowered near the blade to adjust the swing arm if necessary. The swing arm is lifted and the saw is turned on and the dial set between 7 and 8 (210 and 240 rpm), the sample is lowered onto the moving blades and the sample is cut. ba 1 st cb mcp cf pcp cm

If you are not sure you have completely cut through the spine; you can lift the swing arm, turn the speed dial to zero, remove the front clamps, bend the plastic cutting plate down and away to check if the cut is visible on the backside of the cutting plate. You can also bend the plate back on itself to see if the spine and sections “separate”. Care should be taken to avoid breaking the spine before the cutting is complete. If there is no indication that the cut is complete, re-clamp the assembly and continue cutting. The cut is not complete there is material still visible against plastic cutting plate. The cut is complete, cut spaces are visible against plastic cutting plate. Bending the cutting plate to see if the cut is complete.

When cutting is complete, remove the plastic cutting plate from the saw. Using forceps, remove the sections from the cutting plate, bending the cutting plate backwards can help expose the sections for easy removal. Place the spine sections on a microscope slide labeled with the sample’s complete unique identification number.

This is an image of dorsal spine sections from Gray triggerfish, mounted with CytoSeal, on glass slides, labeled with the unique identification number. The slides are stored on the trays of an Eberbach slide cabinet until the CytoSeal has dried. The slides are then transferred to a slide box for about two weeks to allow the CytoSeal to completely cure. Finally, the slides are transferred to slide drawers for storage until the samples are analyzed.

Using a single edge razor blade, and care, the glue is “scraped” off the plastic cutting plate, allowing the plate to be used again and again. Even if you nick or “cut” a small hole in the plastic plate during glue removal, the plate is still reusable. Simply reorient the plate for the next spine mounting session. I have found it easier to remove the glue, without nicking the plastic, by doing this step during the cutting process (i.e. While one sample is being cut; the sections from the previous sample are adhered to the labeled slide, remnants are removed and returned to the sample envelope and the glue is removed from the plastic cutting piece. ) The small amount of water remaining from the cutting process acts as a bit of lubricant during the glue removal. This step can be completed when all the samples have been cut, just use a bit more care.